<?xml version="1.0" encoding="utf-8" standalone="yes"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
	<channel>
		<title>Pasokan Air dan Drainase on PENGCHI</title>
		<link>https://pengchi.net/id/docs/clean-operating-department-guide/water-supply-drainage/</link>
		<description>Recent content in Pasokan Air dan Drainase on PENGCHI</description>
		<generator>Hugo</generator>
		<language>id-ID</language>
		
		
		
		
			<atom:link href="https://pengchi.net/id/docs/clean-operating-department-guide/water-supply-drainage/index.xml" rel="self" type="application/rss+xml" />
			<item>
				<title>Fasilitas Pasokan Air</title>
				<link>https://pengchi.net/id/docs/clean-operating-department-guide/water-supply-drainage/water-supply-facilities/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/id/docs/clean-operating-department-guide/water-supply-drainage/water-supply-facilities/</guid>
				<description>&lt;h2 id=&#34;911-persyaratan-desain-pasokan-air&#34;&gt;9.1.1 Persyaratan Desain Pasokan Air&lt;/h2&gt;&#xA;&lt;p&gt;(1) Sistem pasokan air di departemen operasi bersih harus memiliki dua saluran masuk, seluruh pipa harus disembunyikan, dan langkah-langkah anti-kondensasi harus diterapkan.&lt;/p&gt;&#xA;&lt;p&gt;Ketentuan bahwa sistem pasokan air harus memiliki dua saluran masuk berarti pasokan air terputus tidak diizinkan, dan pasokan dua arah harus diterapkan. Pasokan air departemen operasi harus dijamin oleh dua saluran utama independen, sehingga ketika satu saluran gagal, saluran lain dapat segera digunakan. Jika hanya ada satu pipa pasokan air, tangki penyimpanan harus dipasang atau sumber air kedua harus ditambahkan untuk memastikan keamanan pasokan air. Tangki penyimpanan harus dilengkapi dengan kontrol ketinggian air dan fasilitas alarm darurat. Ketika sumber air tidak mencukupi atau pelampung rusak dan ketinggian air rendah, alarm harus dinyalakan untuk menarik perhatian personel manajemen, agar kebutuhan air selama operasi dapat dipenuhi tepat waktu.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Persyaratan Kualitas Air</title>
				<link>https://pengchi.net/id/docs/clean-operating-department-guide/water-supply-drainage/water-quality-requirements/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/id/docs/clean-operating-department-guide/water-supply-drainage/water-quality-requirements/</guid>
				<description>&lt;h2 id=&#34;921-air-yang-disuplai-ke-departemen-operasi-bersih&#34;&gt;9.2.1 Air yang Disuplai ke Departemen Operasi Bersih&lt;/h2&gt;&#xA;&lt;p&gt;Kualitas airnya harus memenuhi standar kualitas air minum, dan air untuk scrub tangan bedah sebaiknya melalui perlakuan penghilangan bakteri.&lt;/p&gt;&#xA;&lt;p&gt;Air yang disuplai ke departemen operasi bersih harus mematuhi standar nasional yang berlaku, yaitu &lt;em&gt;&amp;ldquo;Hygienic Specifications for Drinking Water Quality&amp;rdquo;&lt;/em&gt; (Wei Fa Jian Fa {2001} No. 161); ini merupakan persyaratan paling dasar. Di banyak negara, kualitas air yang disalurkan oleh perusahaan air minum perkotaan harus memenuhi standar air minum, dan di banyak negara di dunia orang dapat meminum air keran secara langsung hanya dengan membuka keran. Namun, situasinya di Tiongkok adalah air keran mengalami pencemaran sekunder akibat transportasi jarak jauh melalui jaringan pipa penyediaan air dan penyimpanan jangka panjang dalam wadah penyimpanan air, serta kontak dengan lingkungan sekitar yang tidak bersih (bakteri berkembang biak, terbentuknya karat, dll.). Air sumur mandiri yang dikelola oleh unit tertentu juga rentan terhadap pencemaran karena manajemen yang tidak baku. Oleh karena itu, air keran harus dilengkapi dengan perangkat perlakuan ulang tambahan seperti filtrasi dan disinfeksi sebelum digunakan. Hal ini telah diatur dengan jelas dalam Pasal 7 (8) &lt;em&gt;Peraturan Kota Beijing tentang Pengawasan dan Administrasi Higiene Air Minum Domestik&lt;/em&gt; dan dalam kode baru yang akan segera diterbitkan. Dapat dipahami bahwa di tempat-tempat yang memasang sistem penyediaan air bertekanan sekunder pada bangunan, dengan tangki penyimpanan air dan perangkat disinfeksi sekunder, kualitas tangki penyimpanan air, kondisi higiene di lokasi tangki, dan pengelolaan peralatan disinfeksi semuanya sangat tidak baku, dan pada kenyataannya disinfeksi sekunder tidak terjamin. Oleh karena itu, di departemen bedah, untuk air scrub dengan persyaratan lebih tinggi, disarankan memilih peralatan penghilang bakteri skala kecil untuk perlakuan disinfeksi ulang. Sebagai contoh, perangkat disinfeksi dan sterilisasi air seperti saringan keramik, sterilisator ultraviolet, ozon, dan klorin dioksida dapat digunakan untuk menyaring kotoran dalam air dan membunuh bakteri di dalamnya.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Persyaratan Ruang Scrub</title>
