<?xml version="1.0" encoding="utf-8" standalone="yes"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
	<channel>
		<title>Início on PENGCHI</title>
		<link>https://pengchi.net/pt/</link>
		<description>Recent content in Início on PENGCHI</description>
		<generator>Hugo</generator>
		<language>pt-BR</language>
		
		
		
		
			<lastBuildDate>Wed, 14 Oct 2026 09:21:17 +0000</lastBuildDate>
		
			<atom:link href="https://pengchi.net/pt/index.xml" rel="self" type="application/rss+xml" />
			<item>
				<title>Bacia de lavagem médica (tipo com sensor automático) (Desenho Industrial CN 305639785 S)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201930451592-a_medical_wash_basin_automatic_sensor_type-design/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201930451592-a_medical_wash_basin_automatic_sensor_type-design/</guid>
				<description>&lt;h2 id=&#34;informações-do-produto&#34;&gt;Informações do Produto&lt;/h2&gt;&#xA;&lt;table&gt;&#xA;&#x9;&lt;thead&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Item&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Detalhe&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/thead&gt;&#xA;&#x9;&lt;tbody&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Autoridade emissora&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Administração Nacional de Propriedade Intelectual da República Popular da China (CNIPA)&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Tipo de documento&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Patente de Desenho Industrial&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Número de publicação da concessão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;CN 305639785 S&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Data de publicação da concessão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2020.03.13&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Número do pedido&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;201930451592.2&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Data de depósito&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2019.08.20&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Titular da patente&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Dongguan Pengchi Tecnologia de Purificação Ltda.&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Endereço&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Estrada Tangyilangwei, Vila Tangjiao, Município de Chashan, Cidade de Dongguan, Província de Guangdong 523378, China&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Projetistas&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Li Dexiong; Hu Guopeng; Wang Haiou&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Agência de patentes&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Agência de Propriedade Intelectual Dongguan Yongqiao (Sociedade em Nome Coletivo), Código 44400&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Agente de patentes&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Jiang Yabing&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classificação de Locarno&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;06-04; 23-01&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Nome do produto&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Bacia de Lavagem Médica (Tipo com Sensor Automático)&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;h2 id=&#34;declaração-resumida&#34;&gt;Declaração Resumida&lt;/h2&gt;&#xA;&lt;ol&gt;&#xA;&lt;li&gt;Nome do produto: Bacia de Lavagem Médica (Tipo com Sensor Automático).&lt;/li&gt;&#xA;&lt;li&gt;Uso: O produto deste desenho é utilizado para a lavagem das mãos por médicos em salas de operação de hospitais.&lt;/li&gt;&#xA;&lt;li&gt;Ponto característico do desenho: O ponto característico do produto reside na sua forma global.&lt;/li&gt;&#xA;&lt;li&gt;A imagem que melhor ilustra os pontos característicos do desenho é a vista em perspectiva.&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;h2 id=&#34;vistas&#34;&gt;Vistas&lt;/h2&gt;&#xA;&lt;p&gt;&lt;img src=&#34;https://pengchi.net/media/pdf/patents/figures/CN201930451592/fig1.png&#34; alt=&#34;Vista frontal&#34;&gt;&#xA;&lt;em&gt;Vista frontal&lt;/em&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Cabine de pesagem com fluxo descendente de pressão negativa (Modelo de Utilidade CN 210051420 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920997734-a_negative-pressure_downflow_weighing_booth-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920997734-a_negative-pressure_downflow_weighing_booth-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma cabine de pesagem de fluxo descendente com pressão negativa, compreendendo um corpo de cabine, cujo interior é dividido em uma câmara de trabalho, uma primeira câmara de filtragem, uma câmara de trabalho do ventilador e uma segunda câmara de filtragem; a primeira câmara de filtragem possui uma entrada de ar, um ventilador está em comunicação com a primeira câmara de filtragem por meio de um duto de ar de entrada e em comunicação com a segunda câmara de filtragem por meio de um duto de ar de saída, a segunda câmara de filtragem possui uma saída de ar A e uma saída de ar B, a saída de ar A está em comunicação com a câmara de trabalho, e a saída de ar B está em comunicação com o espaço externo do corpo da cabine; a câmara de trabalho possui uma cortina isolante de poeira; o corpo da cabine é montado a partir de uma pluralidade de chapas horizontais e uma pluralidade de chapas verticais, e cada chapa horizontal e cada chapa vertical é composta por uma chapa externa e uma chapa interna, compreendendo uma camada intermediária oca, uma camada de algodão isolante acústico e uma camada de placa de fibra de vidro entre a chapa externa e a chapa interna; uma mesa deslizante de parafuso de servomotor é instalada fixamente em uma chapa divisória, um deslizador está disposto na mesa deslizante de parafuso de servomotor, e uma superfície de trabalho é fixada no deslizador. Por um lado, a estrutura dos corpos das chapas da cabine de pesagem é ajustada para melhorar a função de isolamento acústico da cabine de pesagem e, por outro lado, a altura da superfície de trabalho pode ser ajustada de acordo com a altura do pessoal operacional.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Caixa de Passagem de Três Portas com Intertravamento Eletrônico (Modelo de Utilidade CN 210750384 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920992532-a_three-door_electronic-interlocking_pass-through_box-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920992532-a_three-door_electronic-interlocking_pass-through_box-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma caixa de passagem de intertravamento eletrônico de três portas, compreendendo um corpo de caixa. O corpo de caixa possui uma primeira abertura, uma segunda abertura e uma terceira abertura, e um primeiro painel de porta, um segundo painel de porta e um terceiro painel de porta são dispostos na primeira abertura, na segunda abertura e na terceira abertura, respectivamente. Um primeiro dispositivo de intertravamento eletrônico, um segundo dispositivo de intertravamento eletrônico e um terceiro dispositivo de intertravamento eletrônico são dispostos no corpo de caixa; uma lâmpada germicida ultravioleta é disposta em uma extremidade superior no interior do corpo de caixa; uma cavidade é disposta na parte inferior do corpo de caixa, e um gerador de ozônio é disposto na cavidade; orifícios de ar que comunicam com a cavidade são dispostos nas partes inferiores dos lados internos da primeira abertura, da segunda abertura e da terceira abertura. A caixa de passagem de intertravamento eletrônico de três portas do presente modelo de utilidade possui três painéis de porta, permite a transferência entre uma área não limpa, uma área limpa e outra área limpa, e minimiza a contaminação das áreas limpas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Caixa de passagem filtrante com intertravamento de três portas (Modelo de Utilidade CN 210750363 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920992510-a_three-door_interlocking_filter_pass-through_box-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920992510-a_three-door_interlocking_filter_pass-through_box-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma caixa de passagem com filtro e intertravamento de três portas, compreendendo um corpo de caixa. O corpo de caixa compreende uma câmara superior e uma câmara inferior; um exaustor é fornecido no topo do lado interno da câmara superior, e um filtro primário é fornecido no lado inferior de uma entrada de ar do exaustor. A câmara inferior possui uma primeira janela, uma segunda janela e uma terceira janela, e um primeiro painel de porta, um segundo painel de porta e um terceiro painel de porta são fornecidos na primeira janela, na segunda janela e na terceira janela, respectivamente. Um primeiro dispositivo de intertravamento eletrônico, um segundo dispositivo de intertravamento eletrônico e um terceiro dispositivo de intertravamento eletrônico são fornecidos no corpo da caixa. Uma placa protetora é fornecida em uma face oposta ao segundo painel de porta; a placa protetora possui uma pluralidade de orifícios de ventilação, e uma lâmpada ultravioleta é ainda fixada no lado interno da placa protetora. A caixa de passagem com filtro e intertravamento de três portas do presente modelo de utilidade possui três painéis de porta, permite a transferência entre uma área não limpa, uma área limpa e outra área limpa, e minimiza a contaminação das áreas limpas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Catálogo</title>
				<link>https://pengchi.net/pt/docs/downloads/catalog/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/catalog/</guid>
				<description>&lt;h2&gt;&lt;strong&gt;Download do Catálogo Pengchi&lt;/strong&gt;&lt;/h2&gt;&#xA;Mobiliário Médico&#xA;Mobiliário de Laboratório&#xA;Sala de Operações&#xA;Porta Médica</description>
			</item>
			<item>
				<title>Dispositivo de Ventilação de Túnel (Modelo de Utilidade CN 208380620 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201821017788-a_tunnel_ventilation_device-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201821017788-a_tunnel_ventilation_device-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade se refere ao campo técnico de tratamento de ventilação de túneis, em particular a um dispositivo de ventilação de túnel, compreendendo um duto de ventilação principal disposto no topo de uma cavidade interna de um túnel, sendo o duto de ventilação principal disposto ao longo da direção do comprimento do túnel. Uma extremidade do duto de ventilação principal se estende para fora do túnel para formar uma entrada de ar, e um ventilador exaustor é disposto na entrada de ar. Um dispositivo de filtragem de ar em comunicação com a entrada de ar é disposto no duto de ventilação principal em uma posição adjacente à entrada de ar, e uma pluralidade de saídas de ar A é definida na parte inferior do duto de ventilação principal ao longo da direção do comprimento do túnel. Como o dispositivo de filtragem de ar em comunicação com a entrada de ar é disposto no duto de ventilação principal em uma posição adjacente à entrada de ar, o ar que entra no duto de ventilação principal a partir da entrada de ar é filtrado em uma câmara de filtro de ar e depois seco em uma câmara de secagem de ar, após o que entra na cavidade interna do túnel através das saídas de ar A; o ar limpo filtrado entra na cavidade interna do túnel, alcançando assim o objetivo de reduzir efetivamente a descarga de poluentes.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Estação médica de lavagem de mãos com múltiplos postos (Modelo de Utilidade CN 209003741 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/multi-station-medical-hand-washing-station/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/multi-station-medical-hand-washing-station/</guid>
				<description>&lt;h2 id=&#34;visão-geral&#34;&gt;Visão Geral&lt;/h2&gt;&#xA;&lt;p&gt;Esta página aborda a patente de modelo de utilidade &lt;strong&gt;CN 209003741 U&lt;/strong&gt; (nº de pedido 201820895099.X, depositado em 2018-06-11, concedido em 2019-06-21), de propriedade da &lt;strong&gt;Dongguan Pengchi Purification Technology Co., Ltd.&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;A invenção é uma &lt;strong&gt;estação de lavagem de mãos médica de múltiplos postos&lt;/strong&gt; para departamentos cirúrgicos hospitalares. Ela é composta por um armário de base, um corpo de bacia de lavagem de mãos de múltiplas posições, &lt;em&gt;n&lt;/em&gt; torneiras com sensor (&lt;em&gt;n&lt;/em&gt; ≥ 2), um espelho de corpo inteiro e uma borda frontal ondulada formada por &lt;strong&gt;reentrâncias de acomodação&lt;/strong&gt; e &lt;strong&gt;saliências separadoras&lt;/strong&gt; alternadas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Estrutura de caixa redutora de ruído para teto de insuflamento de ar (Modelo de Utilidade CN 210141688 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920993183-a_noise-reducing_box_structure_for_supply_air_ceiling-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920993183-a_noise-reducing_box_structure_for_supply_air_ceiling-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade proporciona uma estrutura de caixa redutora de ruído para teto de insuflamento de ar, compreendendo um corpo de caixa de teto, em que o corpo da caixa do teto compreende uma placa envolvente retangular, uma placa de cobertura e uma placa perfurada; a placa de cobertura é instalada correspondentemente sobre uma superfície superior da placa envolvente, e a placa perfurada é instalada correspondentemente sobre uma superfície inferior da placa envolvente; saídas de ar de insuflamento são formadas em duas superfícies laterais opostas da placa envolvente, uma interface para pendente médico é disposta em uma posição central no interior da placa envolvente, e a interface para pendente médico atravessa a placa de cobertura e a placa perfurada, respectivamente; placas divisórias são instaladas na placa envolvente, em ambos os lados da interface para pendente médico, e as placas divisórias dividem a placa envolvente em dois espaços para instalação de filtros de ar; duas superfícies laterais da placa envolvente adjacentes às saídas de ar de insuflamento compreendem, cada uma, uma parede externa e uma parede interna, uma camada intermediária oca é formada entre a parede interna e a parede externa, uma estrutura de isolamento acústico é disposta na camada intermediária oca, a estrutura de isolamento acústico compreende um quadro de suporte em forma de grade, sendo o quadro interno do quadro de suporte dotado sucessivamente, de dentro para fora, de uma primeira camada de isolamento acústico e de uma segunda camada de isolamento acústico; e a parede interna da camada intermediária oca é revestida com uma camada de material de gesso. Por meio da disposição da estrutura de isolamento acústico, a função de redução de ruído do produto é aprimorada.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Estrutura de Proteção para Entrada de Ar de Capela de Fluxo Laminar (Modelo de Utilidade CN 210302877 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920992527-a_protection_structure_for_air_inlet_of_laminar_flow_hood-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920992527-a_protection_structure_for_air_inlet_of_laminar_flow_hood-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estrutura de proteção para a entrada de ar de uma cabine de fluxo laminar, compreendendo um corpo da cabine de fluxo laminar. A estrutura de proteção é caracterizada por uma entrada de ar circular disposta na superfície superior do corpo da cabine de fluxo laminar, com uma estrutura de proteção correspondentemente instalada na entrada de ar; a estrutura de proteção é composta por uma coifa de ventilação e uma estrutura filtrante; a coifa de ventilação é em forma de cruz; cada uma das quatro extremidades da coifa de ventilação conta com uma abertura; todas as aberturas comunicam-se entre si para formar um espaço de captação de ar; uma face de extensão circular é disposta na superfície inferior da coifa de ventilação; a estrutura filtrante compreende um corpo tubular circular correspondente à entrada de ar; uma malha filtrante de fibra de carbono, uma malha filtrante primária e uma malha filtrante HEPA são dispostas sequencialmente no interior do corpo tubular circular, de cima para baixo; a parte superior do corpo tubular é conectada por rosca à face de extensão; e a superfície inferior da coifa de ventilação comunica-se com o corpo tubular. A estrutura de entrada de ar lateral evita que poeira e detritos caiam diretamente na entrada de ar, melhorando assim a limpeza da cavidade interna da cabine de fluxo laminar.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Estrutura de Saída de Fornecimento de Ar do Tipo de Ligação (Modelo de Utilidade CN 210141677 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920992528-a_linkage-type_air_supply_outlet_structure-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920992528-a_linkage-type_air_supply_outlet_structure-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estrutura de saída de ar de alimentação de tipo interligado, compreendendo uma carcaça externa. Uma estrutura de malha filtrante primária, uma estrutura de malha filtrante HEPA e uma estrutura de feltro de fibra de carbono são dispostas sequencialmente no interior da carcaça externa. A carcaça externa compreende uma primeira seção de montagem e uma segunda seção de montagem. A estrutura de malha filtrante primária compreende uma moldura de montagem A e uma malha filtrante primária, sendo que pinos salientes são dispostos em todas as quatro bordas laterais da moldura de montagem A. A estrutura de malha filtrante HEPA compreende uma moldura de montagem B e uma malha filtrante HEPA; quatro braços de ligação se estendem da moldura de montagem B na direção da moldura de montagem A, um furo passante é disposto na extremidade de cada braço de ligação, e os pinos salientes são inseridos correspondentemente nos respectivos furos passantes. A estrutura de feltro de fibra de carbono compreende uma moldura de montagem C e um bloco de feltro de fibra de carbono; a moldura de montagem C é dotada de blocos salientes, e a moldura de montagem B é dotada de ranhuras reservadas. Vários parafusos são dispostos na carcaça externa nas posições correspondentes à moldura de montagem B, e cada parafuso se estende para o interior da carcaça externa para fixar os blocos salientes e a moldura de montagem B. Braços de ligação são dispostos entre a malha filtrante HEPA e a malha filtrante primária, realizando assim uma estrutura interligada e facilitando a desmontagem e a instalação.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Estrutura de Teto de Insuflamento de Fluxo Laminar Tipo Torre (Modelo de Utilidade CN 211400126 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201922167948-a_tower-type_laminar_flow_supply_ceiling_structure-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201922167948-a_tower-type_laminar_flow_supply_ceiling_structure-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estrutura de teto de fornecimento de ar em fluxo laminar tipo torre, compreendendo um corpo de caixa, cuja parede lateral é dotada de uma entrada de ar, cuja base é dotada de uma saída de ar e de uma placa de montagem de lâmpada sem sombra, e cujo interior é dotado de um sensor de pressão diferencial e de um sensor de qualidade do ar; um filtro é disposto entre a entrada de ar e a saída de ar, a saída de ar é dotada de uma placa equalizadora de fluxo, uma posição central da placa equalizadora de fluxo é dotada de um furo de passagem de lâmpada, e a placa de montagem de lâmpada sem sombra está diretamente oposta ao furo de passagem de lâmpada; uma placa transmissora de luz circunda a base da placa equalizadora de fluxo, e um painel de lâmpadas emissoras de luz circunda o corpo de caixa. O presente modelo de utilidade pode controlar efetivamente a faixa de saída do fluxo de ar limpo; o fluxo de ar limpo é altamente direcionado e tem alta taxa de utilização, de modo que a limpeza da área-alvo seja melhor garantida; os painéis de lâmpadas emissoras de luz ao redor permitem uma complementação eficaz da iluminação, e tanto a pressão quanto a limpeza do fluxo de ar limpo no interior do teto podem ser efetivamente monitoradas, o que garante efetivamente o efeito de fornecimento de ar de toda a estrutura de teto.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Filtro de Ar Tipo Cartucho (Modelo de Utilidade CN 210302891 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920993128-a_cartridge-type_air_filter-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920993128-a_cartridge-type_air_filter-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um filtro de ar tipo cartucho, que compreende um primeiro corpo de tampa e um segundo corpo de tampa. Uma manga e uma haste de conexão são dispostas entre o primeiro e o segundo corpo de tampa; no centro do segundo corpo de tampa é fornecido um furo de montagem para passagem da haste de conexão; na parte externa da outra extremidade da haste de conexão é conectada uma tampa rosqueada; na manga é disposto um entalhe em forma de V, uma malha metálica é fornecida em uma face lateral interna do entalhe em forma de V, e a haste de conexão está localizada na parte inferior do entalhe em forma de V; na parte posterior da manga são dispostas uma pluralidade de primeiras aberturas de passagem de ar; no interior da manga são dispostas, em sequência, uma camada filtrante de superfície porosa, uma camada de adsorção de carvão ativado, uma camada resistente a óleo, uma camada antibacteriana e uma camada de malha de náilon; a haste de conexão possui estrutura oca em seu interior, em sua superfície são dispostas uma pluralidade de segundas aberturas de passagem de ar, e no interior da haste são colocadas uma pluralidade de pastilhas perfumadas desodorizantes em forma de tira. O filtro de ar do presente modelo de utilidade apresenta excelente efeito de filtragem, estrutura simples e é fácil de desmontar para limpeza ou substituição.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Filtro de Fotólise Aprimorado (Modelo de Utilidade CN 210302875 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920992502-a_improved_photolysis_filter-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920992502-a_improved_photolysis_filter-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um filtro de fotólise melhorado, que compreende uma carcaça. A carcaça compreende uma extremidade de entrada de ar e uma extremidade de saída de ar. Na carcaça são dispostas sequencialmente uma primeira camada divisória metálica, uma primeira camada de tecido plissado, uma camada de elemento filtrante, uma camada absorvente de água, uma camada de fotólise, uma camada filtrante de fotocatalisador, uma segunda camada de tecido plissado e uma segunda camada divisória metálica. A camada de fotólise compreende uma moldura externa, uma pluralidade de primeiros capuzes de reflexão e segundos capuzes de reflexão fixados na carcaça, e lâmpadas ultravioletas fixadas nas faces internas dos primeiros capuzes de reflexão. Os primeiros capuzes de reflexão e os segundos capuzes de reflexão estão intercalados em intervalos e dispostos opostamente entre si. A camada filtrante de fotocatalisador compreende tecido de náilon e partículas de dióxido de titânio em escala nanométrica revestidas no tecido de náilon. O filtro fornecido pelo presente modelo de utilidade apresenta bom efeito de filtragem e bom efeito de esterilização.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Gestão da Qualidade ISO9001 2026</title>
				<link>https://pengchi.net/pt/docs/downloads/certs/quality-management-iso9001-2026-2/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/certs/quality-management-iso9001-2026-2/</guid>
				<description>&lt;h2&gt;CERTIFICADO&#xA;Requisitos do Sistema de Gestão da Qualidade&#xA;GB/T 19001-2016 / ISO 9001:2015&lt;/h2&gt;&#xA;&lt;p&gt;Signatário Autorizado&#xA;Consulta do Certificado&lt;/p&gt;&#xA;&lt;p&gt;ACM INTERNATIONAL CERTIFICATION LIMITED, 63 St Mary Axe, Londres, Inglaterra, EC3A 8AA, Reino Unido&#xA;Escritório Local - ACM (CHINA) LIMITED, Sala B201, Edifício 2, N.º 352, Estrada Waihuan, Distrito de Minhang, Xangai 201199, China&lt;/p&gt;&#xA;&lt;p&gt;Tel.: +86 21-64305860 Site: &lt;a href=&#34;https://www.acmcert.com.cn&#34;&gt;www.acmcert.com.cn&lt;/a&gt; E-mail: &lt;a href=&#34;mailto:info@acmcert.com.cn&#34;&gt;info@acmcert.com.cn&lt;/a&gt;&lt;/p&gt;&#xA;&lt;p&gt;IAF 17/23&lt;/p&gt;&#xA;&lt;p&gt;Certifica-se pelo presente que o sistema de gestão da qualidade estabelecido e implementado pela organização acima mencionada cumpre os requisitos da norma.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Lavatório (Dois Postos) (Desenho Industrial CN 304882371 S)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201830291758-a_wash_basin_two-station-design/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201830291758-a_wash_basin_two-station-design/</guid>
				<description>&lt;h2 id=&#34;informações-do-produto&#34;&gt;Informações do Produto&lt;/h2&gt;&#xA;&lt;table&gt;&#xA;&#x9;&lt;thead&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Item&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Detalhe&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/thead&gt;&#xA;&#x9;&lt;tbody&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Autoridade emissora&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Administração Nacional de Propriedade Intelectual da República Popular da China (CNIPA)&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Tipo de documento&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Patente de Desenho Industrial&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Número de publicação da concessão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;CN 304882371 S&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Data de publicação da concessão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2018.11.06&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Número do pedido&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;201830291758.4&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Data do depósito&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2018.06.11&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Titular da patente&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Dongguan Pengchi Purification Technology Co., Ltd.&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Endereço&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Rua Tangyilangwei, Vila Tangjiao, Município de Chashan, Cidade de Dongguan, Província de Guangdong 523378, China&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Designers&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Wang Haiou; Hu Guopeng; Li Dexiong&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Agência de patentes&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Dongguan Yongqiao Intellectual Property Agency (Sociedade em Nome Coletivo), Código 44400&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Agente de patentes&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;He Xinhua&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classificação de Locarno&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;23-02&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Nome do produto&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Lavatório (Dois Postos)&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;h2 id=&#34;breve-declaração&#34;&gt;Breve Declaração&lt;/h2&gt;&#xA;&lt;ol&gt;&#xA;&lt;li&gt;Nome do produto: Lavatório (Dois Postos).&lt;/li&gt;&#xA;&lt;li&gt;Uso: O produto deste desenho é utilizado para lavagem.&lt;/li&gt;&#xA;&lt;li&gt;Ponto característico do desenho: O ponto característico do produto reside em sua forma geral.&lt;/li&gt;&#xA;&lt;li&gt;A imagem que melhor apresenta os pontos característicos do desenho é a vista em perspectiva.&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;h2 id=&#34;vistas&#34;&gt;Vistas&lt;/h2&gt;&#xA;&lt;p&gt;&lt;img src=&#34;https://pengchi.net/media/pdf/patents/figures/CN201830291758/fig1.png&#34; alt=&#34;Vista frontal&#34;&gt;&#xA;&lt;em&gt;Vista frontal&lt;/em&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Lavatório (Três Postos) (Desenho Industrial CN 304999383 S)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201830291756-a_wash_basin_three-station-design/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201830291756-a_wash_basin_three-station-design/</guid>
				<description>&lt;h2 id=&#34;informações-do-produto&#34;&gt;Informações do Produto&lt;/h2&gt;&#xA;&lt;table&gt;&#xA;&#x9;&lt;thead&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Ítem&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Detalhe&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/thead&gt;&#xA;&#x9;&lt;tbody&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Autoridade emissora&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Administração Nacional da Propriedade Intelectual da República Popular da China (CNIPA)&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Tipo de documento&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Patente de Desenho Industrial&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Número de publicação da concessão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;CN 304999383 S&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Data de publicação da concessão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2019.01.15&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Número do pedido&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;201830291756.5&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Data de depósito&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2018.06.11&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Titular da patente&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Dongguan Pengchi Purification Technology Co., Ltd.&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Endereço&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Rua Tangyilangwei, Aldeia Tangjiao, Vila de Chashan, Cidade de Dongguan, Província de Guangdong 523378, China&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Projetistas&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Wang Haiou; Hu Guopeng; Li Dexiong&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Agência de patentes&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Dongguan Yongqiao Intellectual Property Agency (Sociedade de Parceria Geral), Código 44400&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Agente de patentes&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;He Xinhua&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classificação de Locarno&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;23-02&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Nome do produto&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Bacia de Lavagem (Três Postos)&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;h2 id=&#34;declaração-resumida&#34;&gt;Declaração Resumida&lt;/h2&gt;&#xA;&lt;ol&gt;&#xA;&lt;li&gt;Nome do produto: Bacia de Lavagem (Três Postos).&lt;/li&gt;&#xA;&lt;li&gt;Uso: O produto deste desenho é destinado à lavagem.&lt;/li&gt;&#xA;&lt;li&gt;Ponto característico do desenho: O ponto característico do desenho do produto reside na sua forma global.&lt;/li&gt;&#xA;&lt;li&gt;A imagem que melhor demonstra os pontos característicos do desenho é a vista em perspectiva.&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;h2 id=&#34;vistas&#34;&gt;Vistas&lt;/h2&gt;&#xA;&lt;p&gt;&lt;img src=&#34;https://pengchi.net/media/pdf/patents/figures/CN201830291756/fig1.png&#34; alt=&#34;Vista frontal&#34;&gt;&#xA;&lt;em&gt;Vista frontal&lt;/em&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Lavatório de mãos acionado pelo joelho (Modelo de Utilidade CN 210315823 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920993181-a_knee-operated_hand-washing_basin-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920993181-a_knee-operated_hand-washing_basin-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade oferece uma pia de lavagem de mãos operada por joelho, compreendendo uma base e uma placa traseira, em que uma pia de lavagem de mãos é disposta sobre a base, uma torneira é instalada na parte superior da pia de lavagem de mãos, uma válvula de controle elétrico é conectada à parte inferior da torneira, um painel basculante acionado por joelho é disposto na extremidade dianteira da base, a extremidade inferior do painel basculante acionado por joelho é conectada de forma rotativa à base, um conjunto de controle por joelho é disposto na face interna da extremidade superior do painel basculante acionado por joelho, e o conjunto de controle por joelho é eletricamente conectado à válvula de controle elétrico; um painel basculante acionado por pé também é disposto na extremidade dianteira da base, a extremidade inferior do painel basculante acionado por pé é conectada de forma rotativa à base, e um conjunto de controle por pé é disposto na face interna da extremidade superior do painel basculante acionado por pé; um trilho guia e um cilindro de ar também são dispostos no interior da base, uma caixa móvel é conectada de forma deslizante ao trilho guia, a extremidade de saída do cilindro de ar é conectada de forma fixa a uma das extremidades da caixa móvel, e o conjunto de controle por pé é eletricamente conectado ao cilindro de ar. Com a pia de lavagem de mãos operada por joelho do presente modelo de utilidade, o usuário pode ficar em frente à pia e controlar a abertura e o fechamento da torneira por meio do joelho, evitando a contaminação secundária das mãos após a lavagem.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Normas ISO para salas cirúrgicas modulares</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/construction-acceptance/modular-operating-room-iso-standards/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/construction-acceptance/modular-operating-room-iso-standards/</guid>
				<description>&lt;h1 id=&#34;normas-iso-relacionadas-às-salas-cirúrgicas-modulares-modular-or&#34;&gt;Normas ISO Relacionadas às Salas Cirúrgicas Modulares (Modular OR)&lt;/h1&gt;&#xA;&lt;blockquote&gt;&#xA;&lt;p&gt;&lt;strong&gt;Fato-chave:&lt;/strong&gt; A ISO não possui uma norma única dedicada especificamente às &amp;ldquo;Salas Cirúrgicas Modulares&amp;rdquo;. Uma sala cirúrgica modular baseia-se principalmente numa combinação de &lt;strong&gt;tecnologia de sala limpa (ISO 14644) + requisitos de ventilação médica + sistemas de gases medicinais + normas de segurança elétrica&lt;/strong&gt;.&#xA;Os requisitos típicos de limpeza para salas cirúrgicas são &lt;strong&gt;Classe ISO 5 para o campo operatório&lt;/strong&gt; e &lt;strong&gt;Classe ISO 7 para as áreas circundantes&lt;/strong&gt;.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Relatório de Auditoria TÜV Rheinland</title>
				<link>https://pengchi.net/pt/docs/downloads/test-reports/tuv-rheinland-audit-report/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/test-reports/tuv-rheinland-audit-report/</guid>
				<description>&lt;p&gt;Relatório de Auditoria TÜV Rheinland N.º: MIC-ASI2521094&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sistemas de Gestão Ambiental ISO 2026</title>
				<link>https://pengchi.net/pt/docs/downloads/certs/environmental-management-systems-iso-2026/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/certs/environmental-management-systems-iso-2026/</guid>
				<description>&lt;p&gt;&lt;strong&gt;CERTIFICADO&lt;/strong&gt;&lt;br&gt;&#xA;&lt;strong&gt;Sistemas de Gestão Ambiental - Requisitos com Orientações para Uso&lt;/strong&gt;&lt;br&gt;&#xA;GB/T 24001-2016 / ISO 14001:2015&lt;/p&gt;&#xA;&lt;p&gt;Signatário Autorizado | Consulta de Certificado&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;ACM INTERNATIONAL CERTIFICATION LIMITED&lt;/strong&gt;&lt;br&gt;&#xA;63 St Mary Axe, Londres, Inglaterra, EC3A 8AA, Reino Unido&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Escritório Local - ACM (CHINA) LIMITED&lt;/strong&gt;&lt;br&gt;&#xA;Sala B201, Edifício 2, Nº 352, Rua Waihuan, Distrito de Minhang, Xangai 201199, China&lt;/p&gt;&#xA;&lt;p&gt;Telefone: +86 21-64305860&lt;br&gt;&#xA;Site: &lt;a href=&#34;https://www.acmcert.com.cn&#34;&gt;www.acmcert.com.cn&lt;/a&gt;&lt;br&gt;&#xA;E-mail: &lt;a href=&#34;mailto:info@acmcert.com.cn&#34;&gt;info@acmcert.com.cn&lt;/a&gt;&lt;/p&gt;&#xA;&lt;p&gt;IAF 17/23&lt;/p&gt;&#xA;&lt;p&gt;Certifica-se que o sistema de gestão ambiental estabelecido e implementado pela organização acima mencionada cumpre os requisitos da norma. O presente certificado é válido para utilização no âmbito das diversas licenças administrativas e de qualificação estipuladas pelo Estado e dentro do seu período de vigência. Durante o período de validade do certificado, deve ser realizada uma auditoria de supervisão uma vez por ano; mediante aprovação na auditoria, o certificado permanecerá válido. O certificado pode ser consultado no site do organismo de certificação (&lt;a href=&#34;https://www.acmcert.com.cn&#34;&gt;www.acmcert.com.cn&lt;/a&gt;) e no site da CNCA (&lt;a href=&#34;https://www.cnca.gov.cn&#34;&gt;www.cnca.gov.cn&lt;/a&gt;).&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sistemas de Gestão de Saúde e Segurança Ocupacional ISO 2026</title>
				<link>https://pengchi.net/pt/docs/downloads/certs/occupational-health-and-safety-managementsystems-iso-2026/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/certs/occupational-health-and-safety-managementsystems-iso-2026/</guid>
				<description>&lt;h1 id=&#34;certificado&#34;&gt;CERTIFICADO&lt;/h1&gt;&#xA;&lt;h2 id=&#34;sistemas-de-gestão-da-segurança-e-saúde-no-trabalho--requisitos-com-orientações-para-utilização&#34;&gt;Sistemas de Gestão da Segurança e Saúde no Trabalho — Requisitos com Orientações para Utilização&lt;/h2&gt;&#xA;&lt;h3 id=&#34;gbt-45001-2020--iso-450012018&#34;&gt;GB/T 45001-2020 / ISO 45001:2018&lt;/h3&gt;&#xA;&lt;p&gt;&lt;strong&gt;Signatário Autorizado&lt;/strong&gt;&lt;br&gt;&#xA;&lt;strong&gt;Consulta de Certificado&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;ACM INTERNATIONAL CERTIFICATION LIMITED, 63 St Mary Axe, Londres, Inglaterra, EC3A 8AA, Reino Unido&lt;br&gt;&#xA;Escritório Local - ACM (CHINA) LIMITED, Sala B201, Edifício 2, Nº 352, Estrada Waihuan, Distrito de Minhang, Xangai 201199, China&lt;/p&gt;&#xA;&lt;p&gt;T: +86 21-64305860 W: &lt;a href=&#34;https://www.acmcert.com.cn&#34;&gt;www.acmcert.com.cn&lt;/a&gt; E: &lt;a href=&#34;mailto:info@acmcert.com.cn&#34;&gt;info@acmcert.com.cn&lt;/a&gt; IAF 17/23&lt;/p&gt;&#xA;&lt;p&gt;Por meio deste, certifica-se que o sistema de gestão da segurança e saúde no trabalho estabelecido e implementado pela organização acima cumpre os requisitos da norma. O presente certificado é válido para utilização no âmbito das diversas licenças administrativas e de qualificação estipuladas pelo Estado, dentro de seu período de vigência. Durante o período de vigência do certificado, a auditoria de supervisão deve ser realizada uma vez por ano; mediante aprovação na auditoria, o certificado permanecerá válido. O certificado pode ser consultado no site do organismo de certificação (&lt;a href=&#34;https://www.acmcert.com.cn&#34;&gt;www.acmcert.com.cn&lt;/a&gt;)&lt;/p&gt;</description>
			</item>
			<item>
				<title>Teto de Fluxo Laminar (Dedicado para Sala Cirúrgica) (Desenho Industrial CN 305854446 S)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201930678863-a_laminar_flow_ceiling_operating_room_dedicated-design/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201930678863-a_laminar_flow_ceiling_operating_room_dedicated-design/</guid>
				<description>&lt;h2 id=&#34;informações-do-produto&#34;&gt;Informações do Produto&lt;/h2&gt;&#xA;&lt;table&gt;&#xA;&#x9;&lt;thead&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Item&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Detalhe&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/thead&gt;&#xA;&#x9;&lt;tbody&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Autoridade emissora&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Administração Nacional da Propriedade Intelectual da República Popular da China (CNIPA)&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Tipo de documento&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Patente de Desenho Industrial&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Número de publicação da concessão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;CN 305854446 S&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Data de publicação da concessão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2020.06.16&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Número de pedido&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;201930678863.8&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Data de depósito&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2019.12.05&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Titular da patente&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Dongguan Pengchi Tecnologia de Purificação Ltda.&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Endereço&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Rua Tangyilangwei, Aldeia Tangjiao, Vila de Chashan, Cidade de Dongguan, Província de Guangdong 523378, China&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Designers&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Li Dexiong; Hu Guopeng; Wang Haiou&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Agência de patentes&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Agência de Propriedade Intelectual Yongqiao de Dongguan (Sociedade em Nome Coletivo), Código 44400&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Agente de patentes&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Jiang Yabing&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classificação de Locarno&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;25-02&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Nome do produto&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Teto de Fluxo Laminar (Especial para Sala de Operações)&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;h2 id=&#34;declaração-breve&#34;&gt;Declaração Breve&lt;/h2&gt;&#xA;&lt;ol&gt;&#xA;&lt;li&gt;Nome do produto: Teto de Fluxo Laminar (Especial para Sala de Operações).&lt;/li&gt;&#xA;&lt;li&gt;Utilização: Utilizado em conjunto com um filtro de ar, o produto fornece suprimento de ar limpo em salas de operação.&lt;/li&gt;&#xA;&lt;li&gt;Ponto característico do desenho: O ponto característico do desenho do produto reside na sua forma global.&lt;/li&gt;&#xA;&lt;li&gt;A imagem que melhor demonstra os pontos característicos do desenho é a vista em perspectiva.&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;h2 id=&#34;vistas&#34;&gt;Vistas&lt;/h2&gt;&#xA;&lt;p&gt;&lt;img src=&#34;https://pengchi.net/media/pdf/patents/figures/CN201930678863/fig1.png&#34; alt=&#34;Vista frontal&#34;&gt;&#xA;&lt;em&gt;Vista frontal&lt;/em&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um Carrinho de Amostragem Aprimorado (Modelo de Utilidade CN 210322339 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920992504-a_improved_sampling_cart-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920992504-a_improved_sampling_cart-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um carrinho de amostragem aprimorado, que compreende um invólucro. O interior do invólucro é dividido por uma partição vertical em um compartimento de equipamentos e um compartimento de armazenamento. No interior do compartimento de equipamentos, são dispostos sequencialmente da esquerda para a direita um soprador, uma camada de malha filtrante de carvão ativado e um filtro HEPA. A partição vertical é dotada de uma abertura que comunica o compartimento de equipamentos com o compartimento de armazenamento. Um duto de ventilação é disposto entre o invólucro e as paredes externas do compartimento de equipamentos e do compartimento de armazenamento, e uma parede externa do compartimento de armazenamento é dotada de uma abertura que comunica com o duto de ventilação. Uma entrada de ar é disposta em uma posição correspondente ao soprador, na parte superior do invólucro, e o duto de ventilação comunica-se com a entrada de ar. O invólucro é fechado por um painel de fechamento frontal, um painel de fechamento traseiro, um painel de fechamento lateral, um painel de fechamento superior, uma placa inferior e uma porta deslizante esquerda-direita. Cada um do painel de fechamento frontal, do painel de fechamento traseiro, do painel de fechamento lateral e do painel de fechamento superior compreende sequencialmente, de fora para dentro, uma camada retardante de chama, uma placa metálica, uma camada de isolamento acústico e uma camada de isolamento térmico. Rodízios universais são montados na parte inferior da placa inferior. Por meio do ajuste da estrutura do invólucro, o carrinho de amostragem possui funções de retardamento de chama, isolamento acústico e isolamento térmico.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um Chuveiro de Ar com Intertravamento de Três Portas (Modelo de Utilidade CN 210304871 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920992497-a_three-door_interlocking_air_shower-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920992497-a_three-door_interlocking_air_shower-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um chuveiro de ar com intertravamento de três portas, que compreende uma caixa de chuveiro de ar. Um painel de porta frontal, um painel de porta esquerdo e um painel de porta direito são dispostos respectivamente na extremidade frontal, na extremidade esquerda e na extremidade direita da caixa do chuveiro de ar. Um primeiro dispositivo eletrônico de intertravamento, um segundo dispositivo eletrônico de intertravamento e um terceiro dispositivo eletrônico de intertravamento são dispostos na caixa do chuveiro de ar. Uma pluralidade de ventiladores é disposta na extremidade superior da caixa do chuveiro de ar, um filtro primário é disposto na parte inferior de cada ventilador, e uma placa respirável de isolamento de poeira é disposta na parte inferior do filtro primário. Um primeiro conjunto de saída de ar e um segundo conjunto de saída de ar são dispostos respectivamente nos lados esquerdo e direito abaixo da placa respirável de isolamento de poeira. Um emissor infravermelho é fixado a um lado do primeiro conjunto de saída de ar, e um receptor infravermelho oposto ao emissor infravermelho é fixado a um lado do segundo conjunto de saída de ar. O chuveiro de ar com intertravamento de três portas fornecido pelo presente modelo de utilidade apresenta bom efeito de limpeza e alta eficiência de remoção de poeira.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um Chuveiro de Ar Rotativo de Alta Eficiência (Modelo de Utilidade CN 210304872 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920997733-a_high-efficiency_rotary_air_shower-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920997733-a_high-efficiency_rotary_air_shower-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um chuveiro de ar rotativo de alta eficiência, compreendendo um corpo de caixa, em que painéis de porta são dispostos em ambas as extremidades dianteira e traseira do corpo de caixa, um ventilador é disposto em uma extremidade superior do corpo de caixa, um tanque de filtragem é disposto em um lado inferior do ventilador, uma primeira tela de filtro e uma segunda tela de filtro são dispostas no tanque de filtragem, um primeiro conjunto de descarga de ar e um segundo conjunto de descarga de ar são dispostos em ambos os lados internos do corpo de caixa, um emissor infravermelho é fixado em um lado do primeiro conjunto de descarga de ar, um receptor infravermelho é fixado em um lado do segundo conjunto de descarga de ar, um motor rotativo é ainda disposto no fundo de um lado interno do corpo de caixa, uma extremidade de saída do motor rotativo é conectada a uma placa rotativa, uma pluralidade de hastes de suporte é conectada à placa rotativa, uma barra de corrimão em forma de arco é conectada às extremidades superiores das hastes de suporte, a barra de corrimão em forma de arco é provida de uma porção de corrimão, o interior da porção de corrimão é de estrutura oca, uma pluralidade de furos de ventilação é disposta em ambos os lados de uma extremidade superior da porção de corrimão, e um terceiro conjunto de descarga de ar é conectado a uma extremidade inferior da porção de corrimão. O chuveiro de ar do presente modelo de utilidade possui bom efeito de limpeza e alta eficiência de remoção de poeira.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um Filtro de Carvão Ativado (Modelo de Utilidade CN 208382422 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201821018235-a_activated_carbon_filter-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201821018235-a_activated_carbon_filter-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um filtro de carvão ativado, que compreende uma carcaça, em que a carcaça inclui uma extremidade de entrada de ar e uma extremidade de saída de ar; um tubo de saída de ar está disposto na extremidade de saída de ar; uma placa de vidro transparente está instalada na extremidade superior interna da carcaça; o lado superior da placa de vidro transparente forma uma primeira ranhura de montagem, e o lado inferior forma uma segunda ranhura de montagem; uma lâmpada esterilizadora ultravioleta está suspensa na primeira ranhura de montagem; uma camada de malha de carvão ativado, uma camada de fibra de algodão, uma camada filtrante de fotocatalisador, uma camada de absorção de óleo e um ventilador estão dispostos sequencialmente na segunda ranhura de montagem; um dispositivo emissor de fragrância está ainda instalado no lado inferior do ventilador; e um conjunto raspador de poeira está disposto no lado da camada de malha de carvão ativado afastado da camada de fibra de algodão. O filtro de carvão ativado do presente modelo de utilidade pode realizar a filtragem de ar de forma eficiente, e está adicionalmente equipado com a lâmpada esterilizadora ultravioleta e o dispositivo emissor de fragrância, de modo que o filtro conta com função de esterilização e função de melhoria da qualidade do ar.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um filtro primário ignífugo (Modelo de Utilidade CN 208493605 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201821018233-a_flame-retardant_primary_filter-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201821018233-a_flame-retardant_primary_filter-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um filtro primário ignífugo, que compreende uma moldura externa, na qual uma primeira camada de malha, uma camada de fibra de vidro, uma camada de elemento filtrante, uma camada de almofada protetora e uma segunda camada de malha são empilhadas sequencialmente; três ranhuras são formadas em um lado da camada de elemento filtrante voltado para a camada de almofada protetora; sacos alongados são colocados nas ranhuras; e os sacos alongados estão cheios de líquido ignífugo. O filtro primário do presente modelo de utilidade pode ser instalado na abertura de ventilação de um dispositivo de ar condicionado; em comparação com um filtro primário tradicional, foi adicionada uma camada de fibra de vidro no lado inferior da camada de elemento filtrante, e o ponto de fusão da fibra de vidro é relativamente alto, de modo que a combustão do filtro pode ser efetivamente retardada; três sacos alongados cheios de líquido ignífugo foram adicionados na parte traseira do lado inferior da camada de elemento filtrante e, ao encontrar fogo, os sacos alongados derretem e o líquido ignífugo se infiltra rapidamente na camada de elemento filtrante para impedir a propagação do fogo, com um bom efeito ignífugo.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um Filtro Primário Separador de Óleo (Modelo de Utilidade CN 210302876 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920992508-a_oil-separating_primary_filter-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920992508-a_oil-separating_primary_filter-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um filtro primário separador de óleo, compreendendo um corpo de caixa e uma placa de cobertura dianteira. O corpo de caixa compreende uma extremidade de entrada de ar e uma extremidade de saída de ar. Uma placa de grade é fixada em uma extremidade do corpo de caixa e está disposta no lado próximo à extremidade de saída de ar. Uma ranhura de folga é fornecida no lado interno da outra extremidade do corpo de caixa, e uma placa de separação de óleo é disposta na ranhura de folga. A placa de separação de óleo compreende uma moldura externa e uma pluralidade de placas defletoras inclinadas fixadas no lado interno da moldura externa, com um intervalo entre cada duas placas defletoras inclinadas. Uma camada de adsorção de carvão ativado, uma camada de elemento filtrante e uma camada plissada são sequencialmente dispostas entre a placa de separação de óleo e a placa de grade. Uma extremidade dianteira da placa de cobertura dianteira é fornecida com uma pluralidade de saliências em forma de guarda-chuva, e uma borda inferior de cada saliência em forma de guarda-chuva é fornecida com uma pluralidade de orifícios permeáveis ao ar. O filtro primário do presente modelo de utilidade pode bloquear a maior parte do líquido oleoso e impedir que ele entre no elemento filtrante, prolongando assim a vida útil do elemento filtrante.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um novo tipo de saída de suprimento de ar (Modelo de Utilidade CN 208504676 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201821017867-a_new-type_air_supply_outlet-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201821017867-a_new-type_air_supply_outlet-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma nova saída de insuflamento de ar, compreendendo uma caixa cilíndrica, uma placa difusora, um filtro e uma válvula reguladora, em que a válvula reguladora é conectada fixamente a uma entrada de ar da caixa cilíndrica; o filtro é conectado fixamente ao fundo da caixa cilíndrica; uma ranhura anular é formada na parede externa da caixa cilíndrica; a placa difusora está disposta abaixo da caixa cilíndrica; um cilindro compatível com a ranhura anular é conectado fixamente ao topo da placa difusora; o cilindro está disposto na ranhura anular e em conexão deslizante com a ranhura anular; uma pluralidade de furos de saída de ar são formados através do cilindro; uma abertura de elevação em comunicação com a ranhura anular é formada através de um lado da caixa cilíndrica; uma haste de impulso conectada fixamente a um lado do cilindro é inserida através da abertura de elevação; a abertura de elevação é compatível com a haste de impulso; um motor A é conectado fixamente a um lado da caixa cilíndrica; o motor A está em ligação por fuso roscado com a haste de impulso; e a haste de impulso se move para cima e para baixo ao longo da abertura de elevação sob o acionamento do motor A. A saída de insuflamento de ar tem estrutura simples e é conveniente de usar, pode ajustar automaticamente a área de saída de ar e melhora a eficiência de renovação do ar.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um Sistema de Ar Fresco para Garagens Subterrâneas de Múltiplos Níveis (Modelo de Utilidade CN 208504649 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201821018234-a_fresh-air_system_for_multi-level_underground_garages-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201821018234-a_fresh-air_system_for_multi-level_underground_garages-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um sistema de ar fresco para garagens subterrâneas de vários andares, compreendendo uma moldura externa, na qual uma câmara de entrada de ar e uma câmara de saída de ar são dispostas; um sistema de admissão de ar é instalado na abertura da câmara de entrada de ar; uma pluralidade de saídas de ar em comunicação com a câmara de entrada de ar é formada em paralelo através de um lado da moldura externa; portas móveis são articuladas nas saídas de ar; a câmara de entrada de ar compreende uma passagem transversal e uma passagem longitudinal em comunicação entre si; um bloco deslizante em conexão deslizante com a passagem longitudinal é disposto na mesma; uma passagem de fluxo é formada através do bloco deslizante; uma ranhura é feita em um lado do bloco deslizante; uma haste de impulso é alocada na ranhura; uma mola é fixada entre a haste de impulso e a ranhura; um motor é instalado na parte inferior da moldura externa; o bloco deslizante está conectado ao motor por parafuso de avanço e se move para cima e para baixo ao longo da passagem longitudinal sob acionamento do motor; uma pluralidade de placas de malha de saída de ar dispostas em paralelo são fixadas a um lado da moldura externa; e uma pluralidade de orifícios de saída de ar em comunicação com a câmara de saída de ar são formados através das placas de malha de saída de ar. É possível obter um efeito de saída de ar de alta velocidade sem utilizar um sistema de admissão de ar de alta potência, o que economiza energia efetivamente.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um Sistema de Ventilação de Ar Fresco para Cibercafés (Modelo de Utilidade CN 208382459 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201821017801-a_fresh-air_ventilation_system_for_internet_cafes-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201821017801-a_fresh-air_ventilation_system_for_internet_cafes-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um sistema de ventilação de ar fresco para cibercafés, composto por uma carcaça e uma tampa superior articulada a um lado da carcaça. A carcaça é dividida, por uma placa divisória conectada de forma fixa no interior da carcaça, em uma câmara de entrada de ar e uma câmara de saída de ar. Uma porta de admissão de ar em comunicação com a câmara de entrada de ar e uma porta de exaustão de ar em comunicação com a câmara de saída de ar são dispostas lado a lado através de um lado da carcaça. Um ventilador é conectado de forma fixa no interior da porta de admissão de ar. Um conjunto fotocatalítico é conectado de forma fixa na câmara de entrada de ar, sendo o conjunto fotocatalítico composto por um núcleo axial e placas de malha de dióxido de titânio fixadas lado a lado no núcleo axial. Um tubo de lâmpada ultravioleta é conectado de forma fixa na parte inferior da tampa superior, acima do conjunto fotocatalítico. Uma bandeja é conectada de forma fixa na câmara de entrada de ar, em um lado do conjunto fotocatalítico, e a bandeja contém uma essência refrescante. Uma saída de fornecimento de ar em comunicação com a câmara de entrada de ar é formada através de um lado da carcaça, e uma porta de saída de ar em comunicação com a câmara de saída de ar é formada através de um lado da carcaça, com um exaustor conectado de forma fixa no interior da porta de saída de ar. O sistema permite realizar a renovação do ar no cibercafé, eliminando efetivamente a proliferação de bactérias, germes e semelhantes no local, além de eliminar odores no cibercafé.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um visualizador de filmes de raios X para imagiologia médica (iluminador) (Modelo de Utilidade CN 210051967 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920806854-a_medical_imaging_x-ray_film_viewer_illuminator-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920806854-a_medical_imaging_x-ray_film_viewer_illuminator-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece um negatoscópio de raios X para imagem médica (iluminador), que compreende uma caixa de lâmpadas e uma tampa de caixa que cobre a extremidade superior da caixa de lâmpadas, em que uma cavidade é formada na caixa de lâmpadas; vários tubos de lâmpada estão dispostos na cavidade; a tampa da caixa compreende uma moldura externa, uma moldura interna e uma placa translúcida fixada no lado interno da moldura interna; a moldura externa é fixada na borda da extremidade superior da caixa de lâmpadas; uma extremidade da moldura interna está conectada rotacionalmente à caixa de lâmpadas, e a outra extremidade está conectada fixamente à caixa de lâmpadas; um pivô superior e um pivô inferior estão dispostos na conexão rotacional entre a moldura interna e a caixa de lâmpadas; uma mola é encaixada externamente ao pivô superior; e vários discos de atração magnética estão dispostos na placa translúcida. O negatoscópio de raios X para imagem médica (iluminador) do presente modelo de utilidade tem estrutura simples, apresenta bom efeito de visualização de filmes, permite que o filme de raios X seja instalado de forma conveniente e não seja danificado facilmente.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Bancada Limpa (Modelo de Utilidade CN 210752786 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920992507-a_clean_bench-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920992507-a_clean_bench-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma bancada limpa, que compreende uma bancada de trabalho. A bancada de trabalho é composta por uma zona de extração de ar, uma zona de operação e uma zona de controle por joelho. Um primeiro conjunto de acionamento também é fixado na extremidade superior da zona de extração de ar, uma extremidade de saída do primeiro conjunto de acionamento é conectada a um painel de cobertura frontal de vidro, e uma extremidade inferior do painel de cobertura frontal de vidro se estende para dentro da zona de operação. A zona de operação compreende uma primeira zona, uma segunda zona e uma terceira zona; uma primeira divisória de vidro é disposta entre a primeira zona e a segunda zona, e uma segunda divisória de vidro é disposta entre a segunda zona e a terceira zona. O presente modelo de utilidade fornece uma bancada limpa na qual a zona de operação é dividida em três zonas, e cada duas zonas são separadas por uma divisória de vidro capaz de se mover para cima e para baixo. Sob o controle dos conjuntos de controle por joelho, a zona de operação pode ser transformada em um, dois ou três espaços independentes, de modo que múltiplos experimentos podem ser realizados simultânea e independentemente uns dos outros.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Caixa de Controle de Tela de Exibição Médica (Modelo de Utilidade CN 210328259 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920993160-a_medical_display_screen_control_box-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920993160-a_medical_display_screen_control_box-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma caixa de controle de tela de exibição médica, compreendendo um corpo de caixa, em que o corpo de caixa compreende um primeiro compartimento, um segundo compartimento e um terceiro compartimento; um painel de exibição é disposto na extremidade dianteira do primeiro compartimento, a extremidade inferior do painel de exibição é conectada de forma rotacional ao corpo de caixa, um trinco de retorno elástico é disposto no lado interno da extremidade superior do painel de exibição, e um dispositivo de retorno elástico correspondente ao trinco de retorno elástico é disposto na extremidade superior do lado interno do primeiro compartimento; uma placa de montagem é disposta na extremidade dianteira do segundo compartimento, e um sensor de temperatura é fixado no lado interno da placa de montagem; e uma gaveta é disposta no terceiro compartimento. A caixa de controle de tela de exibição médica do presente modelo de utilidade adota uma estrutura embutida na parede, permitindo que o corpo da caixa seja instalado no interior de uma parede, sendo o painel de exibição então disposto no corpo da caixa; além disso, o painel de exibição pode ser aberto por pressão, de modo que um espaço de armazenamento relativamente grande é fornecido no interior do painel de exibição para facilitar o armazenamento de ferramentas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Estação Médica de Lavagem de Mãos com Múltiplos Postos (Modelo de Utilidade CN 209003741 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201820895099-a_multi-station_medical_hand-washing_station-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201820895099-a_multi-station_medical_hand-washing_station-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estação de lavagem de mãos médica de múltiplos postos, compreendendo uma base, um corpo de bacia de lavagem de mãos fixado na base e uma moldura de espelho fixada no corpo de bacia de lavagem de mãos. n torneiras de água são fixadas em uma parede lateral do corpo de bacia de lavagem de mãos adjacente à moldura do espelho, sendo n um número inteiro maior ou igual a 2. Uma parede lateral do corpo de bacia de lavagem de mãos afastada da moldura do espelho compreende uma pluralidade de reentrâncias e saliências de separação dispostas alternadamente, sendo fornecidas n reentrâncias, que correspondem às torneiras de água. Um espelho é fixado na moldura do espelho. O presente modelo de utilidade conta com uma estrutura de limitação de posição especial, capaz de controlar efetivamente as posições em pé de todas as pessoas que lavam as mãos e, ao mesmo tempo, separar efetivamente os usuários, de modo que uma distância dentro de um intervalo determinado seja mantida entre eles. Essa configuração evita efetivamente o contato físico entre as pessoas, impedindo assim a contaminação cruzada, além de garantir efetivamente a privacidade entre os usuários.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Estrutura Aprimorada de Junta de Vedação (Modelo de Utilidade CN 210317094 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920806869-a_improved_sealing_gasket_structure-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920806869-a_improved_sealing_gasket_structure-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estrutura de junta de vedação aprimorada. A seção vertical A é mais alta que a seção vertical B. A seção de conexão A compreende uma primeira seção inclinada, uma segunda seção inclinada e uma seção de conexão em arco. A seção de conexão em arco é conectada e disposta entre a primeira seção inclinada e a segunda seção inclinada. A primeira seção inclinada está conectada à seção vertical A e se estende além da seção vertical A. A segunda seção inclinada está conectada à seção vertical B e se estende além da seção vertical B. No uso prático, após o corpo da junta ser encaixado na ranhura reservada de uma moldura de porta limpa, a primeira e a segunda seções inclinadas fazem com que o corpo da junta se ajuste firmemente à ranhura reservada e vede a abertura da ranhura. Em conjunto com a seção de conexão em arco que se projeta para fora da ranhura reservada, quando a porta é fechada, ela entra em contato por interferência com a seção de conexão em arco, garantindo uma vedação adicional e resolvendo efetivamente a situação de formação de espaços para crescimento bacteriano ou acúmulo de poeira dentro da ranhura reservada.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Estrutura de Aro de Porta (Modelo de Utilidade CN 210564042 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920807158-a_door_frame_structure-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920807158-a_door_frame_structure-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estrutura de moldura de porta. Uma faixa vertical de moldura A e uma faixa vertical de moldura B compreendem cada uma uma chapa vertical em forma de U, uma chapa vertical perfilada e uma pluralidade de espaçadores A. A chapa vertical em forma de U e a chapa vertical perfilada são correspondentemente encaixadas entre si de modo a formar uma ranhura reservada. Os espaçadores A são correspondentemente dispostos em sequência em matriz ao longo da direção do comprimento da ranhura reservada, e a chapa vertical em forma de U, a chapa vertical perfilada e a pluralidade de espaçadores A formam uma ranhura de montagem. Uma faixa horizontal de moldura compreende uma chapa horizontal em forma de U, uma chapa horizontal perfilada e uma pluralidade de espaçadores B. A chapa horizontal em forma de U e a chapa horizontal perfilada são correspondentemente encaixadas entre si de modo a formar uma ranhura reservada, e os espaçadores B são correspondentemente dispostos em sequência em matriz ao longo da direção do comprimento da ranhura reservada. Uma superfície de um lado da chapa vertical perfilada, ao longo de sua direção de comprimento voltada para a chapa horizontal perfilada, é dotada de uma pluralidade de furos de inserção, e ambas as extremidades da chapa horizontal perfilada são dotadas de ganchos de inserção que cooperam com os furos de inserção. A estrutura de conexão das faixas da moldura é ajustada para facilitar a montagem e a desmontagem, economizando assim tempo de ajuste.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Estrutura de Janela de Observação (Modelo de Utilidade CN 210564146 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920807159-a_observation_window_structure-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920807159-a_observation_window_structure-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estrutura de janela de observação. Uma janela de observação é composta por uma estrutura de fixação, um corpo de vidro A e um corpo de vidro B. A estrutura de fixação é composta por um corpo de barra vertical A, um corpo de barra vertical B, um corpo de barra horizontal A e um corpo de barra horizontal B. O corpo de barra vertical A, o corpo de barra vertical B, o corpo de barra horizontal A e o corpo de barra horizontal B são cada um formados por um primeiro corpo de chapa em forma de U e um segundo corpo de chapa em forma de U. O segundo corpo de chapa em forma de U está fixado centralmente no primeiro corpo de chapa em forma de U. A largura do primeiro corpo de chapa em forma de U é superior à largura do segundo corpo de chapa em forma de U, de modo a formar posições em degrau nos dois lados do segundo corpo de chapa em forma de U. Uma posição rebaixada está disposta numa superfície lateral de cada um do corpo de vidro A e do corpo de vidro B. As posições em degrau no mesmo lado do corpo de barra vertical A, do corpo de barra vertical B, do corpo de barra horizontal A e do corpo de barra horizontal B delimitam um espaço de alojamento do vidro. Os lados do corpo de vidro A e do corpo de vidro B que possuem as posições rebaixadas estão dispostos correspondentemente nos respetivos espaços de alojamento do vidro. Através da disposição da estrutura de fixação e da cooperação com o ajuste da estrutura dos corpos de vidro, o desempenho de vedação da janela de observação é melhorado.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma estrutura de janela de observação com borda aparada (Modelo de Utilidade CN 210317039 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920808599-a_edge-trimmed_observation_window_structure-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920808599-a_edge-trimmed_observation_window_structure-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estrutura de janela de observação com acabamento de bordas. O lado da superfície inclinada de uma faixa de acabamento A encosta no lado da superfície vertical de uma faixa de acabamento D; o lado da superfície inclinada de uma faixa de acabamento B encosta no lado da superfície vertical da faixa de acabamento A; o lado da superfície inclinada de uma faixa de acabamento C encosta no lado da superfície vertical da faixa de acabamento B; e o lado da superfície inclinada da faixa de acabamento D encosta no lado da superfície vertical da faixa de acabamento C. Os lados das superfícies verticais da faixa de acabamento A, da faixa de acabamento B, da faixa de acabamento C e da faixa de acabamento D estendem-se todos até a posição do corpo de chapa em forma de U no lado adjacente. Quando é formada uma folga entre o lado da superfície vertical da faixa de acabamento A e o lado da superfície inclinada da faixa de acabamento B, como o comprimento da faixa de acabamento B é maior que o comprimento lateral do vidro, a faixa de acabamento B pode ser deslocada de modo que sua superfície inclinada permaneça encostada na faixa de acabamento A, enquanto o lado da superfície vertical da faixa de acabamento B é coberto pelo lado da superfície inclinada da faixa de acabamento C, garantindo assim que não apareça nenhuma folga. Por analogia, com essa disposição estrutural, reduz-se a exigência de precisão de usinagem das faixas de acabamento e também se aumenta a eficiência da produção.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Estrutura de Membrana de Fluxo Uniforme para Teto de Insuflamento de Ar (Modelo de Utilidade CN 210141630 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920993182-a_uniform-flow_membrane_structure_for_supply_air_ceiling-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920993182-a_uniform-flow_membrane_structure_for_supply_air_ceiling-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estrutura de membrana de fluxo uniforme para teto de insuflamento de ar, compreendendo uma armação de montagem e uma membrana de fluxo uniforme, em que a armação de montagem compreende uma moldura retangular e uma moldura circundante; estruturas de aperto são dispostas fixamente nas posições de canto da moldura retangular adjacentes à moldura circundante, e a membrana de fluxo uniforme é coberta e disposta entre a moldura retangular e as estruturas de aperto; cada estrutura de aperto compreende um parafuso, uma tira de mola vertical e uma tira de mola horizontal, uma extremidade da tira de mola vertical é disposta abaixo da tira de mola horizontal, e o parafuso penetra sucessivamente a tira de mola horizontal e a tira de mola vertical para ser fixado à moldura retangular; uma extremidade livre da tira de mola vertical está em contato de pressão com a membrana de fluxo uniforme, e uma extremidade livre da tira de mola horizontal está em contato de pressão com a membrana de fluxo uniforme; placas salientes de suspensão perpendiculares à moldura circundante são dispostas em dois lados opostos da moldura circundante. A armação de montagem é configurada para cooperar com a membrana de fluxo uniforme, e a membrana de fluxo uniforme é fixada por aperto pela armação de montagem, proporcionando instalação e desmontagem convenientes.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Estrutura de Moldura de Porta Tipo Split (Modelo de Utilidade CN 210317008 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920806921-a_split-type_door_frame_structure-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920806921-a_split-type_door_frame_structure-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estrutura de moldura de porta de tipo separado, compreendendo uma estrutura de barra vertical A, uma estrutura de barra horizontal e uma estrutura de barra vertical B. A estrutura de barra vertical A, a estrutura de barra horizontal e a estrutura de barra vertical B são cada uma formada pela combinação de uma barra principal e uma barra auxiliar. A barra principal compreende uma porção de montagem da barra auxiliar e uma seção de extensão. A seção de extensão é disposta em um lado da porção de montagem da barra auxiliar. A porção de montagem da barra auxiliar é formada com um corpo de ranhura reservado para inserção da barra auxiliar, e a seção de extensão e a porção de montagem da barra auxiliar formam um canto de montagem compatível com o canto de uma parede. Posições de gancho A são dispostas em dois lados opostos da abertura da porção de montagem da barra auxiliar. A barra auxiliar compreende uma seção de fechamento e uma porção em forma de U, e a seção de fechamento e a porção em forma de U formam uma estrutura com seção transversal em forma de b. Um gancho saliente é disposto em uma extremidade da seção de fechamento afastada da porção em forma de U, e uma dobra do gancho saliente é formada com uma ranhura A que coopera com a posição de gancho A. Um lado da porção em forma de U afastado da seção de fechamento é definido com uma ranhura B que coopera com a posição de gancho A. A estrutura de tipo separado é conveniente para montar, economiza o tempo de alinhamento durante a montagem, reduz o esforço físico dos trabalhadores de montagem e melhora a eficiência do trabalho.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma estrutura de porta vedada para sala limpa (Modelo de Utilidade CN 210317061 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920827630-a_sealed_cleanroom_door_structure-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920827630-a_sealed_cleanroom_door_structure-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma estrutura de porta selada para sala limpa, compreendendo um painel interno da porta e um painel externo da porta que são conectados de forma fixa. As superfícies dos painéis interno e externo da porta são opostas e estão em contato próximo para formar uma superfície de junção, e a linha que conecta o centro do painel interno da porta e o centro do painel externo da porta é perpendicular à superfície de junção. O comprimento e a largura do painel interno da porta são a e b, respectivamente, e o comprimento e a largura do painel externo da porta são A e B, respectivamente, onde a &amp;lt; A e b &amp;lt; B. Uma abertura de janela interna é disposta no painel interno da porta, e uma abertura de janela externa é disposta no painel externo da porta. A linha que conecta os centros da abertura de janela interna e da abertura de janela externa define um eixo de abertura de janela, e o eixo de abertura de janela é perpendicular à superfície de junção. O comprimento e a largura da abertura de janela interna são h e i, respectivamente, e o comprimento e a largura da abertura de janela externa são H e I, respectivamente, onde h &amp;gt; H e i &amp;gt; I. O presente modelo de utilidade pode garantir que uma estrutura de junta dobrada não linear seja formada entre o corpo da porta e a moldura da porta, e apresenta bom desempenho de vedação. Uma estrutura de abertura de janela na qual uma placa de vidro pode ser embutida é disposta no corpo da porta, para que o corpo da porta tenha função de observação. Além disso, a parede interna da estrutura de abertura de janela é escalonada, o que pode efetivamente impedir a passagem de contaminantes.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Mesa de Escrita Médica (Modelo de Utilidade CN 210768321 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920992505-a_medical_writing_desk-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920992505-a_medical_writing_desk-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma escrivaninha médica, compreendendo um corpo de gabinete e uma porta de gabinete. Uma fonte de luz é disposta na extremidade superior interna do corpo de gabinete, e um conjunto de acionamento e um conjunto conduzido são dispostos respectivamente em dois lados internos do corpo de gabinete. O conjunto de acionamento compreende um motor de engrenagens, uma haste de acionamento e uma primeira biela, e a extremidade inferior da primeira biela é conectada à porta de gabinete. O conjunto conduzido compreende um rolamento, uma haste oscilante e uma segunda biela, e a extremidade inferior da segunda biela é conectada à porta de gabinete. Um interruptor de motor eletricamente conectado ao motor de engrenagens é disposto no lado esquerdo da extremidade frontal do corpo de gabinete, um interruptor de fonte de luz eletricamente conectado à fonte de luz é disposto no lado superior da extremidade frontal do corpo de gabinete, e um sensor infravermelho também é disposto no lado superior da extremidade frontal do corpo de gabinete. Na escrivaninha médica do presente modelo de utilidade, a porta de gabinete é acionada pelo motor de engrenagens, realizando abertura e fechamento inteligentes.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma pia médica multifuncional para lavagem das mãos (Modelo de Utilidade CN 210767049 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201921360336-a_multifunctional_medical_hand-washing_basin-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201921360336-a_multifunctional_medical_hand-washing_basin-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma pia médica multifuncional para lavagem de mãos, compreendendo um corpo da pia de lavagem de mãos, sendo fornecido um tanque de lavagem no interior do corpo da pia, uma moldura de espelho fixada no corpo da pia, n torneiras com sensor fornecidas em um lado da moldura do espelho, sendo n um número inteiro maior que 1, e uma caixa elétrica de controle também fornecida no interior do corpo da pia; um espelho é fixado em um lado da moldura do espelho adjacente às torneiras com sensor, o espelho compreende uma placa de vidro, um lado da placa de vidro afastado das torneiras com sensor é coberto por uma camada refletiva, um lado da camada refletiva afastado da placa de vidro é fornecido com uma pluralidade de películas antiembaçantes uniformemente distribuídas, a camada refletiva é fornecida com um entalhe translúcido para display, um entalhe translúcido para controle por toque e um entalhe translúcido para primeira barra de luz, sendo fornecido um módulo de display no entalhe translúcido para display, um interruptor por toque no entalhe translúcido para controle por toque, e uma primeira barra de luz emissora no entalhe translúcido para primeira barra de luz. O presente modelo de utilidade pode fornecer ao usuário um efeito de iluminação de emissão frontal sem ângulos mortos, também pode fornecer ao usuário um efeito de exibição de diversos dados, e pode controlar o funcionamento das películas antiembaçantes conforme necessário.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Saída de Ar de Alimentação de Fácil Montagem e Desmontagem (Modelo de Utilidade CN 208382489 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201821017757-a_easy-to-assemble-and-disassemble_air_supply_outlet-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201821017757-a_easy-to-assemble-and-disassemble_air_supply_outlet-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma saída de ar de insuflamento fácil de montar e desmontar, compreendendo um corpo de caixa cilíndrico, um filtro e uma válvula reguladora. O corpo de caixa cilíndrico compreende uma cavidade interna; uma armação de suporte do filtro compatível com a cavidade interna é disposta na mesma e ligada de forma deslizante a uma parede lateral da cavidade interna. Um encaixe com formato compatível com o do filtro é aberto através da armação de suporte do filtro e se comunica com a cavidade interna, sendo o filtro ligado fixamente ao encaixe. Um motor é fixado na parte superior da cavidade interna e conectado à armação de suporte do filtro por meio de acionamento a fuso roscado. Uma placa difusora é articulada na parte inferior do corpo de caixa cilíndrico por meio de uma mola de torção, e uma pluralidade de dutos de descarga de ar é aberta através da placa difusora. Quando for necessária a manutenção ou substituição do filtro, abre-se a placa difusora e o motor aciona a armação de suporte do filtro para se deslocar para baixo; a armação desliza para baixo ao longo da parede lateral da cavidade interna até a posição de altura necessária, e então o filtro é removido do encaixe para manutenção ou substituição. A estrutura é simples e a operação é simples e prática, podendo aumentar a praticidade de montagem e desmontagem do filtro, bem como a eficiência de substituição ou manutenção do mesmo.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Saída de Fornecimento de Ar com Direção de Ar Variável (Modelo de Utilidade CN 208504675 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201821017866-a_variable_air-direction_air_supply_outlet-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201821017866-a_variable_air-direction_air_supply_outlet-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma tomada de ar de direção variável, compreendendo um corpo de caixa e uma válvula reguladora, sendo a válvula reguladora conectada de forma fixa na entrada de ar do corpo de caixa. O corpo de caixa compreende uma cavidade interna; uma saída de ar em comunicação com a cavidade interna é definida através da parte inferior do corpo de caixa, e um filtro é conectado de forma fixa na cavidade interna, na saída de ar. Uma carcaça de difusor em formato de arco é disposta abaixo do corpo de caixa, compreendendo a carcaça de difusor em arco uma cavidade de coleta de ar e uma placa difusora em arco localizada em um lado da cavidade de coleta de ar. Uma abertura de coleta de ar em comunicação com a cavidade de coleta de ar é definida através da parte superior da carcaça de difusor em arco, e o formato da abertura de coleta de ar corresponde ao formato da parte inferior do corpo de caixa; a parte inferior do corpo de caixa é disposta sobre a abertura de coleta de ar. Uma orelha A e uma orelha B são respectivamente dispostas em dois lados opostos da carcaça de difusor em arco; a orelha A é conectada de forma rotativa a uma parede lateral do corpo de caixa; um motor é conectado de forma fixa a um lado da cavidade interna, e um eixo de saída do motor é conectado de forma fixa à orelha B. Uma pluralidade de furos de exaustão de ar são atravessados a intervalos iguais na placa difusora em arco. A estrutura é simples e conveniente de usar; a área de descarga de ar pode ser aumentada, a direção de descarga de ar pode ser alterada automaticamente e a eficiência de renovação de ar é aprimorada.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Unidade Aperfeiçoada de Tratamento de Ar de Fumaça e Poeira (Modelo de Utilidade CN 208493568 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201821017789-a_improved_smoke-and-dust_air_treatment_unit-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201821017789-a_improved_smoke-and-dust_air_treatment_unit-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade se enquadra no campo técnico do tratamento de purificação de ar, referindo-se em particular a uma unidade melhorada de tratamento de ar para fumaça e poeira. O corpo da caixa é dividido em um primeiro espaço de filtragem, um segundo espaço de filtragem e um terceiro espaço de filtragem; o primeiro espaço de filtragem filtra parte da poeira de volume relativamente grande. Sob a condição de que um ventilador de tiragem induzida promova o fluxo de ar, o ar, após a poeira relativamente grande ser filtrada, passa por múltiplas camadas de placas filtrantes e entra no segundo espaço de filtragem; o segundo espaço de filtragem filtra principalmente bactérias no ar por meio da irradiação da luz solar; o ar após a conclusão da filtragem entra no terceiro espaço de filtragem para filtragem ultravioleta, e o ar filtrado é então descarregado por uma saída de ar sob a ação de um ventilador exaustor. Por meio da estrutura de filtragem de três camadas, obtém-se assim um bom efeito de filtragem de ar com fumaça e poeira.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Uma Unidade de Purificação de Ar (Modelo de Utilidade CN 208493688 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201821017933-a_air_purification_unit-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201821017933-a_air_purification_unit-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma unidade de purificação de ar, compreendendo um dispositivo de purificação, em que o dispositivo de purificação compreende uma carcaça e uma tampa superior; um primeiro tambor filtrante está disposto no dispositivo de purificação; um fio catódico está fixado no meio do primeiro tambor filtrante; um segundo tambor filtrante está encaixado externamente ao primeiro tambor filtrante; uma malha de náilon está encaixada externamente ao segundo tambor filtrante; uma placa anódica está encaixada externamente à malha de náilon; um ventilador pequeno está disposto na parte inferior do primeiro tambor filtrante; uma pluralidade de furos de saída de ar está formada na superfície lateral inferior da carcaça; e um elemento filtrante plissado está disposto na superfície lateral interna da carcaça. A unidade de purificação de ar do presente modelo de utilidade possui alta eficiência de trabalho e um bom efeito de limpeza do ar.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Unidade de Purificação de Ar (Modelo de Utilidade CN 210141666 U)</title>
				<link>https://pengchi.net/pt/docs/downloads/patents/cn201920993159-a_air_purification_unit-utility_model/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/downloads/patents/cn201920993159-a_air_purification_unit-utility_model/</guid>
				<description>&lt;h2 id=&#34;resumo&#34;&gt;Resumo&lt;/h2&gt;&#xA;&lt;p&gt;O presente modelo de utilidade fornece uma unidade de purificação de ar, que compreende um gabinete. No interior do gabinete é disponibilizada uma zona de remoção de pó; na parte inferior da zona de remoção de pó são disponibilizadas uma zona de coleta de pó e uma zona de instalação de fonte de luz; na parte inferior da zona de coleta de pó e da zona de instalação de fonte de luz é disponibilizada uma zona de equipamentos. O gabinete dispõe de uma persiana e de uma saída de ar, as quais se localizam respectivamente em dois lados da zona de remoção de pó. Na zona de remoção de pó são dispostos sequencialmente uma barreira de pó em favo de mel, uma placa de impulso com múltiplos ejetores, um grupo de remoção de pó de mangas e um ventilador; no topo da zona de remoção de pó é disponibilizado um conjunto de acionamento, cuja extremidade de saída está ligada à extremidade superior da placa de impulso com múltiplos ejetores. Na zona de coleta de pó é disponibilizado um armário de coleta de pó do tipo gaveta, localizado na parte inferior da barreira de pó em favo de mel. Na zona de instalação de fonte de luz é disponibilizada uma lâmpada ultravioleta, e na parte superior da lâmpada ultravioleta é colocada uma placa de vidro transparente à luz. A unidade de purificação de ar do presente modelo de utilidade apresenta elevada eficiência de remoção de pó.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Ambiente Arquitetônico</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/architecture/architectural-environment/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/architecture/architectural-environment/</guid>
				<description>&lt;h2 id=&#34;511-ambiente-cirúrgico&#34;&gt;5.1.1 Ambiente Cirúrgico&lt;/h2&gt;&#xA;&lt;p&gt;O departamento cirúrgico limpo deve bloquear a interferência de todas as vias de contaminação de forma abrangente e ao longo de todo o processo; portanto, a qualidade ambiental que pode afetar a qualidade do ar do departamento cirúrgico também constitui um risco potencial. Por isso, o local do departamento cirúrgico limpo deve ser preferencialmente escolhido em uma área com qualidade ambiental natural relativamente boa, baixas concentrações de poeira atmosférica e bactérias, e sem gases nocivos; essa é a maneira ideal de garantir a limpeza do ar, ao mesmo tempo que economiza ao máximo energia e reduz os custos de investimento e operação.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 1. Introdução a Portas Hospitalares</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/fundamentals-of-medical-and-cleanroom-doors/introduction-to-medical-doors/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/fundamentals-of-medical-and-cleanroom-doors/introduction-to-medical-doors/</guid>
				<description>&lt;p&gt;Um bloco operatório perde pressão positiva sempre que a sua porta se abre, uma porta de corredor numa enfermaria é atingida por camas e carrinhos centenas de vezes por semana, e a porta de uma sala de raios X deve bloquear a radiação tão eficazmente como a parede que a envolve. Como pode um único componente de construção satisfazer todas estas exigências em simultâneo? A resposta curta é que não pode — e é por isso que &amp;ldquo;porta hospitalar&amp;rdquo; designa uma família de produtos de engenharia, e não um produto único.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 12. Materiais de Aço para Portas Médicas e de Salas Limpas</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/materials-core-structures-and-surface-finishes/steel-materials/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/materials-core-structures-and-surface-finishes/steel-materials/</guid>
				<description>&lt;p&gt;Um especificador pergunta: &amp;ldquo;O aço inoxidável é sempre a escolha certa para uma porta hospitalar?&amp;rdquo; A resposta honesta é não. Aço inoxidável grau 316 em um corredor administrativo seco é dinheiro gasto sem nenhum ganho de desempenho, enquanto o aço laminado a frio com um sistema de revestimento deficiente em uma área úmida de esterilização apresentará sangramento de ferrugem em dois anos. A seleção de materiais é uma questão de adequar o ambiente ao substrato — não de comprar a opção mais cara.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 16. Design de Portas Hospitalares e Fluxo de Trabalho de Engenharia</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/manufacturing-processes-and-quality-assurance/medical-door-design-engineering-workflow/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/manufacturing-processes-and-quality-assurance/medical-door-design-engineering-workflow/</guid>
				<description>&lt;p&gt;Uma porta hospitalar que chega ao local com o visor 40 mm fora do centro, ou com a folga errada para uma vedação montada no piso, não é um problema de qualidade na fábrica — é um problema de engenharia que começou semanas antes na prancheta. Como um projeto de porta hospitalar deve realmente avançar de um pedido de compra para um programa de fabricação pronto para corte?&lt;/p&gt;&#xA;&lt;h2 id=&#34;do-recebimento-do-pedido-aos-desenhos-de-engenharia&#34;&gt;Do Recebimento do Pedido aos Desenhos de Engenharia&lt;/h2&gt;&#xA;&lt;p&gt;O fluxo de trabalho começa com a confirmação dimensional. Para portas personalizadas, o comprador ou a equipe de medição do fabricante registra a abertura estrutural livre, a espessura da parede, a diferença de nível do piso e quaisquer obstruções (dutos, eletrocalhas, tubulações de gases medicinais) que afetem a fixação do batente. O engenheiro então produz três níveis de documentos:&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 20. Portas Médicas Manuais de Aço</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/manual-steel-medical-doors/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/manual-steel-medical-doors/</guid>
				<description>&lt;p&gt;Nem todas as portas de hospital precisam de um motor. Na verdade, a maioria das portas numa unidade de saúde — quartos de enfermaria, armazéns, escritórios, muitos corredores — são manuais, e escolher a configuração errada ou a classe de ferragens inadequada é um dos erros de especificação mais comuns. Como deve adequar uma porta de aço hospitalar manual ao respetivo espaço?&lt;/p&gt;&#xA;&lt;h2 id=&#34;folha-única-vs-folha-dupla&#34;&gt;Folha Única vs. Folha Dupla&lt;/h2&gt;&#xA;&lt;ul&gt;&#xA;&lt;li&gt;&lt;strong&gt;Portas de folha única&lt;/strong&gt; servem compartimentos: quartos de pacientes, escritórios, espaços de serviço. Larguras de vão livre de 900–1000 mm são adequadas para camas e cadeiras de rodas; folhas mais estreitas são aceitáveis apenas para armários e colunas técnicas.&lt;/li&gt;&#xA;&lt;li&gt;&lt;strong&gt;Portas de folha dupla&lt;/strong&gt; (par) servem corredores e rotas de equipamento onde é necessário o vão total para camas, carrinhos e equipamento de imagiologia. A prática em conjuntos de porta para unidades de saúde consiste em fornecer portas de corredor como conjuntos de batente simples ou duplo com classificação FD30/FD60, consoante o plano de compartimentação. As portas de folha dupla necessitam de um &lt;strong&gt;seletor de sequência de fecho&lt;/strong&gt; em pares com galce, para que a folha inativa feche primeiro — caso contrário, a folha de fecho ressalta no galce e a porta nunca veda.&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;&lt;p&gt;Compromisso: uma porta dupla oferece um grande vão, mas duplica as ferragens, a coordenação de fecho e os pontos de falha de vedação. Se o tráfego raramente necessitar da largura total, uma porta de &lt;strong&gt;folha e meia&lt;/strong&gt; (par desigual) é frequentemente a melhor resposta — o tráfego diário utiliza a folha grande; a folha pequena abre apenas para a movimentação de equipamento.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 26. Como Selecionar a Porta Médica Certa</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/product-selection-and-system-configuration/how-to-select-the-right-medical-door/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/product-selection-and-system-configuration/how-to-select-the-right-medical-door/</guid>
				<description>&lt;p&gt;Um distribuidor na região do Golfo encomendou uma vez quarenta &amp;ldquo;portas hospitalares, em aço inoxidável, resistentes ao fogo&amp;rdquo; para uma nova clínica — apenas para descobrir no local que os blocos operatórios precisavam de portas de correr com vedação hermética, as salas de raios-X precisavam de revestimento de chumbo, e as portas das enfermarias não precisavam de nenhuma dessas características, mas sim de proteção contra impactos. A falha de especificação não foi uma questão de qualidade; foi uma questão de ignorar um quadro de seleção. As portas hospitalares são compradas com base em critérios errados com mais frequência do que quase qualquer outro produto de construção, porque &amp;ldquo;porta hospitalar&amp;rdquo; abrange pelo menos seis produtos funcionalmente diferentes.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 30. Normas Europeias para Portas Médicas e de Salas Limpas</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/european-and-us-standards-compliance-and-testing/european-standards-medical-cleanroom-doors/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/european-and-us-standards-compliance-and-testing/european-standards-medical-cleanroom-doors/</guid>
				<description>&lt;p&gt;Um comprador pergunta a um fornecedor: &amp;ldquo;As suas portas têm certificação EN?&amp;rdquo; O fornecedor diz que sim. Seis meses depois, o inspetor de incêndio pede o relatório de classificação — e o &amp;ldquo;certificado&amp;rdquo; revela-se ser um ensaio realizado pela própria fábrica numa única amostra, sem qualquer relação com uma norma harmonizada. Não existe uma &amp;ldquo;certificação EN&amp;rdquo; genérica para portas. Cada norma abrange um âmbito definido, produz evidências definidas e deixa de se aplicar em limites definidos. Este capítulo mapeia as quatro normas que os compradores encontram com mais frequência, acrescentando a ISO 14644 para salas limpas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 33. Preparação do Local e Instalação da Porta</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/installation-commissioning-and-maintenance/site-preparation-and-door-installation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/installation-commissioning-and-maintenance/site-preparation-and-door-installation/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; As portas chegam ao local — corretamente fabricadas, testadas e etiquetadas — e seis meses depois metade delas emperra, apresenta vazamento de ar ou não trava. Na maioria das análises post-mortem, a causa raiz não é o produto, mas sim o vão: paredes fora de tolerância, falta de alimentação elétrica, nível de piso incorreto ou uma esquadria chumbada antes de estar a prumo. A qualidade da instalação determina se o desempenho de fábrica sobrevive ao contato com o edifício.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 36. Especificações e Aquisição de Portas Médicas</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/export-procurement-and-manufacturing-cooperation/medical-door-specifications-and-procurement/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/export-procurement-and-manufacturing-cooperation/medical-door-specifications-and-procurement/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Um distribuidor na região do Golfo recebe uma licitação para 400 portas hospitalares. A especificação diz apenas &amp;ldquo;porta de aço, 1,0 mm, resistente ao fogo&amp;rdquo;. No meio da produção, o consultor rejeita a submissão porque as portas não possuem um fechador certificado, o perfil do batente não corresponde à composição da parede, e &amp;ldquo;1,0 mm&amp;rdquo; acabou significando espessura da chapa para o comprador, mas construção total da folha para a fábrica. Seis meses e uma reclamação depois, todos concordam que o problema começou com a especificação, não com o aço.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 39. Salas Cirúrgicas e Salas Cirúrgicas Modulares</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/operating-rooms-modular-operating-rooms/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/operating-rooms-modular-operating-rooms/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Um hospital substitui duas salas de cirurgia por blocos operatórios modulares. O sistema de paredes chega pré-projetado; as portas são encomendadas separadamente &amp;ldquo;a combinar&amp;rdquo;. No local, a calha da porta de correr hermética não se encaixa no módulo estrutural da parede modular, o vão livre fica 80 mm aquém da largura do aparelho de anestesia e a sala não consegue manter a pressão positiva porque a vedação da porta tem fugas ao nível do pavimento. Nenhum destes problemas é um defeito da porta — são falhas de integração.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 4. Projeto do Caixilho da Porta e Configuração Estrutural</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/door-frame-design-and-structural-configuration/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/door-frame-design-and-structural-configuration/</guid>
				<description>&lt;p&gt;Uma folha de aço de 90 kg, batendo ao fechar várias centenas de vezes por dia sob a ação de um fechador pesado, está inteiramente suspensa pelo seu caixilho. Quando uma porta hospitalar começa a travar, a ceder ou a afastar-se da parede, a culpa recai normalmente sobre a folha — mas a causa raiz é, com maior frequência, um caixilho que era demasiado leve, ancorado no substrato errado ou instalado numa parede para a qual nunca foi projetado.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Composição do Departamento de Operações Limpas</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/composition-clean-operating-department/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/composition-clean-operating-department/</guid>
				<description>&lt;h2 id=&#34;311-departamento-cirúrgico&#34;&gt;3.1.1 Departamento Cirúrgico&lt;/h2&gt;&#xA;&lt;p&gt;O departamento cirúrgico é composto por várias salas de operação, juntamente com uma área auxiliar formada por ambientes que atendem às salas de cirurgia; os espaços da área auxiliar podem ser divididos ainda entre aqueles que atendem direta ou indiretamente às salas de operação. As salas funcionais de atendimento direto, como sala de armazenamento de curativos estéreis, sala de anestesia, sala de escovação cirúrgica, sala de armazenamento de instrumentos (desinfectados), sala de preparação e posto de enfermagem, são sem dúvida indispensáveis; também são necessários os ambientes de atendimento indireto, como escritórios, salas de conferência, salas de observação para ensino e salas de plantão. De acordo com os requisitos gerais do hospital, as salas funcionais que atendem diretamente às salas de operação podem ser equipadas com sistemas de ar-condicionado limpo e funcionar como salas auxiliares limpas, devendo estar localizadas dentro da área limpa.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Conceitos de Gestão de Centro Cirúrgico</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/concepts-operating-room-management/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/concepts-operating-room-management/</guid>
				<description>&lt;p&gt;A sala de cirurgia é um dos importantes departamentos técnicos de um hospital e o maior espaço aberto para tratamento centralizado. Com o rápido avanço da medicina clínica, as operações cirúrgicas estão se desenvolvendo no sentido de maior precisão e sofisticação, o que exige salas de cirurgia cada vez mais especializadas e modernas para acompanhar essa evolução.&lt;/p&gt;&#xA;&lt;h2 id=&#34;1311-filosofia-de-trabalho-da-sala-de-cirurgia&#34;&gt;13.1.1 Filosofia de Trabalho da Sala de Cirurgia&lt;/h2&gt;&#xA;&lt;p&gt;Refere-se às crenças da equipe da sala de cirurgia, que determinam como a equipe cumpre seu propósito.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Construção</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/construction-acceptance/construction/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/construction-acceptance/construction/</guid>
				<description>&lt;p&gt;(1) A construção do departamento cirúrgico limpo deve ser realizada após a conclusão das obras de engenharia civil e a limpeza do canteiro.&lt;/p&gt;&#xA;&lt;p&gt;(2) A construção das salas de cirurgia limpa deve seguir uma sequência definida de procedimentos; devem ser evitadas operações geradoras de poeira durante a instalação dos sistemas, sendo obrigatória a prevenção a essas atividades na instalação de filtros HEPA ou de terminais de insuflamento de ar.&lt;/p&gt;&#xA;&lt;p&gt;(3) O procedimento de construção das salas de cirurgia limpa está apresentado na Figura 12.1 (demais salas auxiliares podem adotar este procedimento como referência).&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Centro Cirúrgico Limpo do Edifício Médico, Hospital Geral do Exército de Libertação Popular da China</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/chinese-pla-general-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/chinese-pla-general-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O Hospital Geral do Exército de Libertação Popular (EPL) da China, conhecido comumente como Hospital 301, é um grande hospital geral e o maior hospital de Classe III, Grau A de todo o sistema militar.&lt;/p&gt;&#xA;&lt;p&gt;(1) O edifício médico é um empreendimento de construção nova dentro do complexo do Hospital 301, um projeto de relevância nacional cuja pedra fundamental foi lançada pessoalmente por líderes da Comissão Militar Central no outono de 1991. Possui área construída total de 56 000 m², sendo 2 andares subterrâneos e 14 andares acima do solo, totalizando 16 pavimentos. Estruturalmente, o edifício é dividido nas Seções Ⅰ, Ⅱ, Ⅲ e Ⅳ, com obras planejadas em duas fases. A primeira fase compreendeu a construção das Seções Ⅰ, Ⅱ e Ⅲ, correspondentes à estrutura principal do subsolo ao 14º andar, com aproximadamente 50 000 m²; a obra foi concluída e colocada em uso em outubro de 1994. A segunda fase compreendeu a construção da Seção Ⅳ, do 1º ao 4º andar acima do solo, com início em 1995 e aproximadamente 6 000 m², tendo sido concluída e entregue para uso no mesmo ano.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Influência dos Indicadores Técnicos na Qualidade Cirúrgica</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/technical-indicators-surgical-quality/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/technical-indicators-surgical-quality/</guid>
				<description>&lt;p&gt;Em um departamento cirúrgico limpo, os diversos tipos de salas limpas são classificados conforme a concentração bacteriana, sendo a classe de limpeza do ar a condição de garantia necessária. A concentração bacteriana de cada zona da sala cirúrgica é ainda regulamentada por zona e por grau, com uma contagem bacteriana máxima permitida especificada. Essas discussões estão detalhadas no Capítulo 3, &amp;ldquo;Composição e Graus do Departamento Cirúrgico Limpo&amp;rdquo;. O que este capítulo se propõe a elaborar é que todos os padrões técnicos dos diferentes tipos de salas limpas no departamento cirúrgico limpo devem se basear na premissa de que, após o sistema (ou equipamento) de ar condicionado de purificação entrar em operação e atingir o tempo de autolimpeza especificado, as concentrações médias de bactérias aerotransportadas ou bactérias sedimentáveis e a classe de limpeza do ar (incluindo os dois tamanhos de partículas $\geqslant 0.5\mu m$ e $5\mu m$) atingidas em estado vazio ou estático cumprem integralmente os requisitos listados no Capítulo 3. Após atender aos requisitos do grau correspondente, os demais indicadores técnicos relevantes também devem obedecer aos valores ou intervalos especificados na Tabela 4.1 do Código. Os 9 indicadores incluídos na Tabela 4.1 parecem ser independentes entre si, mas na verdade vários dos principais indicadores estão inter-relacionados e exercem influência mútua; por exemplo, o indicador de valor de pressão estática também é um indicador importante para prevenir infecções cruzadas, atender ao requisito de manutenção da qualidade do ar do ambiente interno do departamento cirúrgico e garantir a prevenção de interferências no departamento cirúrgico provenientes de outros departamentos através do ar.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Instalações de Abastecimento de Água</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/water-supply-drainage/water-supply-facilities/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/water-supply-drainage/water-supply-facilities/</guid>
				<description>&lt;h2 id=&#34;911-requisitos-para-o-projeto-de-abastecimento-de-água&#34;&gt;9.1.1 Requisitos para o Projeto de Abastecimento de Água&lt;/h2&gt;&#xA;&lt;p&gt;(1) O sistema de abastecimento de água no departamento cirúrgico limpo deve possuir duas entradas de água, todas as tubulações devem ser embutidas, e devem ser adotadas medidas anticondensação.&lt;/p&gt;&#xA;&lt;p&gt;O requisito de que o sistema de abastecimento de água possua duas entradas significa que não é permitido o abastecimento intermitente de água, devendo ser adotado o abastecimento bidirecional. O abastecimento do departamento cirúrgico deve ser garantido por duas redes principais independentes, de forma que, quando uma falhar, a outra possa ser acionada imediatamente. Caso exista apenas uma tubulação de abastecimento, deve ser instalado um reservatório de água ou adicionada uma segunda fonte hídrica para garantir a segurança do abastecimento. O reservatório deve ser equipado com controle de nível de água e dispositivos de alarme de emergência. Quando a fonte hídrica for insuficiente ou a boia estiver danificada e o nível de água estiver baixo, um alarme deve ser acionado para alertar a equipe de gestão, garantindo que a demanda de água durante os procedimentos cirúrgicos seja atendida em tempo hábil.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Princípios do Controle de Infecções Nosocomiais</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/general-provisions/controlling-nosocomial-infections/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/general-provisions/controlling-nosocomial-infections/</guid>
				<description>&lt;p&gt;A construção de um departamento cirúrgico limpo deve atender simultaneamente aos requisitos das normas higiênicas e das normas técnicas de limpeza do ar em três aspectos: projeto, construção e aceitação.&lt;/p&gt;&#xA;&lt;h2 id=&#34;211-o-controle-de-infecções-hospitalares-deve-ser-um-conceito-de-controle-abrangente-interrompendo-todas-as-vias-de-contaminação&#34;&gt;2.1.1 O controle de infecções hospitalares deve ser um conceito de controle abrangente, interrompendo todas as vias de contaminação&lt;/h2&gt;&#xA;&lt;p&gt;Não basta que apenas a sala de cirurgia seja limpa; o requisito de limpeza deve ser implementado em toda uma área composta pela sala de cirurgia e suas salas auxiliares de apoio necessárias. Essa área é o departamento cirúrgico, ou seja, o departamento cirúrgico limpo.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Princípios e Ideias para a Formulação dos Padrões dos Departamentos de Centro Cirúrgico Limpo dos Hospitais da China</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/principles-china-clean-operating-department-standards/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/principles-china-clean-operating-department-standards/</guid>
				<description>&lt;p&gt;Desde o nascimento da primeira sala de cirurgia com tecnologia de limpeza de ar nos Estados Unidos, em janeiro de 1966, a oferta de salas de cirurgia limpas se tornou um importante símbolo da modernização hospitalar em diversos países. Com a elevação do padrão de vida da população na China e a demanda cada vez maior por saúde, aliada ao impulso da avaliação e classificação hospitalar, nos últimos 10 anos o número de salas de cirurgia limpas construídas em hospitais chineses por meio de reforma, expansão e construção nova chegou a mil unidades, envolvendo quase cem hospitais. Como existem 15.270 hospitais de nível condal ou superior em todo o país, sendo 7.498 hospitais com mais de 100 leitos e 788 hospitais com mais de 500 leitos, esse trabalho de transformação e renovação técnica continuará se desenvolvendo de forma ainda mais rápida. Por um lado, isso é uma boa notícia, mas por outro lado também é preocupante. O que preocupa é a qualidade. Pois, nos últimos anos, o mercado doméstico de construção de salas limpas tem estado bastante caótico — diferentemente do início dos anos 1960, quando as salas limpas eram consideradas algo muito misterioso e tratadas com grande cautela —, hoje qualquer um se atreve a construí-las, e parece que todos conseguem construí-las bem, como se elevá-las a qualquer classe não exigisse quase nenhum esforço. Onde está o segredo? Acontece que era utilizado um volume de ar várias vezes maior do que o exigido em condições dinâmicas, enquanto os resultados eram medidos no estado construído (vazio); em alguns casos, a medição era até mesmo realizada pelos próprios construtores, e os métodos não cumpriam os requisitos das normas. Mas um grande volume de ar suprido não serve de nada: em algumas salas de cirurgia de fluxo laminar, a velocidade do ar sobre a mesa cirúrgica é extremamente baixa; em outras, não só a sala de cirurgia está em pressão negativa em relação ao corredor limpo, como o corredor limpo também está em pressão negativa em relação ao exterior, e nenhum ajuste consegue corrigir o problema; em outras, o ruído é muito alto; em outras, o ar fresco é insuficiente em demasia, a ponto de, em um grande hospital, uma enfermeira de centro cirúrgico desmaiar durante o plantão; e, devido ao fluxo de ar deficiente e ao vazamento severo dos filtros, algumas salas de cirurgia cardíaca estão inutilizáveis desde o dia em que foram concluídas, com concentrações bacterianas ainda maiores do que antes da instalação de qualquer sistema de limpeza de ar, e os reparos repetidos não surtiram efeito. É claro que também existem aqueles que não entendem do assunto, ou que enganam deliberadamente, utilizando meios que não são de fluxo laminar de forma alguma e alegando tratar-se de fluxo laminar Classe 100 com base apenas em um único valor de contagem de partículas de poeira.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Requisitos das linhas de fornecimento e distribuição de energia</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/power-distribution/power-supply-distribution-lines/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/power-distribution/power-supply-distribution-lines/</guid>
				<description>&lt;h2 id=&#34;1111-comutação-entre-duas-fontes-de-alimentação&#34;&gt;11.1.1 Comutação entre Duas Fontes de Alimentação&lt;/h2&gt;&#xA;&lt;p&gt;(1) O fornecimento e a distribuição de energia do bloco operatório limpo devem constituir um sistema independente, alimentado diretamente pela estação central de distribuição de energia do edifício onde o bloco está instalado, sendo vedado compartilhar a mesma linha com qualquer outra área consumidora de energia.&lt;/p&gt;&#xA;&lt;p&gt;(2) A estação central de distribuição de energia do edifício que abriga o bloco operatório limpo deve ser alimentada por duas ou mais redes elétricas. Essas redes de fornecimento devem ser capazes de realizar comutação automática entre si: quando uma rede sofrer falha ou estiver em manutenção, o fornecimento pode ser comutado instantaneamente (tempo de comutação inferior a 0,5 s) para outra rede, mantendo o abastecimento normal de energia. Caso não haja duas redes elétricas disponíveis no local, outros meios podem ser utilizados para garantir o fornecimento de energia ao bloco operatório, como a adoção de um gerador de reserva. O gerador deve estar interligado ao centro de distribuição de energia para que, quando houver falha na rede principal, o sistema comute automaticamente para acionar o gerador, colocando-o em operação em tempo hábil para manter o funcionamento normal do bloco. Caso o gerador não consiga fornecer energia normalmente no prazo de 1 minuto, o sistema deve comutar automaticamente para a fonte de alimentação de emergência UPS (ou EPS) de reserva no prazo de 1 segundo, para garantir o abastecimento das salas cirúrgicas. Quando o gerador de reserva estiver fornecendo energia normalmente, a fonte de emergência UPS (ou EPS) comuta de volta para o gerador de reserva. Caso sejam utilizados EPS ou outros sistemas de baterias como fonte de reserva de emergência, devem ser previstas medidas de ventilação e de segurança contra incêndio. As Figuras 11.1 e 11.2 são diagramas esquemáticos da comutação da fonte de alimentação de reserva.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sistemas Hospitalares de Aquecimento, Ventilação e Ar Condicionado</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/air-conditioning-system/hospital-hvac-systems/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/air-conditioning-system/hospital-hvac-systems/</guid>
				<description>&lt;h2 id=&#34;711-objetivo-do-aquecimento-ventilação-e-ar-condicionado-hospitalar&#34;&gt;7.1.1 Objetivo do Aquecimento, Ventilação e Ar Condicionado Hospitalar&lt;/h2&gt;&#xA;&lt;p&gt;O objetivo do aquecimento, ventilação e ar condicionado hospitalar é criar um ambiente interno confortável e saudável, ao mesmo tempo que previne eficazmente as infeções adquiridas no hospital, mantém o ambiente médico e higiênico mais adequado exigido durante os processos médicos, implementa medidas de prevenção de desastres adequadas e garante a segurança, a eficácia e a confiabilidade dos equipamentos e sistemas de aquecimento, ventilação e ar condicionado. Além disso, devem ser adotadas medidas para prevenir a propagação da poluição e economizar energia, tendo como premissa a proteção do meio ambiente global.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Tamanho de Partícula</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/particle-size/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/particle-size/</guid>
				<description>&lt;p&gt;O tamanho de partícula geralmente se refere a uma determinada dimensão de comprimento que atravessa o interior de uma partícula, sem implicar qualquer forma geométrica regular.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;[Referência]&lt;/strong&gt; Os tamanhos de partícula podem ser divididos em duas grandes categorias.&lt;/p&gt;&#xA;&lt;p&gt;Uma categoria é medida e definida diretamente de acordo com as propriedades geométricas da partícula, como os tamanhos de partícula determinados por microscopia.&lt;/p&gt;&#xA;&lt;p&gt;A outra categoria é medida e definida indiretamente de acordo com uma determinada propriedade física da partícula, como os tamanhos de partícula determinados pelo método de sedimentação ou pelo método fotoelétrico; na verdade, esses correspondem a um tipo de diâmetro equivalente.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Tipos e Propriedades dos Gases Medicinais</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/medical-gases/types-properties-medical-gases/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/medical-gases/types-properties-medical-gases/</guid>
				<description>&lt;p&gt;Os gases medicinais no departamento cirúrgico limpo são instalações indispensáveis para auxiliar no tratamento e salvar a vida dos pacientes.&lt;/p&gt;&#xA;&lt;h2 id=&#34;811-gases-medicinais-no-departamento-cirúrgico&#34;&gt;8.1.1 Gases Medicinais no Departamento Cirúrgico&lt;/h2&gt;&#xA;&lt;p&gt;Existem diversos tipos, sendo os principais oxigênio, sucção por pressão negativa, ar comprimido, nitrogênio, óxido nitroso, gases mistos, etc., mas pelo menos três gases — oxigênio, ar para sucção por pressão negativa e ar comprimido — devem ser instalados na sala cirúrgica limpa.&lt;/p&gt;&#xA;&lt;p&gt;A quantidade de reserva da fonte de gases medicinais não deve ser inferior ao consumo de três dias.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Visão geral</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/overview/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/overview/</guid>
				<description>&lt;p&gt;O equipamento básico de uma sala cirúrgica corresponde às instalações básicas disponibilizadas para uma sala cirúrgica limpa, relacionadas à disposição da planta baixa e à instalação arquitetônica da sala, não incluindo instrumentos e equipamentos médicos especializados ou móveis. O equipamento básico é um equipamento auxiliar indispensável para a sala cirúrgica durante as cirurgias; cada item possui sua posição de instalação correspondente na sala, não podendo ser colocado arbitrariamente em qualquer local, de forma a evitar inconvenientes durante o uso. O equipamento básico corresponde aos itens e quantidades mínimos a serem fornecidos; com base nisso, determinados acessórios, como armários de armazenamento, armários de guarda e gavetas, podem ser adicionados de acordo com as necessidades de uso. Quando são organizados ou fabricados, eles costumam ser integrados a armários, caixas e elementos semelhantes para formar unidades combinadas superior e inferior, de forma a evitar que o ambiente fique com aparência desorganizada. O conteúdo do equipamento básico é apresentado na Tabela 6.1.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Visão geral</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/overview/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/overview/</guid>
				<description>&lt;p&gt;Os edifícios hospitalares são uma forma de edificação pública, e o bloco operatório limpo hospitalar é um componente funcional dentro de um edifício hospitalar. Existem diversas formas de construir as edificações de um bloco operatório limpo hospitalar: algumas são construídas em conjunto com outros edifícios funcionais do hospital, enquanto outras são construídas de forma independente, dependendo das condições e do porte do hospital. Quer sejam construídas conjuntamente ou de forma independente, e quer se trate de um edifício de um só pavimento, de múltiplos pavimentos ou de um edifício alto, o projeto de proteção contra incêndio da edificação — incluindo os compartimentos corta-fogo no interior da edificação, o limite de altura entre as classificações de edifício alto e de múltiplos pavimentos, a classe de resistência ao fogo da edificação e os correspondentes requisitos de limite de resistência ao fogo dos componentes construtivos — deve primeiramente cumprir os requisitos pertinentes das normas nacionais de projeto de proteção contra incêndio para edifícios civis em geral [como as normas nacionais &lt;em&gt;Código de Projeto de Proteção contra Incêndio em Edifícios&lt;/em&gt; (GBJ16-87) e &lt;em&gt;Código de Projeto de Proteção contra Incêndio em Edifícios Civis em Altura&lt;/em&gt; (GB50045-95)]. Como parte dos edifícios funcionais do hospital, deve também cumprir o disposto na norma nacional setorial &lt;em&gt;Código de Projeto de Hospital Geral&lt;/em&gt; (JGJ49-88). Portanto, além de cumprir as disposições deste guia, o projeto de proteção contra incêndio da edificação do bloco operatório limpo deve também cumprir o disposto em normas nacionais vigentes, como o &lt;em&gt;Código de Projeto de Proteção contra Incêndio em Edifícios&lt;/em&gt;, o &lt;em&gt;Código de Projeto de Proteção contra Incêndio em Edifícios Civis em Altura&lt;/em&gt; e o &lt;em&gt;Código de Projeto de Hospital Geral&lt;/em&gt;.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Aceitação do Projeto</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/construction-acceptance/project-acceptance/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/construction-acceptance/project-acceptance/</guid>
				<description>&lt;p&gt;O sistema de aceitação em duas etapas é implementado da seguinte forma:&#xA;Sistema de aceitação em duas etapas&#xA;├─ Aceitação de conclusão&#xA;│   ├─ Inspeção visual de documentos, desenhos e da edificação da planta — Confirmação dos requisitos de projeto&#xA;│   ├─ Inspeção visual do sistema ─────────────────┐&#xA;│   ├─ Operação experimental de unidades e sistemas individuais ──┼─ Qualificação de instalação&#xA;│   ├─ Teste de vazamento de filtro (concluído pelo contratado) ───┘&#xA;│   └─ Teste de ajuste (concluído pelo contratado) — Qualificação operacional&#xA;└─ Avaliação de desempenho abrangente — Inspeção de desempenho por uma terceira parte — Qualificação de desempenho&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 17. Montagem, Soldagem e Acabamento de Superfície</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/manufacturing-processes-and-quality-assurance/assembly-welding-surface-finishing/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/manufacturing-processes-and-quality-assurance/assembly-welding-surface-finishing/</guid>
				<description>&lt;p&gt;Uma chapa da folha cortada e dobrada ainda é apenas chapa metálica. A etapa que decide se uma porta hospitalar sobrevive a dez anos de limpezas com desinfetante e impactos de carrinhos — ou enferruja nas juntas em apenas dois — é a fabricação: soldagem, instalação do núcleo, montagem e revestimento. O que separa uma porta de grau hospitalar de uma porta de aço genérica neste ponto da linha?&lt;/p&gt;&#xA;&lt;h2 id=&#34;soldagem-e-fabricação-da-porta&#34;&gt;Soldagem e Fabricação da Porta&lt;/h2&gt;&#xA;&lt;p&gt;As chapas formadas, os perfis de borda e os reforços internos são unidos por &lt;strong&gt;soldagem TIG ou MIG&lt;/strong&gt;, com solda por pontos utilizada nas fixações internas não visíveis. Para portas hospitalares, os requisitos de soldagem diferem das portas comuns de duas formas:&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 2. Portas para Salas Limpas e Ambientes Controlados</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/fundamentals-of-medical-and-cleanroom-doors/cleanroom-doors-and-controlled-environments/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/fundamentals-of-medical-and-cleanroom-doors/cleanroom-doors-and-controlled-environments/</guid>
				<description>&lt;p&gt;Uma sala de envase farmacêutico passa no ensaio de contagem de partículas da ISO 14644 no dia do comissionamento e falha seis meses depois. O HVAC está inalterado; os filtros são novos. O culpado, eventualmente descoberto, é uma porta cuja vedação inferior já não comprime de forma uniforme — deixando escapar ar não controlado suficiente para quebrar a cascata de pressão da sala. As portas de salas limpas falham silenciosamente, e é por isso que merecem mais atenção de engenharia do que aquela que normalmente recebem.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 21. Portas Médicas de Correr Automáticas</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/automatic-sliding-medical-doors/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/automatic-sliding-medical-doors/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Uma porta de corredor de hospital precisa abrir mais de 500 vezes por dia, permitir a passagem de camas e carrinhos sem contato e, ainda assim, não ferir um paciente desorientado que caminhe em direção a uma folha em movimento. Como dimensionar e especificar o operador para que ele suporte esse ciclo de trabalho?&lt;/p&gt;&#xA;&lt;h2 id=&#34;configurações&#34;&gt;Configurações&lt;/h2&gt;&#xA;&lt;ul&gt;&#xA;&lt;li&gt;&lt;strong&gt;Deslizante simples&lt;/strong&gt; — uma folha, recolhe para um lado. Necessita de espaço de parede para recolhimento igual à largura da abertura livre. Comum em quartos de pacientes e entradas de UTI.&lt;/li&gt;&#xA;&lt;li&gt;&lt;strong&gt;Bipartida&lt;/strong&gt; — duas folhas abrem a partir do centro. Reduz pela metade a distância de percurso, portanto a abertura é mais rápida para uma determinada largura livre; a escolha padrão para corredores principais e entradas de centros cirúrgicos.&lt;/li&gt;&#xA;&lt;li&gt;&lt;strong&gt;Telescópica&lt;/strong&gt; — duas ou mais folhas se empilham em um lado, fornecendo aproximadamente 2/3 da abertura estrutural como largura livre onde o espaço de parede para recolhimento é limitado. Desvantagem: mais peças móveis, mais manutenção, custo mais alto.&lt;/li&gt;&#xA;&lt;li&gt;&lt;strong&gt;Variantes herméticas&lt;/strong&gt; (folhas deslizantes que descem e se pressionam contra o batente) são abordadas no Capítulo 22.&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;&lt;h2 id=&#34;acionamento-controlador-e-sensores&#34;&gt;Acionamento, controlador e sensores&lt;/h2&gt;&#xA;&lt;p&gt;Os operadores modernos utilizam um motor DC sem escovas que aciona uma correia dentada sobre um trilho montado no cabeçote, com um controlador microprocessado gerenciando perfis de velocidade, tempo de abertura mantida, detecção de obstáculos e comportamento fail-safe ou fail-secure com bateria de reserva em caso de falta de energia.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 27. Dimensões de Portas, Aberturas e Personalização</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/product-selection-and-system-configuration/door-dimensions-openings-customisation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/product-selection-and-system-configuration/door-dimensions-openings-customisation/</guid>
				<description>&lt;p&gt;Um hospital no Sudeste Asiático recebeu um contentor de portas para blocos operatórios encomendadas na medida &amp;ldquo;padrão 900 × 2100 mm&amp;rdquo; — e descobriu que os vãos estruturais no local tinham 980 mm de largura, com retornos de parede de 150 mm de profundidade, e que as camas em utilização exigiam uma passagem livre de 1200 mm. Todos os caixilhos tiveram de ser refeitos. As falhas dimensionais são o erro mais comum e mais dispendioso na aquisição transfronteiriça de portas, porque as dimensões num mapa de portas significam coisas diferentes para o fabricante, o instalador e o engenheiro de estruturas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 31. Normas dos EUA e Considerações Regulamentares</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/european-and-us-standards-compliance-and-testing/us-standards-and-regulatory-considerations/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/european-and-us-standards-compliance-and-testing/us-standards-and-regulatory-considerations/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Um distribuidor oferece uma &amp;ldquo;porta automática de nível hospitalar, totalmente em conformidade&amp;rdquo; para um projeto nos EUA. O especificador pergunta: em conformidade com &lt;em&gt;o quê&lt;/em&gt; — uma norma de produto, um método de ensaio ou um código legalmente adotado? No mercado norte-americano, essas são três coisas diferentes, e confundi-las é a maneira mais rápida de ser reprovado em uma análise do AHJ (Authority Having Jurisdiction — Autoridade Competente) ou acabar responsabilizado por uma instalação não conforme.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 34. Comissionamento e Aceitação no Local</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/installation-commissioning-and-maintenance/commissioning-and-on-site-acceptance/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/installation-commissioning-and-maintenance/commissioning-and-on-site-acceptance/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; O empreiteiro diz que as portas estão &amp;ldquo;instaladas e funcionando&amp;rdquo;. A equipe de facilities do hospital as recebe e, em poucas semanas, a porta automática da sala de cirurgia reverte aleatoriamente, a porta da sala de isolamento apresenta vazamento sob pressão negativa, e ninguém tem um registro assinado do que foi de fato testado. O comissionamento é a etapa que converte uma instalação em um sistema &lt;em&gt;verificado&lt;/em&gt; — e produz a documentação que protege todos posteriormente.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 37. OEM, ODM e Fabricação Personalizada para Exportação</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/export-procurement-and-manufacturing-cooperation/oem-odm-custom-manufacturing-export/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/export-procurement-and-manufacturing-cooperation/oem-odm-custom-manufacturing-export/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Um distribuidor europeu quer vender portas de correr herméticas sob a sua própria marca. A fábrica anuncia &amp;ldquo;OEM/ODM bem-vindos&amp;rdquo; no seu website. Oito meses depois, chega o primeiro contentor: o rótulo está correto, mas o controlador do operador utiliza uma interface em chinês, a embalagem colapsou durante o transporte e o certificado menciona uma família de produtos diferente. Colocar uma marca numa porta é fácil; fazer um programa de exportação funcionar é um projeto de engenharia e documentação.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 5. Dimensões da Folha da Porta e Projeto de Engenharia</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/door-leaf-dimensions-and-engineering-design/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/door-leaf-dimensions-and-engineering-design/</guid>
				<description>&lt;p&gt;Um hospital no Oriente Médio encomendou 400 portas com &amp;ldquo;1200 × 2100 mm&amp;rdquo; — a abertura estrutural indicada no quadro do arquiteto. A fábrica produziu folhas de 1200 mm; após a instalação de marcos, batentes e folgas, a abertura livre era de apenas 1080 mm e as camas padrão de pacientes com suportes de soro não passavam sem serem giradas. Todo o pedido teve que ser refeito. Erros dimensionais são os erros mais baratos de cometer e os mais caros de corrigir, porque só são descobertos na instalação.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Chapter 13. Door Core Materials and Structural Design</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/materials-core-structures-and-surface-finishes/door-core-materials/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/materials-core-structures-and-surface-finishes/door-core-materials/</guid>
				<description>&lt;p&gt;Duas portas podem partilhar as mesmas chapas de aço galvanizado, as mesmas dimensões e a mesma pintura — e, no entanto, uma flete e vibra quando empurrada, transmite o som como um tambor e reprova num teste de fogo, enquanto a outra parece sólida e é aprovada. A diferença está inteiramente no núcleo. Os compradores que comparam orçamentos apenas com base na espessura da chapa e no preço ignoram rotineiramente o componente que define a rigidez, o peso, o isolamento e o comportamento ao fogo.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Chapter 40. Intensive Care, Isolation and Patient Care Areas</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/intensive-care-isolation-patient-care/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/intensive-care-isolation-patient-care/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Uma reforma de UTI mantém as portas de batente existentes de 1000 mm para economizar orçamento. Seis meses depois, a equipe relata a mesma história em todos os turnos: camas com ventiladores e suportes de soro precisam de três pessoas para passar pela porta, os enfermeiros não conseguem ver o paciente do corredor, e o único quarto de isolamento não mantém pressão negativa porque o vão inferior da porta está errado. As portas estão &amp;ldquo;em conformidade&amp;rdquo; — e clinicamente erradas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Classificação das Salas do Bloco Operatório Limpo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/classification-rooms/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/classification-rooms/</guid>
				<description>&lt;p&gt;Os diversos tipos de salas limpas do departamento cirúrgico limpo são salas limpas biológicas, e seu objetivo principal é o controle de partículas viáveis; portanto, esses tipos de salas limpas devem ser classificados com base na concentração bacteriana presente no ar.&lt;/p&gt;&#xA;&lt;h2 id=&#34;321-classificação-das-salas-de-cirurgia-limpa&#34;&gt;3.2.1 Classificação das Salas de Cirurgia Limpa&lt;/h2&gt;&#xA;&lt;p&gt;A classificação das salas de cirurgia limpa é apresentada na Tabela 3.4.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Tabela 3.4 Padrões de classe para salas de cirurgia limpa na China (estado construído ou em repouso)&lt;/strong&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Configuração de gás</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/medical-gases/gas-configuration/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/medical-gases/gas-configuration/</guid>
				<description>&lt;p&gt;A pressão, a vazão e a configuração de quantidade dos vários gases no centro cirúrgico limpo são apresentadas nas Tabelas 8.2 e 8.3.&lt;/p&gt;&#xA;&lt;p&gt;Tabela 8.2 Número mínimo de pontos de conexão configurados para os principais tipos de gás no centro cirúrgico limpo&lt;/p&gt;&#xA;&lt;table&gt;&#xA;&#x9;&lt;thead&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Departamento&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Oxigênio&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Sucção por pressão negativa&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Ar comprimido&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Óxido nitroso&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Nitrogênio&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/thead&gt;&#xA;&#x9;&lt;tbody&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Sala operatória&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Sala de recuperação&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;2&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Sala de pré-anestesia&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;p&gt;&lt;strong&gt;Tabela 8.3 Pressão terminal, vazão e tempo de uso diário&lt;/strong&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Centro Cirúrgico Limpo do Quinto Hospital Afiliado da Universidade de Ciências Médicas Sun Yat-sen (Zhuhai)</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/fifth-affiliated-hospital-sun-yat-sen-zhuhai/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/fifth-affiliated-hospital-sun-yat-sen-zhuhai/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O departamento cirúrgico está localizado no quinto andar do edifício, com um total de 10 salas cirúrgicas limpas e 5 salas cirúrgicas gerais. A área construída é de 2748 m². Entrou em funcionamento em 3 de setembro de 2002 e foi testado pelo Centro Provincial de Prevenção Epidêmica de Guangdong.&lt;/p&gt;&#xA;&lt;h2 id=&#34;ii-layout-da-planta-baixa&#34;&gt;II. Layout da Planta Baixa&lt;/h2&gt;&#xA;&lt;p&gt;O tipo de planta do departamento cirúrgico limpo pertence ao modelo de recuperação periférica. A concepção deste modelo parte do conceito de prevenção de infecções, no qual o manuseio de itens contaminados após as cirurgias é de extrema importância. As características de projeto desta planta são:&lt;/p&gt;</description>
			</item>
			<item>
				<title>Diferença Mínima de Pressão Estática</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/minimum-static-pressure-difference/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/minimum-static-pressure-difference/</guid>
				<description>&lt;p&gt;A primeira coluna de pressão estática mínima da Tabela 4.1 refere-se ao grau da diferença mínima de pressão estática entre as salas limpas de cada classe e as salas limpas de classe inferior adjacentes durante a operação do sistema de ar condicionado e purificação. O requisito de pressão positiva corresponde tanto à exigência do departamento cirúrgico limpo em relação à área não limpa externa quanto ao requisito de pressão positiva relativa entre as salas limpas internas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Gestão de Pessoal</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/personnel-management/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/personnel-management/</guid>
				<description>&lt;h2 id=&#34;1321-gestão-de-vestimentas-do-pessoal-da-sala-cirúrgica&#34;&gt;13.2.1 Gestão de Vestimentas do Pessoal da Sala Cirúrgica&lt;/h2&gt;&#xA;&lt;p&gt;Objetivo da gestão de vestimentas: O corpo humano é a principal fonte de contaminação biológica na sala cirúrgica, e as vestimentas da sala cirúrgica devem ser projetadas para melhorar a limpeza do ambiente. As vestimentas da sala cirúrgica também incluem toucas, máscaras, óculos de proteção e outros itens, que atuam como barreiras de proteção entre a equipe e os pacientes.&lt;/p&gt;&#xA;&lt;p&gt;(1) Todo pessoal que entrar nas áreas limpas e ultralimpas da sala cirúrgica deve usar vestimentas que estejam em conformidade com as normas de vestimenta:&lt;/p&gt;</description>
			</item>
			<item>
				<title>Lâmpada sem sombra</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/shadowless-lamp/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/shadowless-lamp/</guid>
				<description>&lt;h2 id=&#34;621-foco-cirúrgico&#34;&gt;6.2.1 Foco Cirúrgico&lt;/h2&gt;&#xA;&lt;p&gt;Para minimizar o impacto de obstruções no fluxo de ar limpo, é necessário que o foco cirúrgico possua uma carcaça aerodinâmica; por esse motivo, são comumente utilizados focos cirúrgicos de múltiplas cabeças, conforme mostrado nas Figuras 6.2 e 6.3.&lt;/p&gt;&#xA;&lt;p&gt;Figura 6.2 Um tipo de foco cirúrgico&lt;/p&gt;&#xA;&lt;p&gt;Figura 6.3 Um tipo de foco cirúrgico de armação&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 Em uma sala cirúrgica moderna, o plenum de insuflamento de ar (comumente conhecido como teto de insuflamento de ar) está posicionado diretamente acima da mesa cirúrgica, e o foco cirúrgico também se localiza exatamente no centro desse plenum. Dessa forma, o formato do foco cirúrgico frequentemente obstrui o fluxo de ar insuflado e gera vórtices. Quando um foco cirúrgico convencional do tipo prato é posicionado em um fluxo de ar vertical, sua principal região de vórtice se encontra na parte superior da mesa cirúrgica. Ensaios demonstram que o comprimento do vórtice é aproximadamente 5 vezes a largura dessa obstrução (folga de instalação); portanto, para obstruções relativamente grandes, como os focos cirúrgicos&#xA;Quando o objeto se encontra no interior do fluxo de ar insuflado, um conjunto de valores medidos fornecido pela empresa japonesa Yamada pode ser utilizado como referência (Figura 6.4); quando o diâmetro de um foco com cúpula aerodinâmica é de 20 cm, o vórtice por ele gerado desaparece a aproximadamente duas vezes o diâmetro abaixo do foco.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Partículas</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/particles/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/particles/</guid>
				<description>&lt;p&gt;As partículas abordadas neste livro referem-se a partículas presentes no meio aéreo, com tamanhos que variam de $10^{-7} \sim 10^{-1}$ cm. À medida que o tamanho da partícula se altera, suas propriedades físicas e seu comportamento também se modificam correspondentemente. As partículas no meio aéreo são geralmente denominadas poeira atmosférica, e correspondem a partículas sólidas ou líquidas com tamanho inferior a $100\mu m$.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Partículas em suspensão&lt;/strong&gt; (Partículas aerotransportadas)&lt;/p&gt;&#xA;&lt;p&gt;Partículas presentes no meio aéreo; partículas sólidas ou líquidas com tamanho inferior a $10\mu m$, também denominadas partículas totais em suspensão.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Planta de Layout do Bloco Operatório Limpo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/architecture/plan-layout-clean-operating-department/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/architecture/plan-layout-clean-operating-department/</guid>