				<link>https://pengchi.net/id/docs/clean-operating-department-guide/water-supply-drainage/scrub-room-requirements/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/id/docs/clean-operating-department-guide/water-supply-drainage/scrub-room-requirements/</guid>
				<description>&lt;h2 id=&#34;931-bak-cuci-tangan-scrub-di-ruang-scrub-departemen-bedah-bersih&#34;&gt;9.3.1 Bak Cuci Tangan Scrub di Ruang Scrub Departemen Bedah Bersih&lt;/h2&gt;&#xA;&lt;p&gt;Bak cuci tangan scrub harus dilengkapi dengan keran yang tidak dioperasikan dengan tangan, dengan jumlah maksimal 2 keran per ruang operasi.&lt;/p&gt;&#xA;&lt;p&gt;【Referensi】Bak cuci tangan scrub di departemen bedah bersih harus berbentuk sempit dan dalam, dengan bagian dasar bak sedikit lebih kecil dibandingkan lebar bukaan bak. Saat melakukan scrub, seseorang menjulurkan kaki ke depan sehingga tubuh dapat mendekat ke bak, yang memudahkan proses scrub lengan; bak yang lebih dalam dapat mencegah air kotor terciprat keluar. Untuk mencegah infeksi bakteri akibat tangan menyentuh keran, bak cuci tangan scrub harus dilengkapi dengan sakelar yang tidak dioperasikan dengan tangan, dan di samping bak cuci tangan scrub harus terdapat tempat sabun dengan sakelar sentuh dan pengering tangan listrik. Saat ini, keran leher angsa banyak digunakan untuk bak cuci tangan scrub di rumah sakit dalam negeri; jenis sakelar kontrol yang lebih umum digunakan meliputi tipe yang dioperasikan dengan siku (terintegrasi dengan keran) dan tipe yang dioperasikan dengan kaki, serta sakelar yang dioperasikan dengan lutut, fotolistrik, dan sensor inframerah. Apa pun jenis sakelar yang dipilih, kualitasnya harus dapat diandalkan; jika tidak, kemajuan operasi akan terganggu.&lt;/p&gt;</description>
			</item>
			<item>
				<title>Fasilitas Drainase</title>
				<link>https://pengchi.net/id/docs/clean-operating-department-guide/water-supply-drainage/drainage-facilities/</link>
				<pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate>
				<guid>https://pengchi.net/id/docs/clean-operating-department-guide/water-supply-drainage/drainage-facilities/</guid>
				<description>&lt;h2 id=&#34;941-peralatan-drainase-di-ruang-operasi-bersih&#34;&gt;9.4.1 Peralatan Drainase di Ruang Operasi Bersih&lt;/h2&gt;&#xA;&lt;p&gt;Katup Pencampur Termostatis Tipe 525&lt;/p&gt;&#xA;&lt;ul&gt;&#xA;&lt;li&gt;Badan katup: Perunggu&lt;/li&gt;&#xA;&lt;li&gt;Piston pengatur dan pegas: Baja tahan karat&lt;/li&gt;&#xA;&lt;li&gt;Rentang penyesuaian suhu: 36~53℃&lt;/li&gt;&#xA;&lt;li&gt;Akurasi: ±2℃&lt;/li&gt;&#xA;&lt;li&gt;Tekanan maksimum: 10kg&lt;/li&gt;&#xA;&lt;li&gt;Suhu air maksimum: 90℃&lt;/li&gt;&#xA;&lt;li&gt;Kaliber: $\frac{1}{2}$~2 inci&lt;/li&gt;&#xA;&lt;/ul&gt;&#xA;&lt;p&gt;Gambar 9.3 Katup Pencampur Termostatis (Tipe 523)&lt;/p&gt;&#xA;&lt;p&gt;Peralatan drainase harus dilengkapi dengan perangkat segel air tinggi di bawah lubang pembuangan, dan langkah-langkah harus diambil untuk mencegah segel air rusak.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;[Referensi]&lt;/strong&gt; Di ruang operasi bersih, untuk mencegah kontaminasi oleh udara kotor, semua peralatan di dalam ruangan harus disegel untuk mencegah komunikasi dengan atmosfer luar. Pipa di bawah lubang pembuangan peralatan kamar cuci mengarah langsung ke lubang got saluran pembuangan luar; ketika tidak ada air, pipa tersebut berkomunikasi dengan atmosfer dan menjadi lubang ventilasi, di mana gas kotor dari saluran pembuangan dapat menyelinap ke dalam ruangan dan mencemari udara dalam ruangan. Untuk menghalangi gas berbahaya dan beracun masuk ke ruangan melalui pipa drainase, salah satu metode adalah menggunakan katup periksa drainase; namun, karena air limbah membawa banyak kotoran, di mana kotoran berserat mudah tersangkut pada komponen seperti cakram katup periksa, katup periksa drainase mungkin gagal menutup rapat dan merusak fungsi penyegelan gasnya. Metode lain adalah memasang bagian pipa bengkok pada titik di mana perlengkapan sanitasi terhubung ke sistem perpipaan drainase, dengan sejumlah air tertentu yang tertahan di bagian ini. Ketika peralatan sanitasi digunakan, lengkungan ini dapat membuang air limbah dengan lancar sementara gas terhalang. Ini adalah segel air perangkap di bawah lubang pembuangan peralatan, yang saat ini merupakan metode paling efektif. Kedalaman segel air ini tidak boleh kurang dari 50 mm; ketentuan ini ditentukan berdasarkan faktor-faktor seperti fluktuasi tekanan di dalam sistem perpipaan drainase dan penguapan segel air. Nilai apa pun yang lebih kecil dari ini dianggap tidak aman.&lt;/p&gt;</description>
			</item>
	</channel>
</rss>