				<description>&lt;h2 id=&#34;521-princípios-de-layout-planificado-do-departamento-cirúrgico-limpo&#34;&gt;5.2.1 Princípios de Layout Planificado do Departamento Cirúrgico Limpo&lt;/h2&gt;&#xA;&lt;p&gt;(1) Deve atender aos requisitos de higiene e processos médicos (técnica asséptica, fluxos de pessoas e mercadorias, e separação clara entre limpo e sujo).&lt;/p&gt;&#xA;&lt;p&gt;(2) Devem ser controladas as vias de contaminação em todos os aspectos e ao longo de todo o processo (incluindo purificação de ar do departamento cirúrgico, entrega e distribuição de itens estéreis, armazenamento, operações de técnica asséptica e tratamento de desinfecção dos itens após o uso).&lt;/p&gt;</description>
			</item>
			<item>
				<title>Princípios para a construção de um centro cirúrgico limpo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/general-provisions/principles-constructing-clean-operating-department/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/general-provisions/principles-constructing-clean-operating-department/</guid>
				<description>&lt;h2 id=&#34;221-princípios-para-a-construção-de-um-centro-cirúrgico-limpo&#34;&gt;2.2.1 Princípios para a Construção de um Centro Cirúrgico Limpo&lt;/h2&gt;&#xA;&lt;p&gt;Estes princípios se aplicam a:&lt;/p&gt;&#xA;&lt;p&gt;(1) Projetos de construção nova.&lt;/p&gt;&#xA;&lt;p&gt;(2) Projetos de renovação.&lt;/p&gt;&#xA;&lt;p&gt;(3) Projetos de expansão.&lt;/p&gt;&#xA;&lt;p&gt;(4) Salas de cirurgia limpas e salas auxiliares construídas dentro de um centro cirúrgico (área) não limpo.&lt;/p&gt;&#xA;&lt;p&gt;(5) Salas de cirurgia limpas e suas salas auxiliares em centros cirúrgicos (áreas) limpos descentralizados.&lt;/p&gt;&#xA;&lt;p&gt;(6) De uma a várias salas de cirurgia limpa de caráter experimental e suas salas auxiliares.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Requisitos de Proteção Contra Incêndios para Decoração de Interiores</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/interior-decoration-fire-requirements/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/interior-decoration-fire-requirements/</guid>
				<description>&lt;p&gt;O projeto de decoração interna de edificações faz parte do projeto arquitetônico. Os materiais utilizados na decoração são, em sua maioria, relativamente sensíveis ao fogo, e a grande maioria dos incêndios em edificações começa a se alastrar e se expandir a partir do interior. Portanto, o desempenho de combustão dos materiais de decoração interna é um dos fatores importantes que afetam as condições do incêndio, o desenvolvimento do fogo e a segurança das pessoas. As principais influências dos materiais de decoração no incêndio e na segurança das pessoas incluem os seguintes aspectos: afetam a taxa de crescimento do fogo desde a ignição até o &lt;em&gt;flashover&lt;/em&gt;, aumentam a densidade de carga de incêndio, geram fumaça tóxica e reduzem a visibilidade interna. Portanto, o projeto de decoração interna de uma edificação deve levar em consideração as necessidades de proteção contra incêndio da construção.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Requisitos de Qualidade da Água</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/water-supply-drainage/water-quality-requirements/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/water-supply-drainage/water-quality-requirements/</guid>
				<description>&lt;h2 id=&#34;921-água-fornecida-ao-bloco-operatório-limpo&#34;&gt;9.2.1 Água Fornecida ao Bloco Operatório Limpo&lt;/h2&gt;&#xA;&lt;p&gt;A sua qualidade deve cumprir a norma de qualidade da água potável, e a água para a escovação cirúrgica das mãos deve, preferencialmente, ser submetida a tratamento de remoção de bactérias.&lt;/p&gt;&#xA;&lt;p&gt;A água fornecida ao bloco operatório limpo deve cumprir a norma nacional em vigor &amp;ldquo;Especificações Higiênicas para a Qualidade da Água Potável&amp;rdquo; (Wei Fa Jian Fa {2001} N.º 161); este é o requisito mais básico. Em muitos países, a qualidade da água distribuída pelas estações de tratamento de água urbanas cumpre as normas de água potável, e em diversas nações de todo o mundo é possível beber água da torneira diretamente, bastando abrir a torneira. No entanto, a realidade na China é que a água da torneira sofre poluição secundária (proliferação de bactérias, formação de ferrugem, etc.) devido ao transporte de longa distância através da rede de tubagens de abastecimento hídrico, ao armazenamento prolongado em recipientes de reserva de água e ao contacto com o ambiente insalubre circundante. A água de poço de abastecimento próprio gerida por unidades individuais está igualmente sujeita a contaminação devido a uma gestão não normalizada. Por conseguinte, a água da torneira deve dispor de dispositivos de retratamento adicionais, como filtragem e desinfeção, antes da sua utilização. Tal encontra-se claramente estipulado no Artigo 7.º, n.º 8, do Regulamento Municipal de Pequim sobre a Supervisão e Administração da Higiene da Água Potável de Uso Doméstico, bem como no novo código que será emitido em breve. Sabe-se que, nos edifícios onde são instalados sistemas de abastecimento de água com pressurização secundária, compostos por reservatórios de água e dispositivos de desinfeção secundária, a qualidade dos reservatórios, as condições higiénicas dos locais de instalação e a gestão dos equipamentos de desinfeção são muito pouco normalizados, pelo que, na prática, a desinfeção secundária não se encontra garantida. Por esse motivo, no departamento cirúrgico, para a água de escovação sujeita a requisitos mais rigorosos, é aconselhável selecionar equipamentos de remoção de bactérias de pequena escala para tratamento de redesinfeção. Por exemplo, podem ser utilizados dispositivos de desinfeção e esterilização de água como filtros cerâmicos, esterilizadores ultravioleta, sistemas de ozônio e de dióxido de cloro, para filtrar as impurezas da água e eliminar as bactérias nela presentes.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Requisitos para Instalações de Distribuição e Consumo de Energia Elétrica</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/power-distribution/power-distribution-consumption-facilities/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/power-distribution/power-distribution-consumption-facilities/</guid>
				<description>&lt;p&gt;(1) O bloco cirúrgico limpo deve contar com um painel de distribuição de energia principal instalado de forma independente.&lt;/p&gt;&#xA;&lt;p&gt;O painel de distribuição principal deve estar localizado na área não limpa, principalmente para que o pessoal de manutenção possa trabalhar com comodidade durante as atividades de manutenção e reparo sem precisar acessar a área limpa, evitando que poeira e bactérias sejam levadas para o interior da área limpa e reduzindo os fatores de infecção cruzada.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sistema de Ar Condicionado de Purificação do Bloco Operatório Limpo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/air-conditioning-system/purification-air-conditioning-system/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/air-conditioning-system/purification-air-conditioning-system/</guid>
				<description>&lt;h2 id=&#34;721requisitos-especiais&#34;&gt;7.2.1　Requisitos Especiais&lt;/h2&gt;&#xA;&lt;p&gt;O sistema de ar condicionado limpo é um elo fundamental para a estruturação do sistema geral de garantia do departamento cirúrgico. É exigido que o sistema controle os parâmetros internos de salas de classes correspondentes e mantenha o sentido do fluxo de ar entre salas de diferentes classes; é claro, o ponto mais importante de todos é o controle efetivo da concentração bacteriana nas áreas controladas, especialmente nas salas cirúrgicas limpas. No entanto, os sistemas de ar condicionado convencionais, especialmente os equipamentos de troca de calor e umidade integrados a eles, costumam ser locais propícios à proliferação bacteriana e ao acúmulo de poeira, e por isso não conseguem atender aos requisitos do sistema de garantia do departamento cirúrgico limpo. Em comparação com as exigências de ar condicionado de edifícios comuns, esse sistema deve apresentar as seguintes características:&lt;/p&gt;</description>
			</item>
			<item>
				<title>Um Novo Patamar na Construção de Departamentos Cirúrgicos Limpos Hospitalares na China</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/china-clean-operating-department-standard-introduction/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/china-clean-operating-department-standard-introduction/</guid>
				<description>&lt;h2 id=&#34;121-a-importância-e-o-papel-da-elaboração-da-norma-e-do-código&#34;&gt;1.2.1 A Importância e o Papel da Elaboração da Norma e do Código&lt;/h2&gt;&#xA;&lt;p&gt;Com o desenvolvimento da ciência médica na China, o aprimoramento da tecnologia médica e as mudanças na demanda da população por assistência à saúde, os hospitais se deparam com tarefas cada vez mais volumosas de novas construções e expansões; as técnicas cirúrgicas dos diversos departamentos médicos tornaram-se progressivamente mais avançadas, difíceis e complexas, e os requisitos de limpeza e funcionalidade das salas de cirurgia estão cada vez mais elevados. Segundo estatísticas, em 1998 havia 16.468 hospitais em todo o território nacional, dos quais 15.270 eram hospitais de nível de condado ou hierarquia superior, 7.498 contavam com mais de 100 leitos e 788 possuíam mais de 500 leitos. Na época, cerca de cem hospitais já contavam com centros cirúrgicos (salas de cirurgia) adaptados para o padrão limpo, o que representava 0,75% do total. Consequentemente, diversas instituições médicas passaram a competir na renovação de suas salas de cirurgia; quando da realização do &amp;ldquo;Simpósio Internacional de Projeto Arquitetônico e Equipamentos Hospitalares&amp;rdquo;, em Pequim, no ano de 1998, a atenção voltada para a construção de centros cirúrgicos hospitalares já era um tema de destaque, considerando-se que o centro cirúrgico hospitalar é o elo central do controle de infecções hospitalares e um dos marcadores do nível técnico de um hospital. Desde então, cerca de mil novas salas de cirurgia limpas entraram em construção anualmente. No entanto, a China nunca havia contado com normas e códigos unificados para a construção de centros cirúrgicos limpos. Embora o Código Técnico Arquitetônico para Centros Cirúrgicos Limpos de Hospitais Militares, promulgado em 1995, tenha desempenhado um papel marco no estímulo a avanços no setor, ele não possuía, afinal, força vinculante expressiva para a grande maioria dos hospitais locais; além disso, uma série de empresas de engenharia com atuação estrangeira, valendo-se do respaldo das normas nacionais de seus países de origem, geraram um cenário de coexistência de múltiplas normas nacionais. Devido à ausência de normas orientadoras aplicáveis e de diretrizes corretas para o setor, os problemas existentes se manifestavam principalmente nos quatro pontos a seguir: ① as instituições responsáveis pela execução da construção e renovação de salas de cirurgia limpas não possuíam certificação de qualificação, e uma parcela considerável delas não dispunha de corpo técnico profissional nem capacidade de projeto e execução de obras, muito menos possuíam familiaridade com as características específicas dos centros cirúrgicos limpos; ② fabricantes de diversos segmentos ingressaram no setor de forma afoita e desordenada, e a qualidade dos equipamentos para salas de cirurgia limpas não era garantida, fazendo com que grande parte dos produtos comercializados no mercado fosse de qualidade inferior; ③ a contratação e subcontratação de obras não seguiam os trâmites regulamentares, o mercado de construção e renovação de salas de cirurgia limpas apresentava concorrência desordenada e um estado de descontrole grave, além de haver grande desperdício de recursos financeiros: construídas segundo as chamadas normas estrangeiras, uma única sala de cirurgia tinha um custo adicional de cerca de 300 mil a 400 mil yuanes; ④ os projetos de salas de cirurgia concluídos não passavam por inspeção de aceitação de obra nem por avaliação abrangente, e não havia um órgão responsável por verificar a qualidade global dos empreendimentos. Em suma, por um lado, a qualidade dos projetos apresentava queda; por outro, a tendência de buscar soluções novas e de alta gama mostrava expansão contínua. Por esse motivo, o Departamento de Planejamento e Finanças do Ministério da Saúde, órgão competente da área de saúde, decidiu incluir a elaboração de normas nacionais unificadas de construção e de códigos técnicos arquitetônicos para centros cirúrgicos limpos na agenda de implementação imediata. Quanto mais cedo nossas próprias normas e códigos fossem elaborados, mais cedo os resultados seriam percebidos na construção de centros cirúrgicos hospitalares, no desenvolvimento da indústria nacional de salas de cirurgia, no uso racional de investimentos e demais áreas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 14. Tratamentos de Superfície e Acabamentos Higiênicos</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/materials-core-structures-and-surface-finishes/surface-treatments/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/materials-core-structures-and-surface-finishes/surface-treatments/</guid>
				<description>&lt;p&gt;A equipe de controle de infecções de um hospital rejeita um conjunto de portas recém-instalado porque o revestimento não suporta o desinfetante à base de cloro presente na lista de limpeza aprovada — o acabamento esbranquiça e perde o brilho em poucas semanas. As portas em si estavam boas; a especificação da superfície, não. Na área da saúde, o acabamento não é decoração: é a superfície de trabalho que será desinfetada várias vezes ao dia durante vinte anos.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 18. Integração de Sistema de Porta Automática</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/manufacturing-processes-and-quality-assurance/automatic-door-system-integration/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/manufacturing-processes-and-quality-assurance/automatic-door-system-integration/</guid>
				<description>&lt;p&gt;Uma porta hermética automática que esmaga um carrinho, abre sozinha sob os diferenciais de pressão da enfermaria ou queima o motor em seis meses quase nunca falha por causa de um motor defeituoso — falha porque o operador, a folha e o sistema de segurança foram integrados como um mero pensamento tardio. Como dimensionar e colocar em serviço corretamente um sistema automático numa porta médica de aço?&lt;/p&gt;&#xA;&lt;h2 id=&#34;instalação-do-motor-e-do-operador&#34;&gt;Instalação do Motor e do Operador&lt;/h2&gt;&#xA;&lt;p&gt;Duas arquiteturas de operadores dominam as portas hospitalares:&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 22. Portas Deslizantes Herméticas para Salas de Cirurgia</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/hermetic-sliding-doors/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/hermetic-sliding-doors/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; O bloco operatório mantém pressão positiva para impedir a entrada de ar contaminado do corredor. Uma porta de correr convencional apresenta fugas em todo o seu perímetro; cada ciclo de abertura bombeia ar. Que porta mantém realmente a cascata — e como verificar essa afirmação?&lt;/p&gt;&#xA;&lt;h2 id=&#34;como-as-portas-de-correr-herméticas-garantem-a-vedação&#34;&gt;Como as portas de correr herméticas garantem a vedação&lt;/h2&gt;&#xA;&lt;p&gt;Uma porta de correr hermética não é apenas uma porta de correr com uma junta. O mecanismo executa duas ações em sequência:&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 3. Construção e Componentes de Portas Hospitalares</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/fundamentals-of-medical-and-cleanroom-doors/medical-door-construction-and-components/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/fundamentals-of-medical-and-cleanroom-doors/medical-door-construction-and-components/</guid>
				<description>&lt;p&gt;Duas portas podem compartilhar o mesmo tamanho nominal, a mesma face de aço de 1,5 mm e a mesma fotografia de catálogo, e ainda assim uma delamina em três anos de serviço em corredor hospitalar enquanto a outra funciona por vinte. A diferença está no interior da folha e nos detalhes que ninguém fotografa: o núcleo, as juntas das bordas, os reforços das ferragens e as vedações.&lt;/p&gt;&#xA;&lt;h2 id=&#34;a-folha-chapas-de-face-e-bordas&#34;&gt;A folha: chapas de face e bordas&lt;/h2&gt;&#xA;&lt;p&gt;Uma porta metálica oca para uso hospitalar consiste em duas chapas de face de aço conformadas e unidas ao redor de um núcleo. A espessura da chapa de face é a primeira decisão de durabilidade. A ANSI/SDI A250.8 define quatro níveis de desempenho com espessuras mínimas: Nível 1 serviço padrão (standard duty) a 0,8 mm (bitola 20), Nível 2 serviço pesado (heavy duty) a 1,0 mm (bitola 18), Nível 3 serviço extrapesado (extra heavy duty) a 1,3 mm (bitola 16) e Nível 4 serviço máximo (maximum duty) a 1,7 mm (bitola 14). Dado o impacto diário de camas e carrinhos, os hospitais devem tratar o Nível 3 (1,3–1,5 mm) como referência mínima para áreas de pacientes, com o Nível 4 para corredores de alto desgaste e departamentos de emergência.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 35. Manutenção, Solução de Problemas e Vida Útil</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/installation-commissioning-and-maintenance/maintenance-troubleshooting-and-service-life/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/installation-commissioning-and-maintenance/maintenance-troubleshooting-and-service-life/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Um conjunto de portas hospitalares com cinco anos de uso falha &amp;ldquo;repentinamente&amp;rdquo;: vedações rasgadas, operador forçando, porta corta-fogo mantida aberta com calço pela equipe porque bate ao fechar. Nenhuma dessas falhas é repentina — são o estado final previsível de inspeções negligenciadas. Portas hospitalares e de salas limpas trabalham mais do que quase qualquer outro elemento da edificação; a manutenção não é opcional e, no caso de portas corta-fogo, é uma exigência normativa (a NFPA 80 determina inspeção anual com registros escritos).&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 38. Perguntas Frequentes e Referência Técnica</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/export-procurement-and-manufacturing-cooperation/faq-and-technical-reference/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/export-procurement-and-manufacturing-cooperation/faq-and-technical-reference/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; As mesmas vinte perguntas aparecem em todos os concursos de portas hospitalares, em todas as chamadas de integração de distribuidores e em todos os RFI de consultores. Este capítulo reúne-as, com respostas curtas e indicações para os capítulos que tratam cada tema em profundidade.&lt;/p&gt;&#xA;&lt;h2 id=&#34;381-questões-de-aquisição&#34;&gt;38.1 Questões de Aquisição&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong&gt;P: Qual é um prazo de entrega realista para portas de aço médicas personalizadas?&lt;/strong&gt;&#xA;Para dimensões OEM padrão de uma fábrica estabelecida, 30–45 dias de produção mais o transporte é o típico; modificações ODM e novas certificações acrescentam semanas a meses. A aprovação de protótipos e as submissões dependem do comprador — as aprovações lentas são a causa mais comum dos &amp;ldquo;atrasos da fábrica&amp;rdquo;. Consulte o capítulo sobre OEM/ODM e fabrico personalizado.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 41. Laboratórios, Salas Limpas e Instalações Farmacêuticas</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/laboratories-cleanrooms-pharmaceutical-facilities/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/laboratories-cleanrooms-pharmaceutical-facilities/</guid>
				<description>&lt;p&gt;&lt;em&gt;Como escolher uma porta que não se torne o ponto mais fraco de uma sala projetada para manter uma diferença de pressão de 10–15 Pa e cumprir uma classe de partículas da norma ISO 14644?&lt;/em&gt;&lt;/p&gt;&#xA;&lt;p&gt;Num laboratório ou num conjunto de salas limpas, o bloco de porta não é um acessório da parede — é uma secção móvel do envelope de contenção. Cada vez que se abre, a cascata de pressão é perturbada; cada junta, vedação e painel de visão é um potencial caminho de fuga ou armadilha de partículas. A seleção de portas para ambientes controlados começa, portanto, pela classificação da sala e pelo regime de pressão, e não por um catálogo de produtos.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 6. Direção de Abertura e Configuração da Porta</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/door-opening-direction-and-configuration/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/door-opening-direction-and-configuration/</guid>
				<description>&lt;p&gt;&lt;strong&gt;Para que lado deve abrir a porta de um corredor de hospital — e por que o inspetor acabou de rejeitar a sua submissão?&lt;/strong&gt; A direção de abertura e a configuração da folha estão entre as primeiras decisões em um quadro de portas, e entre as mais caras de alterar depois que os marcos são soldados nas divisórias. Acertar nesses aspectos exige conciliar a lógica de circulação, o código de saídas de emergência, a acessibilidade e os requisitos de controle de pressão.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Chapter 28. Hardware, Automation and Access Control</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/product-selection-and-system-configuration/hardware-automation-access-control/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/product-selection-and-system-configuration/hardware-automation-access-control/</guid>
				<description>&lt;p&gt;Uma folha de porta de bloco operatório em aço inoxidável de 62 kg, com vedação de abaixamento, chega à obra; o instalador pendura-a nas dobradiças standard de 3 nós do stock do distribuidor. Seis meses depois, a folha cedeu 4 mm, a vedação arrasta e a mola de fecho já não consegue engatar a porta no trinco — por isso, a porta de compartimentação corta-fogo fica escorada aberta com um caixote do lixo. A maioria das falhas em campo das portas hospitalares são falhas de ferragens: componentes subdimensionados para a folha, incompatíveis entre si ou nunca mantidos.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Chapter 32. Performance Testing and Compliance Documentation</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/european-and-us-standards-compliance-and-testing/performance-testing-and-compliance-documentation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/european-and-us-standards-compliance-and-testing/performance-testing-and-compliance-documentation/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Um documento de licitação solicita &amp;ldquo;certificados de ensaio de durabilidade, estanqueidade ao ar, resistência ao fogo e segurança&amp;rdquo;. O fabricante responde com uma declaração CE, uma foto de uma bancada de ensaio e uma alegação de &amp;ldquo;1.000.000 de ciclos&amp;rdquo; sem nenhum relatório que a sustente. Quais documentos realmente constituem evidência — e quais são apenas marketing?&lt;/p&gt;&#xA;&lt;h2 id=&#34;o-que-conta-como-evidência-de-ensaio&#34;&gt;O que conta como evidência de ensaio&lt;/h2&gt;&#xA;&lt;p&gt;Uma evidência credível possui quatro elementos: (1) uma &lt;strong&gt;norma nomeada com sua edição&lt;/strong&gt;, (2) um &lt;strong&gt;relatório ou certificado de um laboratório acreditado&lt;/strong&gt; (ISO/IEC 17025), (3) uma &lt;strong&gt;descrição do espécime&lt;/strong&gt; que corresponda ao produto fornecido (tamanho, configuração, ferragens) e (4) &lt;strong&gt;rastreabilidade&lt;/strong&gt; — número do relatório, data e número de acreditação do laboratório. Uma Declaração de Desempenho ou certificado de conformidade resume os resultados, mas não substitui o relatório de ensaio subjacente quando a alegação é contestada.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Construção e Comissionamento de Gases Medicinais</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/medical-gases/construction-commissioning/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/medical-gases/construction-commissioning/</guid>
				<description>&lt;p&gt;A instalação e o comissionamento de gases medicinais devem ser executados de acordo com os documentos pertinentes às normas YY/T 0186～0187-94.&lt;/p&gt;&#xA;&lt;p&gt;(1) Em conformidade com os requisitos dos desenhos de projeto, elaborar as medidas de organização da construção, o cronograma de avanço do projeto e as tabelas de apoio de equipamentos e materiais.&lt;/p&gt;&#xA;&lt;p&gt;(2) Limpar o canteiro de obras e verificar os diâmetros e os requisitos de velocidade de fluxo das diferentes tubulações de gás com base nos desenhos de projeto. Conferir as aberturas reservadas e coordenar suas posições espaciais com as demais disciplinas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Decoração Arquitetônica</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/architecture/architectural-decoration/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/architecture/architectural-decoration/</guid>
				<description>&lt;h2 id=&#34;531princípios-gerais-da-decoração-predial&#34;&gt;5.3.1　Princípios Gerais da Decoração Predial&lt;/h2&gt;&#xA;&lt;p&gt;(1) A decoração do departamento cirúrgico limpo deve satisfazer tanto os requisitos funcionais de uso quanto os requisitos de processo do sistema de ar-condicionado limpo.&lt;/p&gt;&#xA;&lt;p&gt;(2) A decoração deve ser segura e firme, não ser facilmente danificada por impactos nem suscetível a colapso, e cumprir os requisitos aplicáveis de proteção contra incêndio.&#xA;(3) Camada de acabamento decorativo. Exige-se que seja de fácil limpeza e desinfecção, com bom efeito espacial ambiental.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento do Centro Cirúrgico Limpo do Primeiro Hospital Popular da Cidade de Changzhou, Província de Jiangsu</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/changzhou-first-peoples-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/changzhou-first-peoples-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O novo complexo de edifícios de internação possui área construída de 45.000 m² e 18 andares. O mezanino técnico está localizado acima do quarto andar. O departamento cirúrgico limpo está situado no terceiro e quarto andares do complexo de edifícios de internação, com área de 1.998 m². O departamento cirúrgico conta com um total de 22 salas cirúrgicas limpas, sendo 2 salas Classe 100, 5 salas Classe 10.000, 6 salas Classe 100.000 e 9 salas Classe 300.000. Entrou em operação em 25 de dezembro de 2002.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Distribuição de ar</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/air-conditioning-system/air-distribution/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/air-conditioning-system/air-distribution/</guid>
				<description>&lt;h2 id=&#34;731-insuflamento-centralizado-de-ar&#34;&gt;7.3.1 Insuflamento Centralizado de Ar&lt;/h2&gt;&#xA;&lt;p&gt;(1) Nas salas de cirurgia limpas das Classes Ⅰ–Ⅲ, as saídas de insuflamento de ar devem ser dispostas centralizadamente acima da mesa cirúrgica, de modo que a mesa cirúrgica e sua zona circundante se localizem na zona de fluxo principal formada pelo ar limpo em escoamento. A zona Classe 100 das salas auxiliares limpas Classe Ⅰ também deve ter saídas de insuflamento dispostas centralizadamente acima de sua área. A área das saídas de insuflamento deve ser selecionada conforme os valores listados na Tabela 7.15, não podendo exceder 1,2 vezes esses valores. Para salas de cirurgia limpas Classe Ⅳ e salas auxiliares de todas as classes, as saídas de insuflamento podem adotar a disposição dispersa convencional.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Distribuição do Tamanho das Partículas</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/particle-size-distribution/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/particle-size-distribution/</guid>
				<description>&lt;p&gt;Os tamanhos das partículas são distribuídos como distribuição de frequência e distribuição cumulativa, e são uma função do tamanho das partículas.&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 Se for expressa como a porcentagem do número de partículas de diferentes tamanhos em um grupo de partículas em relação ao número total, ela é chamada de distribuição de frequência do número de partículas por tamanho, ou simplesmente distribuição de frequência do tamanho das partículas.&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 Se for expressa como a porcentagem do número de partículas com tamanho maior ou igual a um determinado tamanho em um grupo de partículas em relação ao número total, ela é chamada de distribuição cumulativa do tamanho das partículas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Gestão Ambiental</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/environmental-management/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/environmental-management/</guid>
				<description>&lt;h2 id=&#34;1331-responsabilidades-do-pessoal-da-sala-operatória-na-gestão-ambiental&#34;&gt;13.3.1 Responsabilidades do Pessoal da Sala Operatória na Gestão Ambiental&lt;/h2&gt;&#xA;&lt;p&gt;O objetivo da gestão ambiental: ao levar em conta tanto a qualidade da assistência de enfermagem quanto a segurança do pessoal, os profissionais da sala operatória devem minimizar a quantidade de resíduos, para que estes atendam aos padrões de descarte e os custos sejam controlados.&lt;/p&gt;&#xA;&lt;p&gt;(1) Todos os colaboradores devem ter consciência ambiental e economizar energia, como água e eletricidade.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Inspeção do Projeto</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/construction-acceptance/project-inspection/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/construction-acceptance/project-inspection/</guid>
				<description>&lt;h2 id=&#34;1231-itens-de-teste-obrigatórios-para-inspeção-de-engenharia&#34;&gt;12.3.1 Itens de Teste Obrigatórios para Inspeção de Engenharia&lt;/h2&gt;&#xA;&lt;p&gt;Os itens de teste obrigatórios estão especificados no &lt;em&gt;Código&lt;/em&gt; e listados na Tabela 12.11.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Tabela 12.11 Itens de Teste Obrigatórios&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;table&gt;&#xA;&#x9;&lt;thead&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Aceite de conclusão&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Avaliação de desempenho abrangente&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/thead&gt;&#xA;&#x9;&lt;tbody&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Vazão de ar e velocidade de rotação dos ventiladores&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Velocidade transversal no plano de trabalho da zona operacional de cada sala cirúrgica limpa Classe Ⅰ e da zona local Classe 100 de salas auxiliares Classe Ⅰ&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Vazão de ar de sistemas e salas e seu balanceamento&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Taxa de renovação de ar de salas cirúrgicas limpas de outras classes e salas auxiliares&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Pressão estática de sistemas e salas e seu ajuste&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Diferença de pressão estática&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Operação conjunta do sistema de controle automático&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classe de limpeza&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Teste de vazamento de filtro HEPA&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Temperatura e umidade&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classe de limpeza&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Ruído&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classe de limpeza&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Iluminância&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classe de limpeza&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Vazão de ar fresco&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classe de limpeza&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Concentração bacteriana&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;h2 id=&#34;1232-itens-de-teste-para-recebimento-de-avaliação&#34;&gt;12.3.2 Itens de Teste para Recebimento de Avaliação&lt;/h2&gt;&#xA;&lt;p&gt;Os itens de teste necessários para o recebimento de avaliação do projeto do centro cirúrgico limpo estão listados na Tabela 12.12.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Leis e regulamentos relevantes a serem seguidos</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/general-provisions/relevant-laws-regulations/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/general-provisions/relevant-laws-regulations/</guid>
				<description>&lt;p&gt;Além de implementar a &lt;em&gt;Norma de Construção para o Bloco Operatório Limpo Hospitalar&lt;/em&gt; e o &lt;em&gt;Código Técnico de Arquitetura para o Bloco Operatório Limpo Hospitalar&lt;/em&gt;, a construção do bloco operatório limpo deve também cumprir as leis e regulamentos nacionais relativos à construção económica e às causas de saúde pública, devendo ainda estar em conformidade com as normas e códigos técnicos relevantes.&lt;/p&gt;&#xA;&lt;h2 id=&#34;231-aspetos-da-construção-de-engenharia&#34;&gt;2.3.1 Aspetos da Construção de Engenharia&lt;/h2&gt;&#xA;&lt;p&gt;(1) Leis relacionadas à construção de blocos operatórios limpos hospitalares.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Mesa cirúrgica</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/operating-table/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/operating-table/</guid>
				<description>&lt;p&gt;O lado longo da mesa cirúrgica deve, em geral, estar paralelo ao lado longo da sala cirúrgica, e o centro da superfície da mesa deve coincidir com o centro da sala cirúrgica. As mesas cirúrgicas podem ser classificadas nos tipos manual, elétrico ou hidráulico. As funções de uma mesa cirúrgica manual são exatamente iguais às de uma versão elétrica. Normalmente são disponibilizadas mesas cirúrgicas elétricas; diversos tipos comuns de mesas cirúrgicas de 220V são apresentados na Figura 6.8.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Objetos de Controle do Padrão de Classificação</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/control-objects-classification-standard/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/control-objects-classification-standard/</guid>
				<description>&lt;p&gt;A norma chinesa sobre a classificação dos blocos operatórios limpos indica claramente que os seus objetos de controlo incluem quatro aspetos:&lt;/p&gt;&#xA;&lt;p&gt;(1) Tanto a concentração bacteriana como a classe de limpeza do ar devem ser controladas, ou seja, ambas devem estar em conformidade com a norma.&lt;/p&gt;&#xA;&lt;p&gt;(2) No que diz respeito à concentração bacteriana, pode optar-se por controlar ou a concentração bacteriana aerotransportada ou a concentração bacteriana de sedimentação, ou seja, considera-se aceite a conformidade de qualquer uma das duas com a norma.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Projeto resistente ao fogo e compartimentação de incêndio de edifícios</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/fire-resistant-design-fire-compartmentation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/fire-resistant-design-fire-compartmentation/</guid>
				<description>&lt;h2 id=&#34;1031classificação-de-resistência-ao-fogo-das-edificações&#34;&gt;10.3.1　Classificação de Resistência ao Fogo das Edificações&lt;/h2&gt;&#xA;&lt;p&gt;As normas nacionais da China para projeto de proteção contra incêndio em edificações classificam a resistência ao fogo das edificações em quatro graus — Grau I, Grau II, Grau III e Grau IV — com base na importância da edificação, risco de incêndio, altura da edificação, densidade de carga incendiária, características dos ocupantes, entre outros fatores. O Grau I apresenta o maior desempenho de resistência ao fogo, e o Grau IV, o menor.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Requisitos da Sala de Paramentação</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/water-supply-drainage/scrub-room-requirements/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/water-supply-drainage/scrub-room-requirements/</guid>
				<description>&lt;h2 id=&#34;931-pias-de-escovação-na-sala-de-escovação-do-departamento-cirúrgico-limpo&#34;&gt;9.3.1 Pias de Escovação na Sala de Escovação do Departamento Cirúrgico Limpo&lt;/h2&gt;&#xA;&lt;p&gt;As pias de escovação devem estar equipadas com torneiras de acionamento não manual, sendo fornecidas no máximo 2 torneiras por sala cirúrgica.&lt;/p&gt;&#xA;&lt;p&gt;【Referência】A pia de escovação do departamento cirúrgico limpo deve ser estreita e profunda, com o fundo da pia ligeiramente menor que a largura de sua abertura. Ao realizar a escovação, a pessoa estende os pés para frente para que o corpo possa se aproximar da pia, o que facilita a escovação dos braços; uma pia mais profunda evita que a água suja salpique para fora. Para evitar infecções bacterianas causadas pelo toque das mãos nas torneiras, a pia de escovação deve estar equipada com interruptores de acionamento não manual, e ao lado da pia deve haver um dispensador de sabão com acionamento por contato e um secador de mãos elétrico. Atualmente, as torneiras tipo pescoço de ganso são amplamente utilizadas em pias de escovação de hospitais nacionais; os interruptores de controle mais comuns incluem o tipo acionado por cotovelo (integrado à torneira) e o tipo acionado por pé, além de interruptores acionados por joelho, fotoelétricos e sensores infravermelhos. Independentemente do tipo de interruptor selecionado, sua qualidade deve ser confiável; caso contrário, o andamento da cirurgia será afetado.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sistema de Aterramento Equipotencial</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/power-distribution/equipotential-grounding-system/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/power-distribution/equipotential-grounding-system/</guid>
				<description>&lt;p&gt;&lt;strong&gt;[Referência]&lt;/strong&gt; Para um diagrama esquemático do aterramento equipotencial do departamento cirúrgico limpo, consulte a Figura 11.9; a coletânea de desenhos 97SD567 também pode ser consultada.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Taxa de renovação de ar</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/air-change-rate/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/air-change-rate/</guid>
				<description>&lt;h2 id=&#34;431-influência-da-taxa-de-renovação-de-ar&#34;&gt;4.3.1 Influência da Taxa de Renovação de Ar&lt;/h2&gt;&#xA;&lt;p&gt;Para atingir uma determinada classe de limpeza e grau de assepsia em uma sala limpa, é necessariamente exigido um determinado volume de ar de insuflação, juntamente com uma determinada taxa de renovação de ar e tempo de autolimpeza. A taxa de renovação de ar é o indicador que as salas de operação limpas e as salas auxiliares limpas — exceto as salas de operação Classe Ⅰ e as salas auxiliares limpas Classe Ⅰ — devem cumprir para garantir a limpeza exigida e não exceder o tempo de autolimpeza especificado. Esses três indicadores técnicos estão todos inter-relacionados. No entanto, na prática de engenharia real, para atingir um nível de limpeza superior (em conformidade), o volume de ar de insuflação é frequentemente aumentado, o que invisivelmente aumenta o investimento inicial e eleva os custos operacionais diários; portanto, esta cláusula especifica os limites superior e inferior da taxa de renovação de ar. O volume total de ar de insuflação (ou seja, a taxa de renovação de ar) está relacionado ao volume da sala, à carga interna total, ao número de participantes cirúrgicos na sala, à geração de poeira pelas vestimentas, entre outros fatores. As taxas de renovação de ar previstas no Código levam em conta uma determinada faixa de variação dessas condições; a menos que as condições se alterem de forma muito acentuada, elas geralmente atendem aos requisitos.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Teoria da Zona da Corrente Principal — A Base Teórica para o Arranjo de Saídas de Insuflamento de Ar Concentrado</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/mainstream-zone-theory/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/mainstream-zone-theory/</guid>
				<description>&lt;h2 id=&#34;131-proteção-de-áreas-chave-e-purificação-local&#34;&gt;1.3.1 Proteção de Áreas-Chave e Purificação Local&lt;/h2&gt;&#xA;&lt;p&gt;A norma nacional chinesa, a &lt;em&gt;Norma de Construção para Departamentos de Salas Operatórias Limpas Hospitalares&lt;/em&gt;, está em vigor desde 1º de outubro de 2000.&#xA;Essa norma classifica as salas limpas em 4 graus. Entre elas, as salas operatórias limpas são classificadas de acordo com a concentração bacteriana e a limpeza do ar da área da mesa operatória e da área circundante, sendo essa a primeira vez que esse critério foi adotado internacionalmente. O Artigo 29 da norma estabelece: &amp;ldquo;As salas operatórias limpas de Grau Ⅰ, Ⅱ e Ⅲ devem adotar um modo de insuflamento de ar centralizado local; a área das saídas de insuflamento de ar dispostas centralizadamente, ou seja, o tamanho da zona operatória, deve ser compatível com o grau da sala — não inferior a $6,2\mathrm{m}^2$ para o Grau Ⅰ (sendo que a parte dedicada à cabeceira não deve ser inferior a $1,4\mathrm{m}^2$), não inferior a $4,6\mathrm{m}^2$ para o Grau Ⅱ e não inferior a $3,6\mathrm{m}^2$ para o Grau Ⅲ.&amp;rdquo;&lt;/p&gt;</description>
			</item>
			<item>
				<title>A Concentração Bacteriana É a Base da Classificação</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/bacterial-concentration-basis-classification/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/bacterial-concentration-basis-classification/</guid>
				<description>&lt;p&gt;Conforme explicado anteriormente, para as salas de um departamento de cirurgia limpa, que são salas limpas biológicas, a base da classificação é a concentração bacteriana, e este é o principal ponto que as distingue das salas limpas industriais.&lt;/p&gt;&#xA;&lt;h2 id=&#34;341estados-dinâmico-e-estático&#34;&gt;3.4.1　Estados Dinâmico e Estático&lt;/h2&gt;&#xA;&lt;p&gt;A julgar pelos padrões de concentração bacteriana nas diversas classificações apresentadas acima, o &lt;em&gt;Código Técnico de Arquitetura para Departamentos de Cirurgia Limpa em Hospitais&lt;/em&gt; da China especifica o estado estático. O &lt;em&gt;Padrão Higiênico de Desinfecção em Hospitais&lt;/em&gt; estabelece que a medição bacteriana envolve &amp;ldquo;amostragem durante o período após a desinfecção e antes das atividades médicas&amp;rdquo;, o que também indica que os dados são estáticos.&#xA;Por outro lado, diversos padrões estrangeiros devem ser considerados padrões dinâmicos. O padrão britânico na Tabela 3.10 ilustra isso de forma mais clara: ele estipula que, durante a cirurgia, a área a até 30cm da incisão está sujeita a um padrão, enquanto toda a área cirúrgica de 3m×3m está sujeita a outro. O padrão suíço, em sua seção &amp;ldquo;Avaliação da Contagem Bacteriana no Ar&amp;rdquo;, também aponta que, como a contagem bacteriana interna é afetada pelo número de pessoas, seu estado de saúde, seus movimentos e a organização do fluxo de ar (obviamente se trata de uma situação dinâmica — Autor), é inadequado usar a contagem bacteriana naquele momento para avaliar a limpeza e a esterilidade do ar de insuflamento.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Avaliação de Projeto</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/construction-acceptance/project-evaluation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/construction-acceptance/project-evaluation/</guid>
				<description>&lt;p&gt;Para a aceitação do projeto, geralmente é organizada uma equipe de avaliação de aceite pela pessoa jurídica para realizar inspeção no local. Os defeitos de engenharia encontrados durante a inspeção no local são classificados em defeitos graves e defeitos gerais: quaisquer itens chave que estejam incompletos ou ausentes constituem defeitos graves; quaisquer itens gerais que estejam incompletos ou ausentes constituem defeitos gerais.&lt;/p&gt;&#xA;&lt;p&gt;No momento da aceitação, não deve haver defeitos graves, e a proporção de defeitos gerais geralmente não deve exceder 20% dos itens inspecionados.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 15. Blindagem contra Radiação e Materiais para Fins Especiais</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/materials-core-structures-and-surface-finishes/radiation-shielding/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/materials-core-structures-and-surface-finishes/radiation-shielding/</guid>
				<description>&lt;p&gt;Uma sala de radiologia passa nos testes de aceitação dos equipamentos, mas o levantamento de radiação pós-instalação encontra taxas de dose acima do limite de projeto no caixilho da porta. A parede foi blindada com equivalência de 2 mm de chumbo; a porta — fornecida como uma &amp;ldquo;porta com blindagem de chumbo&amp;rdquo; genérica — tinha apenas 1 mm, e as reentrâncias do caixilho apresentavam folgas. Na blindagem, o ponto mais fraco define a proteção de toda a sala, e esse ponto é, muito frequentemente, a porta.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 19. Controle de Qualidade de Fábrica e Testes de Produtos</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/manufacturing-processes-and-quality-assurance/factory-quality-control-product-testing/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/manufacturing-processes-and-quality-assurance/factory-quality-control-product-testing/</guid>
				<description>&lt;p&gt;Duas portas médicas de aço podem parecer idênticas na doca de carga e comportar-se de forma completamente diferente no terceiro ano — uma delaminando no núcleo, a outra ainda vedando perfeitamente. A diferença quase sempre pode ser rastreada até o que foi inspecionado na fábrica. Quais pontos de controle de qualidade e testes realmente preveem o desempenho em campo?&lt;/p&gt;&#xA;&lt;h2 id=&#34;inspeção-de-recebimento-iqc&#34;&gt;Inspeção de Recebimento (IQC)&lt;/h2&gt;&#xA;&lt;p&gt;A qualidade começa antes da fabricação:&lt;/p&gt;&#xA;&lt;ul&gt;&#xA;&lt;li&gt;&lt;strong&gt;Certificados de materiais&lt;/strong&gt; — certificados de usina das bobinas de aço (grau, massa de revestimento para material galvanizado) verificados em relação à especificação de compra; aço inoxidável verificado por grau (304 vs 316) com teste PMI onde existe risco de substituição.&lt;/li&gt;&#xA;&lt;li&gt;&lt;strong&gt;Condição da chapa&lt;/strong&gt; — espessura medida, superfície livre de ferrugem, óleo e arranhões; filme protetor intacto nas faces estéticas.&lt;/li&gt;&#xA;&lt;li&gt;&lt;strong&gt;Ferragens e componentes&lt;/strong&gt; — dobradiças, fechaduras, fechadores, motores e sensores verificados em relação a amostras aprovadas e certificações (graus de dobradiças EN 1935, fechadores EN 1154, conformidade de sensores EN 16005 para sistemas automáticos).&lt;/li&gt;&#xA;&lt;li&gt;&lt;strong&gt;Materiais do núcleo&lt;/strong&gt; — verificações de densidade para lã de rocha e colmeia; núcleos resistentes ao fogo verificados em relação às evidências de ensaio correspondentes à classificação da porta.&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;&lt;p&gt;Rejeitar material não conforme na doca é barato; descobri-lo após a pintura a pó significa descartar produto acabado.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 29. Vedação, Estanqueidade e Controle Ambiental</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/product-selection-and-system-configuration/sealing-airtightness-environmental-control/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/product-selection-and-system-configuration/sealing-airtightness-environmental-control/</guid>
				<description>&lt;p&gt;Uma sala limpa farmacêutica passou a classificação de partículas da ISO 14644 em repouso — e depois falhou o mapeamento de pressão em operação. A causa não era o AVAC: dois conjuntos de portas apresentavam fugas suficientes a 15 Pa para que a cascata entre as zonas de Grau C e Grau D colapsasse sempre que uma porta efetuava um ciclo. As portas eram &amp;ldquo;portas de sala limpa&amp;rdquo; segundo a descrição do catálogo, mas nunca tinha sido especificada uma classe de fuga, pelo que não existia qualquer requisito mensurável contra o qual falhar. A estanquidade ao ar é um número, não um adjetivo.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 42. Radiologia e Outras Áreas Especializadas de Saúde</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/radiology-specialised-healthcare-areas/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/radiology-specialised-healthcare-areas/</guid>
				<description>&lt;p&gt;&lt;em&gt;O relatório de blindagem diz que a porta precisa de equivalência de chumbo de 2 mm — mas quem decide esse valor, e o que acontece se o conjunto de porta que você encomendar não corresponder a ele?&lt;/em&gt;&lt;/p&gt;&#xA;&lt;p&gt;As portas com blindagem contra radiação estão entre os poucos tipos de porta em que um erro é invisível no momento da entrega e só é descoberto durante uma inspeção radiológica pós-instalação — ou pior, durante a operação. Este capítulo aborda portas para diagnóstico por imagem (raio-X, TC), bunkers de radioterapia e duas outras áreas especializadas sobre as quais os compradores perguntam regularmente: processamento de materiais estéreis e espaços de utilidades médicas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 7. Dobradiças, Fechaduras, Puxadores e Ferragens Mecânicas</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/hinges-locks-handles-and-mechanical-hardware/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/hinges-locks-handles-and-mechanical-hardware/</guid>
				<description>&lt;p&gt;&lt;strong&gt;Por que uma porta de UTI com apenas três anos de uso começa a arrastar no piso e deixar de travar?&lt;/strong&gt; Em quase todos os casos, a resposta é a subdimensionamento das ferragens mecânicas: dobradiças selecionadas para uma folha de escritório de 40 kg suportando uma porta hospitalar de 90 kg blindada com chumbo ou envidraçada, ou um fechador dimensionado pelo preço e não pela largura e pelo peso da folha. As ferragens mecânicas são a parte do conjunto da porta que opera milhares de ciclos por semana; a seleção por grau e por aplicação não é opcional.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Chapter 23. Automatic Folding and Swing Doors</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/automatic-folding-and-swing-doors/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/automatic-folding-and-swing-doors/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Uma enfermaria em reabilitação tem corredores estreitos, sem espaço nas paredes para acomodar folhas de correr, e portas corta-fogo que devem fechar automaticamente. A solução de correr é impossível. Dobrável ou de batente automatizada — e como garantir que se mantém segura e acessível?&lt;/p&gt;&#xA;&lt;h2 id=&#34;mecanismos-comparados&#34;&gt;Mecanismos comparados&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong&gt;As portas dobráveis automáticas&lt;/strong&gt; utilizam uma folha articulada de dois painéis que se dobra ao abrir, deslizando num trilho superior ou sendo acionada na dobradiça. A EN 16005 abrange explicitamente os &amp;ldquo;conjuntos de portas dobráveis com folha de movimento horizontal&amp;rdquo;.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Componentes e Materiais de Sistemas de Ar Condicionado</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/air-conditioning-system/components-materials-air-conditioning/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/air-conditioning-system/components-materials-air-conditioning/</guid>
				<description>&lt;h2 id=&#34;741-visão-geral&#34;&gt;7.4.1 Visão geral&lt;/h2&gt;&#xA;&lt;p&gt;Os equipamentos de ar condicionado englobam as unidades de ar condicionado (equipadas com máquina de refrigeração, com capacidade de refrigeração superior a 16,3 kW), os aparelhos de ar condicionado (equipados com máquina de refrigeração, com capacidade de refrigeração inferior a 16,3 kW) e as unidades de tratamento de ar (sem máquina de refrigeração). Eles são os componentes importantes mais utilizados do sistema de ar condicionado para ambientes limpos. Sua fabricação e seleção de materiais devem atender às características da manutenção diária: os requisitos de limpeza, desinfecção, substituição de filtros, prevenção de ferrugem, proteção contra corrosão e drenagem desobstruída diferem daqueles aplicáveis a equipamentos de ar condicionado comuns, especialmente porque esses equipamentos atendem a salas cirúrgicas limpas, onde o controle de bactérias é o objetivo principal. O principal fator que afeta a reprodução bacteriana é a possibilidade de controlar a umidade no interior do equipamento, que costuma ser a condição básica que determina a contaminação microbiana secundária interna. Portanto, deve-se dar atenção suficiente à seleção de materiais de todos os componentes.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Concentração de poeira</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/dust-concentration/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/dust-concentration/</guid>
				<description>&lt;p&gt;A quantidade de poeira contida em uma determinada unidade de ar; essa quantidade pode ser um número ou uma massa.&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 Concentração de poeira refere-se especificamente ao número de partículas em suspensão por unidade de volume de ar.&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 Existem três métodos para expressar a concentração de poeira atmosférica (Tabela 1.1).&lt;/p&gt;&#xA;&lt;p&gt;(1) Concentração numérica: expressa pelo número de partículas de poeira contidas em uma unidade de volume de ar, representada por partículas/$m^3$ ou partículas/L.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento Operatório Limpo do Hospital Popular da Região Autônoma Zhuang de Guangxi</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/guangxi-peoples-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/guangxi-peoples-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O departamento de cirurgia limpa situa-se no sétimo andar do edifício complexo ambulatorial e conta com 18 salas cirúrgicas no total. A área construída do andar cirúrgico é de 3489 m². A obra encontra-se atualmente em construção.&lt;/p&gt;&#xA;&lt;h2 id=&#34;ii-layout-da-planta-baixa&#34;&gt;II. Layout da Planta Baixa&lt;/h2&gt;&#xA;&lt;p&gt;O tipo de planta baixa do departamento de cirurgia limpa corresponde ao modelo de recuperação periférica. O conceito de projeto desse modelo parte da perspectiva de prevenção de infecções, sendo o manuseio de artigos contaminados pós-operatórios de extrema importância. As características de projeto desta planta baixa são:&lt;/p&gt;</description>
			</item>
			<item>
				<title>Diretrizes da AIA para Projeto e Construção de Instalações Hospitalares e de Assistência à Saúde</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/aia-guidelines-hospital-health-care-facilities/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/aia-guidelines-hospital-health-care-facilities/</guid>
				<description>&lt;h2 id=&#34;77-unidade-cirúrgica&#34;&gt;7.7 Unidade Cirúrgica&lt;/h2&gt;&#xA;&lt;p&gt;O número de salas de cirurgia e leitos de recuperação, bem como o tamanho das áreas de apoio, deve se basear na carga de trabalho cirúrgico prevista. No planejamento, o tamanho, a localização e o layout da unidade cirúrgica e dos departamentos de apoio correspondentes devem refletir o número de pacientes ambulatoriais. Ela pode ser projetada como uma unidade de cirurgia ambulatorial ou como uma unidade cirúrgica compartilhada por pacientes internados e ambulatoriais. A unidade cirúrgica deve estar localizada em uma posição que evite corredores de circulação.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Gestão da Qualidade</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/quality-management/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/quality-management/</guid>
				<description>&lt;h2 id=&#34;1341-gestão-de-infecções-e-técnica-asséptica&#34;&gt;13.4.1 Gestão de Infecções e Técnica Asséptica&lt;/h2&gt;&#xA;&lt;p&gt;A gestão de infecções consiste no controle das fontes de infecção provenientes do ambiente, de veículos comuns (materiais e instrumentos médicos), da equipe médica (mãos, nasofaringe e corpo) e dos próprios pacientes em todas as etapas: pré-operatória, intraoperatória e pós-operatória.&lt;/p&gt;&#xA;&lt;p&gt;(1) Fontes de infecção.&lt;/p&gt;&#xA;&lt;p&gt;Os patógenos das infecções de sala de cirurgia provêm principalmente de:&lt;/p&gt;&#xA;&lt;ol&gt;&#xA;&lt;li&gt;&#xA;&lt;p&gt;Pele e cabelos. Qualquer pessoa que entre na sala de cirurgia é uma fonte de contaminação ambiental; a pele, os folículos pilosos, as glândulas sudoríparas e as glândulas sebáceas estão repletos de colônias microbianas, com maior abundância na cabeça e pescoço, axilas, períneo, mãos e pés. Em média, a pele de cada pessoa descama 4 000～10 000 microrganismos por minuto; a causa mais comum de infecção é o &lt;em&gt;Staphylococcus aureus&lt;/em&gt;, e o grau de infecção está relacionado à limpeza da pele e dos cabelos e ao comprimento dos cabelos.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Instalações de Drenagem</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/water-supply-drainage/drainage-facilities/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/water-supply-drainage/drainage-facilities/</guid>
				<description>&lt;h2 id=&#34;941-equipamentos-de-drenagem-em-salas-de-cirurgia-limpas&#34;&gt;9.4.1 Equipamentos de Drenagem em Salas de Cirurgia Limpas&lt;/h2&gt;&#xA;&lt;p&gt;Válvula Misturadora Termostática Tipo 525&lt;/p&gt;&#xA;&lt;ul&gt;&#xA;&lt;li&gt;Corpo da válvula: Bronze&lt;/li&gt;&#xA;&lt;li&gt;Pistão de regulação e mola: Aço inoxidável&lt;/li&gt;&#xA;&lt;li&gt;Faixa de ajuste de temperatura: 36~53℃&lt;/li&gt;&#xA;&lt;li&gt;Precisão: ±2℃&lt;/li&gt;&#xA;&lt;li&gt;Pressão máxima: 10kg&lt;/li&gt;&#xA;&lt;li&gt;Temperatura máxima da água: 90℃&lt;/li&gt;&#xA;&lt;li&gt;Calibre: $\frac{1}{2}$~2pol.&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;&lt;p&gt;Figura 9.3 Válvula Misturadora Termostática (Tipo 523)&lt;/p&gt;&#xA;&lt;p&gt;Os equipamentos de drenagem devem dispor de um dispositivo de selo hídrico elevado abaixo da saída de drenagem, e devem ser adotadas medidas para evitar que o selo hídrico seja destruído.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Instalações de extinção de incêndios no interior de edifícios</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/fire-extinguishing-facilities/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/fire-extinguishing-facilities/</guid>
				<description>&lt;h2 id=&#34;1041hidrantes-de-incêndio-internos&#34;&gt;10.4.1　Hidrantes de incêndio internos&lt;/h2&gt;&#xA;&lt;p&gt;Um hidrante de incêndio interno é uma instalação básica de extinção de incêndios para controle de incêndios iniciais em edifícios; portanto, geralmente devem ser instalados hidrantes de incêndio internos nos edifícios. Como a carga de incêndio em uma sala de cirurgia limpa é rigorosamente controlada, e mesmo que um hidrante de incêndio seja instalado na sala, muitas vezes ele não pode ser utilizado, de acordo com as disposições do código de projeto de proteção contra incêndio de edifícios, quando são exigidos hidrantes em um edifício, os hidrantes que deveriam ser instalados na sala de cirurgia podem ser realocados para um local próximo, como o corredor do lado de fora da sala de cirurgia. No entanto, independentemente de onde forem instalados, deve ser garantido que eles cumpram sua função pretendida, para que possam ser utilizados para extinguir eficazmente incêndios na sala de cirurgia. Os hidrantes de incêndio dispostos fora da sala de cirurgia devem garantir que os jatos de água sólidos de dois bicos alcancem simultaneamente qualquer parte interna da sala de cirurgia. A demanda de água para incêndio, o raio de proteção dos hidrantes de incêndio, etc., devem cumprir as disposições do código de projeto de proteção contra incêndio de edifícios correspondente.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sistemas de Extra-Baixa Tensão</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/power-distribution/extra-low-voltage-systems/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/power-distribution/extra-low-voltage-systems/</guid>
				<description>&lt;p&gt;(1) Sistema de comunicação.&lt;/p&gt;&#xA;&lt;ol&gt;&#xA;&lt;li&gt;&#xA;&lt;p&gt;Sistema de interfone mãos-livres e seus equipamentos. Os telefones dentro da sala de cirurgia não devem ter conexão direta com o exterior; eles só podem ser utilizados entre salas de cirurgia e entre uma sala de cirurgia e o posto de enfermagem. A comunicação externa do departamento cirúrgico (dentro do hospital) é realizada exclusivamente pela sala de plantão do porteiro ou pelo posto de enfermagem.&lt;/p&gt;&#xA;&lt;/li&gt;&#xA;&lt;li&gt;&#xA;&lt;p&gt;Equipamentos de comunicação sem fio não são permitidos em salas de cirurgia limpas, para evitar que ondas de rádio interfiram em componentes eletrônicos e causem acidentes médicos.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Unidades terminais de gases medicinais</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/medical-gas-terminal-units/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/medical-gas-terminal-units/</guid>
				<description>&lt;p&gt;Os gases medicinais são um dos equipamentos essenciais necessários para o tratamento auxiliar em sala operatória. Na sala, os dispositivos terminais de gás devem ser fornecidos em duplicata (um em uso e um em reserva): um do tipo montado na parede como reserva, e um instalado no pendente cirúrgico como terminal para uso normal. A fonte de gás é transportada das diversas estações de gás por meio de tubulações até os terminais da sala operatória e, quando necessário, é conectada ao paciente ou a instrumentos por meio de plugues.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Velocidade do ar na área de trabalho local Classe 100</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/air-velocity-class-100-work-area/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/air-velocity-class-100-work-area/</guid>
				<description>&lt;h2 id=&#34;441-velocidade-do-ar-na-seção-transversal&#34;&gt;4.4.1 Velocidade do ar na seção transversal&lt;/h2&gt;&#xA;&lt;p&gt;De acordo com o princípio da teoria da velocidade de limite inferior do ar, a velocidade do ar na seção transversal da área de trabalho em fluxo unidirecional vertical deve ser de 0,3 m/s. No entanto, para o fluxo unidirecional vertical local em salas limpas Classe I, nas quais as saídas de ar de insuflamento estão dispostas de forma centralizada conforme especificado pela norma — comumente conhecido como Classe 100 local —, como o fluxo de ar se difunde para a área abaixo da zona Classe 100, e essa difusão é afetada por fatores como a presença de defletores na face de insuflamento e a distância das suas quatro bordas em relação às paredes, medições de campo extensas mostram que 0,3 m/s é um valor bastante rigoroso. Nas antigas &lt;em&gt;Medidas Técnicas para Limpeza do Ar&lt;/em&gt; e &lt;em&gt;Norma de Projeto de Salas Limpas&lt;/em&gt;, esse valor era de 0,25 m/s, mas em relação à altura dos pontos de medição, a primeira especificava dois locais, 0,8 m e 1,5 m, com os resultados a serem calculados por média; a altura do ponto de medição da segunda era de 1 m. A &amp;ldquo;Norma&amp;rdquo;, assim como a &lt;em&gt;Norma de Construção e Aceitação de Salas Limpas&lt;/em&gt;, define a altura do ponto de medição em 0,8 m. Tendo em vista o motivo mencionado acima da disposição centralizada local das saídas de insuflamento, esse valor é especialmente flexibilizado para uma faixa, ou seja, 0,25–0,3 m/s: não é desejável que fique abaixo de 0,25, para não comprometer a capacidade anti-interferência, enquanto um valor excessivamente alto tende a fazer com que a incisão perca umidade muito rapidamente, o que também é indesejável; durante a medição, será utilizado o valor médio.&lt;/p&gt;</description>
			</item>
			<item>
				<title>A limpeza do ar é a condição de salvaguarda necessária para a classificação</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/air-cleanliness-safeguard-classification/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/air-cleanliness-safeguard-classification/</guid>
				<description>&lt;h2 id=&#34;351-condições-de-salvaguarda&#34;&gt;3.5.1 Condições de Salvaguarda&lt;/h2&gt;&#xA;&lt;p&gt;Embora as salas do bloco operatório limpo sejam classificadas pela concentração bacteriana, essa concentração não pode ser efetivamente controlada ao longo de todo o processo apenas pela desinfeção higiénica; a tecnologia de limpeza do ar deve funcionar como condição de salvaguarda necessária para alcançar o controlo processual.&lt;/p&gt;&#xA;&lt;p&gt;Enfatizar que a limpeza do ar é a condição de salvaguarda necessária demonstra que uma sala de cirurgia limpa difere de uma sala de cirurgia comum que apenas foi desinfetada: sem medidas de purificação do ar, o espaço não pode ser considerado uma sala limpa, o que aponta também para a essência do bloco operatório limpo.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 24. Portas de Sala Limpa e Configurações Especiais</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/cleanroom-doors/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/cleanroom-doors/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Uma sala limpa farmacêutica mantém +15 Pa em relação ao corredor. Cada abertura de porta é um evento de contaminação. Que construção de porta, e que lógica de porta, protege efetivamente a classificação?&lt;/p&gt;&#xA;&lt;h2 id=&#34;construção-de-portas-para-salas-limpas&#34;&gt;Construção de portas para salas limpas&lt;/h2&gt;&#xA;&lt;p&gt;As portas de salas limpas diferem das portas hospitalares comuns em três aspectos: superfície, vedação e integração.&lt;/p&gt;&#xA;&lt;ul&gt;&#xA;&lt;li&gt;&lt;strong&gt;Portas de aço niveladas&lt;/strong&gt;: folhas com revestimento em pó ou em aço inoxidável, sem saliências, sem dobradiças expostas sempre que evitável, vidros nivelados com painéis de visão de dupla face e construção soldada em vez de aparafusada. Qualquer elemento que acumule poeira é uma falha de limpeza prestes a acontecer.&lt;/li&gt;&#xA;&lt;li&gt;&lt;strong&gt;Perímetro vedado&lt;/strong&gt;: guarnições de células fechadas nos quatro lados; para graus mais elevados, vedações inferiores retráteis em vez de soleiras elevadas. A permeabilidade ao ar deve ser verificada conforme a EN 12207 (ver Capítulo 22) onde o controle de pressão é crítico.&lt;/li&gt;&#xA;&lt;li&gt;&lt;strong&gt;Compatibilidade de materiais&lt;/strong&gt;: as superfícies devem suportar o regime de desinfecção do local — agentes esporicidas, ciclos de biodecontaminação com vapor de peróxido de hidrogênio (VHP) em salas de grau elevado. Confirme a resistência do revestimento e das guarnições aos produtos químicos efetivamente utilizados; o VHP ataca alguns elastômeros e adesivos.&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;&lt;h2 id=&#34;intertravamentos-e-eclusas&#34;&gt;Intertravamentos e eclusas&lt;/h2&gt;&#xA;&lt;p&gt;O Anexo 1 das GMP da UE define uma eclusa (airlock) como &amp;ldquo;um espaço fechado com portas intertravadas, construído para manter o controle da pressão do ar&amp;rdquo;. Este é o conceito orientador:&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 43. Estudos de Caso de Projetos de Portas Hospitalares</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/medical-door-project-case-studies/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/medical-door-project-case-studies/</guid>
				<description>&lt;p&gt;&lt;em&gt;Como é realmente um pacote de portas quando a teoria encontra um canteiro em operação?&lt;/em&gt;&lt;/p&gt;&#xA;&lt;p&gt;Este capítulo apresenta três &lt;strong&gt;cenários ilustrativos de projetos&lt;/strong&gt;. Trata-se de composições típicas extraídas de padrões comuns de projetos — não são registros de clientes nomeados, hospitais identificados ou projetos certificados. Quantidades, dimensões e requisitos são representativos, não depoimentos. O objetivo é mostrar como as decisões dos capítulos anteriores se concretizam na prática: contexto → restrições do local → decisões técnicas → implementação → verificação.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 8. Motores de Portas Automáticas e Sistemas de Acionamento</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/automatic-door-motors-and-drive-systems/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/automatic-door-motors-and-drive-systems/</guid>
				<description>&lt;p&gt;&lt;strong&gt;Sua porta de correr hermética de 180 kg bate no batente ao fechar e se abre lentamente como um elevador de carga — mesmo modelo de operador da porta de corredor de 80 kg que funciona perfeitamente. Por quê?&lt;/strong&gt; Porque o operador foi especificado apenas pela largura da folha, e não pela carga e pelo ciclo de operação. Este capítulo percorre a cadeia de engenharia em ordem: princípio de funcionamento → condições de carga → correspondência de parâmetros → lógica de controle → diagnóstico de falhas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Cirurgia Limpa do Hospital Popular de Nanhai</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/nanhai-peoples-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/nanhai-peoples-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;Projeto de decoração e purificação de 12 salas de cirurgia limpas, salas auxiliares do corredor limpo e salas auxiliares do corredor contaminado. A área construída do andar cirúrgico é de 1244 m². O empreendimento entrou em operação em 16 de outubro de 2002 e foi testado pelo Centro de Prevenção Epidêmica da Província de Guangdong.&lt;/p&gt;&#xA;&lt;h2 id=&#34;ii-layout-da-planta-baixa&#34;&gt;II. Layout da Planta Baixa&lt;/h2&gt;&#xA;&lt;p&gt;O tipo de planta baixa do departamento cirúrgico limpo pertence ao tipo de recuperação periférica. A concepção deste tipo de planta parte do princípio de prevenção de infecções, no qual o manuseio de itens contaminados após as cirurgias é de extrema importância. As características de projeto desta planta são:&lt;/p&gt;</description>
			</item>
			<item>
				<title>Dispositivos automáticos de alarme de incêndio</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/automatic-fire-alarm-devices/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/automatic-fire-alarm-devices/</guid>
				<description>&lt;p&gt;Um sistema automático de alarme de incêndio é um tipo de instalação automática de proteção contra incêndios instalada em edifícios ou outros recintos, com o objetivo de detetar e reportar incêndios numa fase inicial e adotar medidas eficazes atempadamente para os controlar e extinguir. Em muitos países desenvolvidos, a produção e aplicação de dispositivos ou sistemas automáticos de alarme de incêndio são muito generalizadas.&lt;/p&gt;&#xA;&lt;p&gt;Um sistema automático de alarme de incêndio é geralmente composto por dispositivos de acionamento (como detetores de incêndio e botões manuais de alarme de incêndio), dispositivos de alarme de incêndio, dispositivos de aviso de incêndio e uma fonte de alimentação; os sistemas mais complexos incluem também equipamentos de controlo de incêndio (como dispositivos de controlo de extinção de incêndios, dispositivos de controlo de interligação para elevadores, cortinas corta-fogo, etc., difusão de emergência de incêndio e comunicação de incêndio, iluminação de emergência e outros equipamentos de controlo). Trata-se de um tipo de &amp;hellip; que integra a deteção automática de incêndio e o alarme automático num só, correspondendo a um sistema capaz de realizar controlo automático em conjugação com os equipamentos de interligação associados. As suas formas básicas incluem três categorias: o sistema de alarme local, o sistema de alarme centralizado e o sistema de alarme de centro de controlo.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Gestão de Equipamentos</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/equipment-management/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/equipment-management/</guid>
				<description>&lt;h2 id=&#34;1351-o-sistema-de-ar-condicionado-limpo-é-a-instalação-que-garante-que-o-departamento-cirúrgico-limpo-atenda-aos-padrões-de-nível-de-limpeza-correspondentes&#34;&gt;13.5.1 O sistema de ar condicionado limpo é a instalação que garante que o departamento cirúrgico limpo atenda aos padrões de nível de limpeza correspondentes&lt;/h2&gt;&#xA;&lt;p&gt;O desempenho das instalações do sistema de ar condicionado limpo durante o funcionamento determina diretamente o desempenho do departamento cirúrgico limpo. Portanto, é necessário operar os diversos equipamentos de forma adequada, de acordo com a situação de funcionamento do hospital, monitorar as alterações durante o funcionamento e garantir que os equipamentos operem normalmente.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Japão HEAS-02-1998: Diretrizes para Projeto e Gestão de Equipamentos de Ar-Condicionado Hospitalar</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/japan-heas-02-1998-hospital-air-conditioning/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/japan-heas-02-1998-hospital-air-conditioning/</guid>
				<description>&lt;h2 id=&#34;2ambiente-interno&#34;&gt;2　Ambiente Interno&lt;/h2&gt;&#xA;&lt;h2 id=&#34;21classificação-de-limpeza&#34;&gt;2.1　Classificação de Limpeza&lt;/h2&gt;&#xA;&lt;h2 id=&#34;211política-básica&#34;&gt;2.1.1　Política Básica&lt;/h2&gt;&#xA;&lt;blockquote&gt;&#xA;&lt;p&gt;Cada sala (zona) da instalação deve ser classificada conforme os níveis de limpeza apresentados na Tabela 2.1-1, e o nível de limpeza adequado ao uso de cada sala deve ser mantido.&lt;/p&gt;&#xA;&lt;p&gt;Além disso, quando for implementada a climatização de todo o hospital, as zonas de níveis de limpeza Ⅰ, Ⅱ e Ⅲ devem cumprir os critérios destas diretrizes; para as zonas de nível de limpeza Ⅳ, também é recomendado o cumprimento das regras.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Limpeza do ar</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/air-cleanliness/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/air-cleanliness/</guid>
				<description>&lt;p&gt;A limpeza do ar refere-se ao grau de teor de poeira (particulado) no ar de um ambiente limpo. Quanto maior a concentração de poeira, menor a limpeza; quanto menor a concentração de poeira, maior a limpeza.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;[Referência]&lt;/strong&gt; A limpeza do ar é distinguida pelo número de partículas de um determinado tamanho por unidade de volume; ela própria é adimensional.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Pêndula Médica Multifuncional de Gás</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/medical-multifunctional-gas-pendant/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/medical-multifunctional-gas-pendant/</guid>
				<description>&lt;p&gt;Os pendentes de gases multifuncionais estão disponíveis nos três tipos a seguir.&lt;/p&gt;&#xA;&lt;p&gt;(1) Pendente de gases de elevação elétrica para serviço pesado [Figura 6.11(a)], cujas características são:&lt;/p&gt;&#xA;&lt;p&gt;(a) Pendente de gases de elevação elétrica para serviço pesado&lt;/p&gt;&#xA;&lt;p&gt;(b) Pendente de gases para anestesiologia　　(c) Pendente de gases para cirurgia minimamente invasiva&lt;/p&gt;&#xA;&lt;p&gt;Figura 6.11　Pendentes de gases multifuncionais&lt;/p&gt;&#xA;&lt;ol&gt;&#xA;&lt;li&gt;&#xA;&lt;p&gt;O pendente cirúrgico de elevação elétrica DVE808X pode ser elevado e abaixado eletricamente, com curso de elevação de 600 mm.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Tempo de Autopurificação</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/self-purification-time/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/self-purification-time/</guid>
				<description>&lt;p&gt;O indicador técnico do tempo de autolimpeza é de grande importância para as salas de cirurgia. O tempo de autolimpeza representa o tempo necessário para que a concentração de poeira do ar interno de uma sala de cirurgia caia de um valor inicial elevado para um valor estável após a partida do sistema de ar-condicionado e purificação. Para os usuários, quanto menor esse tempo, melhor. Quanto menor esse tempo, maior a capacidade de autolimpeza da sala de cirurgia e mais rapidamente as partículas de poeira internas podem ser removidas. Como pode ser observado na Tabela 4.1, quanto maior a classe de limpeza da sala de cirurgia, menor o tempo de autolimpeza e maior a capacidade de autolimpeza; quanto menor a classe de limpeza, maior o tempo de autolimpeza e menor sua capacidade de autolimpeza.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Alemanha DIN 1946-4: Sistemas de Tratamento de Ar em Hospitais</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/germany-din-1946-4-hospital-air-handling-systems/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/germany-din-1946-4-hospital-air-handling-systems/</guid>
				<description>&lt;h2 id=&#34;42-qualidade-do-ar-e-limpeza&#34;&gt;4.2 Qualidade do ar e limpeza&lt;/h2&gt;&#xA;&lt;h2 id=&#34;421-classes-de-salas&#34;&gt;4.2.1 Classes de salas&lt;/h2&gt;&#xA;&lt;p&gt;Em hospitais, por razões microbiológicas, são impostos requisitos diferentes à esterilidade do ar de insuflamento e do ar interno. As salas de diferentes áreas de um hospital podem ser divididas nas duas classes a seguir:&lt;/p&gt;&#xA;&lt;ol&gt;&#xA;&lt;li&gt;Classe de salas Ⅰ: é necessária esterilidade alta ou muito alta.&lt;/li&gt;&#xA;&lt;li&gt;Classe de salas Ⅱ: é necessária esterilidade comum.&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;h2 id=&#34;422-limpeza-do-ar&#34;&gt;4.2.2 Limpeza do ar&lt;/h2&gt;&#xA;&lt;p&gt;É necessária filtragem de ar em múltiplos estágios no processo de insuflamento de ar para remover todos os tipos de contaminantes particulados, incluindo microrganismos. A filtragem de dois estágios é utilizada para salas da classe Ⅰ; de acordo com os requisitos de esterilidade alta ou muito alta, a filtragem de três estágios é utilizada em salas da classe Ⅰ.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 44. Entrega de Projetos e Cooperação Internacional</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/project-delivery-international-cooperation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/applications-and-project-case-studies/project-delivery-international-cooperation/</guid>
				<description>&lt;p&gt;&lt;em&gt;As portas estão especificadas, o preço está acordado — então por que os projetos internacionais de portas ainda chegam atrasados, errados, ou ambos?&lt;/em&gt;&lt;/p&gt;&#xA;&lt;p&gt;A maioria das falhas no fornecimento transfronteiriço de portas hospitalares não são falhas de produto. São falhas de coordenação: uma aprovação que ficou parada na caixa de entrada de alguém por três semanas, um mapa de portas revisado depois do início da fabricação, um contêiner carregado com os batentes no fundo e as folhas esmagadas por cima. Este capítulo mapeia a cadeia de entrega — fabricante, arquiteto, empreiteiro, distribuidor — e os pontos de controle que a mantêm funcionando.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 9. Sensores, Controle de Acesso e Intertravamentos de Porta</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/sensors-access-control-and-door-interlocks/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/sensors-access-control-and-door-interlocks/</guid>
				<description>&lt;p&gt;&lt;strong&gt;Um paciente anestesiado é conduzido em direção a uma porta deslizante de centro cirúrgico que se fecha sobre a maca — enquanto, duas portas adiante, uma eclusa de farmácia permite que ambas as portas permaneçam abertas ao mesmo tempo, colapsando a cascata de pressão. Qual subsistema falhou?&lt;/strong&gt; Subsistemas diferentes em cada caso: detecção de presença na primeira porta, lógica de intertravamento na segunda. Sensores e travamento eletrônico são itens de baixo custo no orçamento que carregam a maior parte do risco funcional de um sistema de portas hospitalares.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Chapter 25. Radiation-Shielding, Fire-Rated and Security Doors</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/radiation-fire-security-doors/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/types-of-steel-medical-and-cleanroom-doors/radiation-fire-security-doors/</guid>
				<description>&lt;p&gt;&lt;strong&gt;O problema:&lt;/strong&gt; Uma única abertura de porta — a entrada da sala de TC num corredor que é também uma rota de fuga — tem de bloquear raios X, resistir ao fogo durante 60 minutos, controlar o fumo e restringir o acesso. Estes são quatro problemas de engenharia diferentes. Tratar um certificado como prova dos outros é o erro clássico de aquisição.&lt;/p&gt;&#xA;&lt;h2 id=&#34;portas-de-blindagem-contra-radiação&#34;&gt;Portas de blindagem contra radiação&lt;/h2&gt;&#xA;&lt;p&gt;As salas de raios X de diagnóstico, TC e radioterapia exigem portas com blindagem correspondente ao cálculo de blindagem da sala efetuado pelo físico, expressa como &lt;strong&gt;equivalência em chumbo&lt;/strong&gt; (tipicamente 1–3 mm de Pb para salas de diagnóstico; muito mais para bunkers de terapia).&lt;/p&gt;</description>
			</item>
			<item>
				<title>Classe de Limpeza do Ar</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/air-cleanliness-class/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/air-cleanliness-class/</guid>
				<description>&lt;h3 id=&#34;limite-superior-da-classe-de-limpeza-limite-superior-de-classe-da-classe-de-limpeza&#34;&gt;Limite Superior da Classe de Limpeza (Limite superior de classe da classe de limpeza)&lt;/h3&gt;&#xA;&lt;p&gt;A classe de limpeza do ar é utilizada para distinguir o grau de limpeza do ar e é determinada pelo número máximo permitido de partículas por metro cúbico (ou, quando necessário, por litro) de ar. Esse número máximo permitido de partículas é denominado limite superior de classe da classe de limpeza.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;[Referência]&lt;/strong&gt; Desde que o padrão de distribuição de partículas em papel log-log foi dominado, a norma estadunidense adotou o método de desenhar linhas paralelas em papel log-log para estabelecer classes de limpeza para diferentes tipos de locais.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Cirurgia Limpa do Primeiro Hospital Popular de Hangzhou</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/hangzhou-first-peoples-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/hangzhou-first-peoples-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;Escala de construção: área total de piso de 43.646 m², sendo 2 pisos subterrâneos com 8.375 m² e 15 pisos acima do solo com 35.271 m² (pódio de 5 pisos, com 2.251 m²; edifício principal de 10 pisos, com 12.760 m²; o espaço entre o 4º e o 5º piso é um piso técnico, não computado na área construída do edifício).&lt;/p&gt;&#xA;&lt;p&gt;O centro cirúrgico limpo está localizado no quarto piso do edifício recém-construído do complexo de internação, com área de piso de 2.515 m². O centro cirúrgico conta com um total de 18 salas cirúrgicas limpas. No momento, ele está em construção.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Monitoramento Diário</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/daily-monitoring/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/daily-management-monitoring/daily-monitoring/</guid>
				<description>&lt;p&gt;Recomenda-se que o monitoramento rotineiro seja realizado de acordo com a Tabela 13.2.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Tabela 13.2 Itens recomendados para monitoramento rotineiro&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;table&gt;&#xA;&#x9;&lt;thead&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Item&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Classe 100&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Classe 10 000&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Classe 100 000&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Classe 300 000&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;th&gt;Observações&lt;/th&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/thead&gt;&#xA;&#x9;&lt;tbody&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Concentração bacteriana&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Padrão de avaliação&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não exceder os requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não exceder os requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não exceder os requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não exceder os requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Em locais necessários ou pontos representativos&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Concentração bacteriana&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Frequência de medição Ar&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Monitoramento frequente ou uma vez por operação&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez a cada 1～2 dias&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/semana&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;vezes/mês&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Em locais necessários ou pontos representativos&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Concentração bacteriana&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Frequência de medição Superfície&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez por turno por dia, 3 amostras&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez por semana, 3 amostras&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez a cada 2 semanas, 3 amostras&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez por mês, 3 amostras&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Em locais necessários ou pontos representativos&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Concentração bacteriana&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Frequência de medição 5 dedos da luva&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1 pessoa/dia&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1 pessoa/1～2 dias&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;1 pessoa/semana&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Medido conforme o método padrão de desinfecção&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Diferença de pressão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Padrão de avaliação&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior ao limite inferior permitido e, preferencialmente, não superior a 30 Pa (exceto em salas limpas de biossegurança); se inferior ao limite inferior permitido, deve ser feito ajuste&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior ao limite inferior permitido e, preferencialmente, não superior a 30 Pa (exceto em salas limpas de biossegurança); se inferior ao limite inferior permitido, deve ser feito ajuste&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior ao limite inferior permitido e, preferencialmente, não superior a 30 Pa (exceto em salas limpas de biossegurança); se inferior ao limite inferior permitido, deve ser feito ajuste&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior ao limite inferior permitido e, preferencialmente, não superior a 30 Pa (exceto em salas limpas de biossegurança); se inferior ao limite inferior permitido, deve ser feito ajuste&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Medido pelo medidor de pressão diferencial na parede da entrada&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Diferença de pressão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Frequência de medição&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/dia&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/dia&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/semana&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/semana&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Medido pelo medidor de pressão diferencial na parede da entrada&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Volume de ar&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Padrão de avaliação&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior aos requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior aos requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior aos requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior aos requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Medido em dias de descanso ou durante revisão geral; para salas abaixo da Classe 100, converter a velocidade na saída de ar em taxa de renovação de ar; para salas Classe 100, trata-se da velocidade da seção transversal na zona de trabalho&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Volume de ar&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Frequência de medição&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/semestre&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/semestre&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/ano&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/ano&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Medido em dias de descanso ou durante revisão geral; para salas abaixo da Classe 100, converter a velocidade na saída de ar em taxa de renovação de ar; para salas Classe 100, trata-se da velocidade da seção transversal na zona de trabalho&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classe de limpeza&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Padrão de avaliação&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior aos requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior aos requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior aos requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Não inferior aos requisitos de gestão&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Com instrumentos; sem instrumentos, solicitar a uma instituição especializada que realize a medição&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classe de limpeza&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Frequência de medição&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Monitoramento frequente&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Monitoramento frequente&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Monitoramento frequente&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Monitoramento frequente&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Com instrumentos; sem instrumentos, solicitar a uma instituição especializada que realize a medição&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&#x9;&#x9;&lt;tr&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Classe de limpeza&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Frequência de medição&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/ano&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/ano&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/ano&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Uma vez/ano&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&#x9;&#x9;&lt;td&gt;Com instrumentos; sem instrumentos, solicitar a uma instituição especializada que realize a medição&lt;/td&gt;&#xA;&#x9;&#x9;&#x9;&lt;/tr&gt;&#xA;&#x9;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;h3 id=&#34;parte-dois&#34;&gt;Parte Dois&lt;/h3&gt;&#xA;&lt;h3 id=&#34;exemplos-de-engenharia&#34;&gt;Exemplos de Engenharia&lt;/h3&gt;</description>
			</item>
			<item>
				<title>Prevenção e Exaustão de Fumaça em Edifícios</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/smoke-prevention-exhaust/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/smoke-prevention-exhaust/</guid>
				<description>&lt;p&gt;Numerosos incêndios em edificações demonstraram que a fumaça tóxica de alta temperatura gerada em um incêndio se espalha rapidamente por diversos canais, tornando a fumaça no interior das edificações uma das principais causas de impedimento à fuga das pessoas e às operações de combate a incêndio, além de provocar óbitos. O projeto de prevenção de fumaça das edificações é muito importante para garantir a segurança das pessoas no interior da edificação e evitar a propagação da fumaça. A prevenção e a exaustão de fumaça da edificação devem ser consideradas como ponto-chave no projeto de segurança contra incêndio do departamento cirúrgico limpo de hospitais.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Temperatura</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/temperature/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/temperature/</guid>
				<description>&lt;p&gt;O controle de temperatura na sala de cirurgia é um meio eficaz de controlar a concentração bacteriana; ele faz parte das medidas de controle abrangentes e atua tanto no controle da reprodução de bactérias no ar quanto na contenção das bactérias eliminadas por pacientes e equipes médicas por meio da transpiração. Sua importância não se resume, de forma alguma, apenas ao conforto dos profissionais que se encontram no interior do ambiente. É evidente que a temperatura dentro da sala de cirurgia desempenha um papel no controle da reprodução bacteriana.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Temporizador para Salas Cirúrgicas</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/timer-operating-rooms/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/timer-operating-rooms/</guid>
				<description>&lt;p&gt;Com o aumento das exigências para uso em salas de operações, a cronometragem realizada por um único relógio convencional já não satisfaz os requisitos.&#xA;Os temporizadores configurados nas salas de operações modernas exibem o tempo por meio de dois conjuntos de dígitos de cores distintas: um conjunto para exibição do tempo cirúrgico e o outro para exibição do tempo de anestesia. O tempo pode ser apresentado tanto no formato de 24 horas quanto no de 12 horas; em caso de falha de energia, a fonte de alimentação incorporada assegura o funcionamento por não menos de 10 horas; também está incluído um relógio de marcação de tempo convencional. As dimensões globais do temporizador são 900mm×250mm×100mm = comprimento×altura×espessura, de montagem embutida; a altura de instalação é de 2m acima do piso, e existe um painel de controle separado à altura de operação, no qual são fornecidos dois conjuntos de botões, respectivamente. O temporizador deve ser instalado preferencialmente na parte superior da parede, onde não seja facilmente visível para o paciente.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Chapter 10. Sealing Systems and Door Interface Design</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/sealing-systems-and-door-interface-design/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/sealing-systems-and-door-interface-design/</guid>
				<description>&lt;p&gt;&lt;strong&gt;A sua sala limpa passa na contagem de partículas em repouso, mas depois falha no teste de pressão da sala: o diferencial de 10 Pa entre o corredor e a sala ISO 7 dissipa-se em segundos após o fecho da porta. A folha está bem — então para onde vai o ar?&lt;/strong&gt; Quase sempre através das quatro folgas do perímetro: topo, ombreiras, remate de encontro e, acima de tudo, a folga inferior junto ao pavimento. A vedação é um sistema de componentes e interfaces, não uma única junta.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Cirurgia Limpa do Hospital Chuiyangliu de Pequim</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/beijing-chuiyangliu-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/beijing-chuiyangliu-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O Hospital Chuiyangliu de Pequim é um hospital geral de Classe II, Grau A, localizado no Distrito de Chaoyang, Pequim. Nos últimos anos, com a construção contínua de comunidades residenciais nas áreas vizinhas, e sendo o Hospital Chuiyangliu o maior hospital geral da região, o volume de atendimentos ambulatoriais da instituição aumentou rapidamente; ao mesmo tempo, as cirurgias realizadas (como cirurgia cardíaca, artroplastia e procedimentos oftalmológicos) passaram a exigir requisitos de assepsia cada vez mais elevados. Diante desse cenário, alinhado às suas próprias necessidades de desenvolvimento, o hospital decidiu converter as salas de cirurgia originais em um departamento cirúrgico limpo, em conformidade com os requisitos das normas nacionais.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Evacuação Segura no Interior de Edifícios</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/safe-evacuation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/safe-evacuation/</guid>
				<description>&lt;p&gt;No bloco operatório limpo devem ser instalados iluminação de emergência para evacuação de incêndio e placas de sinalização de evacuação de segurança contra incêndio.&lt;/p&gt;&#xA;&lt;p&gt;Estudos sobre o comportamento humano em incêndios demonstram que, quando as pessoas se deparam com um foco de incêndio, elas entram em pânico extremo e perdem o controle de suas ações, desenvolvendo reações psicológicas como a atração pela luz, o seguimento da multidão, o pensamento habitual, o medo e o impulso de correr para espaços abertos. Como consequência, durante um incêndio — especialmente quando há grande acúmulo de fumaça e o fornecimento normal de energia é interrompido —, muitas vezes as pessoas não conseguem encontrar a rota de fuga correta, atrasando o tempo precioso de evacuação e causando vítimas. Mesmo os profissionais de resgate e combate a incêndios bem treinados têm dificuldade em localizar rapidamente as saídas de segurança e as rotas de evacuação em edifícios de estrutura relativamente complexa, caso não haja placas de sinalização luminosas claras e inequívocas para orientá-los. Essa condição é prejudicial tanto para o início rápido das operações de resgate quanto para a própria segurança dos socorristas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sala limpa</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/cleanroom/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/cleanroom/</guid>
				<description>&lt;p&gt;Uma sala limpa refere-se a um espaço disponível para a atividade humana no qual a limpeza do ar atinge uma classe de limpeza do ar especificada e que possui capacidade de controlar a poluição.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;[Referência]&lt;/strong&gt; Uma sala na qual a concentração de partículas suspensas no ar é controlada. Sua construção e uso devem reduzir a introdução, geração e retenção de partículas no ambiente interno, e outros parâmetros internos relevantes, como temperatura, umidade e pressão, são controlados conforme exigido.&lt;/p&gt;</description>
			</item>
			<item>
				<title>UK HTM 2025 Parte 4: Ventilação e Ar Condicionado de Edifícios de Saúde — Ensaios e Validação</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/uk-htm2025-healthcare-ventilation-testing-validation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/relevant-standards/uk-htm2025-healthcare-ventilation-testing-validation/</guid>
				<description>&lt;h2 id=&#34;2-visão-geral&#34;&gt;2 Visão Geral&lt;/h2&gt;&#xA;&lt;h3 id=&#34;pessoal-de-comissionamento&#34;&gt;Pessoal de Comissionamento&lt;/h3&gt;&#xA;&lt;p&gt;2.1 Nenhuma pessoa consegue dominar todas as técnicas de comissionamento; por isso, muitas vezes é formada uma equipe de comissionamento, cujo objetivo de trabalho é garantir que a instalação atenda aos requisitos normais de operação e segurança necessários.&lt;/p&gt;&#xA;&lt;p&gt;2.2 A grande quantidade de dados gerados durante o comissionamento se tornará material de referência valioso relacionado à instalação para o futuro; portanto, deve-se garantir, em princípio, que esses dados sejam reunidos na forma de um manual de comissionamento e, após a conclusão do contrato, entregues ao proprietário juntamente com os diagramas de instalação.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Umidade relativa</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/relative-humidity/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/relative-humidity/</guid>
				<description>&lt;p&gt;De acordo com pesquisas, com uma umidade relativa de 50%, as bactérias morrem após flutuarem por 10 min; com uma umidade relativa mais alta ou mais baixa, a maioria das bactérias continua viva mesmo após 24 h. Em temperaturas normais, o mofo pode se desenvolver quando $\varphi=60%$ ou mais, e quando $\varphi=80%$ ou mais, o mofo se desenvolve independentemente da temperatura, conforme mostrado nas Figuras 4.7 e 4.8. Sabe-se que as normas hospitalares japonesas relevantes exigem a manutenção da umidade relativa em 50%, enquanto a norma alemã estabelece que a umidade relativa em todo o bloco cirúrgico não deve exceder 65%. A edição de 1999 do Manual ASHRAE dos Estados Unidos exige uma umidade relativa entre 45% e 55%, enquanto a edição de 1991 estabelecia o intervalo de 50% a 60%, mesmo requisito das &amp;ldquo;Diretrizes para Construção e Equipamentos de Instalações Hospitalares e Médicas&amp;rdquo; publicadas pelo Instituto Americano de Arquitetos. No entanto, essa diretriz flexibiliza o requisito para a faixa de 45% a 60% para salas de cirurgia obstétrica e salas de cirurgia geral. Obviamente, o valor de 50% é o mais ideal. No entanto, considerando as condições técnicas nacionais, o &amp;ldquo;Código&amp;rdquo; estabelece que a umidade relativa das salas de cirurgia de Classe Ⅰ e Ⅱ fique na faixa de 40% a 60%, e flexibiliza esse intervalo para 35% a 60% no caso das salas de cirurgia de Classe Ⅲ e Ⅳ.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Visualizador de Filmes</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/film-viewer/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/film-viewer/</guid>
				<description>&lt;p&gt;Negatoscópios de raios X embutidos estão disponíveis em diversos tamanhos, que podem ser selecionados de acordo com a complexidade da cirurgia. Em geral, as cirurgias complexas frequentemente se encontram em alto&lt;/p&gt;&#xA;&lt;p&gt;Figura 6.15 Negatoscópio de raios X&#xA;realizadas em salas de operação de nível superior, e o negatoscópio selecionado também possui especificações de maior porte. No entanto, em salas de operação de nível inferior, deve-se selecionar pelo menos um negatoscópio do tipo triplo. Sua posição de instalação é preferencialmente na parede oposta ao cirurgião-chefe. A aparência do negatoscópio é apresentada na Figura 6.15.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário de medicamentos, armário de instrumentos e armário de anestesia</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/medicine-instrument-anesthesia-cabinets/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/medicine-instrument-anesthesia-cabinets/</guid>
				<description>&lt;p&gt;Os três armários são produtos embutidos de aço inoxidável, com chapa de espessura de 1 a 1,2 mm. Os armários podem ser equipados com ou sem portas (embora esta última opção seja desfavorável para a gestão); as portas podem ser do tipo de correr ou do tipo com dobradiças laterais (de batente). Nas portas de correr, os trilhos de guia não devem ter arestas vivas e devem também ser fáceis de limpar higienicamente. O ângulo de abertura das portas de batente deve atingir 180 graus. O material da porta pode ser vidro ou o mesmo material do corpo do armário. O armário de medicamentos e o armário de instrumentos devem ser embutidos na parede no lado dos pés do paciente, enquanto o armário de anestésicos deve ser embutido na parede no lado da cabeça do paciente.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Capítulo 11. Desenhos de Projeto, Especificações e Personalização</title>
				<link>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/design-drawings-specifications-customisation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/steel-medical-doors-guide/steel-medical-and-cleanroom-door-design/design-drawings-specifications-customisation/</guid>
				<description>&lt;p&gt;Um empreiteiro de uma obra de acabamento hospitalar encomenda 80 portas de aço com base na tabela de portas do arquiteto — e, três meses depois, descobre que 12 delas colidem com as molas aéreas que o engenheiro de MEP encaminhou acima dos batentes, e que as portas de sala limpa foram especificadas 50 mm mais estreitas do que a rota validada de transferência de equipamentos. Quase todas as disputas envolvendo pacotes de portas hospitalares têm origem não em produtos defeituosos, mas em informações de desenhos e especificações ausentes ou descoordenadas. Este capítulo explica como é um pacote de submissão de portas completo e construtível e como os requisitos específicos do projeto são fixados.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Salas Cirúrgicas Limpas do Hospital Beijing Anzhen</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/beijing-anzhen-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/beijing-anzhen-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O Hospital Anzhen de Pequim é um hospital geral de Classe III Grau A, com 47 departamentos de enfermagem clínica e 800 leitos. O departamento geral de cirurgia está localizado no 2º e 3º andares do edifício de internação. A sala de máquinas de ar-condicionado para o departamento cirúrgico do 2º andar fica no 1º andar, enquanto a sala de máquinas de ar-condicionado para o departamento cirúrgico do 3º andar fica no 4º andar. A área construída total dos andares do departamento cirúrgico é de aproximadamente 8.000 m². O 2º andar é composto por 10 salas operatórias e uma unidade de terapia intensiva de 200 m² com 15 leitos. Entre elas, há 1 sala operatória com proteção de chumbo Grau I, 1 sala operatória conversível de pressão positiva/negativa Grau III, 1 sala operatória com proteção de chumbo Grau III e 7 salas operatórias Grau III; o 3º andar é composto por 10 salas operatórias e uma unidade de terapia intensiva de 700 m² com 40 leitos. Entre elas, há 1 sala operatória com proteção de chumbo Grau I, 3 salas operatórias Grau I e 6 salas operatórias Grau III.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Outras Medidas de Proteção contra Incêndios</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/other-fire-protection-measures/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/other-fire-protection-measures/</guid>
				<description>&lt;p&gt;Em um bloco cirúrgico limpo, é necessário dispor de instalações de fornecimento de oxigênio destinadas ao atendimento dos pacientes para atender às necessidades cirúrgicas. Em blocos cirúrgicos de maior porte, o oxigênio geralmente é conduzido dos tanques de armazenamento central de oxigênio até as salas de operação por meio de tubulações. O oxigênio é um agente comburente e está classificado como artigo de risco de incêndio Classe B. Em caso de incêndio, o oxigênio intensifica o fogo. O método fundamental de extinção de incêndios de gás é cortar a fonte de fornecimento do gás.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sala Limpa Industrial e Sala Limpa Biológica</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/industrial-cleanroom-biological-cleanroom/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/industrial-cleanroom-biological-cleanroom/</guid>
				<description>&lt;p&gt;【Referência】 Em relação aos objetos que controlam, as salas limpas são divididas em duas categorias principais: salas limpas industriais e salas limpas biológicas.&lt;/p&gt;&#xA;&lt;p&gt;A sala limpa industrial tem como principal objetivo o controle da contaminação por partículas não biológicas, enquanto a sala limpa biológica tem como principal objetivo o controle da contaminação por partículas biológicas.&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 Uma sala limpa biológica refere-se a um espaço limpo no qual os microrganismos suspensos no ar são controlados dentro de valores especificados.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Volume mínimo de ar fresco</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/minimum-fresh-air-volume/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/minimum-fresh-air-volume/</guid>
				<description>&lt;p&gt;A vazão mínima de ar fresco de cada sala operatória deve ser determinada de acordo com os requisitos a seguir, devendo-se adotar o valor máximo.&lt;/p&gt;&#xA;&lt;p&gt;(1) A vazão de ar fresco calculada com base nas taxas de renovação de ar fresco da Tabela 4.1: quando calculada por pessoa por hora, a norma suíça estabelece 80 m³, a norma alemã, 60 m³, e a norma japonesa, de 3 a 5 vezes por hora. Esta tabela adota os valores de 60 m³ e de 3 a 6 vezes por hora.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Cirurgia Limpa do Hospital da Cidade de Jinjiang, Província de Fujian</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/jinjiang-city-hospital-fujian/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/jinjiang-city-hospital-fujian/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O Hospital Municipal de Jinjiang é um hospital geral de Classe II, Grau A, com 600 leitos. De acordo com as necessidades de seu próprio desenvolvimento, o hospital construiu um edifício de internação geral com 15 000 m². O edifício de internação tem 12 andares acima do solo e 1 andar subterrâneo. O bloco cirúrgico está localizado no 11º andar do novo edifício de internação, e a sala de máquinas de ar condicionado de purificação do bloco cirúrgico está localizada no sexto andar do edifício anexo. A área total de todo o bloco cirúrgico é de aproximadamente 1100 m². De acordo com as exigências do hospital, um bloco cirúrgico limpo abrangente deveria ser construído neste andar, incluindo 6 salas operatórias, salas auxiliares das salas operatórias e uma unidade de terapia intensiva pós-operatória (abreviada como enfermaria UTI) que pode acomodar 6 leitos. As 6 salas operatórias incluem 1 sala operatória Classe I, 2 salas operatórias Classe II, 2 salas operatórias Classe III e 1 sala operatória Classe IV para cirurgia geral.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Ruído</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/noise/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/noise/</guid>
				<description>&lt;p&gt;Embora o ruído não esteja relacionado à reprodução de bactérias em um ambiente controlado, uma sala operatória que funcionaria normalmente em outras circunstâncias não pode ser utilizada adequadamente se o ruído for muito alto. As fontes de ruído podem se propagar pelo ar ou por objetos sólidos, como paredes e painéis, e podem até percorrer uma grande distância através de suportes de dutos rigidamente conectados a equipamentos energizados. O projeto de controle de ruído não é, de forma alguma, algo que possa ser tornado infalível simplesmente pela instalação de alguns silenciadores. Os valores de ruído permitidos especificados na Norma levam em conta as condições nacionais da China e representam os valores máximos aceitáveis de ruído; em comparação com os valores permitidos no exterior, eles estão ligeiramente mais elevados. Se as condições permitirem, é aconselhável manter o ruído abaixo dos valores especificados na Norma. O valor de ruído permitido corresponde à média de todos os pontos de medição. Na Suíça, o valor é de 50 dB(A) para salas operatórias assépticas de alto padrão e de 45 dB(A) para salas operatórias assépticas, enquanto a norma alemã estabelece 45 dB(A) para ambos os casos.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sala limpa de fluxo unidirecional e sala limpa de fluxo turbulento</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/unidirectional-flow-cleanroom-turbulent-flow-cleanroom/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/unidirectional-flow-cleanroom-turbulent-flow-cleanroom/</guid>
				<description>&lt;p&gt;【Referência】 O padrão de fluxo de ar refere-se ao padrão de escoamento e à forma de distribuição do ar interno.&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 Conforme o fluxo de ar interno apresente um único padrão de escoamento ou padrões de escoamento coexistentes, as salas limpas podem ser divididas em quatro categorias:&lt;/p&gt;&#xA;&lt;p&gt;(1) Sala limpa com fluxo de ar unidirecional.&lt;/p&gt;&#xA;&lt;p&gt;(2) Sala limpa com fluxo de ar não unidirecional.&lt;/p&gt;&#xA;&lt;p&gt;(3) Sala limpa com fluxo de ar radial.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Trilha de Infusão</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/infusion-track/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/infusion-track/</guid>
				<description>&lt;p&gt;Os trilhos de infusão são fornecidos para o deslizamento das hastes de suspensão de frascos de infusão. Como os pacientes recebem infusão pelas mãos ou pelas pernas, deve ser instalado um trilho de infusão em cada lado diretamente acima da mesa cirúrgica, paralelo à mesa, com comprimento superior a 2,5 m, e o espaçamento entre os dois trilhos deve ser preferencialmente de 1,2 a 1,4 m.&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 Os trilhos de infusão são feitos de aço inoxidável ou alumínio e podem ser montados na superfície ou embutidos para instalação oculta, conforme mostrado na Figura 6.17. No entanto, como alguns usuários os consideram inconvenientes para a limpeza, alternativamente pode ser fornecido um anel de suspensão em cada um dos quatro cantos do plenum de insuflamento de ar para substituir os trilhos. Caso os trilhos sejam instalados, eles não devem obstruir a abertura dos acessórios no terminal de insuflamento de ar.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Bloco Operatório Limpo do Hospital de Doenças Renais de Kunming, Província de Yunnan</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/kunming-kidney-disease-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/kunming-kidney-disease-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O Hospital de Doenças Renais de Yunnan é uma instituição especializada em doenças renais que integra tratamento médico, pesquisa científica e prevenção, estabelecida com a aprovação do Departamento de Saúde da Província de Yunnan. Nos últimos anos, com a melhoria do padrão de vida da população, os requisitos para departamentos especializados tornaram-se cada vez mais elevados, e a sala de cirurgia hospitalar passou a ser o núcleo da instituição. Nesse contexto, o hospital decidiu construir um departamento cirúrgico limpo de alto padrão. As salas de cirurgia estão localizadas no 7º andar do edifício de enfermarias gerais; a sala de máquinas deste departamento cirúrgico limpo está posicionada no terraço acima do 7º andar, onde foi construída uma estrutura leve para sala de máquinas feita de painéis de aço colorido. A área construída de todo o andar do departamento cirúrgico é de aproximadamente 600 m². De acordo com os requisitos do hospital, esse andar deveria ser reformado para abrigar um departamento cirúrgico limpo completo, composto por 5 salas de cirurgia e suas salas auxiliares. As 5 salas de cirurgia incluem 1 sala de cirurgia Classe I, 1 sala de cirurgia Classe II e 3 salas de cirurgia Classe III.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Iluminância mínima</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/minimum-illuminance/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/technical-indicators/minimum-illuminance/</guid>
				<description>&lt;p&gt;Iluminância mínima refere-se à iluminação geral comum de toda a sala de cirurgia, não incluindo a iluminação local nem a iluminação do foco cirúrgico sem sombra. Tanto na China quanto no exterior, o tipo de iluminação por faixa de luz é amplamente adotado, e os níveis de iluminância também variam consideravelmente de país para país. Segundo a literatura estrangeira, a iluminância geral em salas de cirurgia fica em sua maioria acima de 500 lx, com a máxima chegando a 1.500 lx, e algumas fontes propõem 750–1.500 lx. No entanto, de acordo com medições de campo posteriores, a iluminância da sala de cirurgia asséptica da Universidade de Tokai, no Japão, era de 465 lx, a da sala de preparo, 350 lx, e a da antessala, 420 lx. Esses dados não foram explicitamente declarados como iluminância mínima, portanto provavelmente correspondem à iluminância média. Tendo em vista as condições nacionais da China, o Código adota, para a iluminação geral de salas de cirurgia, o valor do ponto mais baixo entre todos os pontos de medição na área de trabalho, ou seja, a iluminância mínima, fixada em 350 lx; a iluminância média então também ficará acima de 400 lx. Para ambientes que não sejam salas de cirurgia, adota-se 150 lx, de acordo com o padrão mínimo para salas limpas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Purificação de ar de toda a sala e purificação de ar local</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/whole-room-local-air-purification/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/whole-room-local-air-purification/</guid>
				<description>&lt;p&gt;Um método pelo qual, por meio de medidas técnicas como a limpeza do ar, a concentração de poeira do ar na área de trabalho interna atinge a classe de limpeza especificada.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Limpeza de ar local&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;Um método pelo qual a concentração de poeira do ar atinge a classe de limpeza especificada apenas dentro de um espaço local específico da área de trabalho interna.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Quadro de Recordes</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/record-board/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/record-board/</guid>
				<description>&lt;p&gt;O quadro de registros é do tipo embutido, rebatível para baixo ou de inserção deslizante. Um quadro de registros pequeno mede 500 mm de largura × 400 mm de altura × 300 mm de profundidade; quando as condições permitirem, o tamanho também pode ser aumentado. Quando fechado, o quadro de escrita deve ficar nivelado com a superfície da parede, e ele se rebate para baixo para uso; os fabricantes frequentemente o fornecem como produto padrão, como parte de um conjunto completo. A superfície aberta do quadro de escrita para uso sentado fica a 800 mm acima do piso, e a do quadro de escrita para uso em pé fica a 1.000 mm acima do piso.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Área de Trabalho Limpa e Zona Limpa Local</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/clean-work-area-local-clean-zone/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/clean-work-area-local-clean-zone/</guid>
				<description>&lt;p&gt;A área no interior de uma sala limpa a uma altura de 0,8 a 1,5 m acima do piso (exceto onde se aplicam requisitos especiais de processo).&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Zona limpa local&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;Uma área local dentro de uma sala na qual a concentração de poeira no ar atinge a classe de limpeza especificada.&lt;/p&gt;&#xA;&lt;p&gt;[Referência] Dependendo das necessidades do processo, a área limpa pode ser obtida em toda a sala ou de forma local. As áreas críticas de processo exigem a classe de limpeza mais alta e o controle mais rigoroso, mas a área a ser controlada geralmente não é grande; alcançar alta limpeza para toda a sala por esse motivo seria bastante irracional tanto em termos de custo de construção quanto de custo operacional.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento Cirúrgico Limpo do Primeiro Hospital da Cidade de Longyan, Província de Fujian</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/longyan-first-hospital-fujian/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/longyan-first-hospital-fujian/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O Primeiro Hospital da Cidade de Longyan é um grande hospital geral e o único hospital terciário da cidade de Longyan, província de Fujian. Possui 1000 leitos e um volume de atendimentos ambulatoriais diários muito elevado. Em conformidade com as necessidades do seu próprio desenvolvimento, o hospital construiu um edifício de enfermarias abrangente com 25 000 m². O edifício de enfermarias é composto por duas partes: o edifício principal e o edifício auxiliar. O edifício principal tem 15 andares, enquanto o edifício auxiliar, localizado no canto sudoeste do edifício principal, tem 3 andares; nos andares de 1 a 6, os edifícios principal e auxiliar estão interligados. O departamento cirúrgico está situado no quinto andar dos edifícios principal e auxiliar, e a sala de máquinas de ar condicionado limpo do departamento cirúrgico localiza-se no sexto andar do edifício auxiliar. A área construída total de todo o andar do departamento cirúrgico é de aproximadamente 1500 m². De acordo com os requisitos do hospital, pretendia-se construir neste andar um departamento cirúrgico limpo abrangente, composto por 8 salas de cirurgia, salas auxiliares das salas de cirurgia e uma unidade de terapia intensiva pós-operatória (doravante designada por enfermaria da UTI) com capacidade para 6 leitos. As 8 salas de cirurgia incluem 2 salas de cirurgia de Classe Ⅰ, 3 salas de cirurgia de Classe Ⅱ (uma das quais é uma sala de cirurgia ajustável de pressão positiva/negativa) e 3 salas de cirurgia de Classe Ⅲ.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Painel de Informações</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/information-panel/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/information-panel/</guid>
				<description>&lt;p&gt;No passado, muitos interruptores de energia eram instalados nas salas de cirurgia; interruptores de iluminação geral, interruptores de foco cirúrgico, telefones viva-voz, etc., eram todos instalados separadamente, o que era ao mesmo tempo desorganizado e difícil de localizar. Atualmente, isso evoluiu gradualmente para um controle multifuncional concentrado em um único painel de controle, com interruptores para, por exemplo, ar-condicionado, foco cirúrgico, alimentação da mesa cirúrgica, iluminação, negatoscópio, sistema de chamada, temporizador, terminal de rede, exibição e ajuste de temperatura e umidade, etc., tudo integrado. A Figura 6.19 mostra o painel de informações.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Armários de aquecimento, armários de refrigeração e congeladores</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/warming-cabinets-cooling-cabinets-freezers/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/clean-operating-room-equipment/warming-cabinets-cooling-cabinets-freezers/</guid>
				<description>&lt;p&gt;Os armários de aquecimento e os armários de refrigeração destinam-se a proporcionar conveniência em procedimentos cirúrgicos, permitindo que o soro fisiológico e os medicamentos utilizados durante a cirurgia sejam preparados antes da operação, de modo a garantir o uso conveniente durante o processo cirúrgico. Por exemplo, alguns medicamentos, materiais e órgãos a serem transplantados para o corpo do paciente requerem armazenamento a baixa temperatura, mas devem ser aquecidos de volta a uma temperatura semelhante à temperatura corporal do paciente quando utilizados; para encurtar o processo de transferência, este equipamento deve ser instalado na sala de cirurgia. No entanto, como o preço é relativamente elevado, não é necessário instalar uma unidade em cada sala de cirurgia. Para o armário de aquecimento, armário de refrigeração e armário de congelação, consulte a Figura 6.20.&#xA;Figura 6.19　Um exemplo de painel de informações&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Bloco Operatório Limpo do Edifício da Enfermaria Cirúrgica, Hospital Popular Provincial de Jiangsu</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/jiangsu-provincial-peoples-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/jiangsu-provincial-peoples-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;As salas de cirurgia limpas do edifício da enfermaria cirúrgica do Hospital Popular da Província de Jiangsu estão localizadas no terceiro andar, com área de piso de 2000 m² e pé-direito de 5 m. Há um total de 23 salas de cirurgia limpas (incluindo 12 salas de cirurgia à prova de radiação), das quais 4 são salas Classe I, 5 são Classe II e 14 são Classe III. Os corredores limpos e as salas funcionais auxiliares situadas ao longo deles são todos de Classe 100.000. O andar de equipamentos fica no pavimento acima das salas de cirurgia do terceiro andar, com pé-direito de 3,2 m.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sala Operatória Limpa e Departamento Operatório Limpo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/clean-operating-room-clean-operating-department/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/clean-operating-room-clean-operating-department/</guid>
				<description>&lt;p&gt;Uma sala de operações que adota determinadas medidas de purificação do ar e atinge níveis específicos de concentração bacteriana e classes de limpeza do ar.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Bloco Operatório Limpo&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;Uma área funcional autónoma composta por salas de operações limpas e salas auxiliares.&lt;/p&gt;&#xA;&lt;p&gt;[Referência] As pessoas esforçam-se por controlar o espaço asséptico das salas de operações, de forma a evitar eficazmente os danos causados por microrganismos e prevenir infeções pós-operatórias. A era em que o controlo asséptico era alcançado exclusivamente através de desinfeção química já passou; é plenamente reconhecido que a eficácia da desinfeção química é limitada e que esta é prejudicial para as pessoas e para o ambiente. Medidas de salvaguarda abrangentes centradas na tecnologia de limpeza biológica tornaram-se um meio eficaz e insubstituível para a sala de operações asséptica moderna. Neste sentido, o bloco operatório limpo é a sala de operações asséptica na aceção moderna.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Cirurgia Asséptica do Hospital da Vila de Shatou, Cidade de Nanhai</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/nanhai-shatou-town-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/nanhai-shatou-town-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O departamento de cirurgia limpa do Hospital da Vila de Shatou, Cidade de Nanhai, conta com um total de 4 salas de cirurgia limpas, incluindo 1 sala de cirurgia Classe I, 3 salas de cirurgia Classe III, além dos corredores limpos e salas auxiliares correspondentes.&lt;/p&gt;&#xA;&lt;h2 id=&#34;ii-layout-da-planta-baixa&#34;&gt;II. Layout da Planta Baixa&lt;/h2&gt;&#xA;&lt;p&gt;O Hospital da Vila de Shatou, na Cidade de Nanhai, é composto por 4 salas de cirurgia limpas e os respectivos corredores limpos e salas auxiliares. O layout interno da planta e a disposição dos corredores do departamento de cirurgia limpa seguem os princípios de fluxo funcional curto e direto, além de separação clara entre áreas limpas e sujas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sala de Purificação de Pessoal e Sala de Purificação de Materiais</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/personnel-material-purification-rooms/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/personnel-material-purification-rooms/</guid>
				<description>&lt;p&gt;Uma sala na qual o pessoal é limpo de acordo com um procedimento especificado antes de entrar na área limpa.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Sala para limpeza de materiais&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;Uma sala na qual os materiais são limpos de acordo com um procedimento especificado antes de entrar na área limpa.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Caixa de Passagem</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/pass-box/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/pass-box/</guid>
				<description>&lt;p&gt;Uma abertura feita na parede divisória de uma sala limpa para a transferência de materiais e ferramentas; há uma folha de janela em cada lado da abertura, interna e externa, e as duas folhas de janela não devem ser abertas ao mesmo tempo.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Operações Limpas do Edifício de Cirurgia de Emergência, Hospital Popular da Região Autônoma Uigur de Xinjiang</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/xinjiang-peoples-hospital-emergency-surgery/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/xinjiang-peoples-hospital-emergency-surgery/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;As salas de cirurgia limpas do Edifício de Cirurgia de Emergência da Região Autônoma Uigur de Xinjiang estão localizadas no 14º andar, com pé-direito de 4,8 m e um total de 20 salas. Entre elas, há 2 salas de cirurgia Classe I (1 sala com blindagem contra radiação), 8 salas de cirurgia Classe II (2 salas com blindagem contra radiação), 9 salas de cirurgia Classe III (1 sala com blindagem contra radiação e 2 salas com comutação de pressão positiva/negativa) e 1 sala de cirurgia contaminada Classe IV. Os corredores limpos e as salas funcionais auxiliares dentro dos corredores limpos são todos de Classe 100.000 (exceto a área de cirurgia contaminada). O 13º andar abriga o departamento de anestesiologia e salas auxiliares das salas de cirurgia, com pé-direito de 3,9 m. O andar de equipamentos está localizado acima do andar cirúrgico, com pé-direito de 2,2 m.&lt;/p&gt;</description>
			</item>
			<item>
				<title>CFU e VU</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/cfu-vu/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/cfu-vu/</guid>
				<description>&lt;p&gt;Uma ou mais partículas viáveis agregadas podem ser contadas como uma unidade. Quando várias VUs, conhecidas como colônias, se formam no meio de cultura, elas geralmente são representadas pela sigla UFC (CFU, na sigla em inglês).&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;【Referência】&lt;/strong&gt; Os microrganismos são organismos de estrutura simples, ampla distribuição, reprodução rápida e o menor tamanho individual. Os principais tipos de microrganismos são bactérias, fungos (incluindo mofos e leveduras), actinomicetos, espirilos, riquétsias, micoplasmas e vírus.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Cirurgia Limpa do Primeiro Hospital Popular da Cidade de Shunde</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/shunde-first-peoples-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/shunde-first-peoples-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O departamento de cirurgia limpa do Primeiro Hospital Popular de Shunde está localizado no sexto andar do Edifício 3; o andar de equipamentos situa-se acima do andar cirúrgico, que originalmente era um terraço ao ar livre, no qual posteriormente foi construída uma sala de máquinas com painéis sanduíche de aço colorido. O pé direito original do sexto andar era de 3,2 m, tendo sido elevado em 1 m posteriormente, passando para 4,2 m.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Concentração Bacteriana e Densidade Bacteriana de Superfície</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/bacterial-concentration-surface-bacterial-density/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/bacterial-concentration-surface-bacterial-density/</guid>
				<description>&lt;p&gt;&lt;strong&gt;【Referência】&lt;/strong&gt; Quando comparado à água e ao solo, o ar é um ambiente desfavorável para a sobrevivência de microrganismos. O ar carece de nutrientes; o ar seco, em particular, faz com que os microrganismos percam umidade, e os raios ultravioleta do sol também exercem efeito bactericida. Apenas em espaços fechados, como salas, fatores como a má ventilação interna e as atividades de seres humanos e outros organismos elevam a concentração microbiana do local, podendo surgir microrganismos patogênicos.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento do Bloco Operatório Limpo do Hospital Cardiovascular Internacional TEDA, Tianjin</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/teda-cardiovascular-hospital-tianjin/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/teda-cardiovascular-hospital-tianjin/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;O Hospital Cardiovascular Internacional TEDA é um hospital especializado em cardiologia recém-construído, equipado com 500 leitos de internação, 80 leitos de UTI, 40 leitos de CCU (Unidade de Cuidados Coronarianos), 6 aparelhos de angiografia cardiovascular e 16 salas cirúrgicas, com 10 mil cirurgias cardiovasculares e 10 mil tratamentos intervencionistas realizados anualmente.&lt;/p&gt;&#xA;&lt;p&gt;A área construída total é de $6,99\times10^4,\mathrm{m^2}$, com um pódio de 3 andares e um edifício principal de 12 andares em estrutura de pórticos e paredes de cisalhamento. As salas cirúrgicas limpas estão localizadas no segundo andar do pódio, entre os eixos 9-19/F-R, com área construída de 4307 m², composta por 16 salas cirúrgicas, juntamente com as salas funcionais e corredores correspondentes, incluindo 2 salas cirúrgicas Classe Ⅰ e 14 salas cirúrgicas Classe Ⅲ; a altura do piso do andar cirúrgico do segundo andar é de 4,8 m, e a entrada principal das salas cirúrgicas se conecta ao saguão principal dos elevadores; as salas de máquinas de ar-condicionado estão localizadas no terceiro andar, entre os eixos 9-19/G-M.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Centro Cirúrgico Limpo do Segundo Hospital Afiliado da Universidade Médica de Harbin</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/harbin-medical-university-second-affiliated-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/harbin-medical-university-second-affiliated-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;Área do bloco cirúrgico: 2900 m².&lt;/p&gt;&#xA;&lt;p&gt;Número de salas cirúrgicas: 24.&lt;/p&gt;&#xA;&lt;p&gt;Classificação de limpeza: 2 salas Classe Ⅰ, 22 salas Classe Ⅲ.&lt;/p&gt;&#xA;&lt;p&gt;Construções especiais: 2 salas cirúrgicas blindadas, 2 salas cirúrgicas para casos infecciosos.&lt;/p&gt;&#xA;&lt;h2 id=&#34;ii-layout-em-planta&#34;&gt;II. Layout em Planta&lt;/h2&gt;&#xA;&lt;p&gt;(1) Tipo de projeto: tipo de recuperação de resíduos (o corredor central é projetado como corredor limpo, e o corredor externo funciona como via de passagem de resíduos)&lt;/p&gt;</description>
			</item>
			<item>
				<title>Desinfecção</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/disinfection/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/disinfection/</guid>
				<description>&lt;p&gt;Refere-se ao uso de métodos físicos ou químicos para matar todos os microrganismos patogênicos em um objeto ou em um meio, sem necessariamente matar esporos. Por meio da desinfecção, a disseminação de microrganismos patogênicos pode ser prevenida.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Esterilização&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;Refere-se ao uso de métodos físicos e químicos para matar todos os microrganismos em um objeto ou em um meio, incluindo todos os microrganismos patogênicos e não patogênicos, bem como esporos bacterianos.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Operações de Limpeza do Hospital Central do Distrito de Jiading, Xangai</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/shanghai-jiading-central-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/shanghai-jiading-central-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;Área do centro cirúrgico: 2160 m².&lt;/p&gt;&#xA;&lt;p&gt;Número de salas de cirurgia: 10.&lt;/p&gt;&#xA;&lt;p&gt;Classificação de limpeza: 1 sala Classe Ⅰ, 2 salas Classe Ⅱ, 7 salas Classe Ⅲ.&lt;/p&gt;&#xA;&lt;p&gt;Outros: corredores limpos Classe Ⅳ e salas auxiliares.&lt;/p&gt;&#xA;&lt;h2 id=&#34;ii-layout-da-planta-baixa&#34;&gt;II. Layout da Planta Baixa&lt;/h2&gt;&#xA;&lt;p&gt;(1) Tipo de projeto. Modelo de recuperação de resíduos (o corredor central é projetado como corredor limpo, e o corredor externo funciona como passagem de resíduos).&lt;/p&gt;</description>
			</item>
			<item>
				<title>Tempo de Autopurificação</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/self-purification-time/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/self-purification-time/</guid>
				<description>&lt;p&gt;O tempo necessário para que uma sala limpa, após ser contaminada, recupere a classe de limpeza interna estável e especificada.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;[Referência]&lt;/strong&gt; Para uma sala limpa durante a operação do sistema de ar-condicionado de purificação, o tempo necessário para que a concentração de poeira do ambiente interno diminua de um valor relativamente alto para um valor estável é definido como tempo de autolimpeza (min). Ele está relacionado à taxa de renovação de ar interna e à distribuição de ar.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento do Bloco Operatório Limpo do Hospital Internacional da Paz de Maternidade e Saúde Materno-Infantil da Associação de Bem-Estar da China.</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/international-peace-maternity-child-health-hospital/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/international-peace-maternity-child-health-hospital/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;Área das salas operatórias: 3520 m².&lt;/p&gt;&#xA;&lt;p&gt;Número de salas operatórias: 13, sendo 7 salas operatórias de obstetrícia e 6 salas operatórias de planejamento familiar.&lt;/p&gt;&#xA;&lt;p&gt;Classificação de limpeza: 7 salas Classe Ⅲ e 6 salas Classe Ⅳ.&lt;/p&gt;&#xA;&lt;p&gt;Outros espaços: salas LDR e sala de suprimentos central.&lt;/p&gt;&#xA;&lt;h2 id=&#34;ii-layout-da-planta-baixa&#34;&gt;II. Layout da Planta Baixa&lt;/h2&gt;&#xA;&lt;p&gt;(1) Tipo de projeto. Modelo de recuperação de resíduos (o corredor central é projetado como corredor limpo, e o corredor externo funciona como corredor de resíduos).&lt;/p&gt;</description>
			</item>
			<item>
				<title>Zona de Operação e Zona Circundante</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/operating-zone-surrounding-zone/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/operating-zone-surrounding-zone/</guid>
				<description>&lt;p&gt;&lt;strong&gt;[Referência]&lt;/strong&gt; Uma vez que a Norma enfatiza a proteção especial das partes críticas da sala cirúrgica (a mesa cirúrgica e seus arredores), é necessário definir a zona operatória. A zona operatória de uma sala cirúrgica Classe Ⅰ corresponde à área que inclui a mesa cirúrgica, após extensão de 0,9 m para fora em cada um dos dois lados e de 0,4 m para fora em cada uma das duas extremidades; a zona operatória de uma sala cirúrgica Classe Ⅱ corresponde à área que inclui a mesa cirúrgica, após extensão de 0,6 m para fora em cada um dos dois lados e de 0,4 m para fora em cada uma das duas extremidades; e a zona operatória de uma sala cirúrgica Classe Ⅲ corresponde à área que se estende 0,4 m para fora em todos os quatro lados da mesa cirúrgica.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Cirurgia Limpa do Hospital Xinhua Afiliado à Segunda Universidade Médica de Xangai</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/xinhua-hospital-shanghai-second-medical-university/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/xinhua-hospital-shanghai-second-medical-university/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;Área do centro cirúrgico: 2290 m².&lt;/p&gt;&#xA;&lt;p&gt;Número de salas operatórias: 18.&lt;/p&gt;&#xA;&lt;p&gt;Classificação de limpeza: 3 salas Classe I, 8 salas Classe II, 7 salas Classe III.&lt;/p&gt;&#xA;&lt;p&gt;Construção especial: 4 salas operatórias blindadas.&lt;/p&gt;&#xA;&lt;h2 id=&#34;ii-layout-da-planta-baixa&#34;&gt;II. Layout da Planta Baixa&lt;/h2&gt;&#xA;&lt;p&gt;(1) Tipo de projeto. Tipo de recuperação de resíduos (o corredor central é projetado como corredor limpo, e o corredor externo funciona como corredor de resíduos).&lt;/p&gt;&#xA;&lt;p&gt;(2) O departamento cirúrgico ocupa dois andares.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Pressão de Gradiente Ordenada</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/ordered-gradient-pressure/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/ordered-gradient-pressure/</guid>
				<description>&lt;p&gt;&lt;strong&gt;[Referência]&lt;/strong&gt; Para evitar que o ar não limpo do exterior perturbe o estado limpo e asséptico do ambiente interno, o método mais eficaz é o controle de pressão positiva, ou seja, manter a pressão do ar interno superior à pressão externa, de forma que o ar interno só possa escoar para o exterior e não seja possível ocorrer fluxo reverso. Atualmente, com o desenvolvimento do controle, que passou do controle de salas individuais para o controle de áreas inteiras, é necessário estabelecer uma distribuição de pressão em gradiente ordenada entre o interior e o exterior da área, bem como entre espaços de diferentes classes de limpeza dentro da área.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Departamento de Cirurgia Limpa do Hospital Popular da Cidade de Rui’an, Província de Zhejiang</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/ruian-peoples-hospital-zhejiang/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/ruian-peoples-hospital-zhejiang/</guid>
				<description>&lt;h2 id=&#34;i-visão-geral-do-projeto&#34;&gt;I. Visão Geral do Projeto&lt;/h2&gt;&#xA;&lt;p&gt;Área do setor de salas operatórias: 1620 m².&lt;/p&gt;&#xA;&lt;p&gt;Número de salas operatórias: 12.&lt;/p&gt;&#xA;&lt;p&gt;Classificação de grau de limpeza: 2 salas Classe Ⅰ, 4 salas Classe Ⅱ e 6 salas Classe Ⅲ.&lt;/p&gt;&#xA;&lt;h2 id=&#34;ii-disposição-da-planta-baixa&#34;&gt;II. Disposição da Planta Baixa&lt;/h2&gt;&#xA;&lt;p&gt;(1) Tipo de projeto. Tipo de recolha de resíduos (o corredor central é projetado como corredor limpo, e o corredor externo funciona como passagem de resíduos).&lt;/p&gt;&#xA;&lt;p&gt;(2) As salas operatórias estão localizadas no segundo andar, o interpiso técnico situa-se entre o segundo e o terceiro andares, e parte das casas de máquinas de ar-condicionado encontra-se na camada técnica.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Eclusa de ar</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/airlock/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/airlock/</guid>
				<description>&lt;p&gt;Uma sala de amortecimento instalada na entrada e na saída de uma sala limpa, prevista para bloquear o fluxo de ar contaminado do exterior ou de salas adjacentes e para controlar a diferença de pressão.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;[Referência]&lt;/strong&gt; Uma eclusa de ar é um espaço vedado com duas portas, das quais apenas uma pode ser aberta de cada vez; sua finalidade é controlar o fluxo de ar entre as salas, como uma comporta de ar, quando as pessoas precisam entrar ou sair.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sala de Ducha de Ar</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/air-shower-room/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/air-shower-room/</guid>
				<description>&lt;p&gt;Um dispositivo que utiliza um fluxo de ar limpo de alta velocidade para soprar e remover as partículas aderidas às superfícies das roupas do pessoal que entra na sala limpa.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sala de Buffer</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/buffer-room/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/buffer-room/</guid>
				<description>&lt;p&gt;Uma sala pequena com área não inferior a $3\text{m}^2$, cujas portas de entrada e saída não devem ser abertas simultaneamente, que é abastecida com ar limpo e atinge a mesma classe de limpeza da área a ser acessada (mas não superior à Classe 1 000). Mais eficaz do que uma eclusa de ar.&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 Chuveiros de ar são comumente utilizados em salas limpas industriais, fábricas farmacêuticas e outros locais onde a contaminação por partículas de poeira é controlada; com base em testes e no uso real, sua eficácia não é ideal. Em geral, não são aplicáveis a salas limpas biológicas, nas quais o controle de microrganismos é a principal preocupação.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Equipamento Básico</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/basic-equipment/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/basic-equipment/</guid>
				<description>&lt;p&gt;【Referência】 O equipamento básico de uma sala operatória refere-se às instalações básicas relacionadas à disposição em planta e à instalação arquitetônica de salas operatórias limpas e salas operatórias, e não inclui instrumentos e equipamentos cirúrgicos móveis de uso exclusivo.&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 As instalações no interior da sala operatória, como focos cirúrgicos sem sombra, armários de instrumentos e unidades de abastecimento de gases. Estas estão relacionadas tanto à disposição em planta quanto ao projeto de fluxo de ar da sala operatória, sendo também um aspecto importante para garantir a padronização e a modernização das salas operatórias limpas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Água de alta pureza</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/high-purity-water/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/high-purity-water/</guid>
				<description>&lt;p&gt;Água pura com resistividade superior a $10\times10^6\ \Omega\cdot\text{cm}$ (temperatura de 25 ℃) e com requisitos rigorosos para partículas, bactérias, matéria orgânica, etc., na água.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Gás de Alta Pureza</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/high-purity-gas/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/high-purity-gas/</guid>
				<description>&lt;p&gt;Um gás com pureza maior ou igual a 99,9995% e teor de umidade inferior a 5 ppm.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Atenuação sonora</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/sound-attenuation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/sound-attenuation/</guid>
				<description>&lt;p&gt;Tecnologia que consiste em controlar, por determinados meios, o ruído gerado na produção ou em outros processos, de modo a reduzi-lo à faixa permitida.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Isolamento de Vibração</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/vibration-isolation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/vibration-isolation/</guid>
				<description>&lt;p&gt;Tecnologia que consiste em adotar certas medidas para atenuar a vibração transmitida por máquinas e equipamentos a um nível admissível, de modo a evitar danos às estruturas dos edifícios e efeitos adversos na produção e na saúde humana.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Estados Construído, Em Repouso e Operacional da Sala Limpa</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/cleanroom-states/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/cleanroom-states/</guid>
				<description>&lt;p&gt;&lt;strong&gt;Sala limpa em repouso (estado estático)&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Sala limpa em operação (estado dinâmico)&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;【Referência】 De acordo com o estado de utilização, as salas limpas podem ser divididas nas três categorias a seguir:&lt;/p&gt;&#xA;&lt;p&gt;(1) Uma sala limpa em estado construído, geralmente chamada de sala limpa em estado vazio, refere-se a uma sala limpa que foi concluída e está pronta para operação, com todas as instalações e funções relevantes, mas sem equipamentos ou pessoal dentro da sala limpa.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Aceitação</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/acceptance/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/terminology/acceptance/</guid>
				<description>&lt;p&gt;&lt;strong&gt;Teste&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;Uma atividade operacional de medição, por métodos especificados, do desempenho de uma instalação concluída ou de parte dela, com emissão de uma conclusão.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Monitoramento&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;Um processo operacional de realização de testes de rotina, que não sejam testes de aceitação, por meio de métodos e planos especificados, de modo a obter dados de desempenho de uma instalação como base para a supervisão de sua operação.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Aceitação de obra concluída&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;A inspeção e aprovação por parte do proprietário da qualidade de construção e instalação do bloco cirúrgico limpo, após o empreiteiro comissionar os parâmetros básicos do sistema de ar-condicionado limpo até atingir um nível qualificado.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Disposições obrigatórias relacionadas a este capítulo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/medical-gases/mandatory-provisions/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/medical-gases/mandatory-provisions/</guid>
				<description>&lt;p&gt;8.3.1　(1) As salas operatórias limpas devem garantir a fiabilidade do uso de eletricidade; quando for difícil adotar fontes de alimentação duplas, deve ser fornecida uma fonte de alimentação de reserva, capaz de efetuar a comutação automática em 1 min&lt;/p&gt;&#xA;&lt;p&gt;(2) A utilização de eletricidade nas salas operatórias limpas deve ser separada da das salas auxiliares, e a linha tronco de cada sala operatória deve ser assentada separadamente&lt;/p&gt;&#xA;&lt;p&gt;8.3.2　(4) É proibida a utilização de equipamentos de comunicação sem fio nas salas operatórias limpas&lt;/p&gt;</description>
			</item>
			<item>
				<title>Disposições Obrigatórias Relacionadas a Este Capítulo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/mandatory-provisions/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/fire-protection/mandatory-provisions/</guid>
				<description>&lt;p&gt;9.0.1　O departamento cirúrgico limpo deve estar localizado em uma edificação com grau de resistência ao fogo não inferior ao Grau II.&lt;/p&gt;&#xA;&lt;p&gt;9.0.2　O departamento cirúrgico limpo deve ser equipado com um dispositivo capaz de realizar o corte de emergência da tubulação principal do suprimento central de oxigênio.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Disposições Obrigatórias Relativas a Este Capítulo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/air-conditioning-system/mandatory-provisions/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/air-conditioning-system/mandatory-provisions/</guid>
				<description>&lt;p&gt;7.1.3　1　Devem ser previstos pelo menos três estágios de filtragem de ar&#xA;7.1.4　É estritamente proibido o uso de unidades fan coil convencionais ou de aparelhos de ar condicionado em salas limpas&#xA;7.1.9　4　A saída do duto de exaustão de ar não deve estar localizada no interior do mezanino técnico e deve ser direcionada diretamente para o exterior&#xA;7.3.7　Dispositivos eletrostáticos de purificação de ar não devem ser utilizados como instalação de purificação de estágio final do sistema de ar condicionado limpo&lt;/p&gt;</description>
			</item>
			<item>
				<title>Disposições Obrigatórias Relativas a Este Capítulo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/architecture/mandatory-provisions/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/architecture/mandatory-provisions/</guid>
				<description>&lt;p&gt;5.2.1　O departamento cirúrgico limpo deve ser dividido em uma área limpa e uma área não limpa. Deve ser fornecida uma sala de buffer ou uma janela de passagem entre a área limpa e a área não limpa.&lt;/p&gt;&#xA;&lt;p&gt;5.2.5　A disposição do plano do departamento cirúrgico limpo deve adotar fluxos de purificação eficazes, separadamente para o pessoal e para os artigos (curativos, instrumentos, etc.) (Figura 5.2.5, figura omitida aqui); os procedimentos de purificação devem ser organizados de forma contínua e não devem ser interrompidos pela área não limpa.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Disposições Obrigatórias Relativas a Este Capítulo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/mandatory-provisions/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/composition-and-grades/mandatory-provisions/</guid>
				<description>&lt;p&gt;3.0.3　Os indicadores dos padrões de classificação das salas operatórias limpas devem cumprir os requisitos da Tabela 3.0.3-1, e os indicadores dos padrões de classificação das principais salas auxiliares limpas devem cumprir os requisitos da Tabela 3.0.3-2 (tabelas omitidas; ver 3.0.3-1 e 3.0.3-2 do Código)&lt;/p&gt;</description>
			</item>
			<item>
				<title>Disposições Obrigatórias Relativas a Este Capítulo</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/power-distribution/mandatory-provisions/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/power-distribution/mandatory-provisions/</guid>
				<description>&lt;p&gt;8.3.1　1　O departamento cirúrgico limpo deve garantir a confiabilidade do fornecimento de energia. Quando for difícil adotar duas fontes de alimentação, deverá ser fornecida uma fonte de energia reserva, capaz de realizar comutação automática em até 1 min.&lt;/p&gt;&#xA;&lt;p&gt;　　　　2　O consumo de energia nas salas cirúrgicas limpas deve ser separado daquele das salas auxiliares, e a linha alimentadora principal de cada sala cirúrgica deve ser instalada separadamente.&lt;/p&gt;&#xA;&lt;p&gt;8.3.2　4　É proibido o uso de equipamentos de comunicação sem fio nas salas cirúrgicas limpas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Notas sobre os Exemplos de Engenharia</title>
				<link>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/explanation/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/docs/clean-operating-department-guide/engineering-examples/explanation/</guid>
				<description>&lt;p&gt;Esta coleção de exemplos de engenharia reúne desenhos selecionados dos centros cirúrgicos limpos de 21 hospitais de categorias representativas, abrangendo quatro tipos de desenhos: plantas baixas, diagramas de zoneamento e rotas de circulação, planta baixa de uma única sala cirúrgica e diagramas esquemáticos de sistemas de tratamento de ar. Cada um é acompanhado por descrições em quatro aspectos: &amp;ldquo;Visão Geral do Projeto&amp;rdquo;, &amp;ldquo;Layout&amp;rdquo;, &amp;ldquo;Sistema de Ar-Condicionado e Purificação&amp;rdquo; e &amp;ldquo;Distribuição de Ar Interior&amp;rdquo;. Estes projetos foram, em sua maior parte, concebidos ou concluídos após a implementação do &lt;em&gt;Código Técnico de Arquitetura para Centro Cirúrgico Limpo Hospitalar&lt;/em&gt;, e foram feitos esforços em todos eles para implementar o Código, razão pela qual têm valor de referência para os leitores em geral. No entanto, por várias razões — e especialmente porque o &lt;em&gt;Padrão de Construção para Centro Cirúrgico Limpo Hospitalar&lt;/em&gt; e o &lt;em&gt;Código Técnico de Arquitetura para Centro Cirúrgico Limpo Hospitalar&lt;/em&gt; não estão em vigor há muito tempo — esses projetos inevitavelmente ainda apresentam defeitos de um tipo ou de outro; não obstante, para facilitar a consulta dos leitores, estes desenhos são ainda apresentados aqui. Quando os leitores tiverem dominado os princípios estabelecidos na Parte Um, &amp;ldquo;Medidas Técnicas&amp;rdquo;, naturalmente poderão julgar por si mesmos. Ou seja, estes desenhos são apenas para referência, enquanto o Código é a base autoritativa.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta de chumbo automática e autofechante para blindagem radiológica médica</title>
				<link>https://pengchi.net/pt/medical-radiation-proof-swing-door/automatic-self-closing-medical-radiation-shielding-lead-door/</link>
				<pubDate>Wed, 14 Oct 2026 09:21:17 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-radiation-proof-swing-door/automatic-self-closing-medical-radiation-shielding-lead-door/</guid>
				<description>&lt;p&gt;A Porta de Chumbo Automática de Autofechamento para Blindagem de Radiação Médica foi projetada para instalações médicas que exigem acesso controlado e proteção contra radiação. Ela combina um sistema automático de operação da porta com uma estrutura de blindagem revestida de chumbo para ajudar a reduzir a transmissão de raios X através da entrada, quando devidamente especificada e instalada.&#xA;A porta pode ser personalizada de acordo com o layout da sala, os requisitos de proteção radiológica, as dimensões da abertura e as necessidades de controle de acesso. Sua função de fechamento automático ajuda a garantir que a entrada retorne à posição fechada após a passagem, apoiando os procedimentos de segurança radiológica em ambientes de imagiologia médica e diagnóstico.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Painel de Parede de Vidro Sala Limpa Centro Cirúrgico Modular</title>
				<link>https://pengchi.net/pt/operating-room-wall-panel/glass-wall-panel-cleanroom-modualr-operating-theater/</link>
				<pubDate>Tue, 13 Oct 2026 09:03:29 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-wall-panel/glass-wall-panel-cleanroom-modualr-operating-theater/</guid>
				<description>&lt;div class=&#34;wpb_text_column wpb_content_element &#34;&gt;&#xA;&lt;div class=&#34;wpb_wrapper&#34;&gt;&#xA;&lt;p&gt;Os sistemas de paredes de vidro são agora amplamente utilizados em salas de cirurgia, sendo resistentes à limpeza e desinfecção, bem como resistentes a ácidos e corrosão. Melhoram a estética arquitetônica, sem amassados, com superfície lisa para facilitar a limpeza. A impressão a jato de tinta colorida pode aliviar a pressão sobre o pessoal médico e eliminar o nervosismo do paciente, o que atende ao design humanizado. Além disso, todos os painéis de parede são encaixados na estrutura de suporte, o que permite uma instalação, desmontagem e intercâmbio flexíveis e rápidos, fáceis de trocar ou atualizar, e o processo de manutenção é simples e rápido.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Persianas de Grelha de Retorno de Ar de Alta Qualidade para Ventilação</title>
				<link>https://pengchi.net/pt/hvac-system/ventilation-high-quality-air-return-grille-louvers/</link>
				<pubDate>Tue, 13 Oct 2026 05:37:05 +0000</pubDate>
				<guid>https://pengchi.net/pt/hvac-system/ventilation-high-quality-air-return-grille-louvers/</guid>
				<description>&lt;h2 id=&#34;product-attrs-heading&#34; class=&#34;product-details-title&#34;&gt;Atributos do Produto&lt;/h2&gt;&#xA;&lt;div id=&#34;product-attrs-content&#34; class=&#34;product-attrs-scroll-area J-product-attrs-scroll-area&#34;&gt;&#xA;&lt;dl class=&#34;product-attrs-list J-product-attrs-list&#34;&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label&#34;&gt;Personalização&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value&#34;&gt;Disponível&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label&#34;&gt;Material&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value&#34;&gt;Aço Inoxidável&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label&#34;&gt;Utilização&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value&#34;&gt;Purificação Médica&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label&#34;&gt;Nº do Modelo&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value&#34;&gt;PC-JH-TFXT-001&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label&#34;&gt;Tipo&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value&#34;&gt;Saída Estilo Veneziano&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Camadas de Ar Estilo Veneziano&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;Simples&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Instalação&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;Entrada&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Certificação&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;CE, CCC&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Nome do Produto&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;Grelha de Ventilação Premium&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Materiais&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;Fibra de Vidro&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Função&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;Purificação&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Aplicação&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;Sala Limpa&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Grau de Filtragem&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;Filtro HEPA&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Embalagem de Transporte&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;Por Via Marítima&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Especificação&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;680*680*450&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Marca&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;Pengchi&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Origem&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;China&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Código HS&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;9406900020&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Capacidade de Produção&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;100000PCS/Ano&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Tamanho da Embalagem&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;60.00cm * 60.00cm * 25.00cm&lt;/dd&gt;&#xA; &#x9;&lt;dt class=&#34;product-attrs-label is-extra&#34;&gt;Peso Bruto da Embalagem&lt;/dt&gt;&#xA; &#x9;&lt;dd class=&#34;product-attrs-value is-extra&#34;&gt;0.800kg&lt;/dd&gt;&#xA;&lt;/dl&gt;&#xA;&lt;/div&gt;</description>
			</item>
			<item>
				<title>Armário Inteligente RFID &amp; Sapateira para Vestiário</title>
				<link>https://pengchi.net/pt/intelligent-medical-management-cabinet/rfid-intelligent-locker-shoe-cabinet-for-changing-room/</link>
				<pubDate>Tue, 13 Oct 2026 02:22:53 +0000</pubDate>
				<guid>https://pengchi.net/pt/intelligent-medical-management-cabinet/rfid-intelligent-locker-shoe-cabinet-for-changing-room/</guid>
				<description></description>
			</item>
			<item>
				<title>Carrinho de Mão de Aço Inoxidável de Camada Dupla</title>
				<link>https://pengchi.net/pt/medical-trolley/stainless-steel-double-layered-handcart/</link>
				<pubDate>Tue, 13 Oct 2026 01:07:25 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-trolley/stainless-steel-double-layered-handcart/</guid>
				<description></description>
			</item>
			<item>
				<title>Carrinho de Armazenamento Móvel Estéril em Aço Inoxidável com Rodízios</title>
				<link>https://pengchi.net/pt/medical-trolley/sterile-stainless-steel-mobile-storage-cart-with-casters/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:45 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-trolley/sterile-stainless-steel-mobile-storage-cart-with-casters/</guid>
				<description>&lt;p&gt;Nosso carrinho móvel de armazenamento em aço inoxidável é projetado profissionalmente para ambientes médicos higiênicos. Construído em aço inoxidável de alta qualidade (201 / 304 opcional), a superfície do carrinho é sem costuras, resistente à corrosão, fácil de limpar e desinfetar, atendendo aos requisitos de higiene hospitalar. Está equipado com rodízios silenciosos para serviços pesados, sendo 2 rodas giratórias com trava para posicionamento estável durante a operação.&lt;/p&gt;&#xA;&lt;h3&gt;Informações Principais&lt;/h3&gt;&#xA;&lt;ul&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Material&lt;/strong&gt;: Aço Inoxidável (201 ou 304 opcional)&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Local de Origem&lt;/strong&gt;: Dongguan, Guangdong, China&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Certificação&lt;/strong&gt;: ISO 13485&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Código HS&lt;/strong&gt;: 94029000&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Cenários de Aplicação&lt;/strong&gt;: Enfermarias hospitalares, salas de cirurgia, clínicas, laboratórios, casas de repouso, salas de suprimentos médicos. Para armazenamento, organização e transporte de instrumentos cirúrgicos, curativos e materiais médicos.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Porto de Embarque&lt;/strong&gt;: Porto de Shenzhen / Porto de Guangzhou&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Prazo de Entrega&lt;/strong&gt;: 15–25 dias úteis após o recebimento do depósito&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Capacidade de Produção&lt;/strong&gt;: 800 conjuntos por mês&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;Dimensões personalizadas, layouts de prateleiras e acessórios são suportados para atender a diferentes demandas de armazenamento. Cada unidade passa por rigorosa inspeção de qualidade antes do envio. Pedidos OEM e ODM são bem-vindos.</description>
			</item>
			<item>
				<title>Armário de metal com rodas e portas de vidro fumado</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/rolling-metal-storage-cabinet-with-smoked-glass-doors/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:44 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/rolling-metal-storage-cabinet-with-smoked-glass-doors/</guid>
				<description></description>
			</item>
			<item>
				<title>Armário de Plataforma em Aço Inoxidável com Portas Duplas</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-platform-cabinet-with-double-doors/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:44 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-platform-cabinet-with-double-doors/</guid>
				<description></description>
			</item>
			<item>
				<title>Mesa de Classificação e Embalagem Médica em Aço Inoxidável</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-medical-sorting-packing-table/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:43 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-medical-sorting-packing-table/</guid>
				<description>&lt;p&gt;&lt;strong&gt;Finalidade&lt;/strong&gt;: Classificar, inspecionar e embalar instrumentos médicos antes da esterilização.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Departamentos&lt;/strong&gt;: Departamento central de fornecimento de materiais estéreis (CSSD), sala de esterilização&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Tamanho&lt;/strong&gt;: Tamanhos padrão disponíveis, dimensões personalizadas OEM suportadas&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;Material&lt;/strong&gt;: Aço inoxidável 304&lt;/p&gt;</description>
			</item>
			<item>
				<title>Mesa de Instrumentos Médicos em Aço Inoxidável</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-medical-instrument-table/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:43 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-medical-instrument-table/</guid>
				<description>&lt;ul&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Finalidade&lt;/strong&gt;: Colocar e organizar instrumentos médicos para exame, tratamento e cirurgia.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Departamentos&lt;/strong&gt;: Sala de cirurgia, sala de tratamento, clínica, enfermaria&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Tamanho&lt;/strong&gt;: Tamanhos padrão disponíveis, dimensões personalizadas OEM suportadas&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Material&lt;/strong&gt;: Aço inoxidável&lt;/li&gt;&#xA;&lt;/ul&gt;</description>
			</item>
			<item>
				<title>Mesa de trabalho em aço inoxidável com quatro gavetas</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-worktable-with-four-drawers/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:42 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-worktable-with-four-drawers/</guid>
				<description>&lt;ul&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Departamentos&lt;/strong&gt;: Departamento central de esterilização (CSSD), sala de esterilização&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Tamanho&lt;/strong&gt;: Tamanhos padrão disponíveis, dimensões personalizadas OEM suportadas&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Material&lt;/strong&gt;: Aço inoxidável (201 / 304 opcional)&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Padrão&lt;/strong&gt;: ISO 13485&lt;/li&gt;&#xA;&lt;/ul&gt;</description>
			</item>
			<item>
				<title>Carrinho de Transferência de Resíduos Médicos em Aço Inoxidável com cesto azul</title>
				<link>https://pengchi.net/pt/medical-trolley/stainless-steel-medical-waste-transfer-trolley-with-blue-hamper/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:41 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-trolley/stainless-steel-medical-waste-transfer-trolley-with-blue-hamper/</guid>
				<description></description>
			</item>
			<item>
				<title>Carrinho de Curativo Médico em Aço Inoxidável com Gavetas</title>
				<link>https://pengchi.net/pt/medical-trolley/stainless-steel-medical-dressing-trolley-with-drawers/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:40 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-trolley/stainless-steel-medical-dressing-trolley-with-drawers/</guid>
				<description></description>
			</item>
			<item>
				<title>Carrinho de Resíduos para Higiene Matinal em Aço Inoxidável</title>
				<link>https://pengchi.net/pt/medical-trolley/stainless-steel-morning-care-waste-trolley/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:39 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-trolley/stainless-steel-morning-care-waste-trolley/</guid>
				<description>&lt;ul&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Finalidade&lt;/strong&gt;: Recolher e transferir roupas de cama sujas e resíduos gerados durante o cuidado matinal aos pacientes.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Departamentos&lt;/strong&gt;: Enfermarias hospitalares, unidades de enfermagem&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Tamanho&lt;/strong&gt;: Tamanhos padrão disponíveis, dimensões personalizadas OEM suportadas&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Material&lt;/strong&gt;: Aço inoxidável 304&lt;/li&gt;&#xA; &#x9;&lt;li&gt;&lt;strong&gt;Norma&lt;/strong&gt;: ISO 13485&lt;/li&gt;&#xA;&lt;/ul&gt;</description>
			</item>
			<item>
				<title>Carrinho Médico de Entrega de Medicamentos em Aço Inoxidável com duas gavetas</title>
				<link>https://pengchi.net/pt/medical-trolley/stainless-steel-medical-medicine-delivery-trolley-with-two-drawers/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:39 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-trolley/stainless-steel-medical-medicine-delivery-trolley-with-two-drawers/</guid>
				<description></description>
			</item>
			<item>
				<title>Carrinho de resgate médico em aço inoxidável com duas gavetas</title>
				<link>https://pengchi.net/pt/medical-trolley/stainless-steel-medical-rescue-trolley-with-two-drawers/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:38 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-trolley/stainless-steel-medical-rescue-trolley-with-two-drawers/</guid>
				<description></description>
			</item>
			<item>
				<title>Armário de Armazenamento em Aço sem Portas</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/doorless-steel-storage-cabinet/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:37 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/doorless-steel-storage-cabinet/</guid>
				<description></description>
			</item>
			<item>
				<title>Mesa de escritório em aço inoxidável com gaveteiro</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-office-desk-with-drawer-pedestal/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:36 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-office-desk-with-drawer-pedestal/</guid>
				<description></description>
			</item>
			<item>
				<title>Armário de plataforma combinado em aço inoxidável para tanque de lavagem de esgoto</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-combination-platform-cabinet-for-sewage-washing-tank/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:35 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-combination-platform-cabinet-for-sewage-washing-tank/</guid>
				<description>&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;ul&gt;&#xA; &#x9;&lt;li&gt;A: Design integrado que combina funções de lavagem, operação e armazenamento. Reduz a disposição dispersa dos equipamentos, otimiza o fluxo de trabalho e melhora a utilização do espaço.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;B: Construído em aço inoxidável 304 / 316, resistente a ácidos, álcalis, desinfetantes e outros produtos químicos.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;C: Soldagem completa nas juntas; as costuras de solda são polidas e escovadas para um acabamento uniforme.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;D: Bancada e armário de armazenamento integrados para maior comodidade.&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;&lt;h3&gt;Parâmetros Técnicos&lt;/h3&gt;&#xA;Modelo: Gabinete Combinado de Plataforma com Cuba em Aço Inoxidável&#xA;&lt;p&gt;Dimensão: Personalizada de acordo com as condições do local&lt;/p&gt;</description>
			</item>
			<item>
				<title>Pia Médica de Aço Inoxidável</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-medical-sink/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:35 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-medical-sink/</guid>
				<description>&lt;h1&gt;Características do Produto&lt;/h1&gt;&#xA;&lt;ul&gt;&#xA; &#x9;&lt;li&gt;A: Pias personalizadas de cuba simples, dupla e tripla disponíveis conforme os requisitos do cliente.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;B: Construído em aço inoxidável 304 / 316, resistente a ácidos, álcalis, desinfetantes e outros produtos químicos.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;C: Soldagem completa aplicada nas juntas; as costuras de solda são polidas e escovadas para um acabamento uniforme.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;D: Projetado para imersão e esfregação de instrumentos, recipientes, ferramentas e itens com formas complexas.&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;&lt;h1&gt;Parâmetros Técnicos&lt;/h1&gt;&#xA;Modelo | Dimensão Pia Médica de Cuba Simples | C600 × A900 × P600 mm Pia Médica de Cuba Dupla | C1200 × A900 × P600 mm Pia Médica de Cuba Tripla | C1800 × A900 × P600 mm&#xA;&lt;h1&gt;Materiais&lt;/h1&gt;&#xA;Estrutura principal: aço inoxidável 304 Bancada: aço inoxidável 304 ou 316 Cuba da pia: aço inoxidável 304 ou 316 Torneira: somente água fria / água quente e fria / torneira com sensor</description>
			</item>
			<item>
				<title>Armário de armazenamento em metal cinza fosco com portas duplas</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/matte-gray-metal-storage-cabinet-with-double-doors/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:34 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/matte-gray-metal-storage-cabinet-with-double-doors/</guid>
				<description></description>
			</item>
			<item>
				<title>Mesa Móvel de Recebimento em Aço Inoxidável</title>
				<link>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-mobile-receiving-table/</link>
				<pubDate>Mon, 12 Oct 2026 11:37:34 +0000</pubDate>
				<guid>https://pengchi.net/pt/products-for-sterile-supply-department/stainless-steel-mobile-receiving-table/</guid>
				<description></description>
			</item>
			<item>
				<title>Carrinho de transferência de mercadorias em aço inoxidável com gaveta</title>
				<link>https://pengchi.net/pt/medical-trolley/stainless-steel-goods-transfer-cart-with-drawer/</link>
				<pubDate>Mon, 12 Oct 2026 11:05:23 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-trolley/stainless-steel-goods-transfer-cart-with-drawer/</guid>
				<description></description>
			</item>
			<item>
				<title>Armário de Armazenamento Médico em Aço Inoxidável 304</title>
				<link>https://pengchi.net/pt/medical-cabinet/304-stainless-steel-medical-storage-cabinet/</link>
				<pubDate>Mon, 12 Oct 2026 06:33:15 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-cabinet/304-stainless-steel-medical-storage-cabinet/</guid>
				<description>&lt;p&gt;O Armário Médico de Armazenamento em Aço Inoxidável 304 é uma unidade de armazenamento independente projetada para ambientes médicos e de saúde. É construído em chapa de aço inoxidável com espessura de 1,0–1,5 mm, oferecendo boa resistência à corrosão, resistência estrutural e facilidade de limpeza.&lt;/p&gt;&#xA;&lt;p&gt;O armário possui estrutura em aço inoxidável, portas frontais de vidro transparente, puxadores metálicos e múltiplas prateleiras horizontais para armazenamento organizado. As portas de vidro permitem visualizar facilmente os itens armazenados, ajudando a protegê-los contra poeira e contaminação externa.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Solução Chave na Mão de Mobiliário de Laboratório</title>
				<link>https://pengchi.net/pt/laboratory-furniture-turnkey-solution/</link>
				<pubDate>Thu, 08 Oct 2026 10:14:52 +0000</pubDate>
				<guid>https://pengchi.net/pt/laboratory-furniture-turnkey-solution/</guid>
				<description>&lt;section class=&#34;position-relative text-white overflow-hidden&#34; &gt;&#xA;&lt;style&gt;.swiper-manager-container.swiper-style17.swiper-slide-name-labfurnituresolution {--height:auto ;--height-pad:auto!important;--gap:20px !important;--slides_per_view_pc:1.7 !important;--slides_per_view_pad:1 !important;--height-mobile:auto!important;--products-count:10;--height:auto!important;--swiper-slide-aspect-ratio:16/9!important;--swiper-slide-aspect-ratio-pad:16/9!important;--swiper-slide-aspect-ratio-mobile:16/9!important;}.swiper-manager-container.swiper-style17.swiper-slide-name-labfurnituresolution .slide-content {}@media (max-width: 1024px) {.swiper-manager-container.swiper-style17.swiper-slide-name-labfurnituresolution {--height:auto!important;}}@media (max-width: 768px) {.swiper-manager-container.swiper-style17.swiper-slide-name-labfurnituresolution {--height:auto!important;}}.swiper-manager-outer-section#swiper-slide-name-labfurnituresolution {background:#000;&lt;/style&gt;&lt;section class=&#34;swiper-manager-outer-section&#34; id=&#34;swiper-slide-name-labfurnituresolution&#34;&gt;&lt;div class=&#34;swiper-manager-container swiper-slide-name-labfurnituresolution swiper-slide-id- color-white content-align-default swiper-style17&#34; id=&#34;swiper-instance-1&#34; data-navigation=&#34;true&#34; data-pagination=&#34;false&#34; data-loop=&#34;true&#34; data-autoplay=&#34;false&#34; data-thumbs=&#34;false&#34; data-mute=&#34;true&#34; data-height=&#34;auto&#34; data-height-pad=&#34;auto&#34; data-height-mobile=&#34;auto&#34; data-style-id=&#34;17&#34; data-auto-height=&#34;true&#34; data-space-between=&#34;20&#34; data-slider-name=&#34;labfurnituresolution&#34; data-slides-per-view-pc=&#34;1.7&#34; data-slides-per-group-pc=&#34;&#34; data-slides-per-view-pad=&#34;1&#34; data-slides-per-group-pad=&#34;&#34; data-slides-per-view-mobile=&#34;1&#34; data-slides-per-group-mobile=&#34;&#34; data-centered-slides=&#34;1&#34; data-title-font-size=&#34;&#34; data-subtitle-font-size=&#34;&#34; data-description-font-size=&#34;&#34; data-link-font-size=&#34;&#34; data-google-fonts=&#34;&#34; data-content-box-max-width=&#34;&#34;&gt; &lt;div class=&#34;swiper main-swiper&#34; style=&#34;height:auto&#34;&gt; &lt;div class=&#34;swiper-wrapper&#34;&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;KHh1vSSHchY&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;script type=&#34;module&#34; src=&#34;https://cdn.jsdelivr.net/npm/@justinribeiro/lite-youtube@1/lite-youtube.js&#34;&gt;&lt;/script&gt;&lt;/div&gt;&lt;/div&gt;&lt;div id=&#34;laboratory-bench-sink&#34; class=&#34;swiper-slide&#34;&gt;&lt;div&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/10/laboratory-sink-workbench-cabinets-bright-yj93HuMH-1280x720-1.jpg&#34; loading=&#34;lazy&#34; alt=&#34;Bancada e Pia de Laboratório&#34; class=&#34;slide-background-img&#34; /&gt;&lt;/div&gt;&lt;div class=&#34;slide-overlay&#34;&gt;&lt;/div&gt;&lt;div class=&#34;slide-content&#34;&gt;&lt;div class=&#34;content-inner&#34;&gt;&lt;h2 class=&#34;slide-title&#34;&gt;Bancada e Pia de Laboratório&lt;/h2&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div id=&#34;laboratory-bench-cabinets&#34; class=&#34;swiper-slide&#34;&gt;&lt;div&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/10/bright-modern-laboratory-workbench-equipment-TffpHSxw-1280x720-1.jpg&#34; loading=&#34;lazy&#34; alt=&#34;Bancada e Armários de Laboratório&#34; class=&#34;slide-background-img&#34; /&gt;&lt;/div&gt;&lt;div class=&#34;slide-overlay&#34;&gt;&lt;/div&gt;&lt;div class=&#34;slide-content&#34;&gt;&lt;div class=&#34;content-inner&#34;&gt;&lt;h2 class=&#34;slide-title&#34;&gt;Bancada e Armários de Laboratório&lt;/h2&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&#34;swiper-info-btn&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-autoplay-btn&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-button-prev&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-button-next&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-scrollbar&#34;&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&#34;swiper-manager-outer-section-content-after&#34;&gt;&lt;/div&gt;&lt;/section&gt;&#xA;&lt;/section&gt;&lt;!-- INTRODUÇÃO DA SOLUÇÃO + BOTÕES DE PDF / CATÁLOGO DA SOLUÇÃO --&gt;&#xA;&lt;section class=&#34;py-5&#34;&gt;&#xA;&lt;div class=&#34;container&#34;&gt;&#xA;&lt;div class=&#34;row justify-content-start&#34;&gt;&#xA;&lt;div class=&#34;col-lg-10&#34;&gt;&#xA;&lt;span class=&#34;text-success text-uppercase small fw-semibold&#34;&gt;Visão Geral da Solução&lt;/span&gt;&#xA;&lt;h2 class=&#34;fw-bold lh-sm mt-2 mb-3&#34;&gt;Sistemas Completos de Mobiliário para um Laboratório em Funcionamento&lt;/h2&gt;&#xA;&lt;p class=&#34;text-body-secondary&#34;&gt;A Solução Turnkey de Mobiliário Laboratorial da Pengchi fornece tudo em torno do que um laboratório é construído — bancadas de laboratório em aço, capelas de exaustão, plataformas de balança totalmente em aço, armários de laboratório e prateleiras para reagentes — sob um único contrato. Em vez de adquirir bancadas, capelas e armazenamento separadamente, os laboratórios e proprietários de projetos recebem um pacote coordenado, fabricado segundo um único padrão de qualidade e instalado como um escopo sequenciado.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Solução Chave na Mão para Mobiliário Hospitalar Médico</title>
				<link>https://pengchi.net/pt/medical-hospital-furniture-turnkey-solution/</link>
				<pubDate>Thu, 08 Oct 2026 10:09:53 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-hospital-furniture-turnkey-solution/</guid>
				<description>&lt;section class=&#34;position-relative text-white overflow-hidden&#34; &gt;&#xA;&lt;style&gt;.swiper-manager-container.swiper-style17.swiper-slide-name-hospitalfurnituresolution {--height:auto ;--height-pad:auto!important;--gap:20px !important;--slides_per_view_pc:1.7 !important;--slides_per_view_pad:1 !important;--height-mobile:auto!important;--products-count:10;--height:auto!important;--swiper-slide-aspect-ratio:16/9!important;--swiper-slide-aspect-ratio-pad:16/9!important;--swiper-slide-aspect-ratio-mobile:16/9!important;}.swiper-manager-container.swiper-style17.swiper-slide-name-hospitalfurnituresolution .slide-content {}@media (max-width: 1024px) {.swiper-manager-container.swiper-style17.swiper-slide-name-hospitalfurnituresolution {--height:auto!important;}}@media (max-width: 768px) {.swiper-manager-container.swiper-style17.swiper-slide-name-hospitalfurnituresolution {--height:auto!important;}}.swiper-manager-outer-section#swiper-slide-name-hospitalfurnituresolution {background:#000;&lt;/style&gt;&lt;section class=&#34;swiper-manager-outer-section&#34; id=&#34;swiper-slide-name-hospitalfurnituresolution&#34;&gt;&lt;div class=&#34;swiper-manager-container swiper-slide-name-hospitalfurnituresolution swiper-slide-id- color-white content-align-default swiper-style17&#34; id=&#34;swiper-instance-7&#34; data-navigation=&#34;true&#34; data-pagination=&#34;false&#34; data-loop=&#34;true&#34; data-autoplay=&#34;false&#34; data-thumbs=&#34;false&#34; data-mute=&#34;true&#34; data-height=&#34;auto&#34; data-height-pad=&#34;auto&#34; data-height-mobile=&#34;auto&#34; data-style-id=&#34;17&#34; data-auto-height=&#34;true&#34; data-space-between=&#34;20&#34; data-slider-name=&#34;hospitalfurnituresolution&#34; data-slides-per-view-pc=&#34;1.7&#34; data-slides-per-group-pc=&#34;&#34; data-slides-per-view-pad=&#34;1&#34; data-slides-per-group-pad=&#34;&#34; data-slides-per-view-mobile=&#34;1&#34; data-slides-per-group-mobile=&#34;&#34; data-centered-slides=&#34;1&#34; data-title-font-size=&#34;&#34; data-subtitle-font-size=&#34;&#34; data-description-font-size=&#34;&#34; data-link-font-size=&#34;&#34; data-google-fonts=&#34;&#34; data-content-box-max-width=&#34;&#34;&gt; &lt;div class=&#34;swiper main-swiper&#34; style=&#34;height:auto&#34;&gt; &lt;div class=&#34;swiper-wrapper&#34;&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;OKXU1WiiclQ&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;script type=&#34;module&#34; src=&#34;https://cdn.jsdelivr.net/npm/@justinribeiro/lite-youtube@1/lite-youtube.js&#34;&gt;&lt;/script&gt;&lt;/div&gt;&lt;/div&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/10/medical-cabinets-with-nurse.jpg&#34; loading=&#34;lazy&#34; alt=&#34;Armários de sala de tratamento médico&#34; class=&#34;slide-background-img&#34; /&gt;&lt;/div&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;cEvrObGkIFM&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;/div&gt;&lt;/div&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide&#34;&gt;&lt;div&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/10/nurse-hospital-triage-desk-flowchart-kewAj8NH-1280x720-1.jpg&#34; loading=&#34;lazy&#34; alt=&#34;estação de enfermagem&#34; class=&#34;slide-background-img&#34; /&gt;&lt;/div&gt;&lt;/div&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/10/stainless-medical-carts-clinical-showroom-7QkP4hnQ-1280x720-1.jpg&#34; loading=&#34;lazy&#34; alt=&#34;&#34; class=&#34;slide-background-img&#34; /&gt;&lt;/div&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;hcsPlunfKLg&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&#34;swiper-info-btn&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-autoplay-btn&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-button-prev&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-button-next&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-scrollbar&#34;&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&#34;swiper-manager-outer-section-content-after&#34;&gt;&lt;/div&gt;&lt;/section&gt;&#xA;&lt;/section&gt;&lt;!-- INTRODUÇÃO DA SOLUÇÃO + BOTÕES DE PDF / CATÁLOGO DA SOLUÇÃO --&gt;&#xA;&lt;section class=&#34;py-5&#34;&gt;&#xA;&lt;div class=&#34;container&#34;&gt;&#xA;&lt;div class=&#34;row justify-content-start&#34;&gt;&#xA;&lt;div class=&#34;col-lg-10&#34;&gt;&#xA;&lt;span class=&#34;text-success text-uppercase small fw-semibold&#34;&gt;Visão Geral da Solução&lt;/span&gt;&#xA;&lt;h2 class=&#34;fw-bold lh-sm mt-2 mb-3&#34;&gt;Mobiliário Que Organiza o Trabalho Diário de Todo o Hospital&lt;/h2&gt;&#xA;&lt;p class=&#34;text-body-secondary&#34;&gt;A Solução Turnkey de Mobiliário Hospitalar Médico da Pengchi fornece os sistemas de mobiliário que um hospital utiliza todos os dias — postos de enfermagem, balcões de receção do átrio, armários médicos, armários de gestão inteligente, lavatórios cirúrgicos para lavagem das mãos e mobiliário CSSD em aço inoxidável — sob um único contrato. Em vez de adquirir secretárias, armários e lavatórios de fornecedores separados com diferentes normas e prazos, os proprietários dos projetos recebem um pacote coordenado, fabricado segundo um único sistema de qualidade e instalado como um âmbito sequenciado.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Solução de Porta Metálica Médica</title>
				<link>https://pengchi.net/pt/metal-medical-door-solution/</link>
				<pubDate>Thu, 08 Oct 2026 09:59:55 +0000</pubDate>
				<guid>https://pengchi.net/pt/metal-medical-door-solution/</guid>
				<description>&lt;section &gt;&#xA;&lt;style&gt;.swiper-manager-container.swiper-style17.swiper-slide-name-medicaldoorsolution {--height:auto ;--height-pad:auto!important;--gap:20px !important;--slides_per_view_pc:1.7 !important;--slides_per_view_pad:1 !important;--height-mobile:auto!important;--products-count:10;--height:auto!important;--swiper-slide-aspect-ratio:16/9!important;--swiper-slide-aspect-ratio-pad:16/9!important;--swiper-slide-aspect-ratio-mobile:16/9!important;}.swiper-manager-container.swiper-style17.swiper-slide-name-medicaldoorsolution .slide-content {}@media (max-width: 1024px) {.swiper-manager-container.swiper-style17.swiper-slide-name-medicaldoorsolution {--height:auto!important;}}@media (max-width: 768px) {.swiper-manager-container.swiper-style17.swiper-slide-name-medicaldoorsolution {--height:auto!important;}}.swiper-manager-outer-section#swiper-slide-name-medicaldoorsolution {background:#000;&lt;/style&gt;&lt;section class=&#34;swiper-manager-outer-section&#34; id=&#34;swiper-slide-name-medicaldoorsolution&#34;&gt;&lt;div class=&#34;swiper-manager-container swiper-slide-name-medicaldoorsolution swiper-slide-id- color-white content-align-default swiper-style17&#34; id=&#34;swiper-instance-14&#34; data-navigation=&#34;true&#34; data-pagination=&#34;false&#34; data-loop=&#34;true&#34; data-autoplay=&#34;false&#34; data-thumbs=&#34;false&#34; data-mute=&#34;true&#34; data-height=&#34;auto&#34; data-height-pad=&#34;auto&#34; data-height-mobile=&#34;auto&#34; data-style-id=&#34;17&#34; data-auto-height=&#34;true&#34; data-space-between=&#34;20&#34; data-slider-name=&#34;medicaldoorsolution&#34; data-slides-per-view-pc=&#34;1.7&#34; data-slides-per-group-pc=&#34;&#34; data-slides-per-view-pad=&#34;1&#34; data-slides-per-group-pad=&#34;&#34; data-slides-per-view-mobile=&#34;1&#34; data-slides-per-group-mobile=&#34;&#34; data-centered-slides=&#34;1&#34; data-title-font-size=&#34;&#34; data-subtitle-font-size=&#34;&#34; data-description-font-size=&#34;&#34; data-link-font-size=&#34;&#34; data-google-fonts=&#34;&#34; data-content-box-max-width=&#34;&#34;&gt; &lt;div class=&#34;swiper main-swiper&#34; style=&#34;height:auto&#34;&gt; &lt;div class=&#34;swiper-wrapper&#34;&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;oj-uLRXaEZ0&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;script type=&#34;module&#34; src=&#34;https://cdn.jsdelivr.net/npm/@justinribeiro/lite-youtube@1/lite-youtube.js&#34;&gt;&lt;/script&gt;&lt;/div&gt;&lt;/div&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;vM1Wwfh3UjY&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;/div&gt;&lt;/div&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;IVJm58p2EZ0&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&#34;swiper-info-btn&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-autoplay-btn&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-button-prev&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-button-next&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-scrollbar&#34;&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&#34;swiper-manager-outer-section-content-after&#34;&gt;&lt;/div&gt;&lt;/section&gt;&#xA;&lt;/section&gt;&lt;!-- INTRODUÇÃO DA SOLUÇÃO + BOTÕES DE VR / CATÁLOGO --&gt;&#xA;&lt;section class=&#34;py-5&#34;&gt;&#xA;&lt;div class=&#34;container&#34;&gt;&#xA;&lt;div class=&#34;row justify-content-start&#34;&gt;&#xA;&lt;div class=&#34;col-lg-10&#34;&gt;&#xA;&lt;span class=&#34;text-success text-uppercase small fw-semibold&#34;&gt;Visão Geral da Solução&lt;/span&gt;&#xA;&lt;h2 class=&#34;fw-bold lh-sm mt-2 mb-3&#34;&gt;Todas as Portas do Hospital, Projetadas e Fornecidas por um Único Fabricante&lt;/h2&gt;&#xA;&lt;p class=&#34;text-body-secondary&#34;&gt;A Solução de Portas Médicas Metálicas da Pengchi oferece um programa completo de portas para hospitais, clínicas e edifícios laboratoriais sob um único contrato: portas de correr médicas automáticas, portas dobráveis automáticas, portas para salas limpas, portas médicas manuais de aço, portas de batente à prova de radiação e portas de segurança de aço. Em vez de adquirir cada tipo de porta de um fornecedor diferente, os proprietários do projeto recebem um cronograma coordenado, um único padrão de fabricação e um fornecedor responsável, desde o primeiro desenho da porta até o comissionamento final.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Solução Turnkey de Salas de Operação Modulares</title>
				<link>https://pengchi.net/pt/modular-operating-rooms-turnkey-solution/</link>
				<pubDate>Thu, 08 Oct 2026 08:55:44 +0000</pubDate>
				<guid>https://pengchi.net/pt/modular-operating-rooms-turnkey-solution/</guid>
				<description>&lt;section &gt;&#xA;&lt;style&gt;.swiper-manager-container.swiper-style17.swiper-slide-name-operatingroomsolution {--height:auto ;--height-pad:auto!important;--gap:20px !important;--slides_per_view_pc:1.7 !important;--slides_per_view_pad:1 !important;--height-mobile:auto!important;--products-count:10;--height:auto!important;--swiper-slide-aspect-ratio:16/9!important;--swiper-slide-aspect-ratio-pad:16/9!important;--swiper-slide-aspect-ratio-mobile:16/9!important;}.swiper-manager-container.swiper-style17.swiper-slide-name-operatingroomsolution .slide-content {}@media (max-width: 1024px) {.swiper-manager-container.swiper-style17.swiper-slide-name-operatingroomsolution {--height:auto!important;}}@media (max-width: 768px) {.swiper-manager-container.swiper-style17.swiper-slide-name-operatingroomsolution {--height:auto!important;}}.swiper-manager-outer-section#swiper-slide-name-operatingroomsolution {background:#000;&lt;/style&gt;&lt;section class=&#34;swiper-manager-outer-section&#34; id=&#34;swiper-slide-name-operatingroomsolution&#34;&gt;&lt;div class=&#34;swiper-manager-container swiper-slide-name-operatingroomsolution swiper-slide-id- color-white content-align-default swiper-style17&#34; id=&#34;swiper-instance-21&#34; data-navigation=&#34;true&#34; data-pagination=&#34;false&#34; data-loop=&#34;true&#34; data-autoplay=&#34;false&#34; data-thumbs=&#34;false&#34; data-mute=&#34;true&#34; data-height=&#34;auto&#34; data-height-pad=&#34;auto&#34; data-height-mobile=&#34;auto&#34; data-style-id=&#34;17&#34; data-auto-height=&#34;true&#34; data-space-between=&#34;20&#34; data-slider-name=&#34;operatingroomsolution&#34; data-slides-per-view-pc=&#34;1.7&#34; data-slides-per-group-pc=&#34;&#34; data-slides-per-view-pad=&#34;1&#34; data-slides-per-group-pad=&#34;&#34; data-slides-per-view-mobile=&#34;1&#34; data-slides-per-group-mobile=&#34;&#34; data-centered-slides=&#34;1&#34; data-title-font-size=&#34;&#34; data-subtitle-font-size=&#34;&#34; data-description-font-size=&#34;&#34; data-link-font-size=&#34;&#34; data-google-fonts=&#34;&#34; data-content-box-max-width=&#34;&#34;&gt; &lt;div class=&#34;swiper main-swiper&#34; style=&#34;height:auto&#34;&gt; &lt;div class=&#34;swiper-wrapper&#34;&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;0HNem0HbCvw&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;script type=&#34;module&#34; src=&#34;https://cdn.jsdelivr.net/npm/@justinribeiro/lite-youtube@1/lite-youtube.js&#34;&gt;&lt;/script&gt;&lt;/div&gt;&lt;/div&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;iDniASs9Sqc&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;/div&gt;&lt;/div&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;YJ5o-C0x47Y&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&#34;swiper-info-btn&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-autoplay-btn&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-button-prev&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-button-next&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-scrollbar&#34;&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&#34;swiper-manager-outer-section-content-after&#34;&gt;&lt;/div&gt;&lt;/section&gt;&#xA;&lt;/section&gt;&lt;!-- ==================== SOLUTION INTRODUCTION + VR / CATALOGUE BUTTONS ==================== --&gt;&#xA;&lt;section class=&#34;py-5&#34;&gt;&#xA;&lt;div class=&#34;container&#34;&gt;&#xA;&lt;div class=&#34;row justify-content-start&#34;&gt;&#xA;&lt;div class=&#34;col-lg-10&#34;&gt;&#xA;&lt;span class=&#34;text-success text-uppercase small fw-semibold&#34;&gt;Visão Geral da Solução&lt;/span&gt;&#xA;&lt;h2 class=&#34;fw-bold lh-sm mt-2 mb-3&#34;&gt;Uma Ala Cirúrgica Completa Entregue por um Único Fabricante Responsável&lt;/h2&gt;&#xA;&lt;p class=&#34;text-body-secondary&#34;&gt;A Solução Turnkey de Salas de Cirurgia Modulares da Pengchi oferece uma ala cirúrgica completa e pré-fabricada em fábrica — revestimento de paredes e teto, teto de fluxo de ar laminar, sistema de climatização HVAC, armários embutidos e unidade de controle integrada — sob um único contrato. Em vez de coordenar vários empreiteiros no local, os proprietários de hospitais trabalham com um único fabricante, responsável desde o primeiro desenho do layout até a entrega validada.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Demonstração em RV da Sala de Cirurgia</title>
				<link>https://pengchi.net/pt/vr-show-of-operating-room/</link>
				<pubDate>Thu, 08 Oct 2026 07:24:57 +0000</pubDate>
				<guid>https://pengchi.net/pt/vr-show-of-operating-room/</guid>
				<description>&lt;style id=&#34;pfvr-styles&#34;&gt;/**&#xA;* Estilos de front-end para visualizadores do PlayForge VR.&#xA;*&#xA;* O visualizador é uma sobreposição escura, em estilo de vidro, sobre o canvas do A-Frame.&#xA;* A própria sobreposição é transparente a cliques; os elementos interativos da interface&#xA;* reativam os eventos de ponteiro via .pfvr-ui / pointer-events dos botões.&#xA;*/&#xA;.pfvr-viewer {&#xA;position: relative;&#xA;width: 100%;&#xA;height: var(--pfvr-height, 100vh);&#xA;background: #05070a;&#xA;border-radius: 10px;&#xA;overflow: hidden;&#xA;outline: none;&#xA;font-family: -apple-system, BlinkMacSystemFont, &#34;Segoe UI&#34;, Roboto,&#xA;&#34;PingFang SC&#34;, &#34;Hiragino Sans GB&#34;, &#34;Microsoft YaHei&#34;, sans-serif;&#xA;color: #fff;&#xA;}&#xA;.pfvr-viewer:focus-visible {&#xA;box-shadow: 0 0 0 3px rgba(66, 165, 245, 0.55);&#xA;}&#xA;/* O A-Frame preenche o contêiner (o modo embedded remove seu min-height padrão). */&#xA;.pfvr-viewer .a-embedded,&#xA;.pfvr-viewer a-scene {&#xA;position: absolute;&#xA;inset: 0;&#xA;width: 100% !important;&#xA;height: 100% !important;&#xA;min-height: 0 !important;&#xA;}&#xA;/* Sobreposição: transparente a cliques por padrão, para que arrastar permita olhar ao redor. */&#xA;.pfvr-overlay {&#xA;position: absolute;&#xA;inset: 0;&#xA;z-index: 10;&#xA;pointer-events: none;&#xA;}&#xA;.pfvr-ui,&#xA;.pfvr-overlay button,&#xA;.pfvr-overlay select {&#xA;pointer-events: auto;&#xA;}&#xA;/* ---------- Barra superior ---------- */&#xA;.pfvr-topbar {&#xA;position: absolute;&#xA;top: 0;&#xA;left: 0;&#xA;right: 0;&#xA;display: flex;&#xA;align-items: center;&#xA;gap: 10px;&#xA;padding: 10px 14px;&#xA;background: linear-gradient(to bottom, rgba(0, 0, 0, 0.55), rgba(0, 0, 0, 0));&#xA;}&#xA;.pfvr-select {&#xA;flex: 1;&#xA;min-width: 0;&#xA;max-width: 360px;&#xA;padding: 7px 10px;&#xA;font-size: 13px;&#xA;color: #fff;&#xA;background: rgba(20, 26, 34, 0.72);&#xA;border: 1px solid rgba(255, 255, 255, 0.18);&#xA;border-radius: 8px;&#xA;cursor: pointer;&#xA;appearance: none;&#xA;-webkit-appearance: none;&#xA;background-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; width=&#39;12&#39; height=&#39;12&#39; viewBox=&#39;0 0 24 24&#39; fill=&#39;%23ffffff&#39;%3E%3Cpath d=&#39;M7 10l5 5 5-5z&#39;/%3E%3C/svg%3E&#34;);&#xA;background-repeat: no-repeat;&#xA;background-position: right 10px center;&#xA;padding-right: 30px;&#xA;}&#xA;.pfvr-select option {&#xA;color: #111;&#xA;}&#xA;.pfvr-top-actions {&#xA;margin-left: auto;&#xA;display: flex;&#xA;gap: 8px;&#xA;}&#xA;/* ---------- Botões ---------- */&#xA;.pfvr-btn {&#xA;display: inline-flex;&#xA;align-items: center;&#xA;justify-content: center;&#xA;width: 38px;&#xA;height: 38px;&#xA;padding: 0;&#xA;border: 1px solid rgba(255, 255, 255, 0.2);&#xA;border-radius: 50%;&#xA;background: rgba(20, 26, 34, 0.66);&#xA;color: #fff;&#xA;cursor: pointer;&#xA;backdrop-filter: blur(6px);&#xA;-webkit-backdrop-filter: blur(6px);&#xA;transition: background 0.15s ease, transform 0.15s ease;&#xA;}&#xA;.pfvr-btn:hover {&#xA;background: rgba(48, 60, 75, 0.9);&#xA;}&#xA;.pfvr-btn:active {&#xA;transform: scale(0.94);&#xA;}&#xA;.pfvr-nav {&#xA;position: absolute;&#xA;top: 50%;&#xA;transform: translateY(-50%);&#xA;z-index: 12;&#xA;}&#xA;.pfvr-nav:active {&#xA;transform: translateY(-50%) scale(0.94);&#xA;}&#xA;.pfvr-nav-prev { left: 14px; }&#xA;.pfvr-nav-next { right: 14px; }&#xA;/* ---------- Ícones (máscara para que herdem currentColor) ---------- */&#xA;.pfvr-icon {&#xA;width: 20px;&#xA;height: 20px;&#xA;display: inline-block;&#xA;background-color: currentColor;&#xA;-webkit-mask-repeat: no-repeat;&#xA;mask-repeat: no-repeat;&#xA;-webkit-mask-position: center;&#xA;mask-position: center;&#xA;-webkit-mask-size: contain;&#xA;mask-size: contain;&#xA;}&#xA;.pfvr-icon-prev {&#xA;-webkit-mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M15.4 7.4 14 6l-6 6 6 6 1.4-1.4L10.8 12z&#39;/%3E%3C/svg%3E&#34;);&#xA;mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M15.4 7.4 14 6l-6 6 6 6 1.4-1.4L10.8 12z&#39;/%3E%3C/svg%3E&#34;);&#xA;}&#xA;.pfvr-icon-next {&#xA;-webkit-mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M8.6 7.4 10 6l6 6-6 6-1.4-1.4L13.2 12z&#39;/%3E%3C/svg%3E&#34;);&#xA;mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M8.6 7.4 10 6l6 6-6 6-1.4-1.4L13.2 12z&#39;/%3E%3C/svg%3E&#34;);&#xA;}&#xA;.pfvr-icon-fs {&#xA;width: 18px;&#xA;height: 18px;&#xA;-webkit-mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M7 14H5v5h5v-2H7v-3zm-2-4h2V7h3V5H5v5zm12 7h-3v2h5v-5h-2v3zM14 5v2h3v3h2V5h-5z&#39;/%3E%3C/svg%3E&#34;);&#xA;mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M7 14H5v5h5v-2H7v-3zm-2-4h2V7h3V5H5v5zm12 7h-3v2h5v-5h-2v3zM14 5v2h3v3h2V5h-5z&#39;/%3E%3C/svg%3E&#34;);&#xA;}&#xA;.pfvr-icon-auto {&#xA;width: 19px;&#xA;height: 19px;&#xA;-webkit-mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M17.65 6.35A8 8 0 1 0 19.73 14h-2.08A6 6 0 1 1 12 6c1.66 0 3.14.69 4.22 1.78L13 11h7V4z&#39;/%3E%3C/svg%3E&#34;);&#xA;mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M17.65 6.35A8 8 0 1 0 19.73 14h-2.08A6 6 0 1 1 12 6c1.66 0 3.14.69 4.22 1.78L13 11h7V4z&#39;/%3E%3C/svg%3E&#34;);&#xA;}&#xA;.pfvr-auto-btn.is-off {&#xA;opacity: 0.45;&#xA;}&#xA;.pfvr-fs-btn.is-fullscreen .pfvr-icon-fs {&#xA;opacity: 0.7;&#xA;}&#xA;/* ---------- Painel de informações ---------- */&#xA;.pfvr-info {&#xA;position: absolute;&#xA;left: 14px;&#xA;bottom: 116px;&#xA;max-width: min(440px, calc(100% - 28px));&#xA;padding: 12px 16px;&#xA;background: rgba(10, 14, 20, 0.62);&#xA;border: 1px solid rgba(255, 255, 255, 0.1);&#xA;border-radius: 10px;&#xA;backdrop-filter: blur(8px);&#xA;-webkit-backdrop-filter: blur(8px);&#xA;}&#xA;.pfvr-info[hidden] {&#xA;display: none;&#xA;}&#xA;.pfvr-scene-title {&#xA;font-size: 16px;&#xA;font-weight: 700;&#xA;line-height: 1.35;&#xA;margin-bottom: 4px;&#xA;}&#xA;.pfvr-scene-desc {&#xA;font-size: 13px;&#xA;line-height: 1.6;&#xA;color: rgba(255, 255, 255, 0.85);&#xA;word-break: break-word;&#xA;}&#xA;.pfvr-scene-desc p {&#xA;margin: 0 0 6px;&#xA;}&#xA;.pfvr-scene-desc p:last-child {&#xA;margin-bottom: 0;&#xA;}&#xA;/* ---------- Faixa de miniaturas ---------- */&#xA;.pfvr-thumbs {&#xA;position: absolute;&#xA;left: 0;&#xA;right: 0;&#xA;bottom: 0;&#xA;display: flex;&#xA;gap: 10px;&#xA;padding: 10px 76px 12px 14px; /* o espaço à direita deixa lugar para o botão de RV do A-Frame */&#xA;overflow-x: auto;&#xA;scrollbar-width: thin;&#xA;scrollbar-color: rgba(255, 255, 255, 0.35) transparent;&#xA;background: linear-gradient(to top, rgba(0, 0, 0, 0.55), rgba(0, 0, 0, 0));&#xA;}&#xA;.pfvr-thumbs::-webkit-scrollbar {&#xA;height: 6px;&#xA;}&#xA;.pfvr-thumbs::-webkit-scrollbar-thumb {&#xA;background: rgba(255, 255, 255, 0.3);&#xA;border-radius: 3px;&#xA;}&#xA;.pfvr-thumb {&#xA;flex: 0 0 auto;&#xA;width: 108px;&#xA;padding: 0;&#xA;border: 2px solid transparent;&#xA;border-radius: 8px;&#xA;overflow: hidden;&#xA;background: rgba(255, 255, 255, 0.08);&#xA;cursor: pointer;&#xA;text-align: left;&#xA;transition: border-color 0.15s ease, transform 0.15s ease;&#xA;}&#xA;.pfvr-thumb:hover {&#xA;transform: translateY(-2px);&#xA;}&#xA;.pfvr-thumb img {&#xA;display: block;&#xA;width: 108px;&#xA;height: 64px;&#xA;object-fit: cover;&#xA;}&#xA;.pfvr-thumb-label {&#xA;display: block;&#xA;padding: 4px 6px;&#xA;font-size: 11px;&#xA;line-height: 1.3;&#xA;color: rgba(255, 255, 255, 0.88);&#xA;white-space: nowrap;&#xA;overflow: hidden;&#xA;text-overflow: ellipsis;&#xA;}&#xA;.pfvr-thumb.is-active {&#xA;border-color: #42a5f5;&#xA;box-shadow: 0 0 0 1px rgba(66, 165, 245, 0.6);&#xA;}&#xA;.pfvr-thumb.is-active .pfvr-thumb-label {&#xA;color: #90caf9;&#xA;}&#xA;/* ---------- Indicador de carregamento ---------- */&#xA;.pfvr-loader {&#xA;position: absolute;&#xA;inset: 0;&#xA;display: flex;&#xA;align-items: center;&#xA;justify-content: center;&#xA;pointer-events: none;&#xA;}&#xA;.pfvr-spinner {&#xA;width: 42px;&#xA;height: 42px;&#xA;border: 3px solid rgba(255, 255, 255, 0.2);&#xA;border-top-color: #42a5f5;&#xA;border-radius: 50%;&#xA;animation: pfvr-spin 0.9s linear infinite;&#xA;}&#xA;@keyframes pfvr-spin {&#xA;to {&#xA;transform: rotate(360deg);&#xA;}&#xA;}&#xA;.pfvr-viewer:not(.pfvr-loading) .pfvr-loader {&#xA;display: none;&#xA;}&#xA;/* ---------- Tela cheia ---------- */&#xA;.pfvr-viewer:fullscreen,&#xA;.pfvr-viewer:-webkit-full-screen {&#xA;height: 100%;&#xA;border-radius: 0;&#xA;}&#xA;.pfvr-viewer:fullscreen .pfvr-info {&#xA;bottom: 120px;&#xA;}&#xA;/* ---------- Telas pequenas ---------- */&#xA;@media (max-width: 600px) {&#xA;.pfvr-viewer {&#xA;border-radius: 6px;&#xA;}&#xA;.pfvr-info {&#xA;left: 8px;&#xA;right: 8px;&#xA;bottom: 108px;&#xA;max-width: none;&#xA;padding: 10px 12px;&#xA;}&#xA;.pfvr-scene-title {&#xA;font-size: 14px;&#xA;}&#xA;.pfvr-scene-desc {&#xA;font-size: 12px;&#xA;}&#xA;.pfvr-nav {&#xA;width: 34px;&#xA;height: 34px;&#xA;}&#xA;.pfvr-nav-prev { left: 6px; }&#xA;.pfvr-nav-next { right: 6px; }&#xA;.pfvr-thumb {&#xA;width: 92px;&#xA;}&#xA;.pfvr-thumb img {&#xA;width: 92px;&#xA;height: 56px;&#xA;}&#xA;.pfvr-topbar {&#xA;padding: 8px 10px;&#xA;}&#xA;}&#xA;/* Aviso voltado ao editor para shortcodes configurados incorretamente. */&#xA;.pfvr-notice {&#xA;padding: 12px 16px;&#xA;background: #fcf0f1;&#xA;border-left: 4px solid #d63638;&#xA;color: #3c434a;&#xA;}&#xA;&lt;/style&gt;&#xA;&lt;script src=&#34;https://pengchi.net/wp-content/plugins/playforge-vr/assets/vendor/aframe.min.js&#34;&gt;&lt;/script&gt;&#xA;&lt;div&#xA;id=&#34;pfvr-viewer-624-1&#34;&#xA;class=&#34;pfvr-viewer pfvr-loading&#34;&#xA;style=&#34;--pfvr-height: 100vh;&#34;&#xA;data-scene=&#34;0&#34;&#xA;data-autoplay=&#34;1&#34;&#xA;data-preload=&#34;all&#34;&#xA;tabindex=&#34;0&#34;&#xA;&gt;&#xA;&lt;a-scene&#xA;embedded&#xA;loading-screen=&#34;enabled: false&#34;&#xA;vr-mode-ui=&#34;enabled: true&#34;&#xA;renderer=&#34;colorManagement: true; antialias: true&#34;&#xA;&gt;&#xA;&lt;a-assets timeout=&#34;30000&#34;&gt;&#xA;&lt;img&#xA;id=&#34;pfvr-a-0&#34;&#xA;src=&#34;https://pengchi.net/wp-content/uploads/2026/09/Wuhan-Fifth-Hospital_OR-Corridor_4K_4096x2048-scaled.jpg&#34;&#xA;alt=&#34;&#34;&#xA;&gt;&#xA;&lt;img&#xA;id=&#34;pfvr-a-1&#34;&#xA;src=&#34;https://pengchi.net/wp-content/uploads/2026/09/Wuhan-Fifth-Hospital_OR-2_4K_4096x2048-scaled.jpg&#34;&#xA;alt=&#34;&#34;&#xA;&gt;&#xA;&lt;img&#xA;id=&#34;pfvr-a-2&#34;&#xA;src=&#34;https://pengchi.net/wp-content/uploads/2026/09/Wuhan-Fifth-Hospital_OR-1_4K_4096x2048-scaled.jpg&#34;&#xA;alt=&#34;&#34;&#xA;&gt;&#xA;&lt;/a-assets&gt;&#xA;&lt;a-sky data-role=&#34;sky&#34; src=&#34;#pfvr-a-0&#34;&gt;&lt;/a-sky&gt;&#xA;&lt;a-entity data-role=&#34;rig&#34; pfvr-auto=&#34;speed: 0.06; enabled: true&#34;&gt;&#xA;&lt;a-entity camera look-controls=&#34;reverseMouseDrag: true&#34; fov=&#34;80&#34;&gt;&lt;/a-entity&gt;&#xA;&lt;/a-entity&gt;&#xA;&lt;/a-scene&gt;&#xA;&lt;div class=&#34;pfvr-overlay&#34;&gt;&#xA;&lt;div class=&#34;pfvr-topbar pfvr-ui&#34;&gt;&#xA;&lt;select class=&#34;pfvr-select&#34; aria-label=&#34;Mudar de cena por título&#34;&gt;&lt;/select&gt;&#xA;&lt;div class=&#34;pfvr-top-actions&#34;&gt;&#xA;&lt;button type=&#34;button&#34; class=&#34;pfvr-btn pfvr-auto-btn&#34; aria-label=&#34;Alternar rotação automática&#34; title=&#34;Rotação automática&#34;&gt;&#xA;&lt;span class=&#34;pfvr-icon pfvr-icon-auto&#34; aria-hidden=&#34;true&#34;&gt;&lt;/span&gt;&#xA;&lt;/button&gt;&#xA;&lt;button type=&#34;button&#34; class=&#34;pfvr-btn pfvr-fs-btn&#34; aria-label=&#34;Tela cheia&#34; title=&#34;Tela cheia&#34;&gt;&#xA;&lt;span class=&#34;pfvr-icon pfvr-icon-fs&#34; aria-hidden=&#34;true&#34;&gt;&lt;/span&gt;&#xA;&lt;/button&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;pfvr-info&#34;&gt;&#xA;&lt;div class=&#34;pfvr-scene-title&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;pfvr-scene-desc&#34;&gt;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;button type=&#34;button&#34; class=&#34;pfvr-btn pfvr-nav pfvr-nav-prev pfvr-ui&#34; aria-label=&#34;Anterior&#34;&gt;&#xA;&lt;span class=&#34;pfvr-icon pfvr-icon-prev&#34; aria-hidden=&#34;true&#34;&gt;&lt;/span&gt;&#xA;&lt;/button&gt;&#xA;&lt;button type=&#34;button&#34; class=&#34;pfvr-btn pfvr-nav pfvr-nav-next pfvr-ui&#34; aria-label=&#34;Próximo&#34;&gt;&#xA;&lt;span class=&#34;pfvr-icon pfvr-icon-next&#34; aria-hidden=&#34;true&#34;&gt;&lt;/span&gt;&#xA;&lt;/button&gt;&#xA;&lt;div class=&#34;pfvr-thumbs pfvr-ui&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;pfvr-loader&#34; aria-hidden=&#34;true&#34;&gt;&#xA;&lt;span class=&#34;pfvr-spinner&#34;&gt;&lt;/span&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;script type=&#34;application/json&#34; class=&#34;pfvr-data&#34;&gt;[{&#34;id&#34;:&#34;scene-1790645683076-1&#34;,&#34;title&#34;:&#34;Corredor da sala de cirurgia&#34;,&#34;description&#34;:&#34;O corredor da sala de cirurgia é equipado com portas herméticas hospitalares, lavatórios de mãos em aço inoxidável 304 e outras instalações auxiliares.&#34;,&#34;image&#34;:&#34;/wp-content/uploads/2026/09/Wuhan-Fifth-Hospital_OR-Corridor_4K_4096x2048-scaled.jpg&#34;,&#34;thumb&#34;:&#34;/wp-content/uploads/2026/09/cropped-Wuhan-Fifth-Hospital_OR-Corridor_4K_4096x2048-scaled-1.jpg&#34;},{&#34;id&#34;:&#34;scene-1790645700912-2&#34;,&#34;title&#34;:&#34;Sala de Cirurgia 1&#34;,&#34;description&#34;:&#34;Projeto turnkey de sala de cirurgia modular Classe 100, incluindo armários de instrumentos, armários de anestesia, refrigeradores embutidos, tetos de fluxo laminar, difusores HEPA de insuflação de ar, painéis de controle de temperatura e umidade, terminais de saída de gases medicinais, painéis de tomadas elétricas, etc. Painéis de parede com cantos curvos, fáceis de limpar e sem cantos mortos de higienização.&#34;,&#34;image&#34;:&#34;/wp-content/uploads/2026/09/Wuhan-Fifth-Hospital_OR-2_4K_4096x2048-scaled.jpg&#34;,&#34;thumb&#34;:&#34;/wp-content/uploads/2026/09/cropped-Wuhan-Fifth-Hospital_OR-2_4K_4096x2048-scaled-1.jpg&#34;},{&#34;id&#34;:&#34;scene-1790645733838-3&#34;,&#34;title&#34;:&#34;Sala de Cirurgia 2&#34;,&#34;description&#34;:&#34;Este é um projeto turnkey de sala de cirurgia modular ISO Classe 5, equipada com armários de instrumentos, armários de anestesia e refrigeradores embutidos. Também é composta por tetos de fluxo laminar, difusores HEPA de insuflação de ar, painéis de controle de temperatura \u0026amp; umidade, terminais de saída de gases medicinais, painéis de tomadas elétricas, caixas de luz para visualização de filmes de raios-X, painéis de iluminação herméticos e carrinhos de sala de cirurgia. São adotados painéis de parede com cantos curvos para facilitar a limpeza e eliminar os cantos mortos de higienização.&#34;,&#34;image&#34;:&#34;/wp-content/uploads/2026/09/Wuhan-Fifth-Hospital_OR-1_4K_4096x2048-scaled.jpg&#34;,&#34;thumb&#34;:&#34;/wp-content/uploads/2026/09/cropped-Wuhan-Fifth-Hospital_OR-1_4K_4096x2048-scaled-1.jpg&#34;}]&lt;/script&gt;&#xA;&lt;/div&gt;&#xA;&lt;script&gt;/**&#xA;* Lógica de front-end para os visualizadores PlayForge VR.&#xA;*&#xA;* Lê o JSON de cenas renderizado pelo shortcode, constrói o seletor de títulos,&#xA;* a faixa de miniaturas e o painel de informações, e troca a textura do &lt;a-sky&gt; na mudança.&#xA;*/&#xA;( function () {&#xA;&#39;use strict&#39;;&#xA;/**&#xA;* Componente A-Frame: rotação lenta de guinada (yaw) do rig da câmera.&#xA;*&#xA;* Pausa enquanto o visitante arrasta/olha ao redor e retoma após um&#xA;* intervalo de inatividade, para nunca interferir nos controles do visualizador.&#xA;*/&#xA;function registerAutoComponent() {&#xA;if ( ! window.AFRAME || window.AFRAME.components[ &#39;pfvr-auto&#39; ] ) {&#xA;return;&#xA;}&#xA;window.AFRAME.registerComponent( &#39;pfvr-auto&#39;, {&#xA;schema: {&#xA;speed: { default: 0.06 }, // radianos por segundo.&#xA;enabled: { default: true }&#xA;},&#xA;init: function () {&#xA;this.userPaused = false;&#xA;this.tempPaused = false;&#xA;this.resumeTimer = null;&#xA;var self = this;&#xA;var pauseTemporarily = function () {&#xA;self.tempPaused = true;&#xA;window.clearTimeout( self.resumeTimer );&#xA;self.resumeTimer = window.setTimeout( function () {&#xA;self.tempPaused = false;&#xA;}, 4000 );&#xA;};&#xA;// O canvas recebe os eventos de ponteiro/toque que o look-controls utiliza.&#xA;var bind = function () {&#xA;var canvas = self.el.sceneEl.canvas;&#xA;if ( ! canvas ) {&#xA;return;&#xA;}&#xA;canvas.addEventListener( &#39;pointerdown&#39;, pauseTemporarily );&#xA;canvas.addEventListener( &#39;wheel&#39;, pauseTemporarily, { passive: true } );&#xA;canvas.addEventListener( &#39;touchstart&#39;, pauseTemporarily, { passive: true } );&#xA;};&#xA;if ( this.el.sceneEl.canvas ) {&#xA;bind();&#xA;} else {&#xA;this.el.sceneEl.addEventListener( &#39;rendertargetchanged&#39;, bind );&#xA;window.setTimeout( bind, 500 );&#xA;}&#xA;},&#xA;setEnabled: function ( enabled ) {&#xA;this.userPaused = ! enabled;&#xA;},&#xA;tick: function ( _time, delta ) {&#xA;if (&#xA;! this.data.enabled ||&#xA;this.userPaused ||&#xA;this.tempPaused ||&#xA;document.hidden&#xA;) {&#xA;return;&#xA;}&#xA;this.el.object3D.rotation.y += ( delta / 1000 ) * this.data.speed;&#xA;}&#xA;} );&#xA;}&#xA;/** Cria um span de ícone com uma classe (o conteúdo vem do CSS). */&#xA;function icon( className ) {&#xA;var span = document.createElement( &#39;span&#39; );&#xA;span.className = &#39;pfvr-icon &#39; + className;&#xA;span.setAttribute( &#39;aria-hidden&#39;, &#39;true&#39; );&#xA;return span;&#xA;}&#xA;/**&#xA;* Inicializa um elemento de visualizador.&#xA;*&#xA;* @param {HTMLElement} viewer Elemento raiz .pfvr-viewer.&#xA;*/&#xA;function initViewer( viewer ) {&#xA;var dataEl = viewer.querySelector( &#39;.pfvr-data&#39; );&#xA;var scenes;&#xA;try {&#xA;scenes = JSON.parse( dataEl.textContent || &#39;{}&#39; );&#xA;} catch ( e ) {&#xA;scenes = [];&#xA;}&#xA;if ( ! Array.isArray( scenes ) || ! scenes.length ) {&#xA;return;&#xA;}&#xA;var sky = viewer.querySelector( &#39;[data-role=&#34;sky&#34;]&#39; );&#xA;var rig = viewer.querySelector( &#39;[data-role=&#34;rig&#34;]&#39; );&#xA;var select = viewer.querySelector( &#39;.pfvr-select&#39; );&#xA;var thumbs = viewer.querySelector( &#39;.pfvr-thumbs&#39; );&#xA;var infoTitle = viewer.querySelector( &#39;.pfvr-scene-title&#39; );&#xA;var infoDesc = viewer.querySelector( &#39;.pfvr-scene-desc&#39; );&#xA;var infoBox = viewer.querySelector( &#39;.pfvr-info&#39; );&#xA;var loader = viewer.querySelector( &#39;.pfvr-loader&#39; );&#xA;var autoBtn = viewer.querySelector( &#39;.pfvr-auto-btn&#39; );&#xA;var fsBtn = viewer.querySelector( &#39;.pfvr-fs-btn&#39; );&#xA;var prevBtn = viewer.querySelector( &#39;.pfvr-nav-prev&#39; );&#xA;var nextBtn = viewer.querySelector( &#39;.pfvr-nav-next&#39; );&#xA;var current = Math.min(&#xA;parseInt( viewer.getAttribute( &#39;data-scene&#39; ), 10 ) || 0,&#xA;scenes.length - 1&#xA;);&#xA;var autoEnabled = viewer.getAttribute( &#39;data-autoplay&#39; ) === &#39;1&#39;;&#xA;var preloadAll = viewer.getAttribute( &#39;data-preload&#39; ) === &#39;all&#39;;&#xA;var assetsBox = viewer.querySelector( &#39;a-assets&#39; );&#xA;var loadFallbackTimer = null;&#xA;// Constrói o &lt;select&gt; de títulos.&#xA;scenes.forEach( function ( scene, i ) {&#xA;var option = document.createElement( &#39;option&#39; );&#xA;option.value = String( i );&#xA;option.textContent = scene.title || &#39;Cena &#39; + ( i + 1 );&#xA;select.appendChild( option );&#xA;} );&#xA;// Constrói a faixa de miniaturas.&#xA;var thumbButtons = [];&#xA;scenes.forEach( function ( scene, i ) {&#xA;var button = document.createElement( &#39;button&#39; );&#xA;button.type = &#39;button&#39;;&#xA;button.className = &#39;pfvr-thumb&#39;;&#xA;button.setAttribute( &#39;aria-label&#39;, scene.title || &#39;Cena &#39; + ( i + 1 ) );&#xA;var img = document.createElement( &#39;img&#39; );&#xA;img.src = scene.thumb || &#39;&#39;;&#xA;img.alt = &#39;&#39;;&#xA;img.addEventListener( &#39;error&#39;, function () {&#xA;img.style.display = &#39;none&#39;;&#xA;} );&#xA;var label = document.createElement( &#39;span&#39; );&#xA;label.className = &#39;pfvr-thumb-label&#39;;&#xA;label.textContent = scene.title || &#39;Cena &#39; + ( i + 1 );&#xA;button.appendChild( img );&#xA;button.appendChild( label );&#xA;button.addEventListener( &#39;click&#39;, function () {&#xA;goTo( i );&#xA;} );&#xA;thumbs.appendChild( button );&#xA;thumbButtons.push( button );&#xA;} );&#xA;/**&#xA;* Garante que a cena i exista como um &lt;img&gt; dentro de &lt;a-assets&gt;, criando-o&#xA;* se necessário. O A-Frame então o carrega e armazena a textura em cache na GPU,&#xA;* de modo que apontar o céu para ela é instantâneo após o carregamento.&#xA;*&#xA;* @param {number} i Índice da cena.&#xA;*/&#xA;function ensureAsset( i ) {&#xA;if ( ! assetsBox || ! scenes[ i ] ) {&#xA;return;&#xA;}&#xA;var id = &#39;pfvr-a-&#39; + i;&#xA;if ( document.getElementById( id ) ) {&#xA;return;&#xA;}&#xA;var img = document.createElement( &#39;img&#39; );&#xA;img.id = id;&#xA;img.alt = &#39;&#39;;&#xA;img.src = scenes[ i ].image;&#xA;assetsBox.appendChild( img );&#xA;}&#xA;/** Pré-carrega uma cena como asset do A-Frame (aquece o cache de rede + GPU). */&#xA;function preload( i ) {&#xA;ensureAsset( i );&#xA;}&#xA;/** Oculta o spinner de carregamento assim que a nova textura estiver no céu. */&#xA;function hideLoader() {&#xA;window.clearTimeout( loadFallbackTimer );&#xA;viewer.classList.remove( &#39;pfvr-loading&#39; );&#xA;if ( loader ) {&#xA;loader.style.display = &#39;none&#39;;&#xA;}&#xA;}&#xA;/**&#xA;* Muda para uma cena pelo índice.&#xA;*&#xA;* @param {number} i Índice de destino.&#xA;*/&#xA;function goTo( i ) {&#xA;if ( i === current || i &lt; 0 || i &gt;= scenes.length ) {&#xA;return;&#xA;}&#xA;current = i;&#xA;viewer.classList.add( &#39;pfvr-loading&#39; );&#xA;if ( loader ) {&#xA;loader.style.display = &#39;&#39;;&#xA;}&#xA;var settled = false;&#xA;var finish = function () {&#xA;if ( settled ) {&#xA;return;&#xA;}&#xA;settled = true;&#xA;hideLoader();&#xA;sky.removeEventListener( &#39;materialtextureloaded&#39;, finish );&#xA;sky.removeEventListener( &#39;materialtextureerror&#39;, finish );&#xA;};&#xA;// Rede de segurança: nunca deixa o spinner travado se nenhum evento for disparado.&#xA;window.clearTimeout( loadFallbackTimer );&#xA;loadFallbackTimer = window.setTimeout( finish, 9000 );&#xA;sky.addEventListener( &#39;materialtextureloaded&#39;, finish );&#xA;sky.addEventListener( &#39;materialtextureerror&#39;, finish );&#xA;// Garante que a imagem de destino esteja em &lt;a-assets&gt; e, em seguida,&#xA;// referencia-a por ID para que o cache de texturas do A-Frame seja reutilizado.&#xA;ensureAsset( i );&#xA;sky.setAttribute( &#39;src&#39;, &#39;#pfvr-a-&#39; + i );&#xA;// Quando a imagem de destino já terminou de carregar, o A-Frame pode&#xA;// resolver o material de forma síncrona sem emitir um evento;&#xA;// nesse caso, oculta o spinner no próximo quadro.&#xA;var targetImg = document.getElementById( &#39;pfvr-a-&#39; + i );&#xA;if ( targetImg &amp;&amp; targetImg.complete &amp;&amp; targetImg.naturalWidth ) {&#xA;window.requestAnimationFrame( function () {&#xA;window.requestAnimationFrame( finish );&#xA;} );&#xA;}&#xA;updateUI();&#xA;preload( ( i + 1 ) % scenes.length );&#xA;preload( ( i - 1 + scenes.length ) % scenes.length );&#xA;}&#xA;/** Atualiza os estados ativos de título/descrição/seletor/miniaturas. */&#xA;function updateUI() {&#xA;var scene = scenes[ current ];&#xA;select.value = String( current );&#xA;infoTitle.textContent = scene.title || &#39;&#39;;&#xA;if ( scene.description &amp;&amp; scene.description.trim() ) {&#xA;infoDesc.innerHTML = scene.description;&#xA;infoBox.hidden = false;&#xA;} else {&#xA;infoDesc.innerHTML = &#39;&#39;;&#xA;infoBox.hidden = ! scene.title;&#xA;}&#xA;thumbButtons.forEach( function ( button, i ) {&#xA;button.classList.toggle( &#39;is-active&#39;, i === current );&#xA;} );&#xA;// Mantém a miniatura ativa visível na faixa com rolagem.&#xA;var active = thumbButtons[ current ];&#xA;if ( active &amp;&amp; active.scrollIntoView ) {&#xA;active.scrollIntoView( { behavior: &#39;smooth&#39;, inline: &#39;center&#39;, block: &#39;nearest&#39; } );&#xA;}&#xA;}&#xA;// --- Eventos da interface ---------------------------------------------&#xA;select.addEventListener( &#39;change&#39;, function () {&#xA;goTo( parseInt( select.value, 10 ) );&#xA;} );&#xA;prevBtn.addEventListener( &#39;click&#39;, function () {&#xA;goTo( ( current - 1 + scenes.length ) % scenes.length );&#xA;} );&#xA;nextBtn.addEventListener( &#39;click&#39;, function () {&#xA;goTo( ( current + 1 ) % scenes.length );&#xA;} );&#xA;autoBtn.addEventListener( &#39;click&#39;, function () {&#xA;autoEnabled = ! autoEnabled;&#xA;setAutoButtonState();&#xA;if ( rig.components &amp;&amp; rig.components[ &#39;pfvr-auto&#39; ] ) {&#xA;rig.components[ &#39;pfvr-auto&#39; ].setEnabled( autoEnabled );&#xA;}&#xA;rig.setAttribute( &#39;pfvr-auto&#39;, &#39;enabled&#39;, autoEnabled ? &#39;true&#39; : &#39;false&#39; );&#xA;} );&#xA;function setAutoButtonState() {&#xA;autoBtn.classList.toggle( &#39;is-off&#39;, ! autoEnabled );&#xA;autoBtn.setAttribute( &#39;aria-pressed&#39;, autoEnabled ? &#39;true&#39; : &#39;false&#39; );&#xA;}&#xA;// Tela cheia.&#xA;fsBtn.addEventListener( &#39;click&#39;, function () {&#xA;if ( document.fullscreenElement ) {&#xA;document.exitFullscreen();&#xA;} else if ( viewer.requestFullscreen ) {&#xA;viewer.requestFullscreen();&#xA;} else if ( viewer.webkitRequestFullscreen ) {&#xA;viewer.webkitRequestFullscreen();&#xA;}&#xA;} );&#xA;document.addEventListener( &#39;fullscreenchange&#39;, function () {&#xA;fsBtn.classList.toggle( &#39;is-fullscreen&#39;, !! document.fullscreenElement );&#xA;} );&#xA;// Teclado: só age quando este visualizador está focado ou em tela cheia.&#xA;viewer.addEventListener( &#39;keydown&#39;, function ( event ) {&#xA;if (&#xA;document.fullscreenElement !== viewer &amp;&amp;&#xA;! viewer.contains( document.activeElement )&#xA;) {&#xA;return;&#xA;}&#xA;if ( event.key === &#39;ArrowRight&#39; ) {&#xA;event.preventDefault();&#xA;goTo( ( current + 1 ) % scenes.length );&#xA;} else if ( event.key === &#39;ArrowLeft&#39; ) {&#xA;event.preventDefault();&#xA;goTo( ( current - 1 + scenes.length ) % scenes.length );&#xA;}&#xA;} );&#xA;// Galerias de cena única não precisam de elementos de navegação.&#xA;if ( scenes.length === 1 ) {&#xA;prevBtn.style.display = &#39;none&#39;;&#xA;nextBtn.style.display = &#39;none&#39;;&#xA;thumbs.style.display = &#39;none&#39;;&#xA;select.style.display = &#39;none&#39;;&#xA;}&#xA;// --- Estado inicial -------------------------------------------------&#xA;setAutoButtonState();&#xA;updateUI();&#xA;// O modo &#34;all&#34; já enviou todas as imagens no &lt;a-assets&gt;; no modo &#34;adjacent&#34;,&#xA;// pré-carrega ambos os vizinhos da cena inicial.&#xA;if ( ! preloadAll ) {&#xA;preload( ( current + 1 ) % scenes.length );&#xA;preload( ( current - 1 + scenes.length ) % scenes.length );&#xA;}&#xA;// Oculta o spinner assim que a primeira textura for carregada.&#xA;var onInitialLoaded = function () {&#xA;hideLoader();&#xA;sky.removeEventListener( &#39;materialtextureloaded&#39;, onInitialLoaded );&#xA;sky.removeEventListener( &#39;materialtextureerror&#39;, onInitialError );&#xA;};&#xA;var onInitialError = function () {&#xA;hideLoader();&#xA;sky.removeEventListener( &#39;materialtextureloaded&#39;, onInitialLoaded );&#xA;sky.removeEventListener( &#39;materialtextureerror&#39;, onInitialError );&#xA;};&#xA;sky.addEventListener( &#39;materialtextureloaded&#39;, onInitialLoaded );&#xA;sky.addEventListener( &#39;materialtextureerror&#39;, onInitialError );&#xA;window.setTimeout( hideLoader, 9000 );&#xA;}&#xA;function boot() {&#xA;registerAutoComponent();&#xA;document.querySelectorAll( &#39;.pfvr-viewer&#39; ).forEach( initViewer );&#xA;}&#xA;if ( document.readyState === &#39;loading&#39; ) {&#xA;document.addEventListener( &#39;DOMContentLoaded&#39;, boot );&#xA;} else {&#xA;boot();&#xA;}&#xA;} )();&#xA;&lt;/script&gt;</description>
			</item>
			<item>
				<title>CMEF 2025 pengchi</title>
				<link>https://pengchi.net/pt/news/cmef-2025-pengchi/</link>
				<pubDate>Wed, 07 Oct 2026 07:50:23 +0000</pubDate>
				<guid>https://pengchi.net/pt/news/cmef-2025-pengchi/</guid>
				<description></description>
			</item>
			<item>
				<title>Pengchi na 93ª CMEF Xangai 2026 | Resumo da exposição</title>
				<link>https://pengchi.net/pt/news/pengchi-at-the-93rd-cmef-shanghai-2026-exhibition-review/</link>
				<pubDate>Wed, 07 Oct 2026 07:50:23 +0000</pubDate>
				<guid>https://pengchi.net/pt/news/pengchi-at-the-93rd-cmef-shanghai-2026-exhibition-review/</guid>
				<description>&lt;p class=&#34;isSelectedEnd&#34;&gt;A Dongguan Pengchi Intelligent Equipment Technology Co., Ltd. participou da 93ª Feira Internacional de Equipamentos Médicos da China (CMEF), realizada em Xangai, na China, de 9 a 12 de abril de 2026. A exposição proporcionou uma oportunidade para apresentar o mobiliário médico, as soluções modulares para salas de cirurgia, as portas médicas e o mobiliário de laboratório da Pengchi a profissionais de todo o setor de saúde.&lt;/p&gt;&#xA;&lt;p class=&#34;isSelectedEnd&#34;&gt;Como fabricante de equipamentos médicos e para salas limpas, a Pengchi continua focada no design prático de produtos, na qualidade de fabricação e em soluções personalizadas para hospitais, unidades de saúde, laboratórios e projetos de construção médica.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Como uma clínica de Davao construiu um laboratório clínico interno</title>
				<link>https://pengchi.net/pt/medical/how-a-davao-clinic-built-an-in-house-clinical-laboratory/</link>
				<pubDate>Tue, 06 Oct 2026 00:47:18 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical/how-a-davao-clinic-built-an-in-house-clinical-laboratory/</guid>
				<description>&lt;p&gt;Em 2024, uma clínica particular em Davao, Filipinas, fez uma parceria com a Pengchi para reformar seus principais departamentos clínicos. O projeto abrangeu otorrinolaringologia, oftalmologia, odontologia e departamentos ambulatoriais gerais. Os produtos fornecidos incluíram bancadas clínicas, armários médicos, estações de desinfecção e outras soluções de móveis sob medida.&lt;/p&gt;&#xA;&lt;p&gt;Nos dois anos seguintes, esses sistemas de móveis continuaram a apoiar as operações diárias da clínica conforme o volume de pacientes aumentava. No entanto, a clínica planejava inaugurar um laboratório clínico nas próprias instalações, e o espaço existente não tinha infraestrutura laboratorial específica. Sem móveis de laboratório adequados e infraestrutura de ventilação, a clínica não poderia implementar exames internos de sangue e urina. Essa lacuna atrasava consultas de retorno, liberações odontológicas, planejamentos terapêuticos em otorrino e avaliações de doenças crônicas.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Soluções</title>
				<link>https://pengchi.net/pt/solutions/</link>
				<pubDate>Wed, 30 Sep 2026 03:43:37 +0000</pubDate>
				<guid>https://pengchi.net/pt/solutions/</guid>
				<description>&lt;section class=&#34;text-white&#34; style=&#34;width: 100vw;max-width: 100vw;margin-left: calc(50% - 50vw);background: linear-gradient(rgba(9, 33, 43, 0.78), rgba(9, 33, 43, 0.86)), url(&#39;/wp-content/uploads/2026/09/Factory-Aerial-View-scaled.jpg&#39;) center center / cover no-repeat&#34;&gt;&#xA;&lt;div class=&#34;container py-5&#34;&gt;&#xA;&lt;div class=&#34;row justify-content-center text-center&#34;&gt;&#xA;&lt;div class=&#34;col-lg-10&#34;&gt;&#xA;&lt;p&gt;&lt;span class=&#34;badge rounded-pill text-bg-light text-success text-uppercase px-3 py-2 mb-3&#34;&gt;Solução Médica Completa&lt;/span&gt;&lt;/p&gt;&#xA;&lt;h1 class=&#34;fw-bold lh-sm mb-3&#34; style=&#34;font-size: clamp(1.9rem, 4vw, 3.1rem)&#34;&gt;Portas Hospitalares, Salas de Cirurgia Modulares e Mobiliário Hospitalar para Projetos de Saúde&lt;/h1&gt;&#xA;&lt;p class=&#34;lead text-white-50 mb-4 mx-auto&#34; style=&#34;max-width: 820px&#34;&gt;A Pengchi apoia hospitais, clínicas e laboratórios desde o planeamento de espaços e a configuração por departamento até ao fabrico direto de fábrica, entrega e instalação — uma equipa, documentação completa.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Guia do Visitante da CMEF 2026: Descubra as Soluções Líderes em Salas Cirúrgicas Modulares e Ambientes Médicos na China</title>
				<link>https://pengchi.net/pt/news/cmef-2026-visitor-guide-discover-leading-modular-operating-room-and-medical-environment-solutions-in-china/</link>
				<pubDate>Tue, 29 Sep 2026 07:35:07 +0000</pubDate>
				<guid>https://pengchi.net/pt/news/cmef-2026-visitor-guide-discover-leading-modular-operating-room-and-medical-environment-solutions-in-china/</guid>
				<description>&lt;h2&gt;Informações sobre a Exposição CMEF 2026&lt;/h2&gt;&#xA;[caption id=&#34;attachment_1169&#34; align=&#34;aligncenter&#34; width=&#34;1080&#34;]&lt;img class=&#34;wp-image-1169 size-full&#34; src=&#34;https://pengchi.net/wp-content/uploads/2026/09/cmef.jpg&#34; alt=&#34;Feira Internacional de Equipamentos Médicos da China CMEF 2025&#34; width=&#34;1080&#34; height=&#34;810&#34; /&gt; Feira Internacional de Equipamentos Médicos da China CMEF 2025[/caption]&#xA;&lt;p&gt;&lt;strong&gt;Feira Internacional de Equipamentos Médicos da China (CMEF)&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;94.ª CMEF&lt;/strong&gt;&#xA;&lt;strong&gt;Data:&lt;/strong&gt; 21 a 24 de outubro de 2026&#xA;&lt;strong&gt;Local:&lt;/strong&gt; Centro Internacional de Exposições e Convenções Capital, Pequim, China&lt;/p&gt;&#xA;&lt;p&gt;A 94.ª Feira Internacional de Equipamentos Médicos da China (CMEF) será realizada de&#xA;&lt;strong&gt;21 a 24 de outubro de 2026&lt;/strong&gt; no Centro Internacional de Exposições e Convenções Capital, em Pequim, China.&#xA;A CMEF é uma das maiores e mais influentes exposições da indústria médica da Ásia, conectando fabricantes de equipamentos médicos,&#xA;fornecedores de soluções de saúde, tomadores de decisão hospitalares, distribuidores e compradores internacionais.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Projeto de Sala de Operações e Portas Hospitalares do 5º Hospital de Wuhan</title>
				<link>https://pengchi.net/pt/projects/wuhan-5th-hospital-operating-room-and-hospital-door-project/</link>
				<pubDate>Tue, 29 Sep 2026 01:34:05 +0000</pubDate>
				<guid>https://pengchi.net/pt/projects/wuhan-5th-hospital-operating-room-and-hospital-door-project/</guid>
				<description>&lt;p&gt;[caption id=&amp;ldquo;attachment_635&amp;rdquo; align=&amp;ldquo;alignnone&amp;rdquo; width=&amp;ldquo;1024&amp;rdquo;]&lt;a href=&#34;https://pengchi.net/wp-content/uploads/2026/09/automatic-medical-doors-hospital-corridor-qQgvc5vF-1920x1080-1.jpg&#34;&gt;&lt;img class=&#34;wp-image-635 size-large&#34; src=&#34;https://pengchi.net/wp-content/uploads/2026/09/automatic-medical-doors-hospital-corridor-qQgvc5vF-1920x1080-1-1024x576.jpg&#34; alt=&#34;Porta médica de correr automática cinza-clara com um painel de observação de vidro vertical alto e estreito, instalada em moldura de metal clara ao lado de uma porta de dobradiça correspondente aberta. Leitores de controle de acesso pretos são fixados em paredes lisas de tom branco-gelo, com vista para um corredor clínico vazio e iluminado.&#34; width=&#34;1024&#34; height=&#34;576&#34; /&gt;&lt;/a&gt; Porta médica de correr automática cinza-clara com um painel de observação de vidro vertical alto e estreito, instalada em moldura de metal clara ao lado de uma porta de dobradiça correspondente aberta. Leitores de controle de acesso pretos são fixados em paredes lisas de tom branco-gelo, com vista para um corredor clínico vazio e iluminado.[/caption]&lt;/p&gt;</description>
			</item>
			<item>
				<title>Projeto de Portas Hospitalares e Salas Cirúrgicas Modulares Limpas no Hospital Popular de Boluo</title>
				<link>https://pengchi.net/pt/projects/project-of-medical-doors-and-clean-modular-operating-rooms-at-boluo-peoples-hospital/</link>
				<pubDate>Mon, 28 Sep 2026 12:22:19 +0000</pubDate>
				<guid>https://pengchi.net/pt/projects/project-of-medical-doors-and-clean-modular-operating-rooms-at-boluo-peoples-hospital/</guid>
				<description>&lt;h2 class=&#34;heading-2 ace-line old-record-id-Dbsefc6O3deq3qcOX5pcyL1Dnzd&#34;&gt;1. Visão Geral do Hospital Popular de Boluo&lt;/h2&gt;&#xA;&lt;div class=&#34;ace-line ace-line old-record-id-UWdqfyHdBdMECycDxxbc6kqHngf&#34;&gt;Fundado em 1937, o Hospital Popular de Boluo, também conhecido como Filial de Boluo do Hospital Central Popular de Huizhou, é o único hospital geral público terciário de Grau A no Condado de Boluo, Huizhou, Província de Guangdong. Integra tratamento médico, ensino, reabilitação, cuidados de saúde, prevenção de doenças, resgate de emergência e pesquisa científica, e atua como o principal centro de tratamento de doenças graves e centro de orientação técnica médica para todo o condado. Como hospital de ensino para universidades médicas de Guangdong e parceiro médico cooperativo do Primeiro Hospital Afiliado da Universidade de Sun Yat-sen, construiu 11 especialidades clínicas-chave municipais de Huizhou e formou um sistema completo de serviços médicos que abrange atendimento ambulatorial de rotina, cirurgias complexas e resgate de emergência. O novo campus do hospital ocupa uma área terrestre de 107.884 metros quadrados com uma área total de construção de 155.142,11 metros quadrados, equipado com 1.000 leitos autorizados e mais de 1.087 leitos efetivamente abertos. Possui um conjunto completo de edifícios médicos modernos, incluindo edifício de ambulatórios, edifício de tecnologia médica, edifício de internação, edifício de doenças infecciosas e um heliponto de emergência, assumindo pesadas tarefas médicas para residentes locais e pacientes de regiões vizinhas.&lt;/div&gt;&#xA;&lt;h2 class=&#34;heading-2 ace-line old-record-id-KzaNfjyvudJPzLc7XnlcQ3KKn0b&#34;&gt;2. Antecedentes do Projeto e Informações de Lançamento&lt;/h2&gt;&#xA;&lt;div class=&#34;ace-line ace-line old-record-id-E7VdfimAWdtEM4cyTvqcluWVnwh&#34;&gt;Com o crescimento contínuo da demanda local por serviços cirúrgicos de alto padrão, o hospital lançou o Projeto de Portas Médicas e Salas Cirúrgicas Modulares Limpas em agosto de 2023. Este projeto é uma parte central do plano de modernização do novo campus, com o objetivo de melhorar o ambiente cirúrgico, fortalecer a capacidade de controle de infecções hospitalares e criar um espaço operatório mais seguro e confiável para várias cirurgias de rotina e complexas. Todo o projeto abrange dois componentes principais: sistemas de portas médicas personalizadas e salas cirúrgicas modulares limpas pré-fabricadas, ambos seguindo as especificações nacionais de salas limpas de saúde e os padrões internacionais de salas limpas ISO 14644.&lt;/div&gt;&#xA;&lt;h2 class=&#34;heading-2 ace-line old-record-id-XPEhf1kWKdZYwqc6ddwczLn4nbb&#34;&gt;3. Vantagens Principais dos Sistemas de Portas Médicas Personalizadas&lt;/h2&gt;&#xA;&lt;div class=&#34;ace-line ace-line old-record-id-FhckftD3jdRiiccedZHcBFmrn4m&#34;&gt;As portas médicas fornecidas para este projeto são especialmente projetadas para áreas estéreis hospitalares. Ao contrário das portas de construção comuns, essas portas médicas herméticas adotam painéis antibacterianos sem costura, tiras de vedação hermética de EPDM e ferragens de aço inoxidável. As portas deslizantes automáticas para salas de cirurgia suportam acionamento por sensor sem toque, o que reduz efetivamente os riscos de contaminação cruzada causados pelo toque manual. A estrutura hermética estabiliza os diferenciais de pressão internos entre as zonas limpas e as zonas de amortecimento, evitando que partículas e microrganismos externos entrem nas áreas cirúrgicas. Todas as superfícies das portas são lisas, não porosas e resistentes à desinfecção repetida com desinfetantes médicos, atendendo a rigorosos requisitos diários de esterilização e manutenção em áreas clínicas de alto risco, como salas de cirurgia, salas de suprimentos estéreis e salas de preparação de anestesia.&lt;/div&gt;&#xA;&lt;h2 class=&#34;heading-2 ace-line old-record-id-E1gFfQTj2d4YaWcEJCOccL8gnob&#34;&gt;4. Características Técnicas das Salas Cirúrgicas Modulares Limpas&lt;/h2&gt;&#xA;&lt;div class=&#34;ace-line ace-line old-record-id-YMwUfdZ24dWkbscU3B8cLh4tnld&#34;&gt;As salas cirúrgicas modulares limpas adotam a filosofia de construção modular pré-fabricada em fábrica. Painéis de parede, sistemas de teto, unidades de fluxo de ar laminar, terminais de gases medicinais, painéis de controle e armários de suporte são pré-produzidos e inspecionados na fábrica antes de serem transportados para o local do hospital para montagem. Em comparação com a construção úmida tradicional no local, a instalação modular reduz bastante o ciclo de construção, diminui a poeira e a poluição no local e garante uma qualidade de construção estável. O sistema de purificação de ar laminar com filtros HEPA remove continuamente partículas e bactérias suspensas no ar dentro da sala de cirurgia, mantendo uma classificação de sala limpa estável durante a cirurgia. O layout separa rigorosamente as linhas de fluxo limpas, semilimpas e contaminadas para a equipe médica, pacientes e suprimentos, otimizando o fluxo de trabalho cirúrgico e minimizando a chance de infecção hospitalar.&lt;/div&gt;&#xA;&lt;h2 class=&#34;heading-2 ace-line old-record-id-STJ8fGPETdnHKncezyBczaOknRf&#34;&gt;5. Valor do Projeto e Impacto no Desenvolvimento do Hospital&lt;/h2&gt;&#xA;&lt;div class=&#34;ace-line ace-line old-record-id-RG40fHksxdWbNhcWPolc2G8Gnmf&#34;&gt;A implementação deste projeto forneceu um suporte físico sólido para que o Hospital Popular de Boluo expandisse a capacidade cirúrgica após a mudança para seu novo campus em setembro de 2023. Ao construir salas cirúrgicas limpas modulares padronizadas e sistemas de portas médicas de alto desempenho correspondentes, o hospital é capaz de realizar mais cirurgias de média e alta complexidade localmente, ajudando a alcançar o objetivo médico de tratar doenças graves dentro do condado e reduzindo a necessidade de os pacientes viajarem para hospitais urbanos distantes para tratamento cirúrgico. Além dos benefícios clínicos diretos, o complexo cirúrgico atualizado também melhora as condições do hospital para ensino clínico e intercâmbios acadêmicos, apoiando o treinamento de jovens cirurgiões e o desenvolvimento contínuo das especialidades.&lt;/div&gt;&#xA;&lt;h2 class=&#34;heading-2 ace-line old-record-id-G074fq4W7dfsJZcPflbcPj6xnGr&#34;&gt;6. Implementação do Projeto e Garantia de Qualidade&lt;/h2&gt;&#xA;&lt;div class=&#34;ace-line ace-line old-record-id-VbqKfASrvdZFtdcXBCJcsaPdnSg&#34;&gt;Durante a execução do projeto, a equipe de construção cooperou estreitamente com a administração do hospital, cirurgiões clínicos e especialistas em controle de infecções. Várias rodadas de comunicação técnica foram realizadas para otimizar o layout das salas, a direção de abertura das portas, os parâmetros de fluxo de ar e a configuração de gases medicinais de acordo com o fluxo de trabalho cirúrgico real. Após a instalação, foram realizados testes de aceitação abrangentes, incluindo limpeza do ar, diferencial de pressão, ruído, temperatura e umidade, e inspeção de estanqueidade das portas, para verificar se todos os indicadores atendem plenamente aos padrões de engenharia de saúde.&lt;/div&gt;&#xA;&lt;h2 class=&#34;heading-2 ace-line old-record-id-Papif2uyQd2HMHc1sBRc9eEOnNg&#34;&gt;7. Conclusão&lt;/h2&gt;&#xA;&lt;div class=&#34;ace-line ace-line old-record-id-Rpi4fH0LydyivecFjtccNK4Fnag&#34;&gt;Em resumo, o Projeto de Portas Médicas e Salas Cirúrgicas Modulares Limpas do Hospital Popular de Boluo, iniciado em agosto de 2023, é uma atualização marco da infraestrutura de saúde para o Condado de Boluo. Combina tecnologia modular de sala limpa consolidada e sistemas de portas médicas profissionais para melhorar a segurança cirúrgica e o nível de prevenção de infecções do principal hospital terciário do condado. O complexo cirúrgico concluído atenderá os residentes locais por décadas, promovendo continuamente o desenvolvimento de alta qualidade dos serviços médicos regionais.&lt;/div&gt;</description>
			</item>
			<item>
				<title>obrigado</title>
				<link>https://pengchi.net/pt/thank-you/</link>
				<pubDate>Tue, 22 Sep 2026 08:55:56 +0000</pubDate>
				<guid>https://pengchi.net/pt/thank-you/</guid>
				<description>&lt;h1&gt;Obrigado pela sua mensagem.&lt;/h1&gt;&#xA;Responderemos o mais breve possível.&#xA;&lt;p&gt;Sinta-se à vontade para nos contatar por e-mail &lt;a href=&#34;mailto:pengchi@pengchihealth.com&#34;&gt;&lt;a href=&#34;mailto:pengchi@pengchihealth.com&#34;&gt;pengchi@pengchihealth.com&lt;/a&gt;&lt;/a&gt; ou celular +86-18025283503.&lt;/p&gt;</description>
			</item>
			<item>
				<title>projeto de demonstração 1</title>
				<link>https://pengchi.net/pt/projects/demo-project-1/</link>
				<pubDate>Tue, 22 Sep 2026 07:22:18 +0000</pubDate>
				<guid>https://pengchi.net/pt/projects/demo-project-1/</guid>
				<description>&lt;p&gt;Projeto de demonstração 1&lt;/p&gt;</description>
			</item>
			<item>
				<title>Projeto de Sala de Operações na Cidade de Ho Chi Minh, Vietnã</title>
				<link>https://pengchi.net/pt/projects/operating-room-project-in-ho-chi-minh-city-vietnam/</link>
				<pubDate>Tue, 22 Sep 2026 07:22:18 +0000</pubDate>
				<guid>https://pengchi.net/pt/projects/operating-room-project-in-ho-chi-minh-city-vietnam/</guid>
				<description>&lt;h1&gt;Projeto de Sala de Operações na Cidade de Ho Chi Minh, Vietnã&lt;/h1&gt;&#xA;&lt;h2&gt;Soluções modernas para salas de operação hospitalar da Pengchi&lt;/h2&gt;&#xA;A Pengchi Intelligent tem o compromisso de fornecer portas médicas, soluções modulares para salas de operação, móveis hospitalares e equipamentos para salas limpas a instalações de saúde em todo o mundo. Nosso projeto de sala de operações em um hospital na Cidade de Ho Chi Minh, Vietnã, demonstra nossa capacidade de apoiar ambientes cirúrgicos modernos com sistemas de parede integrados, armazenamento médico e layouts funcionais de equipamentos.&#xA;&lt;p&gt;Projetado para atender aos requisitos práticos de uma sala de operações hospitalar contemporânea, o projeto combina um interior limpo e coordenado com equipamentos cirúrgicos essenciais e infraestrutura médica embutida.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Mostra de fábrica</title>
				<link>https://pengchi.net/pt/factory-show/</link>
				<pubDate>Tue, 22 Sep 2026 06:41:23 +0000</pubDate>
				<guid>https://pengchi.net/pt/factory-show/</guid>
				<description>&lt;style id=&#34;pfvr-styles&#34;&gt;/**&#xA;* Estilos de front-end para os visualizadores do PlayForge VR.&#xA;*&#xA;* O visualizador é uma sobreposição escura, estilo vidro, sobre o canvas do A-Frame.&#xA;* A sobreposição em si é click-through; os elementos interativos da interface voltam&#xA;* a receber eventos via pointer-events em .pfvr-ui / button.&#xA;*/&#xA;.pfvr-viewer {&#xA;position: relative;&#xA;width: 100%;&#xA;height: var(--pfvr-height, 100vh);&#xA;background: #05070a;&#xA;border-radius: 10px;&#xA;overflow: hidden;&#xA;outline: none;&#xA;font-family: -apple-system, BlinkMacSystemFont, &#34;Segoe UI&#34;, Roboto,&#xA;&#34;PingFang SC&#34;, &#34;Hiragino Sans GB&#34;, &#34;Microsoft YaHei&#34;, sans-serif;&#xA;color: #fff;&#xA;}&#xA;.pfvr-viewer:focus-visible {&#xA;box-shadow: 0 0 0 3px rgba(66, 165, 245, 0.55);&#xA;}&#xA;/* O A-Frame preenche o contêiner (o modo embedded remove sua altura mínima padrão). */&#xA;.pfvr-viewer .a-embedded,&#xA;.pfvr-viewer a-scene {&#xA;position: absolute;&#xA;inset: 0;&#xA;width: 100% !important;&#xA;height: 100% !important;&#xA;min-height: 0 !important;&#xA;}&#xA;/* Sobreposição: click-through por padrão para que arrastar permita olhar ao redor. */&#xA;.pfvr-overlay {&#xA;position: absolute;&#xA;inset: 0;&#xA;z-index: 10;&#xA;pointer-events: none;&#xA;}&#xA;.pfvr-ui,&#xA;.pfvr-overlay button,&#xA;.pfvr-overlay select {&#xA;pointer-events: auto;&#xA;}&#xA;/* ---------- Barra superior ---------- */&#xA;.pfvr-topbar {&#xA;position: absolute;&#xA;top: 0;&#xA;left: 0;&#xA;right: 0;&#xA;display: flex;&#xA;align-items: center;&#xA;gap: 10px;&#xA;padding: 10px 14px;&#xA;background: linear-gradient(to bottom, rgba(0, 0, 0, 0.55), rgba(0, 0, 0, 0));&#xA;}&#xA;.pfvr-select {&#xA;flex: 1;&#xA;min-width: 0;&#xA;max-width: 360px;&#xA;padding: 7px 10px;&#xA;font-size: 13px;&#xA;color: #fff;&#xA;background: rgba(20, 26, 34, 0.72);&#xA;border: 1px solid rgba(255, 255, 255, 0.18);&#xA;border-radius: 8px;&#xA;cursor: pointer;&#xA;appearance: none;&#xA;-webkit-appearance: none;&#xA;background-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; width=&#39;12&#39; height=&#39;12&#39; viewBox=&#39;0 0 24 24&#39; fill=&#39;%23ffffff&#39;%3E%3Cpath d=&#39;M7 10l5 5 5-5z&#39;/%3E%3C/svg%3E&#34;);&#xA;background-repeat: no-repeat;&#xA;background-position: right 10px center;&#xA;padding-right: 30px;&#xA;}&#xA;.pfvr-select option {&#xA;color: #111;&#xA;}&#xA;.pfvr-top-actions {&#xA;margin-left: auto;&#xA;display: flex;&#xA;gap: 8px;&#xA;}&#xA;/* ---------- Botões ---------- */&#xA;.pfvr-btn {&#xA;display: inline-flex;&#xA;align-items: center;&#xA;justify-content: center;&#xA;width: 38px;&#xA;height: 38px;&#xA;padding: 0;&#xA;border: 1px solid rgba(255, 255, 255, 0.2);&#xA;border-radius: 50%;&#xA;background: rgba(20, 26, 34, 0.66);&#xA;color: #fff;&#xA;cursor: pointer;&#xA;backdrop-filter: blur(6px);&#xA;-webkit-backdrop-filter: blur(6px);&#xA;transition: background 0.15s ease, transform 0.15s ease;&#xA;}&#xA;.pfvr-btn:hover {&#xA;background: rgba(48, 60, 75, 0.9);&#xA;}&#xA;.pfvr-btn:active {&#xA;transform: scale(0.94);&#xA;}&#xA;.pfvr-nav {&#xA;position: absolute;&#xA;top: 50%;&#xA;transform: translateY(-50%);&#xA;z-index: 12;&#xA;}&#xA;.pfvr-nav:active {&#xA;transform: translateY(-50%) scale(0.94);&#xA;}&#xA;.pfvr-nav-prev { left: 14px; }&#xA;.pfvr-nav-next { right: 14px; }&#xA;/* ---------- Ícones (máscara para que herdem currentColor) ---------- */&#xA;.pfvr-icon {&#xA;width: 20px;&#xA;height: 20px;&#xA;display: inline-block;&#xA;background-color: currentColor;&#xA;-webkit-mask-repeat: no-repeat;&#xA;mask-repeat: no-repeat;&#xA;-webkit-mask-position: center;&#xA;mask-position: center;&#xA;-webkit-mask-size: contain;&#xA;mask-size: contain;&#xA;}&#xA;.pfvr-icon-prev {&#xA;-webkit-mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M15.4 7.4 14 6l-6 6 6 6 1.4-1.4L10.8 12z&#39;/%3E%3C/svg%3E&#34;);&#xA;mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M15.4 7.4 14 6l-6 6 6 6 1.4-1.4L10.8 12z&#39;/%3E%3C/svg%3E&#34;);&#xA;}&#xA;.pfvr-icon-next {&#xA;-webkit-mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M8.6 7.4 10 6l6 6-6 6-1.4-1.4L13.2 12z&#39;/%3E%3C/svg%3E&#34;);&#xA;mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M8.6 7.4 10 6l6 6-6 6-1.4-1.4L13.2 12z&#39;/%3E%3C/svg%3E&#34;);&#xA;}&#xA;.pfvr-icon-fs {&#xA;width: 18px;&#xA;height: 18px;&#xA;-webkit-mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M7 14H5v5h5v-2H7v-3zm-2-4h2V7h3V5H5v5zm12 7h-3v2h5v-5h-2v3zM14 5v2h3v3h2V5h-5z&#39;/%3E%3C/svg%3E&#34;);&#xA;mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M7 14H5v5h5v-2H7v-3zm-2-4h2V7h3V5H5v5zm12 7h-3v2h5v-5h-2v3zM14 5v2h3v3h2V5h-5z&#39;/%3E%3C/svg%3E&#34;);&#xA;}&#xA;.pfvr-icon-auto {&#xA;width: 19px;&#xA;height: 19px;&#xA;-webkit-mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M17.65 6.35A8 8 0 1 0 19.73 14h-2.08A6 6 0 1 1 12 6c1.66 0 3.14.69 4.22 1.78L13 11h7V4z&#39;/%3E%3C/svg%3E&#34;);&#xA;mask-image: url(&#34;data:image/svg+xml,%3Csvg xmlns=&#39;http://www.w3.org/2000/svg&#39; viewBox=&#39;0 0 24 24&#39;%3E%3Cpath d=&#39;M17.65 6.35A8 8 0 1 0 19.73 14h-2.08A6 6 0 1 1 12 6c1.66 0 3.14.69 4.22 1.78L13 11h7V4z&#39;/%3E%3C/svg%3E&#34;);&#xA;}&#xA;.pfvr-auto-btn.is-off {&#xA;opacity: 0.45;&#xA;}&#xA;.pfvr-fs-btn.is-fullscreen .pfvr-icon-fs {&#xA;opacity: 0.7;&#xA;}&#xA;/* ---------- Painel de informações ---------- */&#xA;.pfvr-info {&#xA;position: absolute;&#xA;left: 14px;&#xA;bottom: 116px;&#xA;max-width: min(440px, calc(100% - 28px));&#xA;padding: 12px 16px;&#xA;background: rgba(10, 14, 20, 0.62);&#xA;border: 1px solid rgba(255, 255, 255, 0.1);&#xA;border-radius: 10px;&#xA;backdrop-filter: blur(8px);&#xA;-webkit-backdrop-filter: blur(8px);&#xA;}&#xA;.pfvr-info[hidden] {&#xA;display: none;&#xA;}&#xA;.pfvr-scene-title {&#xA;font-size: 16px;&#xA;font-weight: 700;&#xA;line-height: 1.35;&#xA;margin-bottom: 4px;&#xA;}&#xA;.pfvr-scene-desc {&#xA;font-size: 13px;&#xA;line-height: 1.6;&#xA;color: rgba(255, 255, 255, 0.85);&#xA;word-break: break-word;&#xA;}&#xA;.pfvr-scene-desc p {&#xA;margin: 0 0 6px;&#xA;}&#xA;.pfvr-scene-desc p:last-child {&#xA;margin-bottom: 0;&#xA;}&#xA;/* ---------- Faixa de miniaturas ---------- */&#xA;.pfvr-thumbs {&#xA;position: absolute;&#xA;left: 0;&#xA;right: 0;&#xA;bottom: 0;&#xA;display: flex;&#xA;gap: 10px;&#xA;padding: 10px 76px 12px 14px; /* o espaço à direita reserva lugar para o botão de VR do A-Frame */&#xA;overflow-x: auto;&#xA;scrollbar-width: thin;&#xA;scrollbar-color: rgba(255, 255, 255, 0.35) transparent;&#xA;background: linear-gradient(to top, rgba(0, 0, 0, 0.55), rgba(0, 0, 0, 0));&#xA;}&#xA;.pfvr-thumbs::-webkit-scrollbar {&#xA;height: 6px;&#xA;}&#xA;.pfvr-thumbs::-webkit-scrollbar-thumb {&#xA;background: rgba(255, 255, 255, 0.3);&#xA;border-radius: 3px;&#xA;}&#xA;.pfvr-thumb {&#xA;flex: 0 0 auto;&#xA;width: 108px;&#xA;padding: 0;&#xA;border: 2px solid transparent;&#xA;border-radius: 8px;&#xA;overflow: hidden;&#xA;background: rgba(255, 255, 255, 0.08);&#xA;cursor: pointer;&#xA;text-align: left;&#xA;transition: border-color 0.15s ease, transform 0.15s ease;&#xA;}&#xA;.pfvr-thumb:hover {&#xA;transform: translateY(-2px);&#xA;}&#xA;.pfvr-thumb img {&#xA;display: block;&#xA;width: 108px;&#xA;height: 64px;&#xA;object-fit: cover;&#xA;}&#xA;.pfvr-thumb-label {&#xA;display: block;&#xA;padding: 4px 6px;&#xA;font-size: 11px;&#xA;line-height: 1.3;&#xA;color: rgba(255, 255, 255, 0.88);&#xA;white-space: nowrap;&#xA;overflow: hidden;&#xA;text-overflow: ellipsis;&#xA;}&#xA;.pfvr-thumb.is-active {&#xA;border-color: #42a5f5;&#xA;box-shadow: 0 0 0 1px rgba(66, 165, 245, 0.6);&#xA;}&#xA;.pfvr-thumb.is-active .pfvr-thumb-label {&#xA;color: #90caf9;&#xA;}&#xA;/* ---------- Indicador de carregamento ---------- */&#xA;.pfvr-loader {&#xA;position: absolute;&#xA;inset: 0;&#xA;display: flex;&#xA;align-items: center;&#xA;justify-content: center;&#xA;pointer-events: none;&#xA;}&#xA;.pfvr-spinner {&#xA;width: 42px;&#xA;height: 42px;&#xA;border: 3px solid rgba(255, 255, 255, 0.2);&#xA;border-top-color: #42a5f5;&#xA;border-radius: 50%;&#xA;animation: pfvr-spin 0.9s linear infinite;&#xA;}&#xA;@keyframes pfvr-spin {&#xA;to {&#xA;transform: rotate(360deg);&#xA;}&#xA;}&#xA;.pfvr-viewer:not(.pfvr-loading) .pfvr-loader {&#xA;display: none;&#xA;}&#xA;/* ---------- Tela cheia ---------- */&#xA;.pfvr-viewer:fullscreen,&#xA;.pfvr-viewer:-webkit-full-screen {&#xA;height: 100%;&#xA;border-radius: 0;&#xA;}&#xA;.pfvr-viewer:fullscreen .pfvr-info {&#xA;bottom: 120px;&#xA;}&#xA;/* ---------- Telas pequenas ---------- */&#xA;@media (max-width: 600px) {&#xA;.pfvr-viewer {&#xA;border-radius: 6px;&#xA;}&#xA;.pfvr-info {&#xA;left: 8px;&#xA;right: 8px;&#xA;bottom: 108px;&#xA;max-width: none;&#xA;padding: 10px 12px;&#xA;}&#xA;.pfvr-scene-title {&#xA;font-size: 14px;&#xA;}&#xA;.pfvr-scene-desc {&#xA;font-size: 12px;&#xA;}&#xA;.pfvr-nav {&#xA;width: 34px;&#xA;height: 34px;&#xA;}&#xA;.pfvr-nav-prev { left: 6px; }&#xA;.pfvr-nav-next { right: 6px; }&#xA;.pfvr-thumb {&#xA;width: 92px;&#xA;}&#xA;.pfvr-thumb img {&#xA;width: 92px;&#xA;height: 56px;&#xA;}&#xA;.pfvr-topbar {&#xA;padding: 8px 10px;&#xA;}&#xA;}&#xA;/* Aviso voltado ao editor para shortcodes mal configurados. */&#xA;.pfvr-notice {&#xA;padding: 12px 16px;&#xA;background: #fcf0f1;&#xA;border-left: 4px solid #d63638;&#xA;color: #3c434a;&#xA;}&#xA;&lt;/style&gt;&#xA;&lt;script src=&#34;https://pengchi.net/wp-content/plugins/playforge-vr/assets/vendor/aframe.min.js&#34;&gt;&lt;/script&gt;&#xA;&lt;div&#xA;id=&#34;pfvr-viewer-494-2&#34;&#xA;class=&#34;pfvr-viewer pfvr-loading&#34;&#xA;style=&#34;--pfvr-height: 100vh;&#34;&#xA;data-scene=&#34;0&#34;&#xA;data-autoplay=&#34;1&#34;&#xA;data-preload=&#34;all&#34;&#xA;tabindex=&#34;0&#34;&#xA;&gt;&#xA;&lt;a-scene&#xA;embedded&#xA;loading-screen=&#34;enabled: false&#34;&#xA;vr-mode-ui=&#34;enabled: true&#34;&#xA;renderer=&#34;colorManagement: true; antialias: true&#34;&#xA;&gt;&#xA;&lt;a-assets timeout=&#34;30000&#34;&gt;&#xA;&lt;img&#xA;id=&#34;pfvr-a-0&#34;&#xA;src=&#34;https://pengchi.net/wp-content/uploads/2026/09/Factory-Aerial-View-scaled.jpg&#34;&#xA;alt=&#34;&#34;&#xA;&gt;&#xA;&lt;img&#xA;id=&#34;pfvr-a-1&#34;&#xA;src=&#34;https://pengchi.net/wp-content/uploads/2026/09/Sheet-Metal-Processing-Workshop-scaled.jpg&#34;&#xA;alt=&#34;&#34;&#xA;&gt;&#xA;&lt;img&#xA;id=&#34;pfvr-a-2&#34;&#xA;src=&#34;https://pengchi.net/wp-content/uploads/2026/09/Panel-Board-Production-Workshop-scaled.jpg&#34;&#xA;alt=&#34;&#34;&#xA;&gt;&#xA;&lt;img&#xA;id=&#34;pfvr-a-3&#34;&#xA;src=&#34;https://pengchi.net/wp-content/uploads/2026/09/Medical-Cabinet-Assembly-Workshop-scaled.jpg&#34;&#xA;alt=&#34;&#34;&#xA;&gt;&#xA;&lt;img&#xA;id=&#34;pfvr-a-4&#34;&#xA;src=&#34;https://pengchi.net/wp-content/uploads/2026/09/Medical-Equipment-Showroom-scaled.jpg&#34;&#xA;alt=&#34;&#34;&#xA;&gt;&#xA;&lt;img&#xA;id=&#34;pfvr-a-5&#34;&#xA;src=&#34;https://pengchi.net/wp-content/uploads/2026/09/Open-Office-Area-scaled.jpg&#34;&#xA;alt=&#34;&#34;&#xA;&gt;&#xA;&lt;/a-assets&gt;&#xA;&lt;a-sky data-role=&#34;sky&#34; src=&#34;#pfvr-a-0&#34;&gt;&lt;/a-sky&gt;&#xA;&lt;a-entity data-role=&#34;rig&#34; pfvr-auto=&#34;speed: 0.06; enabled: true&#34;&gt;&#xA;&lt;a-entity camera look-controls=&#34;reverseMouseDrag: true&#34; fov=&#34;80&#34;&gt;&lt;/a-entity&gt;&#xA;&lt;/a-entity&gt;&#xA;&lt;/a-scene&gt;&#xA;&lt;div class=&#34;pfvr-overlay&#34;&gt;&#xA;&lt;div class=&#34;pfvr-topbar pfvr-ui&#34;&gt;&#xA;&lt;select class=&#34;pfvr-select&#34; aria-label=&#34;Alternar cena por título&#34;&gt;&lt;/select&gt;&#xA;&lt;div class=&#34;pfvr-top-actions&#34;&gt;&#xA;&lt;button type=&#34;button&#34; class=&#34;pfvr-btn pfvr-auto-btn&#34; aria-label=&#34;Alternar rotação automática&#34; title=&#34;Rotação automática&#34;&gt;&#xA;&lt;span class=&#34;pfvr-icon pfvr-icon-auto&#34; aria-hidden=&#34;true&#34;&gt;&lt;/span&gt;&#xA;&lt;/button&gt;&#xA;&lt;button type=&#34;button&#34; class=&#34;pfvr-btn pfvr-fs-btn&#34; aria-label=&#34;Tela cheia&#34; title=&#34;Tela cheia&#34;&gt;&#xA;&lt;span class=&#34;pfvr-icon pfvr-icon-fs&#34; aria-hidden=&#34;true&#34;&gt;&lt;/span&gt;&#xA;&lt;/button&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;pfvr-info&#34;&gt;&#xA;&lt;div class=&#34;pfvr-scene-title&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;pfvr-scene-desc&#34;&gt;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;button type=&#34;button&#34; class=&#34;pfvr-btn pfvr-nav pfvr-nav-prev pfvr-ui&#34; aria-label=&#34;Anterior&#34;&gt;&#xA;&lt;span class=&#34;pfvr-icon pfvr-icon-prev&#34; aria-hidden=&#34;true&#34;&gt;&lt;/span&gt;&#xA;&lt;/button&gt;&#xA;&lt;button type=&#34;button&#34; class=&#34;pfvr-btn pfvr-nav pfvr-nav-next pfvr-ui&#34; aria-label=&#34;Próximo&#34;&gt;&#xA;&lt;span class=&#34;pfvr-icon pfvr-icon-next&#34; aria-hidden=&#34;true&#34;&gt;&lt;/span&gt;&#xA;&lt;/button&gt;&#xA;&lt;div class=&#34;pfvr-thumbs pfvr-ui&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;pfvr-loader&#34; aria-hidden=&#34;true&#34;&gt;&#xA;&lt;span class=&#34;pfvr-spinner&#34;&gt;&lt;/span&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;script type=&#34;application/json&#34; class=&#34;pfvr-data&#34;&gt;[{&#34;id&#34;:&#34;scene-1790058861688-1&#34;,&#34;title&#34;:&#34;Vista Aérea da Fábrica&#34;,&#34;description&#34;:&#34;Parque Industrial de Tecnologia Inteligente Pengchi&#34;,&#34;image&#34;:&#34;/wp-content/uploads/2026/09/Factory-Aerial-View-scaled.jpg&#34;,&#34;thumb&#34;:&#34;/wp-content/uploads/2026/09/cropped-Factory-Aerial-View-scaled-1.jpg&#34;},{&#34;id&#34;:&#34;scene-1790058915736-2&#34;,&#34;title&#34;:&#34;Oficina 1&#34;,&#34;description&#34;:&#34;Piso 1 , oficina de corte a laser &#34;,&#34;image&#34;:&#34;/wp-content/uploads/2026/09/Sheet-Metal-Processing-Workshop-scaled.jpg&#34;,&#34;thumb&#34;:&#34;/wp-content/uploads/2026/09/cropped-Sheet-Metal-Processing-Workshop-scaled-1.jpg&#34;},{&#34;id&#34;:&#34;scene-1790058933968-3&#34;,&#34;title&#34;:&#34;Oficina&#34;,&#34;description&#34;:&#34;Piso 3, oficina de portas hospitalares&#34;,&#34;image&#34;:&#34;/wp-content/uploads/2026/09/Panel-Board-Production-Workshop-scaled.jpg&#34;,&#34;thumb&#34;:&#34;/wp-content/uploads/2026/09/cropped-Panel-Board-Production-Workshop-scaled-1.jpg&#34;},{&#34;id&#34;:&#34;scene-1790059002625-4&#34;,&#34;title&#34;:&#34;Oficina&#34;,&#34;description&#34;:&#34;Piso 4, oficina de capelas de exaustão&#34;,&#34;image&#34;:&#34;/wp-content/uploads/2026/09/Medical-Cabinet-Assembly-Workshop-scaled.jpg&#34;,&#34;thumb&#34;:&#34;/wp-content/uploads/2026/09/cropped-Medical-Cabinet-Assembly-Workshop-scaled-1.jpg&#34;},{&#34;id&#34;:&#34;scene-1790059172719-5&#34;,&#34;title&#34;:&#34;Showroom&#34;,&#34;description&#34;:&#34;Piso 9, showroom de móveis hospitalares&#34;,&#34;image&#34;:&#34;/wp-content/uploads/2026/09/Medical-Equipment-Showroom-scaled.jpg&#34;,&#34;thumb&#34;:&#34;/wp-content/uploads/2026/09/cropped-Medical-Equipment-Showroom-scaled-1.jpg&#34;},{&#34;id&#34;:&#34;scene-1790059199810-6&#34;,&#34;title&#34;:&#34;Escritório Pengchi&#34;,&#34;description&#34;:&#34;Piso 9 , saguão do escritório&#34;,&#34;image&#34;:&#34;/wp-content/uploads/2026/09/Open-Office-Area-scaled.jpg&#34;,&#34;thumb&#34;:&#34;/wp-content/uploads/2026/09/cropped-Open-Office-Area-scaled-1.jpg&#34;}]&lt;/script&gt;&#xA;&lt;/div&gt;&#xA;&lt;script&gt;/**&#xA;* Lógica de front-end para os visualizadores PlayForge VR.&#xA;*&#xA;* Lê o JSON de cenas renderizado pelo shortcode, constrói o select de títulos,&#xA;* a faixa de miniaturas e o painel de informações, e troca a textura do &lt;a-sky&gt; ao mudar.&#xA;*/&#xA;( function () {&#xA;&#39;use strict&#39;;&#xA;/**&#xA;* Componente A-Frame: rotação lenta de guinada do conjunto da câmera.&#xA;*&#xA;* Pausa enquanto o visitante arrasta/olha ao redor e retoma após um intervalo&#xA;* de inatividade, para nunca conflitar com os controles do visualizador.&#xA;*/&#xA;function registerAutoComponent() {&#xA;if ( ! window.AFRAME || window.AFRAME.components[ &#39;pfvr-auto&#39; ] ) {&#xA;return;&#xA;}&#xA;window.AFRAME.registerComponent( &#39;pfvr-auto&#39;, {&#xA;schema: {&#xA;speed: { default: 0.06 }, // radianos por segundo.&#xA;enabled: { default: true }&#xA;},&#xA;init: function () {&#xA;this.userPaused = false;&#xA;this.tempPaused = false;&#xA;this.resumeTimer = null;&#xA;var self = this;&#xA;var pauseTemporarily = function () {&#xA;self.tempPaused = true;&#xA;window.clearTimeout( self.resumeTimer );&#xA;self.resumeTimer = window.setTimeout( function () {&#xA;self.tempPaused = false;&#xA;}, 4000 );&#xA;};&#xA;// O canvas recebe os eventos de ponteiro/toque que o look-controls utiliza.&#xA;var bind = function () {&#xA;var canvas = self.el.sceneEl.canvas;&#xA;if ( ! canvas ) {&#xA;return;&#xA;}&#xA;canvas.addEventListener( &#39;pointerdown&#39;, pauseTemporarily );&#xA;canvas.addEventListener( &#39;wheel&#39;, pauseTemporarily, { passive: true } );&#xA;canvas.addEventListener( &#39;touchstart&#39;, pauseTemporarily, { passive: true } );&#xA;};&#xA;if ( this.el.sceneEl.canvas ) {&#xA;bind();&#xA;} else {&#xA;this.el.sceneEl.addEventListener( &#39;rendertargetchanged&#39;, bind );&#xA;window.setTimeout( bind, 500 );&#xA;}&#xA;},&#xA;setEnabled: function ( enabled ) {&#xA;this.userPaused = ! enabled;&#xA;},&#xA;tick: function ( _time, delta ) {&#xA;if (&#xA;! this.data.enabled ||&#xA;this.userPaused ||&#xA;this.tempPaused ||&#xA;document.hidden&#xA;) {&#xA;return;&#xA;}&#xA;this.el.object3D.rotation.y += ( delta / 1000 ) * this.data.speed;&#xA;}&#xA;} );&#xA;}&#xA;/** Cria um span de ícone com uma classe (o conteúdo vem do CSS). */&#xA;function icon( className ) {&#xA;var span = document.createElement( &#39;span&#39; );&#xA;span.className = &#39;pfvr-icon &#39; + className;&#xA;span.setAttribute( &#39;aria-hidden&#39;, &#39;true&#39; );&#xA;return span;&#xA;}&#xA;/**&#xA;* Inicializa um elemento visualizador.&#xA;*&#xA;* @param {HTMLElement} viewer Elemento raiz .pfvr-viewer.&#xA;*/&#xA;function initViewer( viewer ) {&#xA;var dataEl = viewer.querySelector( &#39;.pfvr-data&#39; );&#xA;var scenes;&#xA;try {&#xA;scenes = JSON.parse( dataEl.textContent || &#39;{}&#39; );&#xA;} catch ( e ) {&#xA;scenes = [];&#xA;}&#xA;if ( ! Array.isArray( scenes ) || ! scenes.length ) {&#xA;return;&#xA;}&#xA;var sky = viewer.querySelector( &#39;[data-role=&#34;sky&#34;]&#39; );&#xA;var rig = viewer.querySelector( &#39;[data-role=&#34;rig&#34;]&#39; );&#xA;var select = viewer.querySelector( &#39;.pfvr-select&#39; );&#xA;var thumbs = viewer.querySelector( &#39;.pfvr-thumbs&#39; );&#xA;var infoTitle = viewer.querySelector( &#39;.pfvr-scene-title&#39; );&#xA;var infoDesc = viewer.querySelector( &#39;.pfvr-scene-desc&#39; );&#xA;var infoBox = viewer.querySelector( &#39;.pfvr-info&#39; );&#xA;var loader = viewer.querySelector( &#39;.pfvr-loader&#39; );&#xA;var autoBtn = viewer.querySelector( &#39;.pfvr-auto-btn&#39; );&#xA;var fsBtn = viewer.querySelector( &#39;.pfvr-fs-btn&#39; );&#xA;var prevBtn = viewer.querySelector( &#39;.pfvr-nav-prev&#39; );&#xA;var nextBtn = viewer.querySelector( &#39;.pfvr-nav-next&#39; );&#xA;var current = Math.min(&#xA;parseInt( viewer.getAttribute( &#39;data-scene&#39; ), 10 ) || 0,&#xA;scenes.length - 1&#xA;);&#xA;var autoEnabled = viewer.getAttribute( &#39;data-autoplay&#39; ) === &#39;1&#39;;&#xA;var preloadAll = viewer.getAttribute( &#39;data-preload&#39; ) === &#39;all&#39;;&#xA;var assetsBox = viewer.querySelector( &#39;a-assets&#39; );&#xA;var loadFallbackTimer = null;&#xA;// Constrói o &lt;select&gt; de títulos.&#xA;scenes.forEach( function ( scene, i ) {&#xA;var option = document.createElement( &#39;option&#39; );&#xA;option.value = String( i );&#xA;option.textContent = scene.title || &#39;Cena &#39; + ( i + 1 );&#xA;select.appendChild( option );&#xA;} );&#xA;// Constrói a faixa de miniaturas.&#xA;var thumbButtons = [];&#xA;scenes.forEach( function ( scene, i ) {&#xA;var button = document.createElement( &#39;button&#39; );&#xA;button.type = &#39;button&#39;;&#xA;button.className = &#39;pfvr-thumb&#39;;&#xA;button.setAttribute( &#39;aria-label&#39;, scene.title || &#39;Cena &#39; + ( i + 1 ) );&#xA;var img = document.createElement( &#39;img&#39; );&#xA;img.src = scene.thumb || &#39;&#39;;&#xA;img.alt = &#39;&#39;;&#xA;img.addEventListener( &#39;error&#39;, function () {&#xA;img.style.display = &#39;none&#39;;&#xA;} );&#xA;var label = document.createElement( &#39;span&#39; );&#xA;label.className = &#39;pfvr-thumb-label&#39;;&#xA;label.textContent = scene.title || &#39;Cena &#39; + ( i + 1 );&#xA;button.appendChild( img );&#xA;button.appendChild( label );&#xA;button.addEventListener( &#39;click&#39;, function () {&#xA;goTo( i );&#xA;} );&#xA;thumbs.appendChild( button );&#xA;thumbButtons.push( button );&#xA;} );&#xA;/**&#xA;* Garante que a cena i exista como um &lt;img&gt; dentro de &lt;a-assets&gt;, criando-a&#xA;* se necessário. O A-Frame então a carrega e armazena em cache a textura da GPU,&#xA;* de modo que apontar o céu para ela é instantâneo após o carregamento.&#xA;*&#xA;* @param {number} i Índice da cena.&#xA;*/&#xA;function ensureAsset( i ) {&#xA;if ( ! assetsBox || ! scenes[ i ] ) {&#xA;return;&#xA;}&#xA;var id = &#39;pfvr-a-&#39; + i;&#xA;if ( document.getElementById( id ) ) {&#xA;return;&#xA;}&#xA;var img = document.createElement( &#39;img&#39; );&#xA;img.id = id;&#xA;img.alt = &#39;&#39;;&#xA;img.src = scenes[ i ].image;&#xA;assetsBox.appendChild( img );&#xA;}&#xA;/** Pré-carrega uma cena como um asset do A-Frame (aquece a rede + o cache da GPU). */&#xA;function preload( i ) {&#xA;ensureAsset( i );&#xA;}&#xA;/** Oculta o spinner de carregamento assim que a nova textura está no céu. */&#xA;function hideLoader() {&#xA;window.clearTimeout( loadFallbackTimer );&#xA;viewer.classList.remove( &#39;pfvr-loading&#39; );&#xA;if ( loader ) {&#xA;loader.style.display = &#39;none&#39;;&#xA;}&#xA;}&#xA;/**&#xA;* Muda para uma cena pelo índice.&#xA;*&#xA;* @param {number} i Índice de destino.&#xA;*/&#xA;function goTo( i ) {&#xA;if ( i === current || i &lt; 0 || i &gt;= scenes.length ) {&#xA;return;&#xA;}&#xA;current = i;&#xA;viewer.classList.add( &#39;pfvr-loading&#39; );&#xA;if ( loader ) {&#xA;loader.style.display = &#39;&#39;;&#xA;}&#xA;var settled = false;&#xA;var finish = function () {&#xA;if ( settled ) {&#xA;return;&#xA;}&#xA;settled = true;&#xA;hideLoader();&#xA;sky.removeEventListener( &#39;materialtextureloaded&#39;, finish );&#xA;sky.removeEventListener( &#39;materialtextureerror&#39;, finish );&#xA;};&#xA;// Rede de segurança: nunca deixa o spinner travado se nenhum evento for disparado.&#xA;window.clearTimeout( loadFallbackTimer );&#xA;loadFallbackTimer = window.setTimeout( finish, 9000 );&#xA;sky.addEventListener( &#39;materialtextureloaded&#39;, finish );&#xA;sky.addEventListener( &#39;materialtextureerror&#39;, finish );&#xA;// Garante que a imagem de destino esteja em &lt;a-assets&gt;, depois referencia-a&#xA;// por ID para que o cache de texturas do A-Frame seja reutilizado.&#xA;ensureAsset( i );&#xA;sky.setAttribute( &#39;src&#39;, &#39;#pfvr-a-&#39; + i );&#xA;// Quando a imagem de destino já terminou de carregar, o A-Frame pode&#xA;// resolver o material sincronicamente sem emitir um evento;&#xA;// nesse caso, oculta o spinner no próximo quadro.&#xA;var targetImg = document.getElementById( &#39;pfvr-a-&#39; + i );&#xA;if ( targetImg &amp;&amp; targetImg.complete &amp;&amp; targetImg.naturalWidth ) {&#xA;window.requestAnimationFrame( function () {&#xA;window.requestAnimationFrame( finish );&#xA;} );&#xA;}&#xA;updateUI();&#xA;preload( ( i + 1 ) % scenes.length );&#xA;preload( ( i - 1 + scenes.length ) % scenes.length );&#xA;}&#xA;/** Atualiza os estados ativos de título/descrição/select/miniatura. */&#xA;function updateUI() {&#xA;var scene = scenes[ current ];&#xA;select.value = String( current );&#xA;infoTitle.textContent = scene.title || &#39;&#39;;&#xA;if ( scene.description &amp;&amp; scene.description.trim() ) {&#xA;infoDesc.innerHTML = scene.description;&#xA;infoBox.hidden = false;&#xA;} else {&#xA;infoDesc.innerHTML = &#39;&#39;;&#xA;infoBox.hidden = ! scene.title;&#xA;}&#xA;thumbButtons.forEach( function ( button, i ) {&#xA;button.classList.toggle( &#39;is-active&#39;, i === current );&#xA;} );&#xA;// Mantém a miniatura ativa visível na faixa rolada.&#xA;var active = thumbButtons[ current ];&#xA;if ( active &amp;&amp; active.scrollIntoView ) {&#xA;active.scrollIntoView( { behavior: &#39;smooth&#39;, inline: &#39;center&#39;, block: &#39;nearest&#39; } );&#xA;}&#xA;}&#xA;// --- Eventos de UI ------------------------------------------------&#xA;select.addEventListener( &#39;change&#39;, function () {&#xA;goTo( parseInt( select.value, 10 ) );&#xA;} );&#xA;prevBtn.addEventListener( &#39;click&#39;, function () {&#xA;goTo( ( current - 1 + scenes.length ) % scenes.length );&#xA;} );&#xA;nextBtn.addEventListener( &#39;click&#39;, function () {&#xA;goTo( ( current + 1 ) % scenes.length );&#xA;} );&#xA;autoBtn.addEventListener( &#39;click&#39;, function () {&#xA;autoEnabled = ! autoEnabled;&#xA;setAutoButtonState();&#xA;if ( rig.components &amp;&amp; rig.components[ &#39;pfvr-auto&#39; ] ) {&#xA;rig.components[ &#39;pfvr-auto&#39; ].setEnabled( autoEnabled );&#xA;}&#xA;rig.setAttribute( &#39;pfvr-auto&#39;, &#39;enabled&#39;, autoEnabled ? &#39;true&#39; : &#39;false&#39; );&#xA;} );&#xA;function setAutoButtonState() {&#xA;autoBtn.classList.toggle( &#39;is-off&#39;, ! autoEnabled );&#xA;autoBtn.setAttribute( &#39;aria-pressed&#39;, autoEnabled ? &#39;true&#39; : &#39;false&#39; );&#xA;}&#xA;// Tela cheia.&#xA;fsBtn.addEventListener( &#39;click&#39;, function () {&#xA;if ( document.fullscreenElement ) {&#xA;document.exitFullscreen();&#xA;} else if ( viewer.requestFullscreen ) {&#xA;viewer.requestFullscreen();&#xA;} else if ( viewer.webkitRequestFullscreen ) {&#xA;viewer.webkitRequestFullscreen();&#xA;}&#xA;} );&#xA;document.addEventListener( &#39;fullscreenchange&#39;, function () {&#xA;fsBtn.classList.toggle( &#39;is-fullscreen&#39;, !! document.fullscreenElement );&#xA;} );&#xA;// Teclado: só atua quando este visualizador está em foco ou em ecrã inteiro.&#xA;viewer.addEventListener( &#39;keydown&#39;, function ( event ) {&#xA;if (&#xA;document.fullscreenElement !== viewer &amp;&amp;&#xA;! viewer.contains( document.activeElement )&#xA;) {&#xA;return;&#xA;}&#xA;if ( event.key === &#39;ArrowRight&#39; ) {&#xA;event.preventDefault();&#xA;goTo( ( current + 1 ) % scenes.length );&#xA;} else if ( event.key === &#39;ArrowLeft&#39; ) {&#xA;event.preventDefault();&#xA;goTo( ( current - 1 + scenes.length ) % scenes.length );&#xA;}&#xA;} );&#xA;// Galerias com uma única cena não precisam de elementos de navegação.&#xA;if ( scenes.length === 1 ) {&#xA;prevBtn.style.display = &#39;none&#39;;&#xA;nextBtn.style.display = &#39;none&#39;;&#xA;thumbs.style.display = &#39;none&#39;;&#xA;select.style.display = &#39;none&#39;;&#xA;}&#xA;// --- Estado inicial -------------------------------------------------&#xA;setAutoButtonState();&#xA;updateUI();&#xA;// O modo &#34;all&#34; já incluiu todas as imagens em &lt;a-assets&gt;; no modo &#34;adjacent&#34;&#xA;// pré-carrega ambos os vizinhos da cena inicial.&#xA;if ( ! preloadAll ) {&#xA;preload( ( current + 1 ) % scenes.length );&#xA;preload( ( current - 1 + scenes.length ) % scenes.length );&#xA;}&#xA;// Oculta o indicador de carregamento assim que a primeira textura for carregada.&#xA;var onInitialLoaded = function () {&#xA;hideLoader();&#xA;sky.removeEventListener( &#39;materialtextureloaded&#39;, onInitialLoaded );&#xA;sky.removeEventListener( &#39;materialtextureerror&#39;, onInitialError );&#xA;};&#xA;var onInitialError = function () {&#xA;hideLoader();&#xA;sky.removeEventListener( &#39;materialtextureloaded&#39;, onInitialLoaded );&#xA;sky.removeEventListener( &#39;materialtextureerror&#39;, onInitialError );&#xA;};&#xA;sky.addEventListener( &#39;materialtextureloaded&#39;, onInitialLoaded );&#xA;sky.addEventListener( &#39;materialtextureerror&#39;, onInitialError );&#xA;window.setTimeout( hideLoader, 9000 );&#xA;}&#xA;function boot() {&#xA;registerAutoComponent();&#xA;document.querySelectorAll( &#39;.pfvr-viewer&#39; ).forEach( initViewer );&#xA;}&#xA;if ( document.readyState === &#39;loading&#39; ) {&#xA;document.addEventListener( &#39;DOMContentLoaded&#39;, boot );&#xA;} else {&#xA;boot();&#xA;}&#xA;} )();&#xA;&lt;/script&gt;</description>
			</item>
			<item>
				<title>Mobiliário para sala de exames</title>
				<link>https://pengchi.net/pt/medical-furniture/examination-room-furniture/</link>
				<pubDate>Mon, 21 Sep 2026 08:58:04 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-furniture/examination-room-furniture/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;A sala de exames é o espaço onde os médicos realizam consultas e os pacientes recebem cuidados médicos.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;Com base nos princípios de segurança, relação médico-paciente e fluxos de trabalho digitais modernos, nossos designers criaram um ambiente clínico relaxado. Os móveis da clínica são cuidadosamente integrados ao design espacial geral para proporcionar aos pacientes um ambiente confortável, sereno e privado, ao mesmo tempo que priorizam a eficiência ergonômica e a facilidade de uso nas operações diárias.</description>
			</item>
			<item>
				<title>Cadeira de espera</title>
				<link>https://pengchi.net/pt/medical-furniture/waiting-chair/</link>
				<pubDate>Mon, 21 Sep 2026 08:58:03 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-furniture/waiting-chair/</guid>
				<description>&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;div&gt; &lt;div&gt; &lt;div&gt; &lt;div&gt; &lt;div&gt; &lt;div&gt; &lt;div&gt; &lt;div&gt; &lt;div&gt; &lt;div&gt; &lt;div&gt; &lt;div&gt; &lt;div dir=&#34;ltr&#34; theme-mode=&#34;light&#34;&gt; &lt;div&gt; &lt;p&gt; Superfície do assento: o assento e o encosto da cadeira de espera são feitos de PU auto-pele, mais durável e mais fácil de limpar do que o couro sintético tradicional. &lt;/p&gt; &lt;p&gt; Em comparação com o aço inoxidável tradicional, é menos frio ao toque e mais quente e acolhedor, o que o torna adequado ao design de hospitais modernos e centrados no paciente. &lt;/p&gt; &lt;p&gt; Estrutura da cadeira: estrutura de liga de alumínio de alta qualidade com ponteiras antiderrapantes. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Unidade de Enfermagem</title>
				<link>https://pengchi.net/pt/medical-cabinet/nursing-unit/</link>
				<pubDate>Mon, 21 Sep 2026 08:58:01 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-cabinet/nursing-unit/</guid>
				<description>&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Material de Base: Fabricado em painel multicamadas de madeira maciça ecológico de grau E1 que atende aos padrões internacionais E1, tratado com acabamentos especiais à prova de insetos e anticorrosivos, e com teor de umidade em conformidade com as normas nacionais. &lt;br/&gt; Acabamento Superficial: Acabado com painéis antibacterianos de superfície limpa. Utilizando tecnologia de íons de prata, esse acabamento oferece os seguintes benefícios: desempenho antimicrobiano duradouro, rápido e contínuo; proteção de amplo espectro contra uma ampla gama de microrganismos, incluindo bactérias, fungos e bolores; redução da contaminação cruzada; e prevenção da formação de odores e manchas. &lt;br/&gt; Material da Pedra: Utiliza pedra engenheirada de pó de alumínio Gordi, que proporciona juntas sem costura, mínima geração de poeira durante o polimento, alta densidade da pedra, excelente resistência a manchas e fácil limpeza. &lt;br/&gt; Ferragens: Equipado com dobradiça amortecedora DTC de alta qualidade, trilho deslizante silencioso de três seções, conectores premium e puxadores de liga de alumínio, entre outros; a abertura e o fechamento são silenciosos. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta de Correr Automática Hospitalar de Folha Única</title>
				<link>https://pengchi.net/pt/automatic-medical-sliding-door/medical-single-leaf-automatic-sliding-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:59 +0000</pubDate>
				<guid>https://pengchi.net/pt/automatic-medical-sliding-door/medical-single-leaf-automatic-sliding-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Portas de correr automáticas de folha única para uso médico são projetadas especificamente para ambientes de saúde e salas limpas. Elas contam com um mecanismo de abertura de correr unidirecional e são totalmente automatizadas por meio de sensores ou sistemas de controle, atendendo aos requisitos de limpeza, segurança e acesso sem barreiras.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 O material do núcleo pode ser favo de alumínio ou favo de papel; a superfície das chapas de aço recebe revestimento de tinta em pó antiestática, e as bordas da folha da porta são compostas por perfis de alumínio, com faixas de vedação instaladas em todo o perímetro.&#xA;&lt;p&gt;02 Mecanismo de suspensão da porta ajustável em quatro direções, que permite efetivamente o ajuste vertical, horizontal e lateral da folha da porta para atingir o desempenho de vedação exigido;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta de Correr Automática de Duas Folhas para Uso Médico</title>
				<link>https://pengchi.net/pt/automatic-medical-sliding-door/medical-double-leaf-automatic-sliding-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:58 +0000</pubDate>
				<guid>https://pengchi.net/pt/automatic-medical-sliding-door/medical-double-leaf-automatic-sliding-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt;As portas deslizantes automáticas médicas de duas folhas são projetadas especificamente para instalações de saúde, apresentando um mecanismo de abertura deslizante bidirecional que atende às demandas de alto fluxo de tráfego, manutenção de ambientes assépticos e evacuação de emergência.&lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt;01 A folha da porta é em aço com revestimento eletrostático a pó, enquanto o marco é feito de perfis extrudados de alumínio de alta resistência. São instaladas vedações em todo o perímetro da folha e do marco para garantir uma vedação hermética.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Deslizante Automática de Vidro de Folha Única para Uso Médico</title>
				<link>https://pengchi.net/pt/automatic-medical-sliding-door/medical-single-leaf-automatic-sliding-glass-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:57 +0000</pubDate>
				<guid>https://pengchi.net/pt/automatic-medical-sliding-door/medical-single-leaf-automatic-sliding-glass-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;As portas de vidro deslizantes automáticas de folha única para uso médico possuem vidros transparentes de ampla dimensão, que facilitam a observação tanto da área interna quanto da externa, tornando-as ideais para laboratórios, farmácias, salas de exame e outras instalações com requisitos rigorosos de higiene e estanqueidade.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 Opcional: vidro temperado de visão ampla com 10 mm de espessura em um lado ou vidro temperado com 5 mm de espessura em ambos os lados, com pintura eletrostática a pó na chapa de aço da base inferior;&#xA;02 A tampa do cabeçote da porta do trilho guia do motor adota design de abertura para fora, facilitando a instalação e a manutenção;&#xA;03 A moldura da folha da porta e o batente são fabricados em perfis de alumínio de alta resistência; tiras de vedação são instaladas em todo o perímetro para garantir a estanqueidade.&#xA;04 Os materiais de núcleo opcionais incluem favo de papel e favo de alumínio;&#xA;05 É possível personalizar portas de vidro deslizantes automáticas de folha única ou de folha dupla;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table&gt;&#xA;&lt;thead&gt;&lt;/thead&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Velocidade de operação de abertura da porta&lt;/td&gt;&#xA;&lt;td&gt;250–500 mm/s (ajustável)&lt;/td&gt;&#xA;&lt;td&gt;Material da moldura da porta&lt;/td&gt;&#xA;&lt;td&gt;Moldura de porta em perfil de alumínio&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Velocidade de operação de fechamento&lt;/td&gt;&#xA;&lt;td&gt;250–500 mm/s (ajustável)&lt;/td&gt;&#xA;&lt;td&gt;Preenchimento interno&lt;/td&gt;&#xA;&lt;td&gt;Favo de papel / Favo de alumínio&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Duração da abertura&lt;/td&gt;&#xA;&lt;td&gt;2–20 segundos (ajustável)&lt;/td&gt;&#xA;&lt;td&gt;Paredes compatíveis&lt;/td&gt;&#xA;&lt;td&gt;Paredes de terra, painéis de aço com revestimento colorido e paredes de montantes de aço leve&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Alimentação elétrica&lt;/td&gt;&#xA;&lt;td&gt;220V&lt;/td&gt;&#xA;&lt;td&gt;Dimensões do vão da porta&lt;/td&gt;&#xA;&lt;td&gt;Largura 1500 × Altura 2100&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Força de empurrão manual&lt;/td&gt;&#xA;&lt;td&gt;&lt;100N&lt;/td&gt;&#xA;&lt;td&gt;Dimensões do corpo da porta&lt;/td&gt;&#xA;&lt;td&gt;Largura 1584 × Altura 2122&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Material do painel&lt;/td&gt;&#xA;&lt;td&gt;Vidro em um lado, vidro em ambos os lados + pintura eletrostática a pó na chapa de aço&lt;/td&gt;&#xA;&lt;td&gt;Por tamanho&lt;/td&gt;&#xA;&lt;td&gt;Largura 1484 × Altura 2092&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;</description>
			</item>
			<item>
				<title>Porta Médica Automática de Balanço de Folha Única (ou Dupla)</title>
				<link>https://pengchi.net/pt/cleanroom-door/medical-single-or-double-leaf-automatic-swing-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:56 +0000</pubDate>
				<guid>https://pengchi.net/pt/cleanroom-door/medical-single-or-double-leaf-automatic-swing-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; As portas deslizantes automáticas médicas de folha única são projetadas especificamente para ambientes de saúde e salas limpas. Com um mecanismo de abertura deslizante unidirecional, elas são totalmente automatizadas por sensores ou sistemas de controle, atendendo aos requisitos de limpeza, segurança e acesso sem barreiras. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 As portas de batente automáticas estão disponíveis em configurações de folha única e folha dupla; selecione o tipo adequado com base nas condições do local. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Deslizante Automática de Levitação Magnética Médica</title>
				<link>https://pengchi.net/pt/automatic-medical-sliding-door/medical-magnetic-levitation-automatic-sliding-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:54 +0000</pubDate>
				<guid>https://pengchi.net/pt/automatic-medical-sliding-door/medical-magnetic-levitation-automatic-sliding-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; As portas deslizantes automáticas de folha única para uso médico são projetadas especificamente para ambientes de saúde e salas limpas. Com um mecanismo de abertura deslizante unidirecional, elas são totalmente automatizadas por meio de sensores ou sistemas de controle, atendendo aos requisitos de limpeza, segurança e acesso sem barreiras. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 Utiliza acionamento por motor linear sem caixa de engrenagens, resultando em ruído de operação ultrabaixo; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Deslizante Automática Digital baseada em IoT</title>
				<link>https://pengchi.net/pt/automatic-medical-sliding-door/iot-based-digital-automatic-sliding-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:52 +0000</pubDate>
				<guid>https://pengchi.net/pt/automatic-medical-sliding-door/iot-based-digital-automatic-sliding-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;A porta de correr automática digital habilitada para IoT é desenvolvida com base na porta de correr automática convencional e integra uma grande tela de exibição de informações digitais que fornece visualização em tempo real do pessoal, das condições ambientais, do status dos equipamentos e da qualidade do ar no interior da sala operatória.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 A capa da tela é fabricada em vidro temperado (tela sensível ao toque capacitiva);&#xA;&lt;br&gt;&#xA;02 O sistema adota arquitetura Android embarcada e suporta diversos métodos de acesso à rede, incluindo conexões com fio e Wi-Fi.&#xA;&lt;br&gt;&#xA;03 Exibe os parâmetros ambientais atuais da sala operatória, incluindo temperatura interna, umidade interna, diferencial de pressão interna, formaldeído, TVOC, CO2, PM2.5 e PM10;&#xA;&lt;br&gt;&#xA;04 Suporta comunicação em rede com o painel de informações da sala operatória para exibir a “duração da cirurgia” e a “duração da anestesia” atuais;&#xA;&lt;br&gt;&#xA;05 Integra-se ao “Sistema de Agendamento Hand-Muscle” do edifício por meio de comunicação em rede para exibir informações cirúrgicas e detalhes da equipe cirúrgica.&#xA;&lt;br&gt;&#xA;06 Suporta funções como controle remoto de ligar/desligar da iluminação e das unidades de ar-condicionado da sala operatória, além de transmissão de mensagens e notificações.&lt;br&gt;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table class=&#34;table table-bordered&#34;&gt;&#xA;&lt;thead&gt;&lt;/thead&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Velocidade de operação de abertura da porta&lt;/td&gt;&#xA;&lt;td&gt;250–500 mm/s (ajustável)&lt;/td&gt;&#xA;&lt;td&gt;Material da moldura da porta&lt;/td&gt;&#xA;&lt;td&gt;Moldura de porta em perfil de alumínio&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Velocidade de operação de fechamento&lt;/td&gt;&#xA;&lt;td&gt;250–500 mm/s (ajustável)&lt;/td&gt;&#xA;&lt;td&gt;Preenchimento interno&lt;/td&gt;&#xA;&lt;td&gt;Favo de papel / Favo de alumínio&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Duração de abertura&lt;/td&gt;&#xA;&lt;td&gt;2–20 segundos (ajustável)&lt;/td&gt;&#xA;&lt;td&gt;Parede de referência&lt;/td&gt;&#xA;&lt;td&gt;Paredes de terra, painéis de aço pré-pintados e paredes de montantes de aço leve&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Fonte de alimentação utilizada&lt;/td&gt;&#xA;&lt;td&gt;220V&lt;/td&gt;&#xA;&lt;td&gt;Dimensões do vão da porta&lt;/td&gt;&#xA;&lt;td&gt;Largura 1500 × Altura 2100&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Força de abertura manual&lt;/td&gt;&#xA;&lt;td&gt;&lt;100N&lt;/td&gt;&#xA;&lt;td&gt;Dimensões do corpo da porta&lt;/td&gt;&#xA;&lt;td&gt;Largura 1584 × Altura 2122&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Material do painel&lt;/td&gt;&#xA;&lt;td&gt;Revestimento eletrostático a pó sobre chapas de aço&lt;/td&gt;&#xA;&lt;td&gt;Por tamanho&lt;/td&gt;&#xA;&lt;td&gt;Largura 1484 × Altura 2092&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;</description>
			</item>
			<item>
				<title>Porta Dobrável Automática de Acessibilidade</title>
				<link>https://pengchi.net/pt/automatic-folding-door/accessibility-automatic-folding-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:51 +0000</pubDate>
				<guid>https://pengchi.net/pt/automatic-folding-door/accessibility-automatic-folding-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;As portas acessíveis são produtos de porta projetados para populações especiais, incluindo pessoas com deficiência, idosos e indivíduos com dificuldades de mobilidade. Elas são adequadas para uso em: locais frequentados por pessoas com deficiência;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 Emprega um sistema de acionamento por engrenagem e correia de múltiplos estágios para garantir ruído extremamente baixo durante a operação;&#xA;&lt;p&gt;02 Equipado com um motor importado do Japão, de resposta rápida e vida útil cíclica de até um milhão de operações de abertura/fechamento, tornando-o ideal para aplicações de alta frequência;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Médica Hermética Manual de Folha Única</title>
				<link>https://pengchi.net/pt/cleanroom-door/medical-manual-single-leaf-air-tight-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:47 +0000</pubDate>
				<guid>https://pengchi.net/pt/cleanroom-door/medical-manual-single-leaf-air-tight-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Unidades de porta única manual herméticas de grau médico são utilizadas principalmente em instalações especializadas com requisitos rigorosos de vedação hermética, como salas de operação hospitalares e oficinas de fabricação eletrônica.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 A folha da porta é feita de chapa de aço com revestimento em pó, e o quadro da porta é feito de perfis extrudados de alumínio de alta resistência;&#xA;&lt;p&gt;02 A folha da porta conta com estrutura em perfil extrudado de alumínio, garantindo uma estrutura robusta com excelente desempenho de suporte de carga e aumentando ainda mais sua resistência à deformação.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário de tratamento em forma de U</title>
				<link>https://pengchi.net/pt/medical-cabinet/u-shaped-treatment-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:45 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-cabinet/u-shaped-treatment-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; O armário de tratamento é um equipamento central utilizado para padronizar o armazenamento, a gestão e a retirada de suprimentos médicos, com um projeto que deve atender aos requisitos de segurança clínica, eficiência operacional e controle de infecções. Como ponto central de armazenamento de suprimentos médicos, ele pode ser utilizado para armazenar por categorias medicamentos, consumíveis estéreis, suprimentos de emergência e outros itens; &lt;/p&gt; &lt;ul&gt; &lt;/ul&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Um layout envolvente em três lados com uma área de trabalho central oferece armazenamento integrado para múltiplas funções, incluindo refrigeração, atendimento a emergências e gestão de arquivos. Ele é ideal para ambientes espaçosos e cenários de colaboração entre múltiplas pessoas. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário de tratamento em forma de L</title>
				<link>https://pengchi.net/pt/medical-cabinet/l-shaped-treatment-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:44 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-cabinet/l-shaped-treatment-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; O armário de tratamento é um equipamento central usado para padronizar o armazenamento, a gestão e a retirada de suprimentos médicos, com um projeto que deve atender aos requisitos de segurança clínica, eficiência operacional e controle de infecções. Como centro de armazenamento de suprimentos médicos, ele pode ser usado para armazenar categoricamente medicamentos, consumíveis estéreis, suprimentos de emergência e outros itens; &lt;/p&gt; &lt;ul&gt; &lt;/ul&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Composto por duas unidades de armário orientadas verticalmente que formam um canto de 90°, este projeto aproveita totalmente o espaço do canto e separa fisicamente a área limpa (preparo de medicamentos) da área contaminada (armazenamento de resíduos), reduzindo assim o risco de contaminação cruzada. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário de tratamento tipo reto</title>
				<link>https://pengchi.net/pt/medical-cabinet/straight-type-treatment-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:42 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-cabinet/straight-type-treatment-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; O armário de tratamento é um equipamento central usado para padronizar o armazenamento, a gestão e a recuperação de suprimentos médicos, com um projeto que deve atender aos requisitos de segurança clínica, eficiência operacional e controle de infecção. Como ponto central de armazenamento de suprimentos médicos, ele pode ser usado para armazenar categoricamente medicamentos, consumíveis estéreis, suprimentos de emergência e outros itens; &lt;/p&gt; &lt;ul&gt; &lt;/ul&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Um layout linear único que se estende ao longo de uma parede ou corredor, com zoneamento modular para produtos farmacêuticos, dispositivos médicos e áreas de armazenamento. Essa configuração de linha única é ideal para espaços estreitos e alongados. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário com Fechadura e Sapateira</title>
				<link>https://pengchi.net/pt/intelligent-medical-management-cabinet/locker-shoe-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:40 +0000</pubDate>
				<guid>https://pengchi.net/pt/intelligent-medical-management-cabinet/locker-shoe-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Os cacifos e cacifos para sapatos em vestiários hospitalares são instalações críticas para a proteção da segurança ocupacional dos profissionais da saúde e o controle de infecções hospitalares; seu design deve cumprir rigorosamente as diretrizes de controle de infecção e, ao mesmo tempo, atender às necessidades específicas dos diferentes cargos. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;table&gt; &lt;tbody&gt; &lt;tr&gt; &lt;td colspan=&#34;2&#34;&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/metal-locker-shoe-cabinet.webp&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/metal-locker-shoe-cabinet.webp 848w, https://pengchi.net/wp-content/uploads/2026/09/metal-locker-shoe-cabinet-300x178.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/metal-locker-shoe-cabinet-768x455.webp 768w&#34; sizes=&#34;(max-width: 848px) 100vw, 848px&#34; alt=&#34;Duas unidades de cacifo e sapateira em aço verde-azulado com portas ventiladas, exibidas lado a lado&#34;/&gt;&lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td&gt; Cacifo de seis portas &lt;/td&gt; &lt;td&gt; Cacifo de três portas &lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td colspan=&#34;2&#34;&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/blue-metal-locker-cabinets.webp&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/blue-metal-locker-cabinets.webp 847w, https://pengchi.net/wp-content/uploads/2026/09/blue-metal-locker-cabinets-300x184.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/blue-metal-locker-cabinets-768x471.webp 768w&#34; sizes=&#34;(max-width: 847px) 100vw, 847px&#34; alt=&#34;Dois cacifos altos em aço com portas turquesa perfuradas sobre fundo branco&#34;/&gt;&lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td&gt; Sapateira de quinze portas &lt;/td&gt; &lt;td&gt; Sapateira de dezoito compartimentos &lt;/td&gt; &lt;/tr&gt; &lt;/tbody&gt; &lt;/table&gt;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Material principal: corpo do armário fabricado em chapa de aço eletrolítico; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário de Medicina Tradicional Chinesa</title>
				<link>https://pengchi.net/pt/medical-cabinet/traditional-chinese-medicine-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:35 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-cabinet/traditional-chinese-medicine-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; O armário de Medicina Tradicional Chinesa é um equipamento essencial em farmácias de MTC e instituições médicas, utilizado para a classificação, armazenamento e gestão de ervas medicinais in natura; seu projeto equilibra praticidade, proporcionalidade estética e coerência geral. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;table&gt; &lt;tbody&gt; &lt;tr&gt; &lt;td colspan=&#34;3&#34;&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/traditional-chinese-medicine-cabinet.webp&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/traditional-chinese-medicine-cabinet.webp 558w, https://pengchi.net/wp-content/uploads/2026/09/traditional-chinese-medicine-cabinet-300x201.webp 300w&#34; sizes=&#34;(max-width: 558px) 100vw, 558px&#34; alt=&#34;Três armários de Medicina Tradicional Chinesa de madeira escura com fileiras de pequenas gavetas etiquetadas&#34;/&gt;&lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td&gt; Armário de Medicina Tradicional Chinesa com 20 compartimentos &lt;/td&gt; &lt;td&gt; Armário de Medicina Tradicional Chinesa de face única &lt;/td&gt; &lt;td&gt; Estação de dispensação de Medicina Tradicional Chinesa de dupla face &lt;/td&gt; &lt;/tr&gt; &lt;/tbody&gt; &lt;/table&gt; &lt;p&gt; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Plataforma panorâmica totalmente em aço</title>
				<link>https://pengchi.net/pt/all-steel-balance-platform/all-steel-sky-platform/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:32 +0000</pubDate>
				<guid>https://pengchi.net/pt/all-steel-balance-platform/all-steel-sky-platform/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/all-steel-sky-platform.webp&#34; sizes=&#34;(max-width: 889px) 100vw, 889px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/all-steel-sky-platform.webp 889w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-sky-platform-300x148.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-sky-platform-768x380.webp 768w&#34; alt=&#34;Desenhos de linha de engenharia da plataforma para balança totalmente em aço, mostrando vista isométrica e seção frontal&#34; /&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;A: Equipamento de suporte experimental com elevada capacidade de isolamento vibracional reduz efetivamente a interferência de vibrações de diversas fontes nos experimentos, garantindo assim a precisão experimental.&#xA;B: O projeto do sistema de amortecimento de vibrações, combinado com uma plataforma totalmente em aço de nível 10.000, permite atingir isolamento vibracional de Nível 3.&#xA;C: A bancada pode ser personalizada de acordo com as necessidades do cliente;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;figure&gt;&#xA;&lt;table&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;型号&#34;&gt;Modelo&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;全钢天平台&#34;&gt;Plataforma para balança totalmente em aço&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;万级全钢天平台&#34;&gt;Plataforma para balança totalmente em aço de nível 10.000&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;规格尺寸&#34;&gt;Dimensões Especificadas&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;900×600×850mm&#34;&gt;900×600×850mm&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;900×600×850mm&#34;&gt;900×600×850mm&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td rowspan=&#34;5&#34; data-t=&#34;s&#34; data-v=&#34;材料&#34;&gt;Materiais&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;主体结构&#34;&gt;Estrutura Principal&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;钢制框架结构&#34;&gt;Estrutura de quadro em aço&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;钢制框架结构&#34;&gt;Estrutura de quadro em aço&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;台面&#34;&gt;Bancada&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;40MM黑色大理石台面&#34;&gt;Bancada de mármore preto de 40mm&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;40MM黑色大理石台面 内嵌18mm大理石&#34;&gt;Bancada de mármore preto de 40mm&#xA;Mármore embutido de 18mm&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;钢架地脚&#34;&gt;Pés da Estrutura de Aço&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;PVC可调地脚&#34;&gt;Pés niveladores de PVC ajustáveis&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;PVC可调地脚&#34;&gt;Pés niveladores de PVC ajustáveis&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;台面地脚&#34;&gt;Base da Bancada&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;专用橡胶防震地脚&#34;&gt;Base dedicada de borracha para isolamento vibracional&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;专用橡胶防震地脚&#34;&gt;Base dedicada de borracha para isolamento vibracional&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;插座&#34;&gt;Tomada&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;1*10A&#34;&gt;1*10A&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;/figure&gt;</description>
			</item>
			<item>
				<title>Suporte para Reagentes de Aço e Vidro Série A</title>
				<link>https://pengchi.net/pt/rack/a-series-steel-glass-reagent-rack/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:30 +0000</pubDate>
				<guid>https://pengchi.net/pt/rack/a-series-steel-glass-reagent-rack/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Prateleira de Reagentes em Aço e Vidro Série A&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;A: As colunas verticais são fabricadas em tubo quadrado conformado integralmente, e as placas das prateleiras passam por corte de precisão e ajuste preciso, apresentando superfícies lisas, sem rebarbas e alta capacidade de carga.&#xA;B: A coluna funcional pode ser equipada com uma ampla gama de componentes para atender às diversas necessidades de aplicação dos usuários;&#xA;C: Colunas verticais de aço com revestimento de resina epóxi, conferindo excelente resistência à corrosão;&#xA;D: A prateleira é feita de vidro temperado de 10 mm e conta com altura ajustável, atendendo aos requisitos da maioria dos laboratórios.&#xA;E: A estrutura de suporte é projetada para extensão e alongamento, possibilitando a passagem de circuitos elétricos da parte superior do teto suspenso até a bancada de trabalho do laboratório;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table class=&#34;table&#34; border=&#34;1&#34;&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;规格尺寸&#34;&gt;Dimensões de Especificação&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;W×250×1000mm(单面)&#34;&gt;W×250×1000mm (face única)&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;W×400×1000mm(双面)&#34;&gt;W×400×1000mm (face dupla)&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td rowspan=&#34;4&#34; data-t=&#34;s&#34; data-v=&#34;材料&#34;&gt;Materiais&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;主体结构&#34;&gt;Estrutura Principal&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;电解钢板+环氧树脂烤漆&#34;&gt;Chapa de aço eletrolítico com revestimento em pó de resina epóxi&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电源插座&#34;&gt;Tomada Elétrica&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;按需配置&#34;&gt;Configuração conforme necessidade&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;层板&#34;&gt;Placa de Prateleira&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;钢化玻璃&#34;&gt;Vidro Temperado&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;层板档杆&#34;&gt;Haste de Suporte da Prateleira&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;不锈钢/铝型材护栏&#34;&gt;Guarda-corpo em Aço Inoxidável / Perfil de Alumínio&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;</description>
			</item>
			<item>
				<title>Suporte para Reagentes de Alumínio-Aço Série B</title>
				<link>https://pengchi.net/pt/rack/b-series-aluminum-steel-reagent-rack/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:28 +0000</pubDate>
				<guid>https://pengchi.net/pt/rack/b-series-aluminum-steel-reagent-rack/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Suporte para Reagentes de Alumínio e Aço Série B&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;A: Estrutura de aço e vidro, com montantes de aço e liga de alumínio; altura ajustável livremente.&#xA;B: Os montantes do suporte para reagentes apresentam um design simples, compacto e prático, sem detalhes supérfluos ou excessivamente complexos.&#xA;C: Tomadas elétricas são instaladas em ambos os lados da estrutura de suporte para atender às necessidades diárias de energia;&#xA;D: Conta com uma prateleira de vidro temperado de duas camadas para armazenar reagentes e outros itens;&#xA;E: A estrutura de suporte é projetada para extensão e alongamento, permitindo o roteamento de cabos elétricos desde a parte superior do teto suspenso até a bancada de trabalho do laboratório.&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table border=&#34;1&#34;&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td colspan=&#34;3&#34; data-t=&#34;s&#34; data-v=&#34;B系列铝钢试剂架&#34;&gt;Suporte para Reagentes de Alumínio e Aço Série B&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;规格尺寸&#34;&gt;Dimensões Especificadas&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;W×450×1000mm（双面）&#34;&gt;W×450×1000 mm (dupla face)&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td rowspan=&#34;4&#34; data-t=&#34;s&#34; data-v=&#34;材料&#34;&gt;Materiais&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;主体结构&#34;&gt;Estrutura Principal&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电解钢板+环氧树脂烤漆&#34;&gt;Chapa de aço eletrolítico com revestimento em pó epóxi&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电源插座&#34;&gt;Tomada Elétrica&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;按需配置&#34;&gt;Configurada conforme necessidade&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;层板&#34;&gt;Prateleira&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;钢化玻璃&#34;&gt;Vidro Temperado&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;层板档杆&#34;&gt;Haste de Suporte da Prateleira&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;不锈钢/铝型材护栏&#34;&gt;Guarda de Aço Inoxidável/Perfil de Alumínio&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;</description>
			</item>
			<item>
				<title>Rack para Reagentes em Formato de Diamante Série C</title>
				<link>https://pengchi.net/pt/rack/c-series-diamond-shaped-reagent-rack/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:27 +0000</pubDate>
				<guid>https://pengchi.net/pt/rack/c-series-diamond-shaped-reagent-rack/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Suporte para Reagentes em Forma de Diamante Série C &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt;&lt;span&gt; A: A coluna funcional pode ser equipada com uma ampla variedade de componentes para atender às diversas necessidades de aplicação dos usuários; &lt;br/&gt; B: A altura pode ser ajustada conforme necessário, e a estrutura de suporte pode ser usada para instalar armários de parede, aumentando o espaço de armazenamento; &lt;br/&gt; C: Suporte para reagentes multifuncional em formato de diamante, com aparência esteticamente agradável, instalação fácil e excelente capacidade de carga—uma única prateleira pode suportar até 50 kg. &lt;br/&gt; D: A coluna funcional oferece amplo espaço interno para acomodar tubulações hidráulicas, elétricas e de gás; ela é equipada com um painel funcional removível que pode receber dispositivos terminais, como tomadas, torneiras e válvulas de gás. &lt;/span&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Armários de Parede de Aço para Estações de Trabalho de Laboratório</title>
				<link>https://pengchi.net/pt/laboratory-cabinets/steel-wall-cabinets-for-laboratory-workstations/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:25 +0000</pubDate>
				<guid>https://pengchi.net/pt/laboratory-cabinets/steel-wall-cabinets-for-laboratory-workstations/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Armários de Parede de Aço para Estações de Trabalho de Laboratório&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;A: Fabricado em chapa de aço eletrolítico de alta qualidade com revestimento em pó epóxi, oferecendo excelente resistência à corrosão;&#xA;B: Prateleiras ajustáveis embutidas para um armazenamento mais flexível;&#xA;C: Pode ser utilizado para o armazenamento diário de documentos, materiais e suprimentos de laboratório, aumentando assim o espaço de armazenamento;&#xA;D: As folhas das portas podem ser totalmente de aço ou com vidro;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table border=&#34;1&#34;&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;型号&#34;&gt;Modelo&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;吊柜&#34;&gt;Armário de parede&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;规格尺寸&#34;&gt;Dimensões de Especificação&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;L×300×600&#34;&gt;L×300×600&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td rowspan=&#34;4&#34; data-t=&#34;s&#34; data-v=&#34;材料&#34;&gt;Materiais&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;主体结构&#34;&gt;Estrutura Principal&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电解钢板+环氧树脂烤漆&#34;&gt;Chapa de aço eletrolítico com revestimento em pó epóxi&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;拉手&#34;&gt;Puxador&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;一体成型拉手/C型不锈钢拉手&#34;&gt;Puxador moldado em peça única / Puxador de aço inoxidável em formato de C&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;合页&#34;&gt;Dobradiça&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;锌合金&#34;&gt;Liga de zinco&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;颜色&#34;&gt;Cor&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;根据实验台搭配定制&#34;&gt;Customizado de acordo com a configuração da bancada de laboratório&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;</description>
			</item>
			<item>
				<title>Série de Armários Altos (Armários para Reagentes/Armários para Recipientes/Armários para Cilindros de Gás)</title>
				<link>https://pengchi.net/pt/laboratory-cabinets/gas-cylinder-cabinets/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:24 +0000</pubDate>
				<guid>https://pengchi.net/pt/laboratory-cabinets/gas-cylinder-cabinets/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Série de Armários Altos (Armários para Reagentes / Armários para Recipientes / Armários para Cilindros de Gás)&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;A: O corpo do armário é fabricado em chapa de aço eletrogalvanizado de alta qualidade e possui acabamento com revestimento em pó epóxi, oferecendo excelente resistência a ácidos fortes, álcalis fortes e corrosão.&#xA;B: As prateleiras internas do armário são ajustáveis livremente, atendendo a diversas necessidades de aproveitamento de espaço.&#xA;C: Todos os armários são equipados com acessórios de ferragens de alta qualidade, garantindo maior vida útil e resistência superior à corrosão.&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table border=&#34;1&#34;&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;型号&#34;&gt;Modelo&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;试剂柜&#34;&gt;Armário para reagentes&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;器皿柜&#34;&gt;Armário para utensílios&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;气瓶柜&#34;&gt;Armário para cilindros de gás&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;规格尺寸&#34;&gt;Dimensões de Especificação&lt;/td&gt;&#xA;&lt;td colspan=&#34;3&#34; data-t=&#34;s&#34; data-v=&#34;900×450×1800&#34;&gt;900×450×1800&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td rowspan=&#34;4&#34; data-t=&#34;s&#34; data-v=&#34;材料&#34;&gt;Materiais&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;主体结构&#34;&gt;Estrutura Principal&lt;/td&gt;&#xA;&lt;td colspan=&#34;3&#34; data-t=&#34;s&#34; data-v=&#34;电解钢板+表面环氧树脂烤漆&#34;&gt;Chapa de aço eletrolítico com revestimento em pó epóxi na superfície&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;拉手&#34;&gt;Puxador&lt;/td&gt;&#xA;&lt;td colspan=&#34;3&#34; data-t=&#34;s&#34; data-v=&#34;不锈钢拉手/隐藏式拉手&#34;&gt;Puxadores de aço inoxidável / Puxadores embutidos&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;合页&#34;&gt;Dobradiça&lt;/td&gt;&#xA;&lt;td colspan=&#34;3&#34; data-t=&#34;s&#34; data-v=&#34;锌合金&#34;&gt;Liga de zinco&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;颜色&#34;&gt;Cor&lt;/td&gt;&#xA;&lt;td colspan=&#34;3&#34; data-t=&#34;s&#34; data-v=&#34;根据客户需求定制&#34;&gt;Personalizado de acordo com as necessidades do cliente&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;</description>
			</item>
			<item>
				<title>Série de Armários Altos (Cacifos)</title>
				<link>https://pengchi.net/pt/laboratory-cabinets/tall-cabinet-series-locker/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:23 +0000</pubDate>
				<guid>https://pengchi.net/pt/laboratory-cabinets/tall-cabinet-series-locker/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Série de Armários Altos (Armário de Vestiário)&#xA;&lt;p&gt;Utilizado principalmente para guardar roupas, calçados e chapelaria, é um móvel de laboratório indispensável.&lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;A: Utilizado principalmente para guardar roupas, calçados e chapelaria; um móvel de laboratório indispensável.&#xA;B: Fabricado em chapa de aço eletrolítico de alta qualidade com acabamento em revestimento de pó epóxi, oferecendo excelente resistência à corrosão;&#xA;C: A porta do armário apresenta construção de painel de aço de camada dupla, com preenchimento interno de material fonoabsorvente;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table border=&#34;1&#34;&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;型号&#34;&gt;Modelo&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;更衣柜&#34;&gt;Armário de Vestiário&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;规格尺寸&#34;&gt;Dimensões de Especificação&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;900×450×1800&#34;&gt;900×450×1800&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td rowspan=&#34;4&#34; data-t=&#34;s&#34; data-v=&#34;材料&#34;&gt;Materiais&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;主体结构&#34;&gt;Estrutura Principal&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电解钢板+环氧树脂烤漆&#34;&gt;Chapa de aço eletrolítico com revestimento em pó epóxi&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;拉手&#34;&gt;Puxador&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;不锈钢拉手&#34;&gt;Puxador de aço inoxidável&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;合页&#34;&gt;Dobradiça&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;锌合金&#34;&gt;Liga de zinco&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;颜色&#34;&gt;Cor&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;根据客户需求定制&#34;&gt;Customizado conforme os requisitos do cliente&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;</description>
			</item>
			<item>
				<title>Prateleira de medicina ocidental</title>
				<link>https://pengchi.net/pt/medical-cabinet/western-medicine-shelf/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:21 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-cabinet/western-medicine-shelf/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt;&lt;span&gt;&lt;span&gt; Os armários para medicamentos ocidentais são equipamentos essenciais utilizados em instituições médicas — como hospitais, clínicas e farmácias — bem como em laboratórios, para o armazenamento seguro e o gerenciamento de medicamentos ocidentais, preparações farmacêuticas e dispositivos médicos. &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;table&gt; &lt;tbody&gt; &lt;tr&gt; &lt;td colspan=&#34;2&#34;&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/western-medicine-shelf.webp&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/western-medicine-shelf.webp 504w, https://pengchi.net/wp-content/uploads/2026/09/western-medicine-shelf-300x239.webp 300w&#34; sizes=&#34;(max-width: 504px) 100vw, 504px&#34; alt=&#34;Prateleiras de medicamentos ocidentais verdes e brancas com camadas compartimentadas anguladas, exibidas nas versões de um lado e de dois lados&#34;/&gt;&lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td&gt; Prateleira de medicamentos ocidentais de um lado &lt;/td&gt; &lt;td&gt; Prateleira de medicamentos ocidentais de dois lados &lt;/td&gt; &lt;/tr&gt; &lt;/tbody&gt; &lt;/table&gt; &lt;p&gt; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Série de Armários Altos (Recipientes)</title>
				<link>https://pengchi.net/pt/laboratory-cabinets/high-cabinet-series-containers/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:18 +0000</pubDate>
				<guid>https://pengchi.net/pt/laboratory-cabinets/high-cabinet-series-containers/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Série de Armários Altos (Contêineres)&#xA;&lt;p&gt;O design de armazenamento vertical maximiza a utilização do espaço e garante a disposição ordenada dos itens.&lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;A: As unidades de prateleiras de aço passam por rigorosos cálculos de engenharia e testes para garantir sua estabilidade e segurança;&#xA;B: O design de armazenamento vertical maximiza a utilização do espaço e padroniza a disposição dos itens no interior do espaço;&#xA;C: Fabricadas em aço de alta resistência, capazes de suportar cargas elevadas;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table border=&#34;1&#34;&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;型号&#34;&gt;Modelo&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;货架&#34;&gt;Prateleira&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;规格尺寸&#34;&gt;Dimensões de Especificação&lt;/td&gt;&#xA;&lt;td colspan=&#34;2&#34; data-t=&#34;s&#34; data-v=&#34;根据客户要求定制&#34;&gt;Personalizado de acordo com as necessidades do cliente&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td rowspan=&#34;3&#34; data-t=&#34;s&#34; data-v=&#34;材料&#34;&gt;Materiais&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;主体结构&#34;&gt;Estrutura Principal&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;钢制+环氧树脂烤漆&#34;&gt;Aço com revestimento em pó epóxi&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;层数&#34;&gt;Número de camadas&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;按需定制&#34;&gt;Personalizado sob demanda&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;颜色&#34;&gt;Cor&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;按需定制&#34;&gt;Personalizado sob demanda&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;</description>
			</item>
			<item>
				<title>Bancada de Laboratório Totalmente em Aço Série A&#43;</title>
				<link>https://pengchi.net/pt/steel-laboratory-bench/a-series-all-steel-laboratory-bench/</link>
				<pubDate>Mon, 21 Sep 2026 08:57:13 +0000</pubDate>
				<guid>https://pengchi.net/pt/steel-laboratory-bench/a-series-all-steel-laboratory-bench/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;table cellpadding=&#34;1&#34; cellspacing=&#34;1&#34;&gt; &lt;tbody&gt; &lt;tr&gt; &lt;td colspan=&#34;3&#34;&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-storage-cabinet.webp&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-storage-cabinet.webp 1240w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-storage-cabinet-300x83.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-storage-cabinet-1024x283.webp 1024w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-storage-cabinet-768x212.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-storage-cabinet-900x249.webp 900w&#34; sizes=&#34;(max-width: 1240px) 100vw, 1240px&#34; alt=&#34;Colagem de várias fotos de um armário de bancada de laboratório todo em aço branco, com um close-up e portas abertas mostrando prateleiras&#34;/&gt;&lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td&gt;&lt;strong&gt; A estrutura frontal utiliza uma construção monolítica totalmente soldada. &lt;/strong&gt;&lt;/td&gt; &lt;td&gt;&lt;strong&gt; Processo de soldagem total para painel da porta e áreas de borda frontal e canto da gaveta &lt;/strong&gt;&lt;/td&gt; &lt;td&gt;&lt;strong&gt; A porta do armário possui uma estrutura de camada dupla totalmente destacável. &lt;/strong&gt;&lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td&gt; Processo de desmontagem e montagem, textura totalmente soldada &lt;/td&gt; &lt;td&gt; Processo de soldagem total &lt;/td&gt; &lt;td&gt; Evita a ferrugem interna posteriormente. &lt;/td&gt; &lt;/tr&gt; &lt;/tbody&gt; &lt;/table&gt; &lt;p&gt; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Bancada de Laboratório Série B Totalmente em Aço</title>
				<link>https://pengchi.net/pt/steel-laboratory-bench/b-series-all-steel-laboratory-bench/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:58 +0000</pubDate>
				<guid>https://pengchi.net/pt/steel-laboratory-bench/b-series-all-steel-laboratory-bench/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;table cellpadding=&#34;1&#34; cellspacing=&#34;1&#34;&gt; &lt;tbody&gt; &lt;tr&gt; &lt;td colspan=&#34;3&#34;&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench-4.webp&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench-4.webp 1224w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench-4-300x87.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench-4-1024x295.webp 1024w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench-4-768x221.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench-4-900x260.webp 900w&#34; sizes=&#34;(max-width: 1224px) 100vw, 1224px&#34; alt=&#34;Colagem com três fotos de bancada de laboratório toda em aço com frentes de gaveta laranjas, pia e detalhes da base&#34;/&gt;&lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td&gt;&lt;strong&gt; Processo de painel chanfrado tridimensional &lt;/strong&gt;&lt;/td&gt; &lt;td&gt;&lt;strong&gt; Projeto de rebordo de contenção de água curvado para dentro &lt;/strong&gt;&lt;/td&gt; &lt;td&gt;&lt;strong&gt; A estrutura inferior possui design chanfrado. &lt;/strong&gt;&lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td&gt; Bonito e elegante &lt;/td&gt; &lt;td&gt; Ergonômico &lt;/td&gt; &lt;td&gt; Facilita a operação em pé sem bater os pés. &lt;/td&gt; &lt;/tr&gt; &lt;/tbody&gt; &lt;/table&gt; &lt;p&gt; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Balcão de Informações Redondo</title>
				<link>https://pengchi.net/pt/reception-desk-in-hospital-lobby/round-information-desk/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:51 +0000</pubDate>
				<guid>https://pengchi.net/pt/reception-desk-in-hospital-lobby/round-information-desk/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; O design com bordas curvas e arredondadas evita efetivamente lesões por colisões entre a equipe de saúde, os pacientes e seus familiares. O acabamento de rodapé rebaixado ajuda a evitar tropeços, enquanto o interior do posto conta com áreas dedicadas para passagem de cabos de energia e dados, garantindo uma fiação organizada. Além disso, há um painel de acesso para manutenção embutido, com porta de inspeção nivelada. Estão disponíveis zonas personalizáveis livres de barreiras ao redor do perímetro, permitindo um atendimento ao paciente abrangente em 360 graus. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Balcão de Informações Semicircular</title>
				<link>https://pengchi.net/pt/reception-desk-in-hospital-lobby/semicircular-information-desk/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:47 +0000</pubDate>
				<guid>https://pengchi.net/pt/reception-desk-in-hospital-lobby/semicircular-information-desk/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt;O design curvo e com cantos arredondados evita eficazmente lesões por colisões entre a equipe médica, os pacientes e seus familiares. O rodapé rebaixado ajuda a evitar tropeços, enquanto o interior do posto conta com áreas dedicadas ao encaminhamento de cabos de energia e de dados para uma fiação limpa e organizada. Além disso, há um painel de acesso de manutenção oculto, com uma porta de inspeção embutida. Áreas acessíveis personalizáveis estão disponíveis em todo o perímetro, permitindo um atendimento ao paciente abrangente em 360 graus.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Balcão de Informações do Square</title>
				<link>https://pengchi.net/pt/reception-desk-in-hospital-lobby/square-information-desk/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:45 +0000</pubDate>
				<guid>https://pengchi.net/pt/reception-desk-in-hospital-lobby/square-information-desk/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; O design curvo e com cantos arredondados evita eficazmente lesões por colisões entre a equipe médica, os pacientes e seus familiares. O rodapé rebaixado ajuda a evitar tropeços, enquanto o interior da estação está equipado com áreas dedicadas à passagem de cabos de energia e dados para uma fiação limpa e organizada. Além disso, é fornecido um painel de acesso à manutenção oculto, com uma porta de inspeção embutida. Zonas sem barreiras personalizáveis estão disponíveis em todo o perímetro, permitindo um atendimento abrangente ao paciente em 360 graus. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Posto de Enfermagem em Forma de U</title>
				<link>https://pengchi.net/pt/nurse-station/u-shaped-nurse-station/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:43 +0000</pubDate>
				<guid>https://pengchi.net/pt/nurse-station/u-shaped-nurse-station/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt;O posto de enfermagem é a área operacional central de uma ala ou departamento hospitalar, desempenhando funções essenciais, como cuidados de enfermagem clínica, coordenação e gestão e comunicação de informações. Os seus principais objetivos incluem a comunicação entre paciente e médico e a prestação de serviços, coordenação e agendamento médico, manutenção de registos e transmissão de informações, bem como a gestão de medicamentos e equipamentos médicos.&lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt;Compostas por estações de trabalho dispostas em três lados para criar uma configuração semifechada, estas unidades apresentam normalmente várias superfícies de trabalho e compartimentos de armazenamento. São ideais para saguões hospitalares espaçosos ou edifícios de alas, acomodando vários profissionais de saúde a trabalhar em simultâneo e facilitando o atendimento ao paciente em múltiplas direções.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Posto de enfermagem em forma de L</title>
				<link>https://pengchi.net/pt/nurse-station/l-shaped-nurse-station/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:40 +0000</pubDate>
				<guid>https://pengchi.net/pt/nurse-station/l-shaped-nurse-station/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;O posto de enfermagem é a área operacional central de uma ala ou departamento hospitalar, desempenhando funções críticas, como cuidados de enfermagem clínica, coordenação e gestão e comunicação de informações. Os seus principais objetivos incluem a comunicação entre paciente e médico e a prestação de serviços, coordenação e agendamento médico, manutenção de registros e transmissão de informações, além do gerenciamento de medicamentos e equipamentos médicos.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;Aproveita eficientemente o espaço de canto com zoneamento multifuncional para maximizar a economia de espaço, ao mesmo tempo que acomoda tanto os fluxos de trabalho da equipe de saúde quanto o recebimento de pacientes. Ideal para áreas de canto ou espaços reduzidos, como cantos de saguão de hospital, postos de triagem em cantos de ala ou postos de enfermagem em unidades de pacientes.&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;ul&gt;&#xA; &#x9;&lt;li&gt;Material principal: corpo do armário feito em chapa de aço eletrolítico;&lt;/li&gt;&#xA; &#x9;&lt;li&gt;Balcão: pedra artificial de acrílico de grau médico;&lt;/li&gt;&#xA; &#x9;&lt;li&gt;Rodapé: aço inoxidável 304;&lt;/li&gt;&#xA; &#x9;&lt;li&gt;Aplicável a: pediatria, obstetrícia e ginecologia, medicina tradicional chinesa, departamento de emergência e outros departamentos do hospital;&lt;/li&gt;&#xA; &#x9;&lt;li&gt;Cor: personalizável para combinar com o estilo do design de interiores;&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/straight-nurse-station-dimensions.webp&#34; sizes=&#34;(max-width: 1071px) 100vw, 1071px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/straight-nurse-station-dimensions.webp 1071w, https://pengchi.net/wp-content/uploads/2026/09/straight-nurse-station-dimensions-300x153.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/straight-nurse-station-dimensions-1024x521.webp 1024w, https://pengchi.net/wp-content/uploads/2026/09/straight-nurse-station-dimensions-768x391.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/straight-nurse-station-dimensions-900x458.webp 900w&#34; alt=&#34;Desenho técnico em múltiplas vistas de postos de enfermagem em forma de L e em forma de U com anotações de dimensões&#34; /&gt;&#xA;&lt;h3&gt;Aplicações do Produto&lt;/h3&gt;&#xA;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/l-shaped-nurse-station.webp&#34; sizes=&#34;(max-width: 440px) 100vw, 440px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/l-shaped-nurse-station.webp 440w, https://pengchi.net/wp-content/uploads/2026/09/l-shaped-nurse-station-300x149.webp 300w&#34; alt=&#34;Balcão de posto de enfermagem bege em forma de L com divisória de vidro, maleta médica vermelha e placa de acesso para cadeira de rodas&#34; /&gt;</description>
			</item>
			<item>
				<title>Posto de Enfermagem Reto</title>
				<link>https://pengchi.net/pt/nurse-station/straight-nurse-station/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:36 +0000</pubDate>
				<guid>https://pengchi.net/pt/nurse-station/straight-nurse-station/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; O posto de enfermagem é a área operacional central de uma enfermaria ou departamento hospitalar, desempenhando funções cruciais como assistência de enfermagem clínica, coordenação e gestão, e comunicação de informações. Suas finalidades principais incluem a comunicação entre pacientes e médicos e a prestação de serviços, coordenação e agendamento médico, manutenção de registros e transmissão de informações, além da gestão de medicamentos e equipamentos médicos. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Projetado em layout linear, normalmente disposto ao longo de paredes ou corredores, com uma bancada limpa e contínua que enfatiza um fluxo de trabalho eficiente. O trajeto de circulação é direto e ágil, tornando-o adequado também para balcões de informação montados na parede ou postos de triagem. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Bancada de Laboratório Totalmente em Aço Série C</title>
				<link>https://pengchi.net/pt/steel-laboratory-bench/c-series-all-steel-laboratory-bench/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:33 +0000</pubDate>
				<guid>https://pengchi.net/pt/steel-laboratory-bench/c-series-all-steel-laboratory-bench/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Bancada de Laboratório Totalmente em Aço Série C &lt;/p&gt; &lt;p&gt; Bancada de trabalho central de laboratório + bancada de trabalho lateral de laboratório &lt;/p&gt; &lt;table&gt; &lt;tbody&gt; &lt;tr&gt; &lt;td&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench.webp&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench.webp 958w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench-300x200.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench-768x512.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/all-steel-laboratory-bench-900x600.webp 900w&#34; sizes=&#34;(max-width: 958px) 100vw, 958px&#34; alt=&#34;Bancada ilha de laboratório totalmente em aço branca e verde com pia, prateleiras para reagentes e armários de gavetas móveis&#34;/&gt;&lt;/td&gt; &lt;td&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/steel-laboratory-bench-cabinets.webp&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/steel-laboratory-bench-cabinets.webp 958w, https://pengchi.net/wp-content/uploads/2026/09/steel-laboratory-bench-cabinets-300x200.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/steel-laboratory-bench-cabinets-768x512.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/steel-laboratory-bench-cabinets-900x600.webp 900w&#34; sizes=&#34;(max-width: 958px) 100vw, 958px&#34; alt=&#34;Bancada de laboratório totalmente em aço com dois pedestais de gavetas móveis com detalhes verdes sobre rodízios&#34;/&gt;&lt;/td&gt; &lt;/tr&gt; &lt;/tbody&gt; &lt;/table&gt; &lt;p&gt; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Capelas de Exaustão Série A</title>
				<link>https://pengchi.net/pt/fume-hood/a-series-fume-hoods/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:25 +0000</pubDate>
				<guid>https://pengchi.net/pt/fume-hood/a-series-fume-hoods/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;figure&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/series-fume-hood-sizes.webp&#34; sizes=&#34;(max-width: 850px) 100vw, 850px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/series-fume-hood-sizes.webp 850w, https://pengchi.net/wp-content/uploads/2026/09/series-fume-hood-sizes-300x124.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/series-fume-hood-sizes-768x317.webp 768w&#34; alt=&#34;Três elevações em CAD de capelas de exaustão da série A com larguras de 1200, 1500 e 1800 mm&#34; /&gt;&lt;/figure&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;A: O vidro da janela é feito de vidro temperado com 5 mm de espessura, que não se estilhaça completamente nem se espalha em caso de quebra acidental.&#xA;B: A capela de exaustão é fabricada por moldagem por injeção de peça única em material PP, com um design geral de alta curvatura que reduz o ruído do fluxo de ar gerado durante a exaustão.&#xA;C: Projeto de acionamento por correia sincronizada dentada, com mecanismo de janela deslizante leve e suave, baixo ruído, e cabo de aço totalmente envolvido pela correia sincronizada para proteção eficaz contra corrosão;&#xA;D: Configuração básica: painel de controle LCD, disjuntor a ar de 380V, contator AC de 220V, quadro de distribuição totalmente em plástico de 8 posições de montagem superficial, dois conjuntos de tomadas de energia específicas para laboratório à prova de poeira, luminárias e fiação interna com conduíte isolado de cera amarela.&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;长度（mm）&#34;&gt;Comprimento (mm)&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;1200&#34;&gt;1200&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;1500&#34;&gt;1500&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;1800&#34;&gt;1800&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;深度（mm）&#34;&gt;Profundidade (mm)&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;850&#34;&gt;850&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;850&#34;&gt;850&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;850&#34;&gt;850&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;高度（mm）&#34;&gt;Altura (mm)&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2350&#34;&gt;2350&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2350&#34;&gt;2350&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2350&#34;&gt;2350&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;主体材质&#34;&gt;Material Principal&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电解钢板&#34;&gt;Chapa de aço eletrolítico&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电解钢板&#34;&gt;Chapa de aço eletrolítico&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电解钢板&#34;&gt;Chapa de aço eletrolítico&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;台面材质&#34;&gt;Material da Bancada&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;陶瓷/理化板&#34;&gt;Cerâmica/Placa Físico-Química&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;陶瓷/理化板&#34;&gt;Cerâmica/Placa Físico-Química&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;陶瓷/理化板&#34;&gt;Cerâmica/Placa Físico-Química&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;插座&#34;&gt;Tomada&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2*10A&#34;&gt;2*10A&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2*10A&#34;&gt;2*10A&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2*10A&#34;&gt;2*10A&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;h3&gt;Aplicações do Produto&lt;/h3&gt;&#xA;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/laboratory-fume-hood.webp&#34; sizes=&#34;(max-width: 704px) 100vw, 704px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/laboratory-fume-hood.webp 704w, https://pengchi.net/wp-content/uploads/2026/09/laboratory-fume-hood-300x200.webp 300w&#34; alt=&#34;Capela de exaustão laboratorial branca com guarnição azul, janela de vidro, torneira interna e armários inferiores&#34; /&gt;</description>
			</item>
			<item>
				<title>Capela de Exaustão de Borda Estreita Série B</title>
				<link>https://pengchi.net/pt/fume-hood/b-series-narrow-edge-fume-hood/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:22 +0000</pubDate>
				<guid>https://pengchi.net/pt/fume-hood/b-series-narrow-edge-fume-hood/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;figure&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/narrow-edge-fume-hood-sizes.webp&#34; sizes=&#34;(max-width: 865px) 100vw, 865px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/narrow-edge-fume-hood-sizes.webp 865w, https://pengchi.net/wp-content/uploads/2026/09/narrow-edge-fume-hood-sizes-300x137.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/narrow-edge-fume-hood-sizes-768x351.webp 768w&#34; alt=&#34;Três desenhos de elevação dimensionados de capelas de exaustão de borda estreita nas larguras de 1200, 1500 e 1800&#34; /&gt;&lt;/figure&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;A: Projeto de moldura ultrafina para máximo espaço de trabalho utilizável;&#xA;B: A placa defletora conta com um projeto de três seções, permitindo a remoção rápida e eficiente dos gases internos.&#xA;C: Possui uma janela de visualização fixa transparente, proporcionando aos operadores um campo de visão mais amplo;&#xA;D: A iluminação utiliza lâmpadas LED de encaixe rápido para facilitar a substituição;&#xA;E: Conta com módulos de água, eletricidade e gás configuráveis para atender de forma flexível aos requisitos de uso;&#xA;F: Janela de vidro temperado de 5 mm, que se estilhaça sem projeção de fragmentos, garantindo a segurança pessoal.&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table&gt;&#xA;&lt;thead&gt;&#xA;&lt;tr&gt;&#xA;&lt;th&gt;Comprimento (mm)&lt;/th&gt;&#xA;&lt;th&gt;1200&lt;/th&gt;&#xA;&lt;th&gt;1500&lt;/th&gt;&#xA;&lt;th&gt;1800&lt;/th&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/thead&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Profundidade (mm)&lt;/td&gt;&#xA;&lt;td&gt;850&lt;/td&gt;&#xA;&lt;td&gt;850&lt;/td&gt;&#xA;&lt;td&gt;850&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Altura (mm)&lt;/td&gt;&#xA;&lt;td&gt;2350&lt;/td&gt;&#xA;&lt;td&gt;2350&lt;/td&gt;&#xA;&lt;td&gt;2350&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Material Principal&lt;/td&gt;&#xA;&lt;td&gt;Chapa de aço eletrolítico&lt;/td&gt;&#xA;&lt;td&gt;Chapa de aço eletrolítico&lt;/td&gt;&#xA;&lt;td&gt;Chapa de aço eletrolítico&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Material da Bancada&lt;/td&gt;&#xA;&lt;td&gt;Cerâmica / Placa Físico-Química&lt;/td&gt;&#xA;&lt;td&gt;Cerâmica / Placa Físico-Química&lt;/td&gt;&#xA;&lt;td&gt;Cerâmica / Placa Físico-Química&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Tomada&lt;/td&gt;&#xA;&lt;td&gt;2*10A&lt;/td&gt;&#xA;&lt;td&gt;2*10A&lt;/td&gt;&#xA;&lt;td&gt;2*10A&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;h3&gt;Aplicações do Produto&lt;/h3&gt;&#xA;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/narrow-edge-laboratory-fume-hood.webp&#34; sizes=&#34;(max-width: 564px) 100vw, 564px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/narrow-edge-laboratory-fume-hood.webp 564w, https://pengchi.net/wp-content/uploads/2026/09/narrow-edge-laboratory-fume-hood-300x227.webp 300w&#34; alt=&#34;Três capelas de exaustão de borda estreita cinzas instaladas em um laboratório, com painéis de controle e armários de base brancos&#34; /&gt;</description>
			</item>
			<item>
				<title>Capela de Exaustão em Arco Série C</title>
				<link>https://pengchi.net/pt/fume-hood/c-series-arc-shaped-fume-hood/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:17 +0000</pubDate>
				<guid>https://pengchi.net/pt/fume-hood/c-series-arc-shaped-fume-hood/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/arc-fume-hood-smoke-test.webp&#34; sizes=&#34;(max-width: 1242px) 100vw, 1242px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/arc-fume-hood-smoke-test.webp 1242w, https://pengchi.net/wp-content/uploads/2026/09/arc-fume-hood-smoke-test-300x95.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/arc-fume-hood-smoke-test-1024x323.webp 1024w, https://pengchi.net/wp-content/uploads/2026/09/arc-fume-hood-smoke-test-768x242.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/arc-fume-hood-smoke-test-900x284.webp 900w&#34; alt=&#34;Colagem de três fotos de um teste de fluxo de ar de fumaça em uma capela de exaustão com acabamento laranja e bancada preta&#34; /&gt;&#xA;&lt;p&gt;&lt;strong&gt;Detalhes do Teste de Fumaça para Capelas de Exaustão de Arco Circular da Série C&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;table&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood-smoke.webp&#34; sizes=&#34;(max-width: 418px) 100vw, 418px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood-smoke.webp 418w, https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood-smoke-279x300.webp 279w&#34; alt=&#34;Teste de contenção de capela de exaustão em formato de arco com gerador de fumaça laranja emitindo vapor na bancada preta&#34; /&gt;&lt;/td&gt;&#xA;&lt;td&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/orange-fume-hood-control-panel.webp&#34; sizes=&#34;(max-width: 469px) 100vw, 469px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/orange-fume-hood-control-panel.webp 469w, https://pengchi.net/wp-content/uploads/2026/09/orange-fume-hood-control-panel-300x276.webp 300w&#34; alt=&#34;Detalhe em close-up de uma coluna laranja de capela de exaustão em formato de arco com aberturas de acesso circulares e painel de controle&#34; /&gt;&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;&lt;strong&gt;Mesma velocidade de face&lt;/strong&gt;&lt;/td&gt;&#xA;&lt;td&gt;&lt;strong&gt;Capela de Exaustão de Arco Circular da Série C&lt;/strong&gt;&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Comparação dos Testes de Fumaça para Diferentes Capelas de Exaustão&lt;/td&gt;&#xA;&lt;td&gt;Resultados do teste de fumaça&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;A. A coluna frontal e o defletor de admissão são projetados com uma superfície curva aerodinâmica R20, que garante uma entrada de ar mais suave na capela de exaustão e reduz a turbulência.&#xA;B. O painel lateral de entrada incorpora uma função de ar de reposição, que reduz a turbulência do ar na admissão;&#xA;C. O sistema de direcionamento de fluxo passou por extensos testes físicos e exaure com eficácia gases de diferentes gravidades específicas, mesmo em velocidades de face extremamente baixas.&#xA;D. Possui uma janela de visualização fixa transparente, proporcionando aos operadores um campo de visão mais amplo;&#xA;E. A capela de exaustão pode ajustar automaticamente sua velocidade de face e os parâmetros de fluxo de ar de exaustão com base na altura da janela de visualização, alcançando assim a eficiência energética ideal.&#xA;F. Projeto de acionamento por correia sincronizada dentada: a janela desliza de forma suave e sem esforço, com baixo ruído, e o cabo de aço é totalmente envolvido pela correia sincronizada, evitando eficazmente a corrosão;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;长度(mm)&#34;&gt;Comprimento (mm)&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;1200&#34;&gt;1200&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;1500&#34;&gt;1500&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;1800&#34;&gt;1800&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;深度(mm)&#34;&gt;Profundidade (mm)&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;850&#34;&gt;850&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;850&#34;&gt;850&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;850&#34;&gt;850&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;高度(mm)&#34;&gt;Altura (mm)&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2350&#34;&gt;2350&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2350&#34;&gt;2350&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2350&#34;&gt;2350&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;主体材质&#34;&gt;Material Principal&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电解钢板&#34;&gt;Chapa de aço eletrolítico&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电解钢板&#34;&gt;Chapa de aço eletrolítico&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;电解钢板&#34;&gt;Chapa de aço eletrolítico&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;台面材质&#34;&gt;Material da Bancada&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;陶瓷/理化板&#34;&gt;Cerâmica/Placa Físico-Química&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;陶瓷/理化板&#34;&gt;Cerâmica/Placa Físico-Química&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;陶瓷/理化板&#34;&gt;Cerâmica/Placa Físico-Química&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;插座&#34;&gt;Tomada&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2*10A&#34;&gt;2*10A&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2*10A&#34;&gt;2*10A&lt;/td&gt;&#xA;&lt;td data-t=&#34;s&#34; data-v=&#34;2*10A&#34;&gt;2*10A&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/tbody&gt;&#xA;&lt;/table&gt;&#xA;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood-dimensions.webp&#34; sizes=&#34;(max-width: 1026px) 100vw, 1026px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood-dimensions.webp 1026w, https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood-dimensions-300x136.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood-dimensions-1024x465.webp 1024w, https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood-dimensions-768x349.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood-dimensions-900x409.webp 900w&#34; alt=&#34;Três desenhos de elevação dimensionados de capelas de exaustão em formato de arco nas larguras de 1200, 1500 e 1800&#34; /&gt;&#xA;&lt;h3&gt;Aplicações do Produto&lt;/h3&gt;&#xA;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood.webp&#34; sizes=&#34;(max-width: 732px) 100vw, 732px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood.webp 732w, https://pengchi.net/wp-content/uploads/2026/09/arc-shaped-fume-hood-300x200.webp 300w&#34; alt=&#34;Capela de exaustão em formato de arco laranja e branca instalada, com janela de vidro elevada e armários de base brancos&#34; /&gt;</description>
			</item>
			<item>
				<title>Sala Cirúrgica Modular de Montagem Rápida em Alumínio com Perfil H Personalizado</title>
				<link>https://pengchi.net/pt/modular-operating-room/custom-h-profile-aluminum-quick-assembly-modular-operating-room/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:10 +0000</pubDate>
				<guid>https://pengchi.net/pt/modular-operating-room/custom-h-profile-aluminum-quick-assembly-modular-operating-room/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;A Sala Cirúrgica Modular de Montagem Rápida em Alumínio com Perfil H Personalizado conta com um sistema de estrutura de alumínio projetado especialmente, com formato semelhante ao perfil H convencional, mas adaptado para a construção de salas cirúrgicas modulares. O sistema pode ser combinado com vigas de piso, estruturas de liga de alumínio, estruturas de aço galvanizado ou estruturas de alumínio de perfil H personalizado para fornecer uma estrutura forte e estável com alta resistência sísmica.&#xA;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/modular-operating-room-interior.webp&#34; sizes=&#34;(max-width: 1416px) 100vw, 1416px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/modular-operating-room-interior.webp 1416w, https://pengchi.net/wp-content/uploads/2026/09/modular-operating-room-interior-300x74.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/modular-operating-room-interior-1024x254.webp 1024w, https://pengchi.net/wp-content/uploads/2026/09/modular-operating-room-interior-768x190.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/modular-operating-room-interior-900x223.webp 900w&#34; alt=&#34;Colagem com três vistas de salas cirúrgicas modulares concluídas, equipadas com focos cirúrgicos e pendentes de equipamentos médicos&#34; /&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;strong&gt;01. Instalação mais rápida:&lt;/strong&gt; O sistema de painéis modulares dispensa soldagem no local ou montagem de estrutura convencional. Uma sala cirúrgica individual normalmente pode ser instalada e concluída em 3 a 5 dias, dependendo do tamanho do projeto e das condições do local.&#xA;&lt;p&gt;&lt;strong&gt;02. Estrutura forte e estável:&lt;/strong&gt; O sistema estrutural pode utilizar vigas de piso, estruturas de liga de alumínio, estruturas de aço galvanizado ou estruturas de alumínio de perfil H personalizado. O perfil H personalizado é projetado especificamente para a construção de salas cirúrgicas modulares e fornece uma estrutura segura e estável com alta resistência sísmica.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Painel de face única de instalação rápida para sala de cirurgia</title>
				<link>https://pengchi.net/pt/modular-operating-room/single-sided-quick-installation-operating-room-board/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:07 +0000</pubDate>
				<guid>https://pengchi.net/pt/modular-operating-room/single-sided-quick-installation-operating-room-board/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt;A sala cirúrgica com painel de face única e instalação rápida utiliza um método de instalação com perfil estrutural fixado ao piso e parafusos de trava lateral para fixar os painéis de parede.&lt;/p&gt;&#xA;&lt;p&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/quick-install-operating-room-boards.webp&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/quick-install-operating-room-boards.webp 1057w, https://pengchi.net/wp-content/uploads/2026/09/quick-install-operating-room-boards-300x76.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/quick-install-operating-room-boards-1024x260.webp 1024w, https://pengchi.net/wp-content/uploads/2026/09/quick-install-operating-room-boards-768x195.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/quick-install-operating-room-boards-900x228.webp 900w&#34; sizes=&#34;(max-width: 1057px) 100vw, 1057px&#34; alt=&#34;Colagem com três fotos de salas cirúrgicas modulares instaladas com focos cirúrgicos e mesas cirúrgicas&#34;/&gt;&lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt;01 Menor prazo de construção: não é necessária soldagem no local nem emenda de perfis estruturais, e uma única sala cirúrgica pode ser concluída em 3 a 5 dias.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Sala de cirurgia soldada à quilha</title>
				<link>https://pengchi.net/pt/modular-operating-room/keel-welded-operating-room/</link>
				<pubDate>Mon, 21 Sep 2026 08:56:03 +0000</pubDate>
				<guid>https://pengchi.net/pt/modular-operating-room/keel-welded-operating-room/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Sala cirúrgica com estrutura soldada &lt;span&gt; Utilizando métodos de instalação por soldagem de estrutura e instalação por soldagem de estrutura (painel suspenso). &lt;/span&gt;&lt;/p&gt; &lt;p&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/keel-welded-operating-room.webp&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/keel-welded-operating-room.webp 1090w, https://pengchi.net/wp-content/uploads/2026/09/keel-welded-operating-room-300x77.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/keel-welded-operating-room-1024x261.webp 1024w, https://pengchi.net/wp-content/uploads/2026/09/keel-welded-operating-room-768x196.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/keel-welded-operating-room-900x230.webp 900w&#34; sizes=&#34;(max-width: 1090px) 100vw, 1090px&#34; alt=&#34;Colagem em três vistas de salas cirúrgicas modulares concluídas, com luminárias de teto em LED, paredes sem juntas e colunas cirúrgicas suspensas&#34;/&gt;&lt;/p&gt; &lt;p&gt; &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt;&lt;span&gt; 01 Todos os equipamentos possuem design embutido, rentes à superfície da parede, eliminando zonas mortas sanitárias e reduzindo o acúmulo de poeira. &lt;br/&gt; 02 Todas as folgas entre os painéis de parede e os equipamentos são preenchidas com selante resistente ao envelhecimento e às intempéries, garantindo durabilidade prolongada, evitando delaminação e proporcionando excelente vedação hermética. &lt;br/&gt; 03 Transições perfeitas entre paredes e entre paredes e tetos, ao mesmo tempo que aumentam a área útil do piso; &lt;br/&gt; 04 As cores do teto e das paredes podem ser selecionadas livremente para criar diferenciação visual, reduzindo efetivamente a fadiga visual e aliviando a tensão durante os procedimentos cirúrgicos. &lt;/span&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário de Medicamentos em Aço Inoxidável 304</title>
				<link>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-medicine-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:55:57 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-medicine-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;O armário de medicamentos em aço inoxidável 304 é um armário de armazenamento embutido na parede, projetado para salas operatórias modulares, salas de preparação de anestesia e outras áreas estéreis, concebido especificamente para armazenar medicamentos, frascos e consumíveis médicos. Instalado rente à superfície da parede, sem folgas expostas, organiza os medicamentos atrás de portas superiores transparentes para uma identificação rápida, com uma gaveta de largura total para itens menores e um compartimento inferior sólido para armazenamento protegido.&#xA;&lt;p&gt;O armário é construído em aço inoxidável 304 e está disponível em dois acabamentos de superfície — o mesmo produto em duas cores: um revestimento eletrostático a pó de alta temperatura com ação antibacteriana em azul clínico (Modelo PCYPG-01, com portas de dobradiças) ou um acabamento natural em aço inoxidável 304 escovado (Modelo PCYPG-02, com portas de correr), sendo possível solicitar cores personalizadas. Possui prateleiras de vidro temperado ajustáveis em altura, puxadores ocultos e ferragens silenciosas de fechamento suave, e dimensões não normalizadas podem ser fabricadas sob encomenda.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário para Instrumentos em Aço Inoxidável 304</title>
				<link>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-instrument-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:55:54 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-instrument-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;O armário para instrumentos em aço inoxidável 304 é um armário de armazenamento embutido na parede, projetado para salas cirúrgicas modulares, salas de suprimentos estéreis e outras áreas limpas, concebido especificamente para armazenar instrumentos cirúrgicos, campos cirúrgicos e pacotes de procedimentos. Instalado rente à superfície da parede, sem folgas expostas, ele combina uma seção superior transparente para rápida identificação visual com um compartimento inferior sólido para armazenamento protegido.&#xA;&lt;p&gt;O armário é construído em aço inoxidável 304 e está disponível em dois acabamentos superficiais — o mesmo produto em duas cores: um revestimento eletrostático a pó de alta temperatura, antibacteriano, na cor azul clínico (Modelo PCQXG-01, com portas com dobradiças) ou um acabamento natural em aço inoxidável 304 escovado (Modelo PCQXG-02, com portas de correr), com cores personalizadas disponíveis mediante solicitação. Ambas as versões são equipadas com prateleiras de vidro temperado ajustáveis em altura, puxadores ocultos e ferragens silenciosas de fechamento suave, e dimensões não padronizadas podem ser fabricadas sob encomenda.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário de Anestesia em Aço Inoxidável 304</title>
				<link>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-anesthesia-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:55:50 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-anesthesia-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;O Armário de Anestesia em Aço Inoxidável 304 é uma unidade de armazenamento embutida na parede projetada para salas de operação modulares, salas de preparação anestésica e outras áreas estéreis. Instalado rente à superfície da parede, sem folgas expostas, oferece armazenamento organizado e higiênico para suprimentos de anestesia, medicamentos e instrumentos cirúrgicos, ao mesmo tempo que mantém ao mínimo as superfícies acumuladoras de poeira.&#xA;&lt;p&gt;O armário é fabricado em aço inoxidável 304 e está disponível em dois acabamentos superficiais — o mesmo produto em duas opções: acabamento natural em aço inoxidável 304 escovado (Modelo PCMZG-02, com portas de correr) ou revestimento eletrostático a pó de alta temperatura antibacteriano na cor azul clínico, com cores personalizadas disponíveis mediante solicitação (Modelo PCMZG-01, com portas de abrir). Ambas as versões compartilham a mesma estrutura: uma seção superior com portas de vidro, duas gavetas na seção intermediária e um compartimento inferior com portas sólidas, além de prateleiras de vidro temperado ajustáveis em altura em um sistema de escada interno.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Gabinete para Computador em Aço Inoxidável 304</title>
				<link>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-computer-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:55:45 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-computer-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Os produtos de armários para sala de cirurgia incluem armários de medicamentos, armários de anestesia, armários de instrumentos, armários de cateteres e armários de informática. &lt;/p&gt; &lt;p&gt; Os armários da sala de cirurgia são instalados uniformemente como unidades embutidas, nivelados com a superfície da parede, destinados principalmente ao armazenamento e gerenciamento de insumos cirúrgicos, garantindo assim um ambiente cirúrgico eficiente e seguro. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;ol&gt; &lt;li&gt; A superfície pode receber acabamento em revestimento eletrostático a pó de alta temperatura ou aço inoxidável escovado 304. &lt;/li&gt; &lt;li&gt; Instalação embutida na parede e nivelada, com dimensões uniformes e sem zonas mortas sanitárias; &lt;/li&gt; &lt;li&gt; Design de escada embutido com altura ajustável, para regular livremente a altura do vidro temperado; &lt;/li&gt; &lt;li data-spm-anchor-id=&#34;5176.28103460.0.i1.4a4c7551WsyR7y&#34;&gt; O processo de ranhuramento é empregado para minimizar o raio de dobra da chapa metálica, resultando em encaixes mais justos entre os componentes de chapa e reduzindo o acúmulo de poeira. &lt;/li&gt; &lt;/ol&gt;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table&gt; &lt;thead&gt; &lt;/thead&gt; &lt;tbody&gt; &lt;tr&gt; &lt;td&gt;Número da Figura&lt;/td&gt; &lt;td&gt;PCDNG-01&lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td&gt;Especificações&lt;/td&gt; &lt;td&gt; Altura 1298 × Comprimento 898 × Profundidade 350; Altura 1698 × Comprimento 898 × Profundidade 350; Altura 1698 × Comprimento 1198 × Profundidade 350 &lt;/td&gt; &lt;/tr&gt; &lt;tr&gt; &lt;td&gt;Descrição do Produto&lt;/td&gt; &lt;td&gt; &lt;p&gt; Corpo do armário fabricado em aço inoxidável 304, com painel frontal de 1,2 mm de espessura e carcaça do armário de 1,0 mm de espessura, todos com revestimento antibacteriano aplicado na superfície; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Gabinete para Conduíte em Aço Inoxidável 304</title>
				<link>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-conduit-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:55:42 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-conduit-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;O armário de conduíte em aço inoxidável 304 é um armário de armazenamento embutido na parede, projetado para salas cirúrgicas modulares, salas de preparação de anestesia e outras áreas estéreis, concebido especificamente para pendurar cateteres, tubos de drenagem, circuitos respiratórios e outros materiais tubulares. Suas portas de batente de vidro temperado de altura total mantêm o conteúdo visível e protegido da poeira, enquanto seis conjuntos de ganchos dedicados retráteis em trilho deslizante — três ganchos por conjunto, 18 no total — mantêm a tubulação na vertical para que drene e seque livremente sem emaranhamento ou contaminação.&#xA;&lt;p&gt;O armário é construído em aço inoxidável 304 e está disponível em dois acabamentos superficiais — o mesmo produto em duas cores: um revestimento em pó eletrostático de alta temperatura antibacteriano em azul clínico (Modelo PCDGG-01) ou um acabamento natural em aço inoxidável escovado 304 (Modelo PCDGG-02), com cores personalizadas disponíveis mediante solicitação. É instalado nivelado com a parede, sem folgas expostas, e dimensões não padronizadas podem ser fabricadas sob encomenda.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário para Computador em Aço Inoxidável 304 com 5 Gavetas</title>
				<link>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-computer-cabinet-with-5-drawers/</link>
				<pubDate>Mon, 21 Sep 2026 08:55:33 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-cabinets/304-stainless-steel-computer-cabinet-with-5-drawers/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Os armários para sala de operação incluem armários de medicamentos, armários de anestesia, armários de instrumentos, armários de cateteres e armários para computador.&#xA;&lt;p&gt;Os armários da sala de operação são instalados de forma uniforme como unidades embutidas, nivelados com a superfície da parede, destinados principalmente ao armazenamento e gestão de insumos cirúrgicos, garantindo assim um ambiente cirúrgico eficiente e seguro.&lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;ol&gt;&#xA; &#x9;&lt;li&gt;A superfície pode receber acabamento em revestimento eletrostático a pó de alta temperatura ou em aço inoxidável escovado 304.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;Instalação fixada na parede, em modelo embutido e nivelado, com dimensões uniformes e sem zonas mortas sanitárias;&lt;/li&gt;&#xA; &#x9;&lt;li&gt;Projeto de estrutura em escada embutida e com altura ajustável, permitindo regular livremente a altura do vidro temperado;&lt;/li&gt;&#xA; &#x9;&lt;li data-spm-anchor-id=&#34;5176.28103460.0.i1.4a4c7551WsyR7y&#34;&gt;O processo de ranhuramento é empregado para minimizar o raio de dobra das chapas metálicas, resultando em encaixes mais justos entre os componentes de chapa e reduzindo o acúmulo de poeira.&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table border=&#34;1&#34; class=&#34;table&#34;&gt;&lt;colgroup&gt; &lt;col span=&#34;2&#34; /&gt; &lt;/colgroup&gt;&#xA;&lt;tbody&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Número da Figura&lt;/td&gt;&#xA;&lt;td&gt;PCDNG-02&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td rowspan=&#34;3&#34;&gt;Especificações&lt;/td&gt;&#xA;&lt;td&gt;Altura 1298 × Comprimento 898 × Profundidade 350&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Altura 1698 × Comprimento 898 × Profundidade 350&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Altura 1698 × Comprimento 1198 × Profundidade 350&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Descrição do Produto&lt;/td&gt;&#xA;&lt;td&gt;Corpo do armário fabricado em aço inoxidável 304, com painel de 1,2 mm de espessura e carcaça do armário de 1,0 mm de espessura;&#xA;&lt;p&gt;Processo de fresagem de ranhuras no interior do armário, sem uso de selante para vidro, tecnologia de soldagem sem costura e sem zonas mortas sanitárias.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Armário isolado e refrigerado</title>
				<link>https://pengchi.net/pt/operating-room-cabinets/insulated-and-refrigerated-cabinet/</link>
				<pubDate>Mon, 21 Sep 2026 08:55:30 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-cabinets/insulated-and-refrigerated-cabinet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Utilizado principalmente para o armazenamento de insumos médicos que necessitam de conservação em temperatura constante ou baixa temperatura, como medicamentos e dispositivos médicos utilizados durante cirurgias;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 Moldura frontal: aço inoxidável 304; corpo do gabinete: aço inoxidável 304, com 1,0 mm de espessura.&#xA;&lt;p&gt;02 Instalação embutida na parede, nivelada com a superfície da parede, sem necessidade de espaço adicional;&lt;/p&gt;&#xA;&lt;p&gt;03 Janela de visualização ampla em vidro temperado, que facilita a observação dos itens no interior da câmara a qualquer momento;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Painel inteligente com escrivaninha</title>
				<link>https://pengchi.net/pt/operating-room-control-unit/intelligence-panel-with-writing-desk/</link>
				<pubDate>Mon, 21 Sep 2026 08:55:24 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-control-unit/intelligence-panel-with-writing-desk/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; O painel de informação embutido para sala de operações conta com um design de dupla função que integra uma escrivaninha, além de oferecer controle centralizado e integrado de diversos subsistemas da sala de operações, incluindo sistemas de aquecimento, ventilação e ar condicionado, sistemas elétricos, iluminação e fornecimento de gases. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 Controle do módulo de horário: Horário de Pequim, cronômetro cirúrgico e cronômetro de anestesia; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Teto de Suprimento de Ar de Fluxo Laminar</title>
				<link>https://pengchi.net/pt/laminar-flow-ceiling/laminar-flow-air-supply-ceiling/</link>
				<pubDate>Mon, 21 Sep 2026 08:55:22 +0000</pubDate>
				<guid>https://pengchi.net/pt/laminar-flow-ceiling/laminar-flow-air-supply-ceiling/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Os difusores de teto de fluxo laminar são equipamentos essenciais para manter a limpeza do ar em salas cirúrgicas limpas, proporcionando diferentes níveis de controle microbiano para garantir um ambiente cirúrgico seguro. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 Filtros de alta eficiência configuráveis de montagem superior ou lateral, com eficiência de filtragem que atinge os graus H13/H14; &lt;/p&gt;&#xA;&lt;p&gt; 02 O teto de fluxo laminar utiliza uma malha de amortecimento DPP de camada dupla, garantindo distribuição uniforme do ar de insuflação sem zonas mortas. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Painel de lâmpada hermético</title>
				<link>https://pengchi.net/pt/laminar-flow-ceiling/air-tight-lamp-panel/</link>
				<pubDate>Mon, 21 Sep 2026 08:55:00 +0000</pubDate>
				<guid>https://pengchi.net/pt/laminar-flow-ceiling/air-tight-lamp-panel/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Painéis de luminária herméticos adequados para salas de cirurgia, ideais para uso em salas limpas com requisitos de estanqueidade do ar;&#xA;&lt;h2&gt;&lt;/h2&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 Painel de luz ultrafino para montagem em teto, com espessura de apenas 10 mm;&#xA;&lt;p&gt;02 Utiliza placas de guia de luz e chapas difusoras importadas para proporcionar uma saída de luz suave e uniforme. O painel traseiro é fabricado em alumínio, oferecendo excelente dissipação de calor;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Saída de Retorno de Ar da Sala Cirúrgica</title>
				<link>https://pengchi.net/pt/hvac-system/surgical-room-return-air-outlet/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:59 +0000</pubDate>
				<guid>https://pengchi.net/pt/hvac-system/surgical-room-return-air-outlet/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; A grelha de retorno de ar em salas cirúrgicas é um componente crítico do sistema de purificação de ar, cuja função principal é exaurir o ar contaminado da sala por meio de dutos, mantendo assim a qualidade ideal do ar. &lt;/p&gt; &lt;h2&gt; &lt;/h2&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 O pleno de retorno de ar é fabricado em chapa de aço com revestimento eletrostático a pó, com opção de painel frontal em persianas de liga de alumínio ou painel de malha de aço perfurada. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Visualizador de Filmes Tipo Tubo LED</title>
				<link>https://pengchi.net/pt/operating-room-control-unit/led-tube-type-film-viewer/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:46 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-control-unit/led-tube-type-film-viewer/</guid>
				<description>&lt;h3&gt;Descrição do produto&lt;/h3&gt;&#xA;&lt;p&gt; Equipamento utilizado em salas de operação para observação e análise de imagens médicas, como radiografias; &lt;/p&gt;&#xA;&lt;h3&gt;Características do produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 A caixa de visualização de filmes está disponível nas versões com tubo de LED e com LEDs individuais; &lt;/p&gt; &lt;p&gt; 02 Classificada de acordo com o número de filmes visualizados em conjuntos duplos, triplos, quádruplos e sêxtuplos; &lt;/p&gt; &lt;p&gt; 03 O modelo com tubo de LED possui um painel translúcido de alto brilho, com brilho não ajustável. O modelo com LEDs individuais utiliza vidro temperado e oferece brilho ajustável. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Visualizador de Filme Tipo Conta de Lâmpada LED</title>
				<link>https://pengchi.net/pt/operating-room-control-unit/led-lamp-bead-type-film-viewer/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:44 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-control-unit/led-lamp-bead-type-film-viewer/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt;Equipamento utilizado em salas de cirurgia para a observação e análise de imagens médicas, como radiografias;&lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt;01 O negatoscópio está disponível nas versões com tubo de LED e com pontos de LED;&lt;/p&gt;&#xA;&lt;p&gt;02 Classificam-se de acordo com o número de filmes visualizados em conjuntos duplos, triplos, quádruplos e sêxtuplos;&lt;/p&gt;&#xA;&lt;p&gt;03 O modelo com tubo de lâmpada possui um painel translúcido de alto brilho, com brilho não ajustável. O modelo com pontos de LED utiliza vidro temperado e oferece brilho ajustável.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Caixa de Tomada Elétrica</title>
				<link>https://pengchi.net/pt/operating-room-control-unit/power-outlet-box/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:41 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-control-unit/power-outlet-box/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Um sistema completo de distribuição de energia projetado especificamente para atender aos requisitos elétricos de salas operatórias limpas; &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 A moldura frontal está disponível em aço inoxidável 304 ou aço eletrogalvanizado com esmalte cozido; o corpo do gabinete é feito de aço inoxidável. &lt;/p&gt; &lt;p&gt; 02 As tomadas estão disponíveis em configurações de 3, 4, 5 e 6 posições, entre outras; &lt;/p&gt; &lt;p&gt; 03 As combinações de 220 V/380 V e terminais de aterramento podem ser selecionadas e configuradas livremente; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Médica de Airlock com Intertravamento Manual</title>
				<link>https://pengchi.net/pt/cleanroom-door/medical-manual-interlocking-airlock-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:37 +0000</pubDate>
				<guid>https://pengchi.net/pt/cleanroom-door/medical-manual-interlocking-airlock-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;As portas herméticas de intertravamento manuais de uso médico são uma configuração especializada de porta dupla composta por uma porta secundária mais estreita e uma porta principal mais larga.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 A folha da porta é feita de chapa de aço com revestimento em pó, e a moldura da porta é feita de extrusões de alumínio de alta resistência;&#xA;&lt;p&gt;02 A folha da porta conta com moldura de extrusão de alumínio, garantindo uma estrutura robusta com excelente desempenho de suporte de carga e aumentando ainda mais sua resistência à deformação.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Médica Manual de Folha Única em Aço</title>
				<link>https://pengchi.net/pt/medical-manual-steel-door/medical-manual-single-leaf-steel-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:25 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-manual-steel-door/medical-manual-single-leaf-steel-door/</guid>
				<description>&lt;h3&gt;Descrição do produto&lt;/h3&gt;&#xA;&lt;p&gt;Uma porta de aço de uma folha operada manualmente é uma porta de abrir de painel único fabricada em aço de alta qualidade. Ela oferece excelente resistência mecânica, longa vida útil, resistência ao fogo, resistência à umidade e bom desempenho de isolamento acústico, tornando-se uma escolha ideal para hospitais, salas limpas e outros ambientes semelhantes.&lt;/p&gt;&#xA;&lt;h3&gt;Características do produto&lt;/h3&gt;&#xA;&lt;p&gt;01 A folha da porta e o batente utilizam chapas de aço com acabamento em pintura a pó, apresentando propriedades antibacterianas e múltiplas opções de cores.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Médica Manual de Aço de Duas Folhas</title>
				<link>https://pengchi.net/pt/medical-manual-steel-door/medical-manual-double-leaf-steel-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:23 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-manual-steel-door/medical-manual-double-leaf-steel-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;Uma porta de aço de duas folhas, de acionamento manual, é um tipo de porta de abertura bipartida construída em aço de alta qualidade, oferecendo excepcional resistência, durabilidade, resistência ao fogo, à umidade e isolamento acústico. É ideal para uso em hospitais, salas limpas e outros ambientes semelhantes.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 A folha da porta e o batente são feitos de chapa de aço com revestimento em pó, oferecendo propriedades antibacterianas e uma variedade de opções de cores;&#xA;&lt;p&gt;02 Acesso sem barreiras para grandes espaços: o design de porta de duas folhas de abrir facilita a movimentação de equipamentos grandes, mercadorias ou fluxo intenso de pedestres (por exemplo, hospitais, armazéns e oficinas);&lt;/p&gt;</description>
			</item>
			<item>
				<title>Portas de Batente Médicas Manuais em Aço</title>
				<link>https://pengchi.net/pt/medical-manual-steel-door/medical-manual-steel-swing-doors/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:20 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-manual-steel-door/medical-manual-steel-swing-doors/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Portas de batente manuais em aço para uso médico, uma configuração especial de porta dupla composta por uma porta secundária mais estreita e uma porta principal mais larga; &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 A folha da porta e o aro são fabricados em chapa de aço com revestimento a pó, oferecendo propriedades antibacterianas e uma variedade de opções de cores; &lt;/p&gt; &lt;p&gt; 02 Acesso sem barreiras em grandes espaços: o design de porta de batente de duas folhas facilita a movimentação de grandes equipamentos, mercadorias ou um alto fluxo de pedestres (por exemplo, hospitais, armazéns e oficinas); &lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta de Aço Manual com Grão de Madeira para Uso Médico</title>
				<link>https://pengchi.net/pt/medical-manual-steel-door/medical-manual-wood-grain-steel-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:19 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-manual-steel-door/medical-manual-wood-grain-steel-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; Utilizando tecnologia de transferência térmica, padrões autênticos de veios de madeira são transferidos de forma perfeita para painéis de aço, proporcionando texturas nítidas e tridimensionais e um apelo visual que rivaliza com o de portas de madeira maciça. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 Utiliza tecnologia de transferência térmica para imprimir padrões autênticos de veios de madeira em chapas de aço; &lt;br/&gt; 02 Oferece uma ampla variedade de padrões de veios de madeira para atender às necessidades de diferentes estilos de design de interiores; &lt;br/&gt; 03 Substrato de aço com camada de transferência de veios de madeira, resolvendo completamente os problemas de absorção de umidade, deformação e rachaduras comuns em portas de madeira maciça, tornando-o adequado para ambientes úmidos. &lt;br/&gt; 04 O conjunto da folha da porta emprega uma estrutura de encaixe tipo espiga e caixa, sem marcas de solda e sem risco de desprendimento; &lt;br/&gt; 05 A folha da porta é equipada com tiras de vedação herméticas de alta qualidade em todo o seu perímetro, garantindo isolamento total do ar externo e mantendo a limpeza. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Automática Médica de Aço de Folha Dupla</title>
				<link>https://pengchi.net/pt/medical-manual-steel-door/medical-steel-double-leaf-automatic-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:17 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-manual-steel-door/medical-steel-double-leaf-automatic-door/</guid>
				<description>&lt;h3&gt;Descrição do produto&lt;/h3&gt;&#xA;&lt;p&gt; A porta de abertura livre bidirecional é um tipo especializado de porta projetado para operação em dois sentidos, amplamente utilizado em ambientes comerciais, industriais, de serviços de alimentação e de saúde. Ela possui abertura livre, fechamento automático, resistência a impactos e excelente desempenho de vedação. &lt;/p&gt;&#xA;&lt;h3&gt;Características do produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 As portas de abertura livre de folha dupla podem ser abertas por empurrão ou puxão tanto pelo lado interno quanto pelo externo e retornam automaticamente à posição fechada, tornando-as ideais para áreas de alto tráfego ou locais que exigem passagem frequente. &lt;br/&gt; 02 O conjunto da folha da porta utiliza uma estrutura de encaixe tipo espiga e caixa, sem marcas de solda e sem risco de desprendimento; &lt;br/&gt; 03 A dobradiça entre a porta e o batente possui design totalmente embutido, garantindo que permaneça oculta quando a porta estiver fechada e melhorando a aparência limpa e estética da folha e do batente. &lt;br/&gt; 04 A folha da porta é equipada com perfis de vedação herméticos de alta qualidade em todo o seu perímetro, garantindo isolamento completo do ar externo e mantendo a limpeza. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta de Segurança de Aço</title>
				<link>https://pengchi.net/pt/medical-steel-security-door/steel-security-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:14 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-steel-security-door/steel-security-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;As portas de segurança em aço são projetadas para uso como portas de saída de emergência em locais específicos; em caso de emergência, elas podem ser totalmente abertas, oferecendo uma aparência moderna e elegante.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 A moldura e a folha da porta são feitas de chapa de aço com revestimento em pó, oferecendo robustez, resistência a altas temperaturas e excelente resistência à corrosão.&#xA;02 Vidro temperado de camada dupla com alta dureza e excelente visibilidade;&#xA;03 Fechadura com barra de empurrar para baixo e recursos de segurança — dispensa chave, permitindo destravamento rápido em emergências;&#xA;04 Projetos personalizáveis de porta simples ou porta dupla são suportados;&#xA;&lt;h3&gt;Especificações do Produto&lt;/h3&gt;&#xA;&lt;table border=&#34;1&#34;&gt;&#xA;&lt;thead&gt;&#xA;&lt;tr&gt;&#xA;&lt;th&gt;Parâmetros&lt;/th&gt;&#xA;&lt;th&gt;Valor do parâmetro&lt;/th&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Material do painel&lt;/td&gt;&#xA;&lt;td&gt;Revestimento eletrostático a pó em chapas de aço&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Material da moldura da porta&lt;/td&gt;&#xA;&lt;td&gt;Revestimento eletrostático a pó em chapa de aço bilateral&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Acessórios de hardware&lt;/td&gt;&#xA;&lt;td&gt;A fechadura da porta e as dobradiças são ambas feitas de aço inoxidável.&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Ângulo de abertura da porta&lt;/td&gt;&#xA;&lt;td&gt;Abertura livre bidirecional de 0° a 170°&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Preenchimento interno&lt;/td&gt;&#xA;&lt;td&gt;Colmeia de papel/Colmeia de alumínio&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Parede de referência&lt;/td&gt;&#xA;&lt;td&gt;Paredes de terra, painéis de aço revestidos coloridos e paredes de perfis leves de aço&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Dimensões do vão da porta&lt;/td&gt;&#xA;&lt;td&gt;Largura 900 × Altura 2100&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Dimensões do corpo da porta&lt;/td&gt;&#xA;&lt;td&gt;Largura 846 × Altura 2060&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;tr&gt;&#xA;&lt;td&gt;Por tamanho&lt;/td&gt;&#xA;&lt;td data-spm-anchor-id=&#34;5176.28103460.0.i26.4a4c2988T47zxM&#34;&gt;Largura 819 × Altura 2063&lt;/td&gt;&#xA;&lt;/tr&gt;&#xA;&lt;/thead&gt;&#xA;&lt;/table&gt;&#xA;&lt;h3&gt;Aplicações do Produto&lt;/h3&gt;&#xA;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/09/red-steel-security-door.webp&#34; sizes=&#34;(max-width: 985px) 100vw, 985px&#34; srcset=&#34;https://pengchi.net/wp-content/uploads/2026/09/red-steel-security-door.webp 985w, https://pengchi.net/wp-content/uploads/2026/09/red-steel-security-door-300x204.webp 300w, https://pengchi.net/wp-content/uploads/2026/09/red-steel-security-door-768x522.webp 768w, https://pengchi.net/wp-content/uploads/2026/09/red-steel-security-door-900x611.webp 900w&#34; alt=&#34;Colagem com quatro fotos de portas de segurança vermelhas em aço, mostrando dobradiças, barra de pânico e painéis de vidro&#34; /&gt;</description>
			</item>
			<item>
				<title>Porta Manual de Chumbo para Proteção contra Radiação Médica</title>
				<link>https://pengchi.net/pt/medical-radiation-proof-swing-door/medical-radiation-protective-manual-lead-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:12 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-radiation-proof-swing-door/medical-radiation-protective-manual-lead-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; As portas manuais blindadas com chumbo contra radiação bloqueiam eficazmente a radiação ionizante, como raios X e raios gama, com uma eficiência de blindagem superior a 99%, sendo a solução preferida para proteção radiológica em ambientes médicos, industriais e de pesquisa. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt;&lt;span&gt; 01 O revestimento de chumbo é instalado no interior da folha da porta e do aro, com equivalência de chumbo de 2 a 4 mm Pb; &lt;br/&gt; 02 A janela de observação deve ser feita de vidro chumbado; &lt;br/&gt; 03 A superfície da porta pode receber acabamento em revestimento a pó eletrostático ou aço inoxidável 304; &lt;br/&gt; 04 As portas de chumbo manuais com dobradiças são relativamente pesadas; podem ser equipadas com um fecho de porta elétrico para abrir e fechar a folha da porta sem esforço. &lt;br/&gt; 05 O painel da folha da porta é feito de chapa de aço com revestimento a pó ou aço inoxidável 304, e o aro da porta é feito de aço inoxidável 304; &lt;/span&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Deslizante Automática de Chumbo com Proteção Radiológica para Uso Médico</title>
				<link>https://pengchi.net/pt/medical-radiation-proof-swing-door/medical-radiation-protective-automatic-sliding-lead-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:10 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-radiation-proof-swing-door/medical-radiation-protective-automatic-sliding-lead-door/</guid>
				<description>&lt;h3&gt;Descrição do produto&lt;/h3&gt;&#xA;&lt;p&gt;As portas de chumbo de correr automáticas com blindagem médica contra radiação são barreiras de proteção especializadas, projetadas para ambientes radiológicos em instalações de saúde. Ao integrar tecnologia de automação avançada com materiais de blindagem de alta densidade, essas portas bloqueiam com eficácia radiações ionizantes, como raios X e raios gama, garantindo a segurança da equipe médica e dos pacientes e aumentando a eficiência operacional nas instalações de saúde.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Caixa de Terminais de Gás</title>
				<link>https://pengchi.net/pt/operating-room-control-unit/gas-terminal-box/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:07 +0000</pubDate>
				<guid>https://pengchi.net/pt/operating-room-control-unit/gas-terminal-box/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;A caixa terminal de gases medicinais é um terminal de fornecimento de gás embutido na parede, projetado para salas de cirurgia, enfermarias de UTI e outros espaços clínicos. Ela reúne diversos serviços de gases medicinais em um único painel de montagem embutida nivelada, permitindo que anestesiologistas e a equipe clínica tenham acesso rápido e padronizado a oxigênio, ar comprimido, dióxido de carbono, nitrogênio e aspiração a vácuo no ponto de atendimento.&#xA;&lt;p&gt;A caixa é o mesmo produto em duas cores de painel — Modelo PCQTX-01 com painel azul clínico revestido a pó e Modelo PCQTX-02 na cor cinza aço inoxidável — com painel frontal disponível em aço inoxidável 304, aço inoxidável revestido a pó ou aço eletrogalvanizado revestido a pó. Os tipos de gás, o número de portas (de quatro a nove posições) e os padrões de terminal são configuráveis sob encomenda, e o projeto embutido é instalado nivelado com a parede.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Lavatório individual de aço inoxidável para lavagem das mãos</title>
				<link>https://pengchi.net/pt/medical-sink/single-person-stainless-steel-hand-washing-sink/</link>
				<pubDate>Mon, 21 Sep 2026 08:54:03 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-sink/single-person-stainless-steel-hand-washing-sink/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; O objetivo principal das pias para lavagem das mãos em aço inoxidável de grau médico é fornecer um meio para que a equipe cirúrgica e o pessoal de salas limpas possam lavar e desinfetar as mãos. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 O corpo e o fundo da cuba são totalmente construídos em aço inoxidável 304, com soldagem sem emenda para eliminar quaisquer zonas mortas sanitárias. &lt;/p&gt; &lt;p&gt; 02 O fundo da cuba possui uma inclinação projetada sob medida e bordas arredondadas em toda a sua extensão, garantindo que não haja água parada nem zonas mortas sanitárias. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Lavatório para Lavagem das Mãos em Aço Inoxidável com Duas Estações</title>
				<link>https://pengchi.net/pt/medical-sink/double-station-stainless-steel-hand-washing-sink/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:59 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-sink/double-station-stainless-steel-hand-washing-sink/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;A finalidade principal das pias de lavagem de mãos de aço inoxidável de grau médico é oferecer um meio para que a equipe cirúrgica e os funcionários de salas limpas lavem e desinfetem suas mãos.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 O corpo e o fundo da cuba são totalmente construídos em aço inoxidável 304, com soldagem sem costura para eliminar quaisquer zonas mortas sanitárias.&#xA;&lt;p&gt;02 O fundo da cuba possui um declive projetado sob medida e bordas arredondadas em toda a sua extensão, garantindo a ausência de água parada e de zonas mortas sanitárias.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Lavatório de aço inoxidável para três pessoas</title>
				<link>https://pengchi.net/pt/medical-sink/three-person-stainless-steel-hand-washing-sink/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:56 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-sink/three-person-stainless-steel-hand-washing-sink/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;A finalidade principal das pias de lavagem das mãos em aço inoxidável de grau médico é fornecer um meio para a equipe cirúrgica e o pessoal de salas limpas lavarem e desinfectarem as mãos.&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;01 O corpo e o fundo da pia são inteiramente construídos em aço inoxidável 304, com soldagem sem emenda para eliminar quaisquer zonas mortas sanitárias.&#xA;&lt;p&gt;02 O fundo da pia possui uma inclinação projetada sob medida e cantos arredondados em toda a sua extensão, garantindo ausência de água parada ou de zonas mortas sanitárias.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Lavatório de aço inoxidável para quatro pessoas</title>
				<link>https://pengchi.net/pt/medical-sink/four-person-stainless-steel-hand-washing-sink/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:54 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-sink/four-person-stainless-steel-hand-washing-sink/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; O objetivo principal dos lavatórios de mãos em aço inoxidável de grau médico é fornecer um meio para que a equipe cirúrgica e o pessoal de salas limpas lavem e desinfetem as mãos. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 O corpo e o fundo da cuba são totalmente construídos em aço inoxidável 304, com soldagem sem emenda para eliminar quaisquer pontos mortos sanitários. &lt;/p&gt; &lt;p&gt; 02 O fundo da cuba possui uma inclinação projetada sob medida e cantos arredondados em toda a sua extensão, garantindo que não haja água parada nem pontos mortos sanitários. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Pia para Lavar as Mãos em Aço Inoxidável Revestido a Pó</title>
				<link>https://pengchi.net/pt/medical-sink/powder-coated-stainless-steel-hand-washing-sink/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:50 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-sink/powder-coated-stainless-steel-hand-washing-sink/</guid>
				<description>&lt;h3&gt;Descrição do produto&lt;/h3&gt;&#xA;&lt;p&gt; O objetivo principal dos lavatórios de mãos em aço inoxidável de grau médico é proporcionar um meio para a equipa cirúrgica e o pessoal de salas limpas lavarem e desinfetarem as mãos. &lt;/p&gt;&#xA;&lt;h3&gt;Características do produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 A cuba e o fundo são totalmente construídos em aço inoxidável 304, com soldadura sem juntas para eliminar quaisquer zonas mortas sanitárias. &lt;/p&gt; &lt;p&gt; 02 O fundo da cuba possui uma inclinação projetada sob medida e bordas arredondadas em toda a volta, garantindo ausência de água parada ou de zonas mortas sanitárias. &lt;/p&gt;</description>
			</item>
			<item>
				<title>Pia Cirúrgica Dupla de Parede para Lavagem das Mãos com Acionamento pelo Joelho</title>
				<link>https://pengchi.net/pt/medical-sink/double-seat-wall-mounted-knee-controlled-surgical-handwashing-sink/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:48 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-sink/double-seat-wall-mounted-knee-controlled-surgical-handwashing-sink/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; A finalidade principal das pias de lavagem das mãos em aço inoxidável de grau médico é fornecer um meio para que a equipe cirúrgica e o pessoal de salas limpas lavem e desinfectem as mãos. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 A cuba e o fundo são totalmente feitos de aço inoxidável 304, com acabamento opcional em pintura cozida para uma aparência de aço inoxidável. &lt;br/&gt; 02 O fundo da cuba possui uma inclinação projetada sob medida e bordas arredondadas em toda a sua extensão, garantindo ausência de água parada ou zonas mortas sanitárias. &lt;br/&gt; 03 A borda de contenção e os cantos da estrutura da cuba são projetados com arcos arredondados; &lt;br/&gt; 04 Equipada com suportes angulares de fixação, toda a unidade pode ser montada na parede; &lt;br/&gt; 05 Os recursos opcionais incluem aquecedor de água termostático, luzes de espelho e uma torneira cascata ajustável em 360 graus, entre outros; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Lavatório Triplo de Parede em Aço Inoxidável com Acionamento pelo Joelho</title>
				<link>https://pengchi.net/pt/medical-sink/three-seat-wall-mounted-stainless-steel-knee-control-handwashing-sink/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:39 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-sink/three-seat-wall-mounted-stainless-steel-knee-control-handwashing-sink/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; A finalidade principal das pias de lavagem das mãos em aço inoxidável de grau médico é fornecer um meio para a equipe cirúrgica e o pessoal de salas limpas lavarem e desinfetarem as mãos. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 A estrutura e o fundo da cuba são totalmente feitos de aço inoxidável 304, com acabamento opcional em pintura a estufa na cor aço inoxidável. &lt;br/&gt; 02 O fundo da cuba possui inclinação projetada sob medida e bordas arredondadas em toda a sua extensão, garantindo ausência de água parada ou zonas mortas sanitárias. &lt;br/&gt; 03 A borda de retenção de água e os cantos da estrutura da cuba são projetados com arcos arredondados; &lt;br/&gt; 04 Equipada com cantoneiras de fixação, toda a unidade pode ser montada na parede; &lt;br/&gt; 05 Os recursos opcionais incluem aquecedor de água termostático, luzes de iluminação da bancada e uma torneira cascata ajustável em 360 graus, entre outros; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Lavatório Duplo de Acrílico Montado na Parede</title>
				<link>https://pengchi.net/pt/medical-sink/double-seat-wall-mounted-acrylic-hand-washing-basin/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:36 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-sink/double-seat-wall-mounted-acrylic-hand-washing-basin/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt; A finalidade principal das pias de lavagem das mãos em aço inoxidável de grau médico é fornecer um meio para que a equipe cirúrgica e o pessoal de salas limpas lavem e desinfetem as mãos. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 O corpo e o fundo da cuba são totalmente em aço inoxidável 304, com acabamento opcional em pintura cozida para aparência de aço inoxidável. &lt;br/&gt; 02 O fundo da cuba possui uma inclinação projetada sob medida e bordas arredondadas em toda a sua extensão, garantindo ausência de água parada ou zonas mortas sanitárias. &lt;br/&gt; 03 A borda de contenção de água e os cantos da estrutura da cuba são projetados com arcos arredondados; &lt;br/&gt; 04 Equipada com cantoneiras de fixação, a unidade inteira pode ser montada na parede; &lt;br/&gt; 05 Os recursos opcionais incluem aquecedor termostático de água, luzes de espelho e uma torneira cascata ajustável em 360 graus, entre outros; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Caixa de Passagem com Janela de Transferência e Intertravamento Mecânico para Sala Limpa</title>
				<link>https://pengchi.net/pt/pass-through-window/mechanical-interlock-pass-through-window-pass-box-for-cleanroom/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:34 +0000</pubDate>
				<guid>https://pengchi.net/pt/pass-through-window/mechanical-interlock-pass-through-window-pass-box-for-cleanroom/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt;&lt;meta charset=&#34;utf-8&#34;/&gt; &lt;/p&gt; &lt;p&gt; Janela de Passagem com Intertravamento Mecânico &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; A: O projeto de intertravamento de portas duplas garante que apenas uma porta possa ser aberta por vez durante a operação normal. &lt;/p&gt; &lt;p&gt; B: Uma lâmpada de esterilização pode ser instalada para eliminar eficazmente todas as bactérias transportadas pelos itens transferidos; &lt;/p&gt; &lt;p&gt; C: Todo o gabinete é construído em aço inoxidável 304, com cantos arredondados nas paredes internas. &lt;/p&gt; &lt;p&gt; D: Cada lado está equipado com uma janela de observação para monitoramento em tempo real da transferência de itens; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Filtro primário</title>
				<link>https://pengchi.net/pt/air-filter/primary-filter/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:33 +0000</pubDate>
				<guid>https://pengchi.net/pt/air-filter/primary-filter/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt;&lt;meta charset=&#34;utf-8&#34;/&gt; &lt;/p&gt; &lt;p&gt; O filtro de ar é um dispositivo utilizado para remover partículas, poeira, micro-organismos e gases nocivos do ar, sendo amplamente utilizado em indústrias, ambientes de saúde e salas limpas. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 Com base na eficiência de filtragem, os filtros são classificados como filtros primários, médios e de alta eficiência; &lt;br/&gt; 02 O filtro de alta eficiência utiliza fibra de vidro ultrafina como elemento filtrante, com estrutura dedicada em liga de alumínio. &lt;br/&gt; 03 Grande área de filtragem, baixa resistência, alta capacidade de retenção de poeira, velocidade do ar uniforme, alta precisão de filtragem e baixos custos operacionais; &lt;br/&gt; 04 Filtros de alta eficiência com classes de filtragem de H10 a U17; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Filtro de média eficiência</title>
				<link>https://pengchi.net/pt/air-filter/medium-efficiency-filter/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:29 +0000</pubDate>
				<guid>https://pengchi.net/pt/air-filter/medium-efficiency-filter/</guid>
				<description>&lt;h3&gt;Descrição do produto&lt;/h3&gt;&#xA;&lt;p&gt;&lt;meta charset=&#34;utf-8&#34;/&gt; &lt;/p&gt; &lt;p&gt; O filtro de ar é um dispositivo usado para remover partículas, poeira, microrganismos e gases nocivos do ar, sendo amplamente utilizado em indústrias, ambientes de saúde e salas limpas. &lt;/p&gt;&#xA;&lt;h3&gt;Características do produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 Com base na eficiência de filtragem, os filtros são classificados em filtros primários, médios e de alta eficiência; &lt;br/&gt; 02 O filtro de alta eficiência utiliza fibra de vidro ultrafina como elemento filtrante, com moldura específica em liga de alumínio. &lt;br/&gt; 03 Grande área de filtragem, baixa resistência, alta capacidade de retenção de poeira, velocidade do ar uniforme, alta precisão de filtragem e baixos custos operacionais; &lt;br/&gt; 04 Filtros de alta eficiência com classes de filtragem de H10 a U17; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Filtro particionado de alta eficiência</title>
				<link>https://pengchi.net/pt/air-filter/high-efficiency-partitioned-filter/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:26 +0000</pubDate>
				<guid>https://pengchi.net/pt/air-filter/high-efficiency-partitioned-filter/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt;&lt;meta charset=&#34;utf-8&#34;/&gt; &lt;/p&gt; &lt;p&gt; Um filtro de ar é um dispositivo utilizado para remover partículas, poeira, microrganismos e gases nocivos do ar, sendo amplamente empregado em indústrias, ambientes de saúde e salas limpas. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 De acordo com a eficiência de filtragem, os filtros são classificados em filtros de eficiência primária, média e alta; &lt;br/&gt; 02 O filtro de alta eficiência utiliza fibra de vidro ultrafina como elemento filtrante, com uma moldura dedicada de liga de alumínio. &lt;br/&gt; 03 Grande área de filtragem, baixa resistência, alta capacidade de retenção de poeira, velocidade do ar uniforme, alta precisão de filtragem e baixos custos operacionais; &lt;br/&gt; 04 Filtros de alta eficiência com graus de filtragem que variam de H10 a U17; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Filtro de alta eficiência, sem separador</title>
				<link>https://pengchi.net/pt/air-filter/high-efficiency-separator-free-filter/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:24 +0000</pubDate>
				<guid>https://pengchi.net/pt/air-filter/high-efficiency-separator-free-filter/</guid>
				<description>&lt;h3&gt;Descrição do produto&lt;/h3&gt;&#xA;&lt;p&gt;&lt;meta charset=&#34;utf-8&#34;/&gt; &lt;/p&gt; &lt;p&gt; O filtro de ar é um dispositivo usado para remover partículas, poeira, microrganismos e gases nocivos do ar, sendo amplamente utilizado em indústrias, ambientes de saúde e salas limpas. &lt;/p&gt;&#xA;&lt;h3&gt;Características do produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 Com base na eficiência de filtragem, os filtros são classificados em filtros primários, médios e de alta eficiência; &lt;br/&gt; 02 O filtro de alta eficiência utiliza fibra de vidro ultrafina como elemento filtrante, com uma moldura dedicada em liga de alumínio. &lt;br/&gt; 03 Grande área de filtragem, baixa resistência, alta capacidade de retenção de poeira, velocidade do ar uniforme, alta precisão de filtragem e baixos custos operacionais; &lt;br/&gt; 04 Filtros de alta eficiência com classes de filtragem de H10 a U17; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Filtro em V de Alta Eficiência</title>
				<link>https://pengchi.net/pt/air-filter/v-shape-high-efficiency-filter/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:22 +0000</pubDate>
				<guid>https://pengchi.net/pt/air-filter/v-shape-high-efficiency-filter/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;&lt;p&gt;&lt;meta charset=&#34;utf-8&#34;/&gt; &lt;/p&gt; &lt;p&gt; O filtro de ar é um dispositivo utilizado para remover partículas, poeira, microrganismos e gases nocivos do ar, sendo amplamente empregado em indústrias, ambientes de saúde e salas limpas. &lt;/p&gt;&#xA;&lt;h3&gt;Características do Produto&lt;/h3&gt;&#xA;&lt;p&gt; 01 De acordo com a eficiência de filtragem, os filtros são classificados em filtros primários, de média eficiência e de alta eficiência; &lt;br/&gt; 02 O filtro de alta eficiência utiliza fibra de vidro ultrafina como elemento filtrante, com uma moldura dedicada em liga de alumínio. &lt;br/&gt; 03 Grande área de filtragem, baixa resistência, alta capacidade de retenção de poeira, velocidade do ar uniforme, alta precisão de filtragem e baixos custos operacionais; &lt;br/&gt; 04 Filtros de alta eficiência com classes de filtragem que variam de H10 a U17; &lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Médica Hermética Manual de Duas Folhas</title>
				<link>https://pengchi.net/pt/cleanroom-door/medical-manual-double-leaf-airtight-door/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:19 +0000</pubDate>
				<guid>https://pengchi.net/pt/cleanroom-door/medical-manual-double-leaf-airtight-door/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;As portas estanques manuais de duas folhas para uso médico são um tipo de porta de alta vedação projetada especificamente para ambientes de salas limpas em instalações de saúde, usada principalmente em corredores limpos, UTIs, laboratórios e outras áreas com requisitos rigorosos de limpeza do ar e isolamento acústico.&#xA;&lt;div data-is-intersecting=&#34;true&#34; data-turn-id-container=&#34;d7b702a3-d409-45fc-8a38-3d3c28dc215a&#34;&gt;&lt;/div&gt;&#xA;&lt;div data-is-intersecting=&#34;true&#34; data-turn-id-container=&#34;request-69bbbb36-211c-8326-b59e-409491c798b3-2&#34;&gt;&lt;section dir=&#34;auto&#34; data-testid=&#34;conversation-turn-462&#34; data-turn=&#34;assistant&#34; data-turn-id=&#34;request-69bbbb36-211c-8326-b59e-409491c798b3-2&#34; data-turn-id-container=&#34;request-69bbbb36-211c-8326-b59e-409491c798b3-2&#34;&gt;&#xA;&lt;div&gt;&#xA;&lt;div data-conversation-screenshot-content=&#34;&#34;&gt;&#xA;&lt;div&gt;&#xA;&lt;div dir=&#34;auto&#34; tabindex=&#34;0&#34; data-message-author-role=&#34;assistant&#34; data-message-id=&#34;5db6f58a-fc01-4479-8068-baf0bb691c0a&#34; data-message-model-slug=&#34;gpt-5-5-mini&#34; data-turn-start-message=&#34;true&#34;&gt;&#xA;&lt;div&gt;&#xA;&lt;div&gt;&#xA;&lt;p data-end=&#34;337&#34; data-start=&#34;0&#34;&gt;&lt;strong&gt;Porta de aço estanque de duas folhas&lt;/strong&gt; oferece vedação confiável, proteção robusta e desempenho duradouro para hospitais, salas limpas, laboratórios e instalações industriais. Projetada com materiais de aço de alta qualidade e tecnologia de fabricação avançada, esta porta oferece excelente estanqueidade, resistência à corrosão e longa vida útil.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Lavatório para Lavagem das Mãos de Três Lugares, Montado na Parede, com Acionamento pelo Joelho</title>
				<link>https://pengchi.net/pt/medical-sink/three-seat-wall-mounted-knee-controlled-handwashing-sink/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:17 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-sink/three-seat-wall-mounted-knee-controlled-handwashing-sink/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA;A finalidade principal dos lavatórios de mãos em aço inoxidável de grau médico é fornecer um meio para a equipe cirúrgica e o pessoal de salas limpas lavarem e desinfetarem as mãos.&#xA;&lt;div&gt;&#xA;&lt;div dir=&#34;auto&#34; data-message-author-role=&#34;assistant&#34; data-message-id=&#34;72f0f4a6-56a5-4782-9ddb-f8e9bce43918&#34; data-message-model-slug=&#34;gpt-5-6&#34;&gt;&#xA;&lt;div&gt;&#xA;&lt;div&gt;&#xA;&lt;p data-end=&#34;1199&#34; data-is-last-node=&#34;&#34; data-is-only-node=&#34;&#34; data-start=&#34;55&#34;&gt;Nossas soluções de &lt;strong&gt;OEM de estação de lavagem de mãos para sala de cirurgia&lt;/strong&gt; são projetadas para atender aos rigorosos requisitos de higiene de hospitais modernos, centros cirúrgicos e instalações médicas. Fabricadas com aço inoxidável de alta qualidade, essas estações de escovagem cirúrgica apresentam resistência à corrosão, superfícies fáceis de limpar e estruturas confiáveis para uso a longo prazo. Oferecemos serviços OEM personalizados, incluindo tamanho, configuração, opções de torneiras, sistemas de controle por sensor e projetos de instalação para atender a diferentes layouts de salas de cirurgia. As estações de lavagem de mãos são projetadas para apoiar o controle eficaz de infecções, reduzindo os riscos de contaminação e melhorando a eficiência da preparação cirúrgica. Adequadas para hospitais, laboratórios, clínicas e projetos de saúde, nossas capacidades de produção OEM garantem qualidade estável, personalização flexível e suporte profissional de fabricação. De pias cirúrgicas de um único usuário a vários usuários, fornecemos soluções práticas que combinam durabilidade, segurança e requisitos de ambientes médicos modernos. Escolha nosso serviço OEM de estação de lavagem de mãos para sala de cirurgia para obter produtos confiáveis e adaptados aos padrões globais de saúde.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Janela de Passagem com Intertravamento Eletrônico</title>
				<link>https://pengchi.net/pt/pass-through-window/electronic-interlock-pass-through-window/</link>
				<pubDate>Mon, 21 Sep 2026 08:53:14 +0000</pubDate>
				<guid>https://pengchi.net/pt/pass-through-window/electronic-interlock-pass-through-window/</guid>
				<description>&lt;h3&gt;Descrição do Produto&lt;/h3&gt;&#xA; &#xA;&lt;p&gt;Janela de Passagem com Intertravamento Eletrônico&lt;/p&gt;&#xA;&lt;div&gt;&#xA;&lt;div dir=&#34;auto&#34; data-message-author-role=&#34;assistant&#34; data-message-id=&#34;e59c2f81-c60a-43ad-9ee5-350a5b426e42&#34; data-message-model-slug=&#34;gpt-5-6&#34;&gt;&#xA;&lt;div&gt;&#xA;&lt;div&gt;&#xA;&lt;p data-end=&#34;633&#34; data-is-last-node=&#34;&#34; data-is-only-node=&#34;&#34; data-start=&#34;44&#34;&gt;Nossas &lt;strong&gt;janelas de transferência com intertravamento para salas limpas&lt;/strong&gt; são projetadas para a transferência segura e eficiente de materiais entre salas limpas ou ambientes controlados. O sistema de intertravamento mecânico ou eletrônico impede que as duas portas sejam abertas simultaneamente, ajudando a manter a limpeza do ar e a reduzir a contaminação cruzada. A personalização OEM está disponível para dimensões, materiais, estruturas de porta, janelas de visualização, métodos de intertravamento e requisitos de instalação. Adequado para os setores farmacêutico, laboratorial, eletrônico, de dispositivos médicos, processamento de alimentos e outros ambientes de produção controlados.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Porta Médica de Chumbo Sobreposta à Prova de Radiação</title>
				<link>https://pengchi.net/pt/medical-radiation-proof-swing-door/medical-overlapping-radiation-proof-lead-door/</link>
				<pubDate>Fri, 11 Sep 2026 07:15:45 +0000</pubDate>
				<guid>https://pengchi.net/pt/medical-radiation-proof-swing-door/medical-overlapping-radiation-proof-lead-door/</guid>
				<description>&lt;div id=&#34;01&#34; class=&#34;e_container-67 s_layout response-transition&#34;&gt;&#xA;&lt;div class=&#34;cbox-67-0 p_item&#34;&gt;&#xA;&lt;div class=&#34;e_richText-69 s_title clearfix response-transition&#34;&gt;&#xA;&lt;p&gt;As portas de blindagem contra radiação de chumbo multicamadas são utilizadas principalmente em salas de cirurgia DSA. Elas possuem aberturas de entrada e saída excepcionalmente largas para acomodar equipamentos de diagnóstico por imagem de grande porte, ao mesmo tempo que evitam eficazmente o vazamento de radiação de raios X, garantindo a segurança radiológica tanto dentro quanto fora da sala de cirurgia.&lt;/p&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div id=&#34;02&#34; class=&#34;e_container-75 s_layout response-transition&#34;&gt;&#xA;&lt;div class=&#34;cbox-75-0 p_item&#34;&gt;&#xA;&lt;div class=&#34;e_richText-77 s_title clearfix response-transition&#34;&gt;&#xA;&lt;ol&gt;&#xA; &#x9;&lt;li&gt;A porta de chumbo deslizante automática sobreposta é construída com painéis de chumbo de alta pureza, o que a torna ideal para uso em salas de cirurgia híbridas DSA. Ela protege eficazmente contra a radiação nociva, garantindo assim a segurança dentro da sala de cirurgia.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;Design espaçoso e aberto com configuração de sobreposição integrada; é personalizável para abertura à direita, à esquerda ou bipartida, garantindo a passagem desobstruída de diversos equipamentos de inspeção de grande porte.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;Design flexível: A configuração de abertura da porta pode ser personalizada — de folha única em um lado ou de duas folhas com abertura simétrica — de acordo com os requisitos especificados nos desenhos do projeto da sala de cirurgia.&lt;/li&gt;&#xA; &#x9;&lt;li&gt;Operação silenciosa: equipada com motor importado e acionamento de alta potência, combinados a um sistema de polias ultrassilencioso, garantindo uma abertura de porta suave, sem esforço e sem ruídos.&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;</description>
			</item>
			<item>
				<title>Fale Conosco</title>
				<link>https://pengchi.net/pt/contact-us/</link>
				<pubDate>Fri, 11 Sep 2026 05:56:09 +0000</pubDate>
				<guid>https://pengchi.net/pt/contact-us/</guid>
				<description>&lt;section class=&#34;pb-4 pb-lg-5 mb-4 mb-lg-5 border-bottom&#34;&gt;&#xA;&lt;p class=&#34;small fw-semibold text-uppercase text-success mb-2&#34;&gt;Envie-nos uma Mensagem&lt;/p&gt;&#xA;&lt;script src=&#34;https://js-na2.hsforms.net/forms/embed/247495286.js&#34; defer&gt;&lt;/script&gt;&#xA;&lt;div class=&#34;hs-form-frame&#34; data-region=&#34;na2&#34; data-form-id=&#34;7b45a6d3-a989-4ef4-a95a-e937a0761d6a&#34; data-portal-id=&#34;247495286&#34;&gt;&lt;/div&gt;&#xA;&lt;/section&gt;&#xA;&lt;section class=&#34;pb-4 pb-lg-5&#34;&gt;&#xA;&lt;div class=&#34;row g-4 g-lg-5&#34;&gt;&#xA;&lt;div class=&#34;col-lg-5&#34;&gt;&#xA;&lt;p class=&#34;small fw-semibold text-uppercase text-success mb-2&#34;&gt;Entre em Contato&lt;/p&gt;&#xA;&lt;h2 class=&#34;fw-bold mb-3&#34;&gt;Fale com a Pengchi&lt;/h2&gt;&#xA;&lt;p class=&#34;fw-semibold mb-3&#34;&gt;Dongguan Pengchi Intelligent Equipment Technology Co., Ltd.&lt;/p&gt;&#xA;&lt;ul class=&#34;list-unstyled m-0&#34;&gt;&#xA;&#x9;&lt;li class=&#34;row g-0 gap-3 py-3 border-bottom&#34;&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col-auto&#34;&gt;&lt;i class=&#34;bi bi-telephone text-success fs-5 lh-base&#34;&gt;&lt;/i&gt;&lt;/div&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col&#34;&gt;&#xA;&#x9;&#x9;&#x9;&lt;div class=&#34;small fw-semibold text-uppercase text-body-secondary mb-1&#34;&gt;Telefone&lt;/div&gt;&#xA;&#x9;&#x9;&#x9;&lt;a class=&#34;link-body-emphasis link-offset-2 link-underline-opacity-0 link-underline-opacity-100-hover text-break&#34; href=&#34;tel:+86-769-38839633-879&#34;&gt;+86 0769-38839633-879&lt;/a&gt;&#xA;&#x9;&#x9;&lt;/div&gt;&#xA;&#x9;&lt;/li&gt;&#xA;&#x9;&lt;li class=&#34;row g-0 gap-3 py-3 border-bottom&#34;&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col-auto&#34;&gt;&lt;i class=&#34;bi bi-phone text-success fs-5 lh-base&#34;&gt;&lt;/i&gt;&lt;/div&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col&#34;&gt;&#xA;&#x9;&#x9;&#x9;&lt;div class=&#34;small fw-semibold text-uppercase text-body-secondary mb-1&#34;&gt;Celular / WhatsApp&lt;/div&gt;&#xA;&#x9;&#x9;&#x9;&lt;a class=&#34;link-body-emphasis link-offset-2 link-underline-opacity-0 link-underline-opacity-100-hover text-break&#34; href=&#34;tel:+8618025283503&#34;&gt;+86 18025283503&lt;/a&gt;&#xA;&#x9;&#x9;&lt;/div&gt;&#xA;&#x9;&lt;/li&gt;&#xA;&#x9;&lt;li class=&#34;row g-0 gap-3 py-3 border-bottom&#34;&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col-auto&#34;&gt;&lt;i class=&#34;bi bi-envelope text-success fs-5 lh-base&#34;&gt;&lt;/i&gt;&lt;/div&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col&#34;&gt;&#xA;&#x9;&#x9;&#x9;&lt;div class=&#34;small fw-semibold text-uppercase text-body-secondary mb-1&#34;&gt;E-mail&lt;/div&gt;&#xA;&#x9;&#x9;&#x9;&lt;a class=&#34;link-body-emphasis link-offset-2 link-underline-opacity-0 link-underline-opacity-100-hover text-break&#34; href=&#34;mailto:pengchi@pengchihealth.com&#34;&gt;pengchi@pengchihealth.com&lt;/a&gt;&#xA;&#x9;&#x9;&lt;/div&gt;&#xA;&#x9;&lt;/li&gt;&#xA;&#x9;&lt;li class=&#34;row g-0 gap-3 py-3 border-bottom&#34;&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col-auto&#34;&gt;&lt;i class=&#34;bi bi-globe2 text-success fs-5 lh-base&#34;&gt;&lt;/i&gt;&lt;/div&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col&#34;&gt;&#xA;&#x9;&#x9;&#x9;&lt;div class=&#34;small fw-semibold text-uppercase text-body-secondary mb-1&#34;&gt;Site Oficial&lt;/div&gt;&#xA;&#x9;&#x9;&#x9;&lt;a class=&#34;link-body-emphasis link-offset-2 link-underline-opacity-0 link-underline-opacity-100-hover text-break&#34; href=&#34;https://pengchi.net&#34; target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34;&gt;https://pengchi.net&lt;/a&gt;&#xA;&#x9;&#x9;&lt;/div&gt;&#xA;&#x9;&lt;/li&gt;&#xA;&#x9;&lt;li class=&#34;row g-0 gap-3 py-3 border-bottom&#34;&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col-auto&#34;&gt;&lt;i class=&#34;bi bi-shop text-success fs-5 lh-base&#34;&gt;&lt;/i&gt;&lt;/div&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col&#34;&gt;&#xA;&#x9;&#x9;&#x9;&lt;div class=&#34;small fw-semibold text-uppercase text-body-secondary mb-1&#34;&gt;Loja no Made-in-China&lt;/div&gt;&#xA;&#x9;&#x9;&#x9;&lt;a class=&#34;link-body-emphasis link-offset-2 link-underline-opacity-0 link-underline-opacity-100-hover text-break&#34; href=&#34;https://pengchihealthcare.en.made-in-china.com/&#34; target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34;&gt;https://pengchihealthcare.en.made-in-china.com/&lt;/a&gt;&#xA;&#x9;&#x9;&lt;/div&gt;&#xA;&#x9;&lt;/li&gt;&#xA;&#x9;&lt;li class=&#34;row g-0 gap-3 pt-3&#34;&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col-auto&#34;&gt;&lt;i class=&#34;bi bi-geo-alt text-success fs-5 lh-base&#34;&gt;&lt;/i&gt;&lt;/div&gt;&#xA;&#x9;&#x9;&lt;div class=&#34;col&#34;&gt;&#xA;&#x9;&#x9;&#x9;&lt;div class=&#34;small fw-semibold text-uppercase text-body-secondary mb-1&#34;&gt;Base de Produção&lt;/div&gt;&#xA;&#x9;&#x9;&#x9;&lt;span class=&#34;text-body-secondary&#34;&gt;N.º 148, Chashi Road, Cidade de Chashan, Cidade de Dongguan, Província de Guangdong (Parque de Tecnologia Inteligente Pengchi)&lt;/span&gt;&#xA;&#x9;&#x9;&lt;/div&gt;&#xA;&#x9;&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;col-lg-7&#34;&gt;&#xA;&lt;a class=&#34;d-block position-relative rounded-3 overflow-hidden border text-decoration-none&#34; href=&#34;https://www.google.com/maps/search/?api=1&amp;query=No.%20148%2C%20Chashi%20Road%2C%20Chashan%20Town%2C%20Dongguan%2C%20Guangdong%2C%20China%20(Pengchi%20Smart%20Technology%20Park)&#34; target=&#34;_blank&#34; rel=&#34;noopener noreferrer&#34;&gt;&#xA;&lt;img class=&#34;img-fluid w-100 d-block&#34; src=&#34;https://pengchi.net/wp-content/uploads/2026/09/pengchi-map.jpg&#34; alt=&#34;Mapa da localização da Pengchi: N.º 148, Chashi Road, Cidade de Chashan, Dongguan&#34; /&gt;&#xA;&lt;span class=&#34;position-absolute bottom-0 start-0 m-3 btn btn-light btn-sm shadow-sm fw-semibold&#34;&gt;&lt;i class=&#34;bi bi-box-arrow-up-right me-1&#34;&gt;&lt;/i&gt;Ver no Google Maps&lt;/span&gt;&#xA;&lt;/a&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/section&gt;</description>
			</item>
			<item>
				<title>Sobre Nós</title>
				<link>https://pengchi.net/pt/about-us/</link>
				<pubDate>Fri, 11 Sep 2026 05:55:46 +0000</pubDate>
				<guid>https://pengchi.net/pt/about-us/</guid>
				<description>&lt;section class=&#34;bg-white border-bottom&#34; style=&#34;width: 100vw; max-width: 100vw; margin-left: calc(50% - 50vw);&#34;&gt;&#xA;&lt;div class=&#34;container-fluid px-0&#34;&gt;&#xA;&lt;div class=&#34;row g-0&#34;&gt;&#xA;&lt;div class=&#34;col-lg-6&#34;&gt;&lt;style&gt;.swiper-manager-container.swiper-style17.swiper-slide-name-companyprofileen4k {--height:auto ;--gap:20px !important;--products-count:10;--height:auto!important;--swiper-slide-aspect-ratio:16/9!important;--swiper-slide-aspect-ratio-pad:16/9!important;--swiper-slide-aspect-ratio-mobile:16/9!important;}.swiper-manager-container.swiper-style17.swiper-slide-name-companyprofileen4k .slide-content {}&lt;/style&gt;&lt;div class=&#34;swiper-manager-container swiper-slide-name-companyprofileen4k swiper-slide-id- color-white content-align-default swiper-style17&#34; id=&#34;swiper-instance-27&#34; data-navigation=&#34;true&#34; data-pagination=&#34;true&#34; data-loop=&#34;true&#34; data-autoplay=&#34;false&#34; data-thumbs=&#34;false&#34; data-mute=&#34;true&#34; data-height=&#34;auto&#34; data-height-pad=&#34;&#34; data-height-mobile=&#34;&#34; data-style-id=&#34;17&#34; data-auto-height=&#34;true&#34; data-space-between=&#34;20&#34; data-slider-name=&#34;companyprofileen4k&#34; data-slides-per-view-pc=&#34;&#34; data-slides-per-group-pc=&#34;&#34; data-slides-per-view-pad=&#34;&#34; data-slides-per-group-pad=&#34;&#34; data-slides-per-view-mobile=&#34;&#34; data-slides-per-group-mobile=&#34;&#34; data-centered-slides=&#34;&#34; data-title-font-size=&#34;&#34; data-subtitle-font-size=&#34;&#34; data-description-font-size=&#34;&#34; data-link-font-size=&#34;&#34; data-google-fonts=&#34;&#34; data-content-box-max-width=&#34;&#34;&gt; &lt;div class=&#34;swiper main-swiper&#34; style=&#34;height:auto&#34;&gt; &lt;div class=&#34;swiper-wrapper&#34;&gt;&lt;div id=&#34;&#34; class=&#34;swiper-slide has-video&#34;&gt;&lt;div&gt;&lt;img src=&#34;https://pengchi.net/wp-content/uploads/2026/10/medical-sterile-storage-modern-clean-qqaawKKJ-1280x720-1.jpg&#34; loading=&#34;lazy&#34; alt=&#34;&#34; class=&#34;slide-background-img&#34; /&gt;&lt;/div&gt;&lt;div class=&#34;video-container slide-video&#34;&gt;&lt;lite-youtube videoid=&#34;BPfSOWqaFXY&#34; posterquality=&#34;maxresdefault&#34; style=&#34;width:100%;height:100%;aspect-ratio:auto;&#34;&gt;&lt;/lite-youtube&gt;&lt;script type=&#34;module&#34; src=&#34;https://cdn.jsdelivr.net/npm/@justinribeiro/lite-youtube@1/lite-youtube.js&#34;&gt;&lt;/script&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&lt;div class=&#34;swiper-info-btn&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-autoplay-btn&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-button-prev&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-button-next&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-pagination&#34;&gt;&lt;/div&gt;&lt;div class=&#34;swiper-scrollbar&#34;&gt;&lt;/div&gt;&lt;/div&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;col-lg-6 d-flex align-items-center&#34;&gt;&#xA;&lt;div class=&#34;p-4 p-lg-5&#34;&gt;&#xA;&lt;p&gt;&lt;span class=&#34;d-inline-block mb-3 small fw-semibold text-uppercase text-success&#34;&gt;Quem Somos&lt;/span&gt;&lt;/p&gt;&#xA;&lt;div class=&#34;d-flex gap-3 py-2 border-bottom align-items-start&#34;&gt;&#xA;&lt;div class=&#34;fw-bold flex-shrink-0&#34; style=&#34;flex: 0 0 132px;&#34;&gt;Tipo de Negócio&lt;/div&gt;&#xA;&lt;div class=&#34;text-body-secondary&#34;&gt;Fabricante/Fábrica&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;d-flex gap-3 py-2 border-bottom align-items-start&#34;&gt;&#xA;&lt;div class=&#34;fw-bold flex-shrink-0&#34; style=&#34;flex: 0 0 132px;&#34;&gt;Produtos Principais&lt;/div&gt;&#xA;&lt;div class=&#34;text-body-secondary&#34;&gt;&lt;a href=&#34;https://pengchi.net/medical-manual-single-leaf-air-tight-door/&#34;&gt;Porta Hermética Médica para Sala de Operação&lt;/a&gt;, &lt;a href=&#34;https://pengchi.net/medical-furniture/&#34;&gt;Mobiliário Médico&lt;/a&gt;, &lt;a href=&#34;https://pengchi.net/a-series-fume-hoods/&#34;&gt;Capelas de Fluxo Laminar&lt;/a&gt;, &lt;a href=&#34;https://pengchi.net/straight-type-treatment-cabinet/&#34;&gt;Armário Médico/Armário de Tratamento&lt;/a&gt;, &lt;a href=&#34;https://pengchi.net/custom-h-profile-aluminum-quick-assembly-modular-operating-room/&#34;&gt;Sala Cirúrgica Modular Sem Moldura&lt;/a&gt;, &lt;a href=&#34;https://pengchi.net/hvac-system/&#34;&gt;Unidade de Tratamento de Ar (AHU)&lt;/a&gt;, &lt;a href=&#34;https://pengchi.net/medical-single-leaf-automatic-sliding-door/&#34;&gt;Porta Médica Automática de Aço&lt;/a&gt;, &lt;a href=&#34;https://pengchi.net/a-series-all-steel-laboratory-bench/&#34;&gt;Bancada de Laboratório&lt;/a&gt;, &lt;a href=&#34;https://pengchi.net/medical-manual-interlocking-airlock-door/&#34;&gt;Porta de Aço para Sala Limpa&lt;/a&gt;, &lt;a href=&#34;https://pengchi.net/medical-door/&#34;&gt;Porta Médica&lt;/a&gt;, &lt;a href=&#34;https://pengchi.net/laboratory-furniture/&#34;&gt;Mobiliário de Laboratório&lt;/a&gt;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;d-flex gap-3 py-2 border-bottom align-items-start&#34;&gt;&#xA;&lt;div class=&#34;fw-bold flex-shrink-0&#34; style=&#34;flex: 0 0 132px;&#34;&gt;Linhas de Produção&lt;/div&gt;&#xA;&lt;div class=&#34;text-body-secondary&#34;&gt;10&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;d-flex gap-3 py-2 border-bottom align-items-start&#34;&gt;&#xA;&lt;div class=&#34;fw-bold flex-shrink-0&#34; style=&#34;flex: 0 0 132px;&#34;&gt;Serviço OEM Disponível&lt;/div&gt;&#xA;&lt;div class=&#34;text-body-secondary&#34;&gt;Sim&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;d-flex gap-3 py-2 border-bottom align-items-start&#34;&gt;&#xA;&lt;div class=&#34;fw-bold flex-shrink-0&#34; style=&#34;flex: 0 0 132px;&#34;&gt;Opções de Personalização&lt;/div&gt;&#xA;&lt;div class=&#34;text-body-secondary&#34;&gt;Personalização a partir de Amostras, Personalização a partir de Projetos, Personalização Completa, Personalização Parcial, Personalização Flexível&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;d-flex gap-3 py-2 border-bottom align-items-start&#34;&gt;&#xA;&lt;div class=&#34;fw-bold flex-shrink-0&#34; style=&#34;flex: 0 0 132px;&#34;&gt;Máquinas de Produção&lt;/div&gt;&#xA;&lt;div class=&#34;text-body-secondary&#34;&gt;Máquina de Corte a Laser, Fresadora, Máquina de Corte, Máquina CNC, Máquina de Estampagem, Máquina de Produção de Filtros&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;d-flex gap-3 py-2 align-items-start border-bottom-0&#34;&gt;&#xA;&lt;div class=&#34;fw-bold flex-shrink-0&#34; style=&#34;flex: 0 0 132px;&#34;&gt;N.º do Relatório de Auditoria TÜV Rheinland&lt;/div&gt;&#xA;&lt;div class=&#34;text-body-secondary&#34;&gt;MIC-ASI2521094  &lt;a href=&#34;https://www.verified.chn.tuv.com/en/&#34; target=&#34;_blank&#34; rel=&#34;noopener noreferrer&#34;&gt;Verificar Agora&lt;/a&gt;  &lt;a href=&#34;https://pengchi.net/docs/test-reports/tuv-rheinland-audit-report/&#34;&gt;Baixar Relatório em PDF&lt;/a&gt;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/section&gt;&lt;!-- ==================== SOBRE A PENGCHI — perfil da empresa, contêiner ==================== --&gt;&#xA;&lt;section class=&#34;py-5&#34;&gt;&#xA;&lt;div class=&#34;container&#34;&gt;&#xA;&lt;h2 class=&#34;fw-bold lh-sm mb-3&#34;&gt;Sobre a Pengchi&lt;/h2&gt;&#xA;&lt;p class=&#34;text-body-secondary lh-lg mb-3&#34;&gt;A Dongguan Pengchi Intelligent Equipment Technology Co., Ltd. é uma empresa profissional dedicada ao design, pesquisa e desenvolvimento, produção e vendas de salas de operação de alto padrão, produtos de suporte para laboratórios e salas limpas, centrais de material e esterilização (CSSD) e mobiliário médico. Seus principais produtos incluem armários de instrumentos para sala de operação, armários de anestesia e armários de medicamentos, capelas de fluxo laminar, portas automáticas, estações de enfermagem integradas, armários de tratamento hospitalar, armários de descarte, mesas de laboratório e janelas de passagem.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Blog</title>
				<link></link>
				<pubDate>Fri, 11 Sep 2026 05:54:54 +0000</pubDate>
				<guid></guid>
				<description></description>
			</item>
			<item>
				<title>Carrinho</title>
				<link>https://pengchi.net/pt/cart/</link>
				<pubDate>Fri, 11 Sep 2026 05:52:04 +0000</pubDate>
				<guid>https://pengchi.net/pt/cart/</guid>
				<description>&lt;div class=&#34;wp-block-woocommerce-cart alignwide is-loading&#34;&gt;&lt;!-- wp:woocommerce/filled-cart-block --&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-filled-cart-block&#34;&gt;&lt;!-- wp:woocommerce/cart-items-block --&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-items-block&#34;&gt;&lt;!-- wp:woocommerce/cart-line-items-block --&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-line-items-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-product-collection&#34;&gt;&lt;!-- wp:heading {&#34;textAlign&#34;:&#34;left&#34;,&#34;style&#34;:{&#34;spacing&#34;:{&#34;margin&#34;:{&#34;bottom&#34;:&#34;1rem&#34;}}}} --&gt;&#xA;&lt;h2 class=&#34;wp-block-heading has-text-align-left&#34; style=&#34;margin-bottom:1rem&#34;&gt;Você pode se interessar por…&lt;/h2&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-totals-block&#34;&gt;&lt;!-- wp:woocommerce/cart-order-summary-block --&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-order-summary-block&#34;&gt;&lt;!-- wp:woocommerce/cart-order-summary-heading-block --&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-order-summary-heading-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-order-summary-coupon-form-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-order-summary-subtotal-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-order-summary-fee-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-order-summary-discount-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-order-summary-shipping-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-order-summary-taxes-block&#34;&gt;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-express-payment-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-proceed-to-checkout-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-cart-accepted-payment-methods-block&#34;&gt;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-empty-cart-block&#34;&gt;&lt;!-- wp:heading {&#34;textAlign&#34;:&#34;center&#34;,&#34;className&#34;:&#34;with-empty-cart-icon wc-block-cart__empty-cart__title&#34;} --&gt;&#xA;&lt;h2 class=&#34;wp-block-heading has-text-align-center with-empty-cart-icon wc-block-cart__empty-cart__title&#34;&gt;Seu carrinho está vazio no momento!&lt;/h2&gt;&#xA;&lt;hr class=&#34;wp-block-separator has-alpha-channel-opacity is-style-dots&#34;/&gt;&#xA;&lt;h2 class=&#34;wp-block-heading has-text-align-center&#34;&gt;Novidades na loja&lt;/h2&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;</description>
			</item>
			<item>
				<title>Finalizar compra</title>
				<link>https://pengchi.net/pt/checkout/</link>
				<pubDate>Fri, 11 Sep 2026 05:52:04 +0000</pubDate>
				<guid>https://pengchi.net/pt/checkout/</guid>
				<description>&lt;div class=&#34;wp-block-woocommerce-checkout alignwide wc-block-checkout is-loading&#34;&gt;&lt;!-- wp:woocommerce/checkout-fields-block --&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-fields-block&#34;&gt;&lt;!-- wp:woocommerce/checkout-express-payment-block --&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-express-payment-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-contact-information-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-shipping-method-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-pickup-options-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-shipping-address-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-billing-address-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-shipping-methods-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-payment-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-additional-information-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-order-note-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-terms-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-actions-block&#34;&gt;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-totals-block&#34;&gt;&lt;!-- wp:woocommerce/checkout-order-summary-block --&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-order-summary-block&#34;&gt;&lt;!-- wp:woocommerce/checkout-order-summary-cart-items-block --&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-order-summary-cart-items-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-order-summary-coupon-form-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-order-summary-subtotal-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-order-summary-fee-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-order-summary-discount-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-order-summary-shipping-block&#34;&gt;&lt;/div&gt;&#xA;&lt;div class=&#34;wp-block-woocommerce-checkout-order-summary-taxes-block&#34;&gt;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;&#xA;&lt;/div&gt;</description>
			</item>
			<item>
				<title>Minha conta</title>
				<link>https://pengchi.net/pt/my-account/</link>
				<pubDate>Fri, 11 Sep 2026 05:52:04 +0000</pubDate>
				<guid>https://pengchi.net/pt/my-account/</guid>
				<description>&lt;p&gt;[woocommerce_my_account]&lt;!-- /wp:shortcode --&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>Produtos</title>
				<link></link>
				<pubDate>Fri, 11 Sep 2026 05:52:04 +0000</pubDate>
				<guid></guid>
				<description>&lt;p&gt;Solução de Sistema de Equipamentos Médicos Inteligentes&lt;/p&gt;</description>
			</item>
			<item>
				<title>Página de Exemplo</title>
				<link>https://pengchi.net/pt/sample-page/</link>
				<pubDate>Fri, 11 Sep 2026 05:37:51 +0000</pubDate>
				<guid>https://pengchi.net/pt/sample-page/</guid>
				<description>&lt;p&gt;Esta é uma página de exemplo. Ela é diferente de um post de blog porque ficará em um só lugar e aparecerá na navegação do seu site (na maioria dos temas). A maioria das pessoas começa com uma página Sobre que as apresenta aos potenciais visitantes do site. Ela pode dizer algo assim:&lt;/p&gt;&#xA;&lt;blockquote class=&#34;wp-block-quote&#34;&gt;&#xA;&lt;p&gt;Olá! Sou mensageiro de bicicleta durante o dia, aspirante a ator durante a noite, e este é o meu site. Moro em Los Angeles, tenho um ótimo cachorro chamado Jack e gosto de piña coladas. (E de ser pego pela chuva.)&lt;/p&gt;</description>
			</item>
			<item>
				<title>Política de Privacidade</title>
				<link>https://pengchi.net/pt/privacy-policy/</link>
				<pubDate>Fri, 11 Sep 2026 05:37:51 +0000</pubDate>
				<guid>https://pengchi.net/pt/privacy-policy/</guid>
				<description>&lt;h2 class=&#34;wp-block-heading&#34;&gt;Quem somos&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong class=&#34;privacy-policy-tutorial&#34;&gt;Texto sugerido: &lt;/strong&gt;O endereço do nosso website é: .&lt;/p&gt;&#xA;&lt;h2 class=&#34;wp-block-heading&#34;&gt;Comentários&lt;/h2&gt;&#xA;&lt;p&gt;&lt;strong class=&#34;privacy-policy-tutorial&#34;&gt;Texto sugerido: &lt;/strong&gt;Quando os visitantes deixam comentários no site, recolhemos os dados mostrados no formulário de comentários, bem como o endereço IP do visitante e a string do agente de utilizador do navegador para ajudar na deteção de spam.&lt;/p&gt;&#xA;&lt;p&gt;Uma string anonimizada criada a partir do seu endereço de e-mail (também chamada de hash) pode ser fornecida ao serviço Gravatar para verificar se o está a utilizar. A política de privacidade do serviço Gravatar está disponível aqui: https://automattic.com/privacy/. Após a aprovação do seu comentário, a sua foto de perfil fica visível ao público no contexto do seu comentário.&lt;/p&gt;</description>
			</item>
	</channel>
</rss>